Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Tuning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Preliminary Findings of the Experimental Development Unit Cold Flow Test for a Generation Zero Nuclear Propulsion Engine

Nuclear thermal propulsion (NTP) technology will greatly benefit human travel to Mars by significantly shortening transit times, improving crew safety, and providing more mission flexibility than traditional chemical rockets. As part of DRACO follow-on work to develop, build, and fly a generation zero NTP engine, a full scale flight-like experimental design unit (EDU) reactor was constructed to collect sufficient on-ground performance data to characterize flow induced vibrations (FIV) of critical reactor structures/components, inform development of the engine and reactor control algorithm, and collect pressure drop and flow distribution data across the reactor. The fluid conditions for the test program were designed to achieve system responses equivalent to that of an operational engine through all phases of engine operation including reactor startup, mainstage operation, reactor shutdown, and reactor cooldown. Over 100 tests were executed, flowing either GN2 or GHe through the EDU at varying flow rates and pressures. This experiment provided early validation of flow behavior and vibration risks before nuclear testing, boosted critical subsystem TRLs, informed design iterations, and reduced future test costs. The steady-state flow parameters for the experiment were modeled in Ansys Thermal Desktop, allowing rapid tuning and experiment-informed updates to a flight-like test matrix. The EDU dynamic environment was characterized with accelerometers, strain gauges, and high-frequency pressure transducers all sampled at 20 kHz. While many narrow-band oscillations were identified, no significant FIV occurred; the reactor structural responses tend to be enveloped by typical launch vehicle ascent vibration environments (defined up to 2 kHz), although significant energy is also present at higher frequencies.

Flow Induced Vibration↗

Extraction-Separation Performance and Dynamic Modeling of Orion Test Vehicles with Adams Simulation: 3rd Edition

NASA's Orion Capsule Parachute Assembly System (CPAS) Project is now in the qualification phase of testing, and the Adams simulation has continued to evolve to model the complex dynamics experienced during the test article extraction and separation phases of flight. The ability to initiate tests near the upper altitude limit of the Orion parachute deployment envelope requires extractions from the aircraft at 35,000 ft-MSL. Engineering development phase testing of the Parachute Test Vehicle (PTV) carried by the Carriage Platform Separation System (CPSS) at altitude resulted in test support equipment hardware failures due to increased energy caused by higher true airspeeds. As a result, hardware modifications became a necessity requiring ground static testing of the textile components to be conducted and a new ground dynamic test of the extraction system to be devised. Force-displacement curves from static tests were incorporated into the Adams simulations, allowing prediction of loads, velocities and margins encountered during both flight and ground dynamic tests. The Adams simulation was then further refined by fine tuning the damping terms to match the peak loads recorded in the ground dynamic tests. The failure observed in flight testing was successfully replicated in ground testing and true safety margins of the textile components were revealed. A multi-loop energy modulator was then incorporated into the system level Adams simulation model and the effect on improving test margins be properly evaluated leading to high confidence ground verification testing of the final design solution.

Varela, Jose G.↗

Design of an active helicopter control experiment at the Princeton Rotorcraft Dynamics Laboratory

In an effort to develop an active control technique for reducing helicopter vibrations stemming from the main rotor system, a helicopter model was designed and tested at the Princeton Rotorcraft Dynamics Laboratory (PRDL). A description of this facility, including its latest data acquisition upgrade, are given. The design procedures for the test model and its Froude scaled rotor system are also discussed. The approach for performing active control is based on the idea that rotor states can be identified by instrumenting the rotor blades. Using this knowledge, Individual Blade Control (IBC) or Higher Harmonic Control (HHC) pitch input commands may be used to impact on rotor dynamics in such a way as to reduce rotor vibrations. Discussed here is an instrumentation configuration utilizing miniature accelerometers to measure and estimate first and second out-of-plane bending mode positions and velocities. To verify this technique, the model was tested, and resulting data were used to estimate rotor states as well as flap and bending coefficients, procedures for which are discussed. Overall results show that a cost- and time-effective method for building a useful test model for future active control experiments was developed. With some fine-tuning or slight adjustments in sensor configuration, prospects for obtaining good state estimates look promising.

Marraffa, Andrew M.↗

Assessment of a Bidirectional Reflectance Distribution Correction of Above-Water and Satellite Water-Leaving Radiance in Coastal Waters

Water-leaving radiances, retrieved from in situ or satellite measurements, need to be corrected for the bidirectional properties of the measured light in order to standardize the data and make them comparable with each other. The current operational algorithm for the correction of bidirectional effects from the satellite ocean color data is optimized for typical oceanic waters. However, versions of bidirectional reflectance correction algorithms specifically tuned for typical coastal waters and other case 2 conditions are particularly needed to improve the overall quality of those data. In order to analyze the bidirectional reflectance distribution function (BRDF) of case 2 waters, a dataset of typical remote sensing reflectances was generated through radiative transfer simulations for a large range of viewing and illumination geometries. Based on this simulated dataset, a case 2 water focused remote sensing reflectance model is proposed to correct above-water and satellite water-leaving radiance data for bidirectional effects. The proposed model is first validated with a one year time series of in situ above-water measurements acquired by collocated multispectral and hyperspectral radiometers, which have different viewing geometries installed at the Long Island Sound Coastal Observatory (LISCO). Match-ups and intercomparisons performed on these concurrent measurements show that the proposed algorithm outperforms the algorithm currently in use at all wavelengths, with average improvement of 2.4% over the spectral range. LISCO's time series data have also been used to evaluate improvements in match-up comparisons of Moderate Resolution Imaging Spectroradiometer satellite data when the proposed BRDF correction is used in lieu of the current algorithm. It is shown that the discrepancies between coincident in-situ sea-based and satellite data decreased by 3.15% with the use of the proposed algorithm.

LISCO(LONG ISLAND SOUND COASTAL OBSERVATORY)↗

A probe for real-time images of particle beams and their analyses in a merged-beams apparatus

A real-time charged particle beam probe was developed, which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a fiber-optic faceplate, a flexible fiber-optic bundle, and a charge injection device (CID) in tandem. Digital or analog video output of the CID is fed into a computer or oscilloscope, respectively, for analysis or observation. The probe can be moved continuously along the beams' paths to obtain 'pictures' of the beam at any desired interval, thus giving three-dimensional form factors. The beams, singly or simultaneously, may be observed on the monitor facilitating the task of beam adjustment for optimum overlap. The digital output is used for quantitative computation of the beam overlaps. The device is linear with beam intensity, but the performance degrades with time due to beam damage of the microchannel plate.

Forand, J. L.↗

Semiconductor Reference Oscillator Development for Coherent Detection Optical Remote Sensing Applications

The NASA Earth Science Enterprise Advanced Technology Initiatives Program is supporting a program for the development of semiconductor laser reference oscillators for application to coherent optical remote sensing from Earth orbit. Local oscillators provide the frequency reference required for active spaceborne optical remote sensing concepts that involve heterodyne (coherent) detection. Two recent examples of such schemes are Doppler wind lidar and tropospheric carbon dioxide measurement by laser absorption spectrometry, both of which are being proposed at a wavelength of 2.05 microns. Frequency-agile local oscillator technology is important to such applications because of the need to compensate for large platform-induced Doppler components that would otherwise interfere with data interpretation. Development of frequency-agile local oscillator approaches has heretofore utilized the same laser material as the transmitter laser (Tm,Ho:YLF in the case of the 2.05-micron wavelength mentioned above). However, a semiconductor laser-based frequency-agile local oscillator offers considerable scope for reduced mechanical complexity and improved frequency agility over equivalent crystal laser devices, while their potentially faster tuning capability suggest the potential for greater scanning versatility. The program we report on here is specifically tasked with the development of prototype novel architecture semiconductor lasers with the power, tunability, and spectral characteristics required for coherent Doppler lidar. The baseline approach for this work is the distributed feedback (DFB) laser, in which gratings are etched into the semiconductor waveguide structures along the entire length of the laser cavity. However, typical DFB lasers at the wavelength of interest have linewidths that exhibit unacceptable growth when driven at the high currents and powers that are required for the Doppler lidar application. Suppression of this behavior by means of corrugation pitch-modulation (using a detuned central section to prevent intensity peaking in the center of the cavity) is currently under investigation to achieve the required performance goals.

distributed feedback (DFB) laser↗

New Features in the SPOC Pipeline Release 4.0

The Science Processing Operations Center is in the process of testing and deploying Release 4.0 of the codebase in the March 2019 timeframe. This paper describes the new features of the software and their likely impact on the quality of the TESS science data products. The major goals of Release 4.0 are to improve the extraction of photometry from the pixels in light of the non-uniform pointing performance and the identification of instrumental signatures from the light curves. We also describe modifications to the FFI pipeline to allow the generation of FFI light curves, correction of the instrumental systematics therein, and planet searches, primarily for the purpose of validating the 2-min pipeline against the FFI pipeline, but also to be able to provide cotrending basis vectors (CBVs) derived directly from the FFIs to the public to aid them in their extraction and correction of photometry. We also discuss the improvements in photometric performance of the pipeline and its various components.The lapse in funding experienced between 22 December 2018 and 27 January 2019 significantly delayed our ability to conduct integration testing as planned for late December/early January, delaying the start of V&V by one month to the end of February 2019.The TESS Mission is funded by NASA's Science Mission Directorate as an Astrophysics Explorer Mission.The Science Processing Operations Center is in the process of testing and deplo!"ing Release 4.0 of thecodebase In the March 2019 tlmeframe. This paper describes the new features or the software and theirlikely impact on the quality of the TESS science data products. The major goals or Release 4.0 are to Imtheidentification of instrumental signatures from the light cuNes. We also describe modifications tothe FFI pipeline to allow the generation of FFI light curves, correction of the instrumental systematicstherein, and planet searches, primarily for the purpose of validating the 2-min pipelineagainst the FFI pipeline, but also to be able to provide cotrending basis vectors (C3Vs) ,,.~,.;.derived directly from the FFls to the public to aid them in their extractbn and correction , :-; ~'-'\'.'.of photometry. We also discuss the Improvements In photometric performance• of ~~\":;:•the pipeline and its various components. :,;.-.;The lapse In funding experienced between 22 December 2018 and 27January 2019 significantly delayed our ability to conduct Integrationtesting as planned for late December/early January, delaying thestart of V&V by one month to the end of February 2019.The TESS Mission is funded by NASA's Science Mission Directorateas an Astrophysics Explorer Mission.o.iu.c...,.....~~New Features in SPOC 4.01. Use of quatemions In photometry and centroiding.2. Use of quaternions to Identify high-motion cadences and exclude same.3. Use of the TPS detections to deemphasize pathological cadences ("skyline flattenlng"I.4. Improved CAL calculations for black and smear correction.5. PA brightness metric calculation improvements (induo'e crowding in calrulation)./ • 6. Improved POC spike goodness metric.•~• 7. Improved handling of gaps and momentum duni:>S in POC.8. Improved tuning of POC., 9. Improved attitude tweak correction in PDC.10. Improvements in PDC introduced noise and correlation goodness metrics11. Using the improved spike goodness metric to minimize overlitting in the spikeremover ' • :,''l./ 12. Enable FFI processing through planet search.,,. ,• • "« ,;,,,•.~'A , 13.1 D4.V S mtreinaim-relipnoinrgts d aartcah irveetrdie tvoa Ml aAnSdT p ersistence to database 15. Improved management of jobs on the NAS Pleiadss supercomputer

Jenkins, Jon M.↗

Development of Low-Noise High Value Chromium Silicide Resistors for Cryogenic Detector Applications

Extremely high sensitivity detectors, such as silicon bolometers are required in many NASA missions for detection of photons from the x-ray to the far infrared regions. Typically, these detectors are cooled to well below the liquid helium (LHe) temperature (4.2 K) to achieve the maximum detection performance. As photoconductors, they are generally operated with a load resistor and a pre-set bias voltage, which is then coupled to the input gate of a source-follower Field Effect Transistor (FET) circuit. It is imperative that the detector system signal to noise performance be limited by the noise of the detector and not by the noise of the external components. The load resistor value is selected to optimize the detector performance. These two criteria tend to be contradictory in that these detectors require load resistors in the hundreds of megaohms, which leads to a higher Johnson noise. Additionally, the physical size of the resistor must be small for device integration as required by such missions as the NASA High Resolution Airborne Wide-Band Camera (HAWC) instrument and the Submillimeter High Angular Resolution Camera (SHARC) for the Caltech Submillimeter Observatory (CSO). We have designed, fabricated and characterized thin film resistors using a CrSi/TiW/Al metal system on optical quality quartz substrates. The resistor values range from 100 megaohms to over 650 megaohms and are Johnson noise limited at LHe temperatures. The resistor film is sputtered with a sheet resistance ranging from 300 ohms to 1600 ohms and the processing sequence developed for these devices allows for chemically fine tuning the sheet resistance in-situ. The wafer fabrication process was of sufficiently high yield (>80%) providing clusters of good resistors for integrated multiple detector channels, a very important feature in the assembly of these two instruments.

Jhabvala, Murzy↗

Operating characteristics of 120-millimeter-bore ball bearings at 3 million DN

A parametric study was performed with split inner-race 120-mm-bore angular-contact ball bearings at a speed of 25,000 rpm (3 million DN) at initial contact angles of 20 deg and 24 deg. Provisions were made for outer- and inner-race cooling and for injection of lubricant into the bearing through a number of radial holes in the split inner-race of the bearing. Oil flow and coolant rate to the bearing was controlled and varied for a total up to approximately 3.2 gal/min. Bearing temperature was found to decrease as the total lubricant flow to the bearing increased. However, at intermediate flow rates temperature began to increase with increasing flow. Power consumption increased with increasing flow rate. Bearing operating temperature, differences in temperatures between the inner and outer races, and bearing power consumption can be tuned to any desirable operating requirement. Cage speed increased by not more than 2 percent with increasing oil flow to the inner race.

Zaretsky, E. V.↗

Time-accurate Navier-Stokes computations of self-excited two-dimensional unsteady cavity flows

Time-accurate Navier Stokes computations were performed to study self-excited oscillatory shear layer behavior over a two-dimensional rectangular cavity and to gain insight into the vortex-acoustic coupling that sustains these oscillations. Results were obtained solving the full, unsteady compressible Navier-Stokes equations for Reynolds-averaged turbulent air flow past a cavity with L/d = 2. Conditions duplicated test conditions in experiments by Rossiter at Mach numbers varied from 0.6 to 1.2. The computational scheme was the USA 2D series code developed by Rockwell's Science Center with an algebraic turbulence model for the shear layer and recirculating region. Two physical conditions were simulated: an isolated cavity situated (1) in an infinite plane wall and (2) in an infinite channel with an opposing parallel wall. Computed results for (1) showed excellent agreement with Rossiter's measured amplitudes and frequencies. A tuned acoustic duct resonance effect was observed in (2), demonstrating a controlled change in the acoustic feedback mechanism and resultant amplification in computed oscillations.

Dougherty, N. Sam↗

The Integrated Safety-Critical Advanced Avionics Communication and Control (ISAACC) System Concept: Infrastructure for ISHM

Integrated System Health Management (ISHM) architectures for spacecraft will include hard real-time, critical subsystems and soft real-time monitoring subsystems. Interaction between these subsystems will be necessary and an architecture supporting multiple criticality levels will be required. Demonstration hardware for the Integrated Safety-Critical Advanced Avionics Communication & Control (ISAACC) system has been developed at NASA Marshall Space Flight Center. It is a modular system using a commercially available time-triggered protocol, ?Tp/C, that supports hard real-time distributed control systems independent of the data transmission medium. The protocol is implemented in hardware and provides guaranteed low-latency messaging with inherent fault-tolerance and fault-containment. Interoperability between modules and systems of modules using the TTP/C is guaranteed through definition of messages and the precise message schedule implemented by the master-less Time Division Multiple Access (TDMA) communications protocol. "Plug-and-play" capability for sensors and actuators provides automatically configurable modules supporting sensor recalibration and control algorithm re-tuning without software modification. Modular components of controlled physical system(s) critical to control algorithm tuning, such as pumps or valve components in an engine, can be replaced or upgraded as "plug and play" components without modification to the ISAACC module hardware or software. ISAACC modules can communicate with other vehicle subsystems through time-triggered protocols or other communications protocols implemented over Ethernet, MIL-STD- 1553 and RS-485/422. Other communication bus physical layers and protocols can be included as required. In this way, the ISAACC modules can be part of a system-of-systems in a vehicle with multi-tier subsystems of varying criticality. The goal of the ISAACC architecture development is control and monitoring of safety critical systems of a manned spacecraft. These systems include spacecraft navigation and attitude control, propulsion, automated docking, vehicle health management and life support. ISAACC can integrate local critical subsystem health management with subsystems performing long term health monitoring. The ISAACC system and its relationship to ISHM will be presented.

Gwaltney, David A.↗

Co-evolution for Problem Simplification

This paper explores a co-evolutionary approach applicable to difficult problems with limited failure/success performance feedback. Like familiar "predator-prey" frameworks this algorithm evolves two populations of individuals - the solutions (predators) and the problems (prey). The approach extends previous work by rewarding only the problems that match their difficulty to the level of solut,ion competence. In complex problem domains with limited feedback, this "tractability constraint" helps provide an adaptive fitness gradient that, effectively differentiates the candidate solutions. The algorithm generates selective pressure toward the evolution of increasingly competent solutions by rewarding solution generality and uniqueness and problem tractability and difficulty. Relative (inverse-fitness) and absolute (static objective function) approaches to evaluating problem difficulty are explored and discussed. On a simple control task, this co-evolutionary algorithm was found to have significant advantages over a genetic algorithm with either a static fitness function or a fitness function that changes on a hand-tuned schedule.

Haith, Gary L.↗

Spin-Up and Tuning of the Global Carbon Cycle Model Inside the GISS ModelE2 GCM

Planetary carbon cycle involves multiple phenomena, acting at variety of temporal and spacial scales. The typical times range from minutes for leaf stomata physiology to centuries for passive soil carbon pools and deep ocean layers. So, finding a satisfactory equilibrium state becomes a challenging and computationally expensive task. Here we present the spin-up processes for different configurations of the GISS Carbon Cycle model from the model forced with MODIS observed Leaf Area Index (LAI) and prescribed ocean to the prognostic LAI and to the model fully coupled to the dynamic ocean and ocean biology. We investigate the time it takes the model to reach the equilibrium and discuss the ways to speed up this process. NASA Goddard Institute for Space Studies General Circulation Model (GISS ModelE2) is currently equipped with all major algorithms necessary for the simulation of the Global Carbon Cycle. The terrestrial part is presented by Ent Terrestrial Biosphere Model (Ent TBM), which includes leaf biophysics, prognostic phenology and soil biogeochemistry module (based on Carnegie-Ames-Stanford model). The ocean part is based on the NASA Ocean Biogeochemistry Model (NOBM). The transport of atmospheric CO2 is performed by the atmospheric part of ModelE2, which employs quadratic upstream algorithm for this purpose.

Climate model↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

Formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

The formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

Formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗