Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The X-ray telescope on board ASCA

The Advanced Satellite for Cosmology and Astrophysics (ASCA) instrument uses identical conical foil X-ray mirrors for its four telescopes. One of the major advantages of ASCA's telescopes is the first time ever use of X-ray imaging over a broad energy band and high throughput for conducting astronomical spectroscopy. Nested thin foil reflectors make possible a large effective area up to 10 keV, even under the tight weight restriction of the ASCA spacecraft. The expected characteristics of the ASCA mirrors are summarized based on ray tracings and pre-flight calibrations. The total effective area of four telescopes at 1 and 7 keV are approximately 1200 and 600 sq cm, respectively. The image size (half power diameter: HPD) is about 3 min. The field of view is 24 min and 16 min full width at half maximum for 1 and 7 keV, respectively. Observations of several X-ray sources from space during the performance verification phase have confirmed those performances as well as the alignment of the optical systems.

Serlemitsos, Peter J.↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in real-time. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors.

Harrivel, Angela↗

Advances in space radiation shielding codes

Early space radiation shield code development relied on Monte Carlo methods and made important contributions to the space program. Monte Carlo methods have resorted to restricted one-dimensional problems leading to imperfect representation of appropriate boundary conditions. Even so, intensive computational requirements resulted and shield evaluation was made near the end of the design process. Resolving shielding issues usually had a negative impact on the design. Improved spacecraft shield design requires early entry of radiation constraints into the design process to maximize performance and minimize costs. As a result, we have been investigating high-speed computational procedures to allow shield analysis from the preliminary concept to the final design. For the last few decades, we have pursued deterministic solutions of the Boltzmann equation allowing field mapping within the International Space Station (ISS) in tens of minutes using standard Finite Element Method (FEM) geometry common to engineering design methods. A single ray trace in such geometry requires 14 milliseconds and limits application of Monte Carlo methods to such engineering models. A potential means of improving the Monte Carlo efficiency in coupling to spacecraft geometry is given.

manned↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Some observations on the mechanism of aircraft wing rock

A pressure scale model of Northrop F-5A was tested in NASA Ames Research Center Eleven-Foot Transonic Tunnel to simulate the wing rock oscillations in a transonic maneuver. For this purpose, a flexible model support device was designed and fabricated which allowed the model to oscillate in roll at the scaled wing rock frequency. Two tunnel entries were performed to acquire the pressure (steady state and fluctuating) and response data when the model was held fixed and when it was excited by flow to oscillate in roll. Based on these data, a limit cycle mechanism was identified which supplied energy to the aircraft model and caused the Dutch roll type oscillations, commonly called wing rock. The major origin of the fluctuating pressures which contributed to the limit cycle was traced to the wing surface leading edge stall and the subsequent lift recovery. For typical wing rock oscillations, the energy balance between the pressure work input and the energy consumed by the model aerodynamic and mechanical damping was formulated and numerical data presented.

Hwang, C.↗

Some observations on the mechanism of aircraft wing rock

A scale model of the Northrop F-5A was tested in NASA Ames Research Center Eleven-Foot Transonic Tunnel to simulate the wing rock oscillations in a transonic maneuver. For this purpose, a flexible model support device was designed and fabricated, which allowed the model to oscillate in roll at the scaled wing rock frequency. Two tunnel entries were performed to acquire the pressure (steady state and fluctuating) and response data when the model was held fixed and when it was excited by flow to oscillate in roll. Based on these data, a limit cycle mechanism was identified, which supplied energy to the aircraft model and caused the Dutch roll type oscillations, commonly called wing rock. The major origin of the fluctuating pressures that contributed to the limit cycle was traced to the wing surface leading edge stall and the subsequent lift recovery. For typical wing rock oscillations, the energy balance between the pressure work input and the energy consumed by the model's aerodynamic and mechanical damping was formulated and numerical data presented.

Hwang, C.↗

Non-GEO mobile satellite systems: A risk assessment

Since 1991, The MITRE Corporation has performed several independent evaluations of proposed mobile satellite service (MSS) systems that would operate from low Earth orbit (LEO) or medium Earth orbit (MEO), also known as intermediate circular orbit (ICO). This paper introduces a top level Risk Taxonomy tailored to summarize the technical and programmatic risks that MITRE has identified. In general, as risks are identified and addressed, a system's technical characteristics, cost and schedule are affected. This paper traces changes in three key parameters - satellite launch mass, system cost, and system schedule - for each of the five original non-GEO MSS systems for which license applications were made to the U.S. Federal Communications Commission (FCC) from November 1990 until June 1991. Finally, specific risk areas are identified using the Risk Taxonomy as a framework for discussion.

Gaffney, Leah M.↗

Continuously Regenerable Freeze-Out CO2 Control Technology

Carbon dioxide (CO2) removal technology development for portable life support systems (PLSS) has traditionally concentrated in the areas of solid and liquid chemical sorbents and semi-permeable membranes. Most of these systems are too heavy in gravity environments, require prohibitive amounts of consumables for operation on long term planetary missions, or are inoperable on the surface of Mars due to the presence of a CO2 atmosphere. This paper describes the effort performed to mature an innovative CO2 removal technology that meets NASA s planetary mission needs while adhering to the important guiding principles of simplicity, reliability, and operability. A breadboard cryogenic carbon dioxide scrubber (Cryo Scrubber) for a closed loop cryogenic PLSS was developed, designed, and tested, and a conceptual design suitable for a PLSS was developed based on the results of the breadboard testing. The Cryo Scrubber freezes CO2 and other trace contaminants out of expired vent loop gas using cooling available from a liquid oxygen (LOX) based PLSS. The device is continuously regenerable, with solid CO2 being removed from the cold freeze-out surfaces, sublimated, and vented overboard. Duration is limited only by the supply of LOX stored in the PLSS. Simplicity, reliability, and operability are universally important criteria for critical hardware on long duration Lunar or Mars missions. The Cryo Scrubber has no moving parts, requires no additional consumables, and uses no electrical power, contributing to its simplicity and reliability. It is easy to use; no operator action is required to prepare, use, or shut down the Cryo Scrubber, and it does not require charging or regeneration. The versatility of the concept allows for operation on earth, the moon, and Mars, and in microgravity.

Fricker, John↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

A Survey of NASA Standard Nondestructive Evaluation (NDE)

This document provides a comprehensive review to trace the evolution of NASA’s Standard nondestructive evaluation (NDE) flaw sizes provided in NASA-STD-5009B for fracture-critical metallic spaceflight hardware. A NASA Standard NDE flaw size is considered to be conservative such that most inspectors, trained and certified in the specific method, are expected to provide the required 90/95 probability of detection (POD) for that flaw size. As such, individual certified inspectors are not required to perform POD demonstration testing to be allowed to inspect fracture-critical hardware for that specific method.

Probability of Detection↗

Tone noise of three supersonic helical tip speed propellers in a wind tunnel

Three eight bladed supersonic helical tip speed propellers were tested in the NASA Lewis Wind Tunnel at through flow Mach numbers of 0.6, 0.7, 0.75, 0.8, and 0.85. Such propellers are being considered as propulsors for a future energy conservative aircraft. The three propellers of equal performance, incorporate different plan forms and different amounts of sweep in order to investigate their noise generation, which could cause a cabin environment problem. The acoustically designed propeller SR-3 had 45 deg of tip sweep and was significantly quieter at Mach 0.8 cruise than the straight bladed propeller, SR-2. An intermediate 30 deg tip sweep propeller, SR-1m exhibited a noise level between the other two. Enhanced pressure-time traces indicated that SR-2 and SR-1m exhibited shock-like pressure traces at Mach-0.8 cruise while the SR-3 did not. Noise trends with varying helical tip Mach number and blade loading were also observed.

Dittmar, J. H.↗

Hybrid techniques for complex aerospace electromagnetics problems

Important aerospace electromagnetics problems include the evaluation of antenna performance on aircraft and the prediction and control of the aircraft's electromagnetic signature. Due to the ever increasing complexity and expense of aircraft design, aerospace engineers have become increasingly dependent on computer solutions. Traditionally, computational electromagnetics (CEM) has relied primarily on four disparate techniques: the method of moments (MoM), the finite-difference time-domain (FDTD) technique, the finite element method (FEM), and high frequency asymptotic techniques (HFAT) such as ray tracing. Each of these techniques has distinct advantages and disadvantages, and no single technique is capable of accurately solving all problems of interest on computers that are available now or will be available in the foreseeable future. As a result, new approaches that overcome the deficiencies of traditional techniques are beginning to attract a great deal of interest in the CEM community. Among these new approaches are hybrid methods which combine two or more of these techniques into a coherent model. During the ASEE Summer Faculty Fellowship Program a hybrid FEM/MoM computer code was developed and applied to a geometry containing features found on many modern aircraft.

Aberle, Jim↗

Measurement and Validation of Bidirectional Reflectance of Space Shuttle and Space Station Materials for Computerized Lighting Models

Task illumination has a major impact on human performance: What a person can perceive in his environment significantly affects his ability to perform tasks, especially in space's harsh environment. Training for lighting conditions in space has long depended on physical models and simulations to emulate the effect of lighting, but such tests are expensive and time-consuming. To evaluate lighting conditions not easily simulated on Earth, personnel at NASA Johnson Space Center's (JSC) Graphics Research and Analysis Facility (GRAF) have been developing computerized simulations of various illumination conditions using the ray-tracing program, Radiance, developed by Greg Ward at Lawrence Berkeley Laboratory. Because these computer simulations are only as accurate as the data used, accurate information about the reflectance properties of materials and light distributions is needed. JSC's Lighting Environment Test Facility (LETF) personnel gathered material reflectance properties for a large number of paints, metals, and cloths used in the Space Shuttle and Space Station programs, and processed these data into reflectance parameters needed for the computer simulations. They also gathered lamp distribution data for most of the light sources used, and validated the ability to accurately simulate lighting levels by comparing predictions with measurements for several ground-based tests. The result of this study is a database of material reflectance properties for a wide variety of materials, and lighting information for most of the standard light sources used in the Shuttle/Station programs. The combination of the Radiance program and GRAF's graphics capability form a validated computerized lighting simulation capability for NASA.

Fletcher, Lauren E.↗

Elimination of Intermediate-Frequency Combustion Instability in the Fastrac Engine Thrust Chamber

A series of tests were conducted to measure the combustion performance of the Fastrac engine thrust chamber. The thrust chamber exhibited benign, yet marginally unstable combustion. The marginally unstable combustion was characterized by chamber pressure oscillations with large amplitudes and a frequency that was too low to be identified as acoustic or high-frequency combustion instability and too high to be identified as chug or low-frequency combustion instability. The source of the buzz or intermediate-frequency combustion instability was traced to the fuel venturi whose violently noisy cavitation caused resonance in the feedline downstream. Combustion was stabilized by increasing the throat diameter of the fuel venturi such that the cavitation would occur more quietly.

Rocker, Marvin↗

AXSIO and the NASA X-ray Mission Concept Study

The Advanced X-ray Spectroscopy and Imaging Observatory (AXSIO) focuses on the IXO science objectives ranked highly by the Decadal Survey: tracing orbits near 5MBH event horizons, measuring BH spin, characterizing outflows and the environment of AGN, observing 5MBH to z=6, mapping gas motion in clusters, finding the missing baryons, and observing cosmic feedback. AXSIO's streamlining of IXO includes reduction in the instrument complement to a calorimeter and a grating spectrometer, and relaxation of the angular resolution to 10". With 0.9 m2 effective area at 1.25 keV, AXSIO delivers a 30-fold performance increase over current missions for high-resolution spectroscopy and spectroscopic timing. NASA has also undertaken a study of notional missions to determine lower cost approaches to accomplishing IXO objectives over the next decade. Three concepts were studied; which as a group encompass the full range of IXO science. The capabilities and architecture of these missions are summarized.

Petre, Robert↗

The Cabauw Intercomparison Campaign for Nitrogen Dioxide Measuring Instruments (CINDI): Design, Execution, and Early Results

From June to July 2009 more than thirty different in-situ and remote sensing instruments from all over the world participated in the Cabauw Intercomparison campaign for Nitrogen Dioxide measuring Instruments (CINDI). The campaign took place at KNMI's Cabauw Experimental Site for Atmospheric Research (CESAR) in the Netherlands. Its main objectives were to determine the accuracy of state-ofthe- art ground-based measurement techniques for the detection of atmospheric nitrogen dioxide (both in-situ and remote sensing), and to investigate their usability in satellite data validation. The expected outcomes are recommendations regarding the operation and calibration of such instruments, retrieval settings, and observation strategies for the use in ground-based networks for air quality monitoring and satellite data validation. Twenty-four optical spectrometers participated in the campaign, of which twenty-one had the capability to scan different elevation angles consecutively, the so-called Multi-axis DOAS systems, thereby collecting vertical profile information, in particular for nitrogen dioxide and aerosol. Various in-situ samplers and lidar instruments simultaneously characterized the variability of atmospheric trace gases and the physical properties of aerosol particles. A large data set of continuous measurements of these atmospheric constituents has been collected under various meteorological conditions and air pollution levels. Together with the permanent measurement capability at the CESAR site characterizing the meteorological state of the atmosphere, the CINDI campaign provided a comprehensive observational data set of atmospheric constituents in a highly polluted region of the world during summertime. First detailed comparisons performed with the CINDI data show that slant column measurements of NO2, O4 and HCHO with MAX-DOAS agree within 5 to 15%, vertical profiles of NO2 derived from several independent instruments agree within 25% of one another, and MAX-DOAS aerosol optical thickness agrees within 20-30% with AERONET data. For the in-situ NO2 instrument using a molybdenum converter, a bias was found as large as 5 ppbv during day time, when compared to the other in-situ instruments using photolytic converters.

Atmospheric composition↗

Infrared Imaging using Sparse Microresonator Arrays and Compressed Sensing

In this work, we present an uncooled infrared (IR) thermal imager featuring a sparse array of resonant pixels that can be monolithically integrated with the readout electronics for long-term operation in high-temperature environments. Each of the detector pixels is made of an IR-sensitive GaN microresonator developed to be operated at up to 500 0C. The pixels are employed in sparse array configuration to allow for routing the signal carrying traces and to ease the routing from pixel to circuit, as well as to reduce the power consumption at the expense of moderate post-processing time and increased complexity to recover the image. Three 128 by 128 sparse resonator arrays with the array densities of 10%, 25% and 37.5% are designed, and used in conjunction with the Compressed Sensing (CS) method to reconstruct complex test images from highly incomplete data. Capabilities and performance metrics of the recovery technique are explored.

Rais-Zadeh, Mina↗

20-Years of Atmospheric Temperature, Water Vapor, Cloud, and Surface Temperature Anomalies and Trends Derived From Operational Hyperspectral Ir Sounders

Hyperspectral IR sounders such as AIRS on Aqua, CrIS on S-NPP, NOAA20 and JPSS-2, IASI on Metop A, B, and C provide high-quality atmospheric temperature, water, vapor, and greenhouse gas vertical profiles. Additionally, they provide atmospheric cloud properties, surface emissivity, and surface skin temperatures. We have developed two algorithms which can consistently derive these products from multiple IR sounders. The first one is a Single Field-of-view Sounder Atmospheric Product (SIFSAP) algorithm and the second one is a Climate Fingerprinting Sounder Product (ClimFiSP) algorithm. Compared to current operational AIRS and CrIS Level-2 (L2) algorithms, which perform one retrieval for each 3 by 3 field of views (FOVs) using a cloud-clearing approach, the SiFSAP algorithm, on the other hand, performs one retrieval for each FOV using an all-sky optimal estimation approach. The SiFSAP algorithm retrieves all the above-mentioned atmosphere and surface properties simultaneously including cloud properties with 3-time higher spatial resolution and 9-times more products. The core of the SiFSAP algorithm is an accurate and fast Principal Component-based Radiative Transfer Model (PCRTM), which can calculate hyperspectral radiance spectra under both clear and cloudy conditions. The PCRTM was developed in the past decade using consistent reference line-by-line radiative transfer model and spectroscopy for hyperspectral sounders such as AIRS, CrIS, IASI, NAST-I, and S-HIS. The SiFSAP retrieval algorithm also uses the same climatology a priori and associated covariances, which makes it ideal for generating high quality products for both weather and climate applications. Climate products are typically derived by performing spatial and temporal averaging of L2 products. It is a time-consuming process to generate L2 data products since AIRS, CrIS, and IASI have millions of observations each day with thousands of spectral channels for each observation. Additionally, differences in L2 retrieval algorithms for different satellite sensors can lead to errors in the climate products. Our ClimFiSP algorithm, which performs retrievals from spatiotemporally averaged L1 hyperspectral radiances directly, will be orders of magnitude faster than traditional method. he ClimFiSP algorithm uses consistent radiative kernels and a robust spectral fingerprinting method. It provides accurate data climate data fusion products from multiple satellite sensors. We have applied this method to both AIRS and CrIS (on SNPP and on NOAA 20) data and generated two decades climate data records for atmospheric temperature, water vapor, cloud, trace gases, and surface skin temperature. Both SiFSAP and ClimFiSP will be available at NASA GES DISC data center for public access.

Xu Liu↗