A Proposed Methodology for Estimating Decontamination Costs in MACCS 3.10.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
The Tribal Solar Initiative is a partnership between NREL and the Midwest Tribal Energy Resources Association. The Tribal Solar Initiative project goal is to articulate key barriers to Tribal solar and Tribal solar-plus-storage adoption at all scales and to ready stakeholders to implement options to address these challenges. This conference presentation focuses on net-metering and a tribal solar case study regarding net-metering.
Tribal land in the United States represents approximately 2% of the country's total landmass and holds more than 5% percent of solar photovoltaic potential. This resource is largely untapped, and Tribes often cite regulatory hurdles to achieving solar goals. This presentation provides an opportunity for interested stakeholders to better understand those hurdles and possible solutions to help advance Tribal solar adoption as well as weigh in on the findings of the Tribal Solar Initiative.
This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.
Explore the source record for details and available documents.
Thermal energy storage (TES) offers a unique storage solution wherein heat is stored for later use to thermally condition an application. Heat pumps (HPs) move heat from relatively cold to a relatively hot with an input of work. Integrating TES into a HP system adds a third temperature body, and the HP can be selectively coupled to operate between any two: a constant temperature application, a temporally fluctuating ambient temperature, or a constant temperature TES. Since the HP-TES system enables operation under different conditions depending on the pair of temperature bodies, changes in efficiency and capacity can be expected. Thus, TES can shift HP operation to more favorable conditions to deliver heat to the application. Consequently, TES increases the apparent capacity of the HP which might enable a nominally smaller HP to be used effectively. This paper outlines a method by which TES can reduce the size of a HP without sacrificing heat delivered to the application. The method is demonstrated for a building cooling application which realized a reduction in nominal HP size from 3 tons to 2.4 tons.
High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)
M5 is the reference alloy of AREVA NP for PWR cladding applications. It is a zirconium-based alloy containing 1% niobium, no tin, and well-controlled oxygen, iron, and sulfur contents. It has a fully recrystallized microstructure. The absence of tin in M5 results in a very low corrosion rate and hydrogen pick-up during normal operation, even at high burn-up and in high duty irradiation conditions. Due to this low hydrogen pick-up under irradiation (typically less than 100 ppm, End of Life), M5 retains a very good strength and an exceptional residual ductility during and after the accident. This allows utilities implementing M5 to simplify the safety analysis and to demonstrate significant margins regarding fuel related criteria. Simplified methods are easier for plants to implement and maintain for future plant operations and core design management. This paper specifically presents 3 examples on the safety improvement brought by M5 cladding. First, during a reactivity-induced accident (RIA), the properties of M5 are such that bounding analyses for future cycles are significantly simplified, in particular by demonstrating that fuel dispersal will not occur. The major aspects of the AREVA NP RIA methodology are presented. A second focus is made on the low hydrogen embrittlement of M5 and on its high ductility after quenching during a loss-of-coolant accident (LOCA). In a third part, the breakaway oxidation testing program currently under development in Paimboeuf (France) is described, including details about the testing devices and qualification. The tests have demonstrated that M5 cladding does not have breakaway at least up to 5000 s oxidation duration at 1000 C. degrees, which is much higher than the LOCA duration.