Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Probe for Sampling of Interstitial Fluid From Bone

An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.

Janle, Elsa M.↗

Effectiveness of a Wedge Probe to Measure Sonic Boom Signatures in a Supersonic Wind Tunnel

A wind tunnel investigation was conducted in the Langley Unitary Plan Wind Tunnel (UPWT) to determine the effectiveness of a wedge probe to measure sonic boom pressure signatures compared to a slender conical probe. A generic business jet model at a constant angle of attack and at a single model to probe separation distance was used to generate a sonic boom signature. Pressure signature data were acquired with both the wedge probe and a slender conical probe for comparison. The test was conducted at a Mach number of 2.0 and a free-stream unit Reynolds number of 2 million per foot. The results showed that the wedge probe was not effective in measuring the sonic boom pressure signature of the aircraft model in the supersonic wind tunnel. Data plots and a discussion of the results are presented. No tabulated data or flow visualization photographs are included.

Wilcox, Floyd J., Jr.↗

Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are often employed to perform field measurements in electric propulsion applications where there are time-varying fields. Magnetic field probes provide the means to measure these magnetic fields and can even be used to measure the plasma current density indirectly through the application of Ampere's law. Measurements of this type can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. Results of the development of a standard for B-dot probe measurements are presented, condensing the available literature on the subject into an accessible set of rules, guidelines, and techniques to standardize the performance and presentation of future measurements.

Polzin, Kurt A.↗

Design and Application of Hybrid Magnetic Field-Eddy Current Probe

The incorporation of magnetic field sensors into eddy current probes can result in novel probe designs with unique performance characteristics. One such example is a recently developed electromagnetic probe consisting of a two-channel magnetoresistive sensor with an embedded single-strand eddy current inducer. Magnetic flux leakage maps of ferrous materials are generated from the DC sensor response while high-resolution eddy current imaging is simultaneously performed at frequencies up to 5 megahertz. In this work the design and optimization of this probe will be presented, along with an application toward analysis of sensory materials with embedded ferromagnetic shape-memory alloy (FSMA) particles. The sensory material is designed to produce a paramagnetic to ferromagnetic transition in the FSMA particles under strain. Mapping of the stray magnetic field and eddy current response of the sample with the hybrid probe can thereby image locations in the structure which have experienced an overstrain condition. Numerical modeling of the probe response is performed with good agreement with experimental results.

Wincheski, Buzz↗

A Common Probe Design for Multiple Planetary Destinations

Introduction: Atmospheric probes have been successfully flown to planets and moons in the solar system to conduct in situ measurements. They include the Pioneer Venus multiprobes, the Galileo Jupiter probe, and Huygens probe. Probe mission concepts to five destinations, including Venus, Jupiter, Saturn, Uranus, and Neptune, have all utilized similarshaped aeroshells and concept of operations, namely a 45° sphere cone shape with high density heatshield material and parachute system for extracting the descent vehicle from the aeroshell. The current paradigm is to design a probe to meet specific mission requirements and to optimize mass, volume, and cost for a single mission. However, this methodology means repeated efforts to design an aeroshell for different destinations with minor differences. A new paradigm has been explored that has a "common probe" design that could be flown at these different destinations and could be assembled in advance with multiple copies, properly stored, and made available for future NASA missions.

Hwang, Helen H.↗

CHAP Enhances Versatility in Colloidal Probe Fabrication

A colloidal probe, comprising a colloidal particle attached to an atomic force microscope cantilever, is employed to measure directly interaction forces between the particle and a surface. It is possible to change or even destroy a particle while attaching it to a cantilever, thus limiting the types of systems to which the colloidal probe technique may be applied. Here we present the Controlled Heating and Alignment Platform (CHAP) for fabricating colloidal probes without altering the original characteristics of the attached particle. The CHAP applies heat directly to the atomic force microscope chip to rapidly and precisely control cantilever temperature. This minimizes particle heating and enables control over the viscosity of thermoplastic adhesive, to prevent it from contaminating the particle surface. 3D-printed components made the CHAP compatible with standard optical microscopes and streamlined the fabrication process while increasing the platform’s versatility. Using the CHAP with a thermoplastic wax adhesive, colloidal probes were fabricated using polystyrene and silica particles between 0.7 and 40 μm in diameter. We characterized the properties and interactions of the adhesive and particles, as well as the properties of the completed probes, to demonstrate the retention of particle features throughout fabrication. Pull-off tests with CHAP’s probes measured adhesive force values in the expected ranges and demonstrated that particles were firmly attached to the cantilevers.

Schmitz, Russell C.↗

A Multi-Probe Mission at Jupiter is Within our Reach!!

Soon after Galileo Probe mission, capabilities to manufacture and test heritage carbon-phenolic (HCP) TPS atrophied. The impact of capability loss to Outer Planet probe missions, Venus in-situ and Mars Sample Return (MSR) missions was realized after two decades. MSR (1997 – 2006) initiated a search and recover of HCP. Decadal Survey (2003) recommended JPOP mission (Jupiter Polar Orbiter and Probe), but lack of HCP TPS resulted in Juno being proposed without a probe. Decadal Survey (2013) recognized and advised NASA to close the TPS gap. With the community support, NASA initiated a technology development effort to close this gap in 2019 and today, missions to Venus, Saturn, Uranus, and MSR are enabled by new 3-D Woven TPS. Jupiter, the most demanding mission from an entry and TPS perspective ever, still lacks a viable qualified TPS. While the Science community needs to make the case for going back to Jupiter with a Probe, this work is an assessment of emerging capabilities to support such a mission when needed. Recent SOA developments are very promising to close this technology gaps. Encourage the Science Community about the feasibility of future Jupiter Multi-Probes Mission Engage the Entry System/TPS Technology Community as to the emerging capabilities and need to preserve them Educate and excite the early career and next generation students interested in future Science and technology challenge.

Ethiraj Venkatapathy↗

A Survey of FIR Probe Mission Concepts

The 2020 Decadal survey recommended that “The NASA Astrophysics Division should implement a line of probe missions with a mission cost cap of ~$1.5 billion (fiscal year 2020) and a targeted launch rate of approximately one per decade.” The survey highlighted two mission areas that were recommended to be competed for the first probe mission opportunity, either a “Far Infrared Imaging or Spectroscopy Mission” and “An X-Ray Probe to Complement ESA’s Athena Observatory.” Three Far-Infrared (FIR) Probe Mission proposals were submitted by PI-led teams in response to the NASA Astrophysics Probe Explorer (APEX) Solicitation released in July 2023. This talk will first outline the general science goals of the Far-IR community and the state of technology needed to field cutting-edge Far-IR missions. We will then discuss and contrast the publicly available details of the proposed probe missions and how they compare to the Origins Space Telescope concept as submitted to the 2020 Decadal survey.

Jake Connors↗

Band excitation method applicable to scanning probe microscopy

Methods and apparatus are described for scanning probe microscopy. A method includes generating a band excitation (BE) signal having finite and predefined amplitude and phase spectrum in at least a first predefined frequency band; exciting a probe using the band excitation signal; obtaining data by measuring a response of the probe in at least a second predefined frequency band; and extracting at least one relevant dynamic parameter of the response of the probe in a predefined range including analyzing the obtained data. The BE signal can be synthesized prior to imaging (static band excitation), or adjusted at each pixel or spectroscopy step to accommodate changes in sample properties (adaptive band excitation). An apparatus includes a band excitation signal generator; a probe coupled to the band excitation signal generator; a detector coupled to the probe; and a relevant dynamic parameter extractor component coupled to the detector, the relevant dynamic parameter extractor including a processor that performs a mathematical transform selected from the group consisting of an integral transform and a discrete transform.

Jesse, Stephen↗

Cyanine-based probe\tag-peptide pair fluorescence protein imaging and fluorescence protein imaging methods

A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

60 APPLIED LIFE SCIENCES↗

Band excitation method applicable to scanning probe microscopy

Methods and apparatus are described for scanning probe microscopy. A method includes generating a band excitation (BE) signal having finite and predefined amplitude and phase spectrum in at least a first predefined frequency band; exciting a probe using the band excitation signal; obtaining data by measuring a response of the probe in at least a second predefined frequency band; and extracting at least one relevant dynamic parameter of the response of the probe in a predefined range including analyzing the obtained data. The BE signal can be synthesized prior to imaging (static band excitation), or adjusted at each pixel or spectroscopy step to accommodate changes in sample properties (adaptive band excitation). An apparatus includes a band excitation signal generator; a probe coupled to the band excitation signal generator; a detector coupled to the probe; and a relevant dynamic parameter extractor component coupled to the detector, the relevant dynamic parameter extractor including a processor that performs a mathematical transform selected from the group consisting of an integral transform and a discrete transform.

42 ENGINEERING↗

Full information acquisition in scanning probe microscopy and spectroscopy

Apparatus and methods are described for scanning probe microscopy and spectroscopy based on acquisition of full probe response. The full probe response contains valuable information about the probe-sample interaction that is lost in traditional scanning probe microscopy and spectroscopy methods. The full probe response is analyzed post data acquisition using fast Fourier transform and adaptive filtering, as well as multivariate analysis. The full response data is further compressed to retain only statistically significant components before being permanently stored.

36 MATERIALS SCIENCE↗

Pump-probe ghost imaging with SASE FELs

In this paper we propose a new approach to measuring ultrafast dynamics with free-electron lasers (FELs). Ultrafast experiments are among the most promising avenues of research at x-ray FELs, with potential to reveal the chemical dynamics of charge separation, conical intersection crossing, and biologically mediated reactions. Pump-probe scanning is the standard approach to measure dynamics at x-ray FELs, but at the shortest time scales, and particularly for x-ray pump, x-ray probe experiments, the scans require challenging beam setups and can introduce systematic errors. Here we propose an alternative approach using the randomness of the self-amplified spontaneous emission (SASE) process to drive many simultaneous pump-probe experiments on each shot. Measuring the fluctuations in the incident beam’s time profile on a shot-to-shot basis enables reconstruction of ultrafast dynamics down to the coherence length of the FEL without the need for pump-probe scans. Due to similarity to ghost imaging, in which spatial properties are reconstructed by measuring the incident probe’s transverse properties, we call this ``pump-probe ghost imaging" (PPGI). In this paper we describe the method and simulate an example experiment. We also describe an alternative implementation that uses only spectral measurements, avoiding the need for direct time-domain diagnostics, and extending the method to the attosecond regime.

Ratner, Daniel Fried↗

Flexible electric probe

A flexible electric probe can include: a flexible substrate; and probe line conductors on the flexible substrate, the probe line conductors being essentially parallel to each other and having separations of about 5-50 microns. The flexible electric probe can further include connection conductors on the flexible substrate, the connection conductors and the probe line conductors electrically connected to each other, the probe line conductors positioned in first and second offset patterns with regard to the connection conductors.

Mazzeo, Brian A.↗

Cyanine-based probe\tag-peptide pair for fluorescence protein imaging and fluorescence protein imaging methods

A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid Microjunction Surface Sampling Probe Fluid Dynamics: Computational and Experimental Analysis of Coaxial Intercapillary Positioning Effects on Sample Manipulation

A coaxial geometry liquid microjunction surface sampling probe (LMJ-SSP) enables direct extraction of analytes from surfaces for subsequent analysis by techniques like mass spectrometry. Solution dynamics at the probe-to-sample surface interface in the LMJ-SSP has been suspected to influence sampling efficiency and dispersion but has not been rigorously investigated. The effect on flow dynamics and analyte transport to the mass spectrometer caused by coaxial retraction of the inner and outer capillaries from each other and the surface during sampling with a LMJ-SSP was investigated using computational fluid dynamics and experimentation. A transparent LMJ-SSP was constructed to provide the means for visual observation of the dynamics of the surface sampling process. Visual observation, computational fluid dynamics (CFD) analysis, and experimental results revealed that inner capillary axial retraction from the flush position relative to the outer capillary transitioned the probe from a continuous sampling and injection mode through an intermediate regime to sample plug formationmode caused by eddy currents at the sampling end of the probe. The potential for analytical implementation of these newly discovered probe operational modes is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High accuracy plasma density measurement using hybrid Langmuir probe and microwave interferometer method

High spatial resolution plasma density measurements have been taken as part of an investigation into magnetic nozzle physics at the NASA/MSFC Propulsion Research Center. These measurements utilized a Langmuir triple probe scanned across the measurement chord of either of two stationary rf interferometers. By normalizing the scanned profile to the microwave interferometer line-integrated density measurement for each electrostatic probe measurement, the effect of shot-to-shot variation of the line-integrated density can be removed. In addition, by summing the voltage readings at each radial position in a transverse scan, the line density can be reconstituted, allowing the absolute density to be determined, assuming that the shape of the profile is constant from shot to shot. The spatial and temporal resolutions of this measurement technique depend on the resolutions of the scanned electrostatic probe and the interferometer. The measurement accuracy is 9%-15%, which is on the order of the accuracy of the rf interferometer. The measurement technique was compared directly with both scanning rf interferometer and standard Langmuir probe theory. The hybrid technique compares favorably with the scanning rf interferometer, and appears more accurate than probe theory alone. Additionally, our measurement technique is generally applicable even for nonaxisymmetric plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nasa Glenn Icing Research Tunnel: 2018 Change in Drop-Sizing Equations Due to Change in Cloud Droplet Probe Sample Area

Although there has been no physical change to the cloud drop diameters in the NASA Glenn Icing Research Tunnel (IRT), the IRT cloud calibration team now has an improved understanding of the facility’s drop-sizing instrumentation, which has resulted in a recent change to the drop-sizing equations. Only the calculated values given in the previous calibration report have changed. In 2017, IRT staff found reason to believe that since at least 2014, the sample area for its Cloud Droplet Probe (CDP) (Droplet Measurement Technologies, Inc.) has been closer to 0.289 mm2, rather than the user manual’s suggested value of 0.24 mm2. In September 2017, the probe’s sample area was measured both before and after the probe was realigned, and the end sample area was measured to be 0.248 mm2. Following the probe’s realignment, drop size measurements were made in the IRT using the CDP as well as optical array probes OAP–230X and OAP–230Y (Particle Measurement Systems, Inc.). These measurements suggested that 0.289 mm2 was the more accurate value for historical measurements. When the CDP sample area used for calculations was changed from 0.24 to 0.289 mm2, distributions previously reported to have a median volumetric diameter (MVD) between 30 and 100 μm were instead calculated to have MVD values 10 to 18 percent higher. The analyses that led to these conclusions are reported in this paper, as well as the new drop-sizing equations that have been developed for the corrected measurement values. This report contains updates to drop-sizing data for the IRT’s “normal” operating conditions (MVD < 50 μm) and discusses the effects on the IRT’s “large-drop” conditions (Mod1 nozzles, Pair < 10 psig), but it does not include updates to the drop-sizing equations for those large-drop conditions.

Particle sizing↗