Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DEMAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-modality deep learning for pulse prediction in homogeneous nonlinear systems via parametric conversion

In this Letter, we introduce FusionNet, a multi-modality deep learning framework designed to predict and analyze output pulses in high-power rare-earth-doped laser systems driving parametric conversion in homogeneous guided nonlinear media. FusionNet integrates temporal, spectral, and physical experimental conditions to model ultrafast nonlinear phenomena, including parametric nonlinear frequency conversion, self-phase modulation, and cross-phase modulation in homogeneous guided systems such as gas-filled hollow-core fibers. These systems bridge physical models with experimental data, advancing our understanding of light-guiding principles and nonlinear interactions while expediting the design and optimization of on-demand high-power, high-brightness systems. Our results demonstrate a 73% reduction in prediction error and an 83% improvement in computational efficiency compared to conventional neural networks. This work establishes a new paradigm for accelerating parametric simulations and optimizing experimental designs in high-power laser systems, with further implications for high-precision spectroscopy, quantum information science, and distributed entangled interconnects.

47 OTHER INSTRUMENTATION↗

Additive Manufacturing: A New Paradigm for the Next Generation of High-Power-Density Direct-Drive Electric Generators

In recent years, there has been a growing demand for high-power-density direct-drive generators in the wind industry owing to their high reliability, torque per unit volume, and conversion efficiencies. However, direct-drive wind turbine generators are very large, low-speed electric machines, which pose remarkable design and manufacturing issues that challenge their upscaling potential and cost of implementation. With air-gap tolerance as the main design driver, the need for high stiffness shifts the focus toward support-structure design that forms a significant portion of the generator's total mass. Existing manufacturing processes allow the use of segmented-steel-weldment disk or spoke-arm assemblies that yield stiffer structures per unit mass but tend to be heavier and more expensive to build. As a result, there is a need for a transformative approach to realize lightweight designs that can also facilitate series production at competitive costs. Inspired by recent developments in metal additive manufacturing (AM), we explore a new freedom in the structural design space with a high potential for weight savings in direct-drive generators. This includes the feasibility of using nonconventional complex geometries, such as lattice-based structures as structurally efficient options. Powder-binder jetting of a sand-cast mold was identified as the most feasible AM technology to produce large-scale generator rotor structures with complex geometry. A parametric optimization study was performed and optimized results within deformation and mass constraints were found for each design. The response to the maximum Maxwell stress due to unbalanced magnetic pull was also explored for each design. Further, a topology optimization was applied for each parameter-optimized design to validate results and provide insights into further mass reduction. These novel designs catered for AM are compared in both deflection and mass to conventional rotor designs using NREL's systems engineering design tool, GeneratorSE. The optimized lattice design with a U-beam truss resulted in a 24% reduction in structural mass of the rotor and 60% reduction in radial deflection. It is demonstrated that additive manufacturing shifts the focus from manufacturability constraints toward lower mass.

17 WIND ENERGY↗

Life Cycle Assessment for Closed-Loop Pumped Hydropower Energy Storage in the United States

The federal government has initiated an aggressive set of policies to achieve a net-zero carbon emission goal for the electricity sector by 2050. As a result, rapid growth in deployment of renewable energy technologies is expected. Most commercially mature technologies are temporally variable and do not provide grid inertia, while renewable technologies with high projected deployment have intermittent generation methods. Energy storage technologies are needed to both dispatch power on-demand and help provide the needed grid inertia. Pumped storage hydro (PSH) is a well-established technology that has gained renewed interest in recent years offering energy-balancing, grid stability, control of electrical network frequency, and large-scale storage capacity. For widespread adoption of PSH, more information is needed regarding its current life cycle environmental impacts. The objective of this study is to perform a full life cycle assessment (LCA) of new closed-loop PSH in the U.S. The functional unit for this study is 1 kWh of electrical power delivered to the grid and the base case project lifetime is 80 years. The life cycle inventory for this project accounts for all material and energy flows associated with the green-field construction, operation, maintenance, and decommissioning of a closed-loop PSH plant in the U.S. Collected data represents a range of potential PSH specifications and geographic locations coming from all prospective closed-loop PSH installations in the U.S. with data available. In addition, existing PSH installations are used to provide assumptions for inventory inputs. Results presented will include the global warming potential (GWP IPCC 100a) and Energy Return on Investment (EROI) from our base case (average PSH installation) as well as from scenario analyses and model sensitivity. These results will be compared to the impacts from existing PSH sites and alternate storage technologies. Methods align with the assumptions and guidelines put in place by previous PSH LCAs to ensure an accurate comparison with the results from this report.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

RETHINKING THE FUTURE GRID: INTEGRATED NUCLEAR-RENEWABLE ENERGY SYSTEMS

The 2013 electricity generation mix in the United States consisted of ~13% renewables (hydropower, wind, solar, geothermal), 19% nuclear, 27% natural gas, and 39% coal. In the 2011 State of the Union Address, President Obama set a clean energy goal for the nation: “By 2035, 80 percent of America’s electricity will come from clean energy sources. Some folks want wind and solar. Others want nuclear, clean coal and natural gas. To meet this goal we will need them all.” The U.S. Department of Energy (DOE) Offices of Nuclear Energy (NE) and Energy Efficiency and Renewable Energy (EERE) recognize that “all of the above” means that we are called to best utilize all available clean energy sources. To meet the stated environmental goals for electricity generation and for the broader energy sector, there is a need to transform the energy infrastructure of the U.S. and elsewhere. New energy systems must be capable of significantly reducing environmental impacts in an efficient and economically viable manner while utilizing both hydrocarbon resources and clean energy generation sources. The U.S. DOE is supporting research and development that could lead to more efficient utilization of clean energy generation sources, including renewable and nuclear options, to meet both grid demand and thermal energy needs in the industrial sector. A concept being advanced by the DOE-NE and DOE-EERE is tighter coupling of nuclear and renewable energy sources in a manner that better optimizes energy use for the combined electricity, industrial manufacturing, and the transportation sectors. This integration concept has been referred to as a “hybrid system” that is capable of apportioning thermal and electrical energy to first meet the grid demand (with appropriate power conversion systems), then utilizing excess thermal and, in some cases, electrical energy to drive a process that results in an additional product. For the purposes of the present work, the hybrid system would integrate two or more energy resources to generate two or more products, one of which must be an energy commodity, such as electricity or transportation fuel. Subsystems would be integrated ‘‘behind’’ the electrical transmission bus and would be comprised of two or more energy conversion subsystems that have traditionally been separate or isolated. Energy flows would be dynamically apportioned as necessary to meet grid demand via a single, highly responsive connection to the grid that provides dispatchable electricity while capital-intensive generation assets operate at full capacity. Candidate region-specific hybrid energy systems selected for further study and figures of merit that will be used to assess system performance will be presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase II Pre-Front End Engineering Design Study)

GTI Energy (GTI) and team members Southern Company Services (SCS), Pacific Gas & Electric (PG&E) and the Electric Power Research Institute (EPRI) performed a Phase II Pre-Feed Study under contract DE-FE0032008 for Hydrogen Storage for Load-Following and Clean Power. The configuration of the proposed system consists of subsystems for on-site H 2 production, on-site H 2 storage (up to 54 MWth in commercial vessels) and H 2 combustion in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with an existing fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load and H 2 production is relatively constant by storing H 2 . The proposed system is an improvement over alternate low carbon dispatchable power options. Technoeconomic analyses show H 2 produced with GTI’s patented Compact Hydrogen Generator (CHG) with inherent carbon capture will be lower cost (Levelized Cost of Hydrogen, LCOH) relative to hydrogen produced with a Steam Methane Reformer (SMR) with an amine system for carbon capture. This lower cost hydrogen enables our integrated system to deliver electricity (Levelized Cost of Electricity, LCOE) at 17.4% lower cost relative to a SMR sourced H 2 -fired HRSG (with an amine system for carbon capture) – Steam Turbine Generator (STG). Our analysis using EPRI’s US REGEN macroeconomic model shows our system will have significant demand in the power market and therefore require significant capacity expansion (CHG plants built to deliver hydrogen) to deliver low cost, low carbon power. In Phase II, our Team has completed a detailed system definition including the development of process models, definition of battery limits, Process Flow Diagrams (PFDs), Piping and Instrumentation Drawings (P&IDs), and a plant layout. A preliminary design for the key components of the CHG was developed including component lists & specifications. An evaluation of environmental and permitting considerations was completed and included the development of an Environmental Information Volume (EIV). The duct burners, which are flexible and can burn hydrogen and/or natural gas, were defined and initial CFD analyses were completed.

03 NATURAL GAS↗

Probabilistic Hydropower Flexibility Valuation: Case Studies for Boating Flow Regime

The optimal scheduling of hydropower generation holds significant importance to power system operation. The unique requirements of environmental constraints and the power system, depending on their respective objectives, demand distinct flow patterns. While power system stakeholders strive to optimize revenue in electricity markets, stakeholders from boating recreation seeks to identify flow ranges that optimize the boating experience. In pursuit of a win-win solution, this study aims to reconcile the interests of various stakeholders in hydropower scheduling. The maximum revenue from day-ahead electricity market is explored through an optimization process considering both plant operation constraints, boating flow constraints, water availability, and market prices. Results of real world case studies at a river in California show that the proposed approach can achieve dual objectives: maximizing market revenue while addressing boating recreation necessities. In addition, as the accuracy of electricity price forecasting and flow forecasting increase, the optimal revenue becomes increasingly advantageous to hydropower plant operators.

13 HYDRO ENERGY↗

Satellite communications experiment for the Ontario air ambulance service

A satellite communications experiment was conducted to develop a reliable voice communications system between paramedics and doctors at certain larger medical centers. The experiment used INMARSAT's Atlantic Ocean Region satellite which provides coverage to the western border of Ontario. Forward downlink power from the satellite is in great demand, so two highly power-efficient modulation schemes were chosen for evaluation during the experiment. These were amplitude-companded single-sideband (ACSSB) and linear predictive coding in conjunction with DMSK modulation. Good performance with a signal to noise ratio of about 10 dB was demonstrated from many parts of the province with the evevation angle to the satellite ranging from five to twenty degrees and with the aircraft both in-flight and on the runway.

Butterworth, John S.↗

International Space Station Solar Array Wing On-Orbit Electrical Performance Degradation Measured

The port-side photovoltaic power module (P6) was activated on the International Space Station in December 2000. P6 provides electrical power to channels 2B and 4B to operate ISS power loads. A P6 is shown in the preceding photograph. This article highlights the work done at the NASA Glenn Research Center to calculate the on-orbit degradation of the P6 solar array wings (SAWs) using on-orbit data from December 2000 to February 2003. During early ISS operations, the 82 strings of photovoltaic cells that make up a SAW can provide much more power than is necessary to meet the demand. To deal with excess power, a sequential shunt unit successively shunts the current from the strings. This shunt current was the parameter chosen for the SAW performance degradation study for the following reasons: (1) it is based on a direct shunt current measurement in the sequential shunt unit, (2) the shunt current has a low temperature dependence that reduces the data correction error from using a computationally derived array temperature, and (3) the SSU shunt current is essentially the same as the SAW short-circuit current on a per-string basis.

Gustafson, Eric D.↗

A GaN-based Four-Switch Buck-Boost Converter using Ripple Correlation Control for Maximum Power Point Tracking in Dynamic Deep Space Environments

As the demand for high-performance power conversion in spacecraft continues to grow and spacecraft mass and volume budgets become increasingly tight, it is essential to design DC-DC converters with higher efficiency and power density. Although photovoltaic (PV) efficiency has increased over time, solar irradiance and temperatures can fluctuate dramatically in deep space. This causes significant variations in the maximum power point (MPP) of the PV array, which can decrease the overall system efficiency unless accounted for. Thus, it is imperative to track the MPP of the PV panels to maintain optimal efficiency. This paper presents the experimental development of a four-switch, GaN-based buck-boost converter with an implementation of the Ripple Correlation Control (RCC) MPPT algorithm for dynamic deep space environments. Due to the use of GaN HEMTs, the experimental system achieves better efficiency and power density compared to the previous state of the art implementations. A simulation of the prototype buck-boost converter was implemented in SaberRD (Synopsis), and a digital design of the RCC-based MPPT controller utilizing the StateAMS tool is presented. The simulation results show that this controller swiftly and precisely converged to the MPP of the source PV panels in a dynamic solar irradiance condition.

Mahmud, Sadab↗

Industrial Load Flexibility, the U.S. Power Grid and Ammonia

A variable renewable power grid is a new technological regime that involves real time harvesting and low-cost availability of energy resources coupled with storage to meet additional needs. Decarbonization through electrification of end uses formerly met by combustion processes will be a concurrent trend. Taken together, these two changes may make flexibility on the demand side more valuable to the grid and to industrial users. Industry accounted for 26% of US power demand in 2021. Traditionally, industrial processes for producing ammonia and other basic materials have been optimized for a system based on fossil resources, where energy can be called upon according to needs. Large capital expenditures as well as safety considerations have favored plants running at steady state at close to their maximum capacity. It is possible, however, that the renewable energy transition will offer opportunities to sectors that can operate in a more flexible manner. Innovations that make use of flexibility to enhance their business model to move forward, individuals and groups active in their development, use and regulation, together with institutions and infrastructures, can be considered as a technological innovation system (TIS). Beyond economic and technical factors on their own, the TIS is an important analysis framework for studying the development and diffusion of technologies. This work attempts to map the TIS of flexible industrial loads and their interaction with electric power in the US, with a particular focus on ammonia as a case study. We have conducted interviews with stakeholders involved in ammonia projects, working in system operators, trade groups, regulators and utilities. We assess to what extent a technological innovation system is functioning and document characteristics that allow industries to operate flexibly.

ammonia↗

Cost and Performance Baseline for Fossil Energy Plants Volume 3: Low Rank Coal and Natural Gas to Electricity

This report presents an independent assessment of the cost and performance of select fossil energy power systems—pulverized coal (PC), circulating fluidized bed (CFB), and natural gas combined cycle (NGCC) plants—using a systematic, transparent technical and economic approach. This is Volume 3 of a five-volume series, which comprise the following reports: Volume 1: Bituminous Coal and Natural Gas to Electricity; Volume 2: Coal to Synthetic Natural Gas and Ammonia (Various Coal Ranks); Volume 3: Low Rank Coal and Natural Gas to Electricity; Volume 4: Bituminous Coal to Liquid Fuels; and Volume 5: Natural Gas Electricity Generating Units for Flexible Operation. The cost and performance of fossil fuel-based generation technologies represented in this report (and the series at large) are important inputs to assessments and determinations of technology combinations to be utilized to meet the projected demands of future power markets. In addition to informing technology comparisons, the reference plant configurations found in this report provide perspective for regulators and policy makers. From a research and development perspective, this report is used to assess goals and metrics and to provide a consistent basis for comparing developing technologies.

20 FOSSIL-FUELED POWER PLANTS↗

A hybrid building thermal modeling approach for predicting temperatures in typical, detached, two-story houses

Within the residential building sector, the air-conditioning (AC) load is the main target for peak load shifting and reduction since it is the largest contributor to peak demand. By leveraging its power flexibility, residential AC is a good candidate to provide building demand response and peak load shifting. For realization of accurate and reliable control of AC loads, a building thermal model, which characterizes the properties of a building’s envelope and its thermal mass, is an essential component for accurate indoor temperature or cooling/heating demand prediction. Building thermal models include two types: “Forward” and “Data-Driven”. Due to time-saving and cost-effective characteristics, different data-driven models have been developed in a number of research studies. However, few developed models can predict temperatures in respective zones of a multiple-zone building with an open air path between zones e.g., an open stairwell connecting two floors of a home. In this research, a novel hybrid modeling approach is proposed to predict the average indoor air temperatures of both the upstairs and downstairs. This “hybrid” solution integrates both gray-box, i.e. RC model and black-box models. A developed RC model is used to predict the building mean temperature, and black-box model, in which the supervised machine learning algorithms are leveraged, is used to predict the temperature difference between the downstairs and upstairs. Compared with the measured data from a real house, the results obtained have acceptable/satisfactory accuracy. The method proposed in this study integrates the advantages of black-box and gray-box modeling. As a result, it can be used as a reliable alternative to predict the average temperatures in respective floors of typical detached two-story houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cross-Layer Self-Adaptive/Self-Aware System Software for Exascale Systems

The extreme level of parallelism coupled with the limited available power budget expected in the exascale era brings unprecedented challenges that demand optimization of performance, power and resiliency in unison. Scalability on such systems is of paramount importance, while power and reliability issues may change the execution environment in which a parallel application runs. To solve these challenges exascale systems will require an introspective system software that combines system and application observations across all system stack layers with online feedback and adaptation mechanisms. In this paper we propose the design of a novel self-aware, self-adaptive system software in which a kernel-level Monitor, which continuously inspects the evolution of the target system through observation of Sensors, is combined with a user-level Controller, which reacts to changes in the execution environment, explores opportunities to increase performance, save power and adapts applications to new execution scenarios. We show that the monitoring system accurately monitors the evolution of parallel applications with a runtime overhead below 1-2%. As a test case, we design and implement a user-runtime system that aims at optimizing application’s performance and system power consumption on complex hierarchical architectures. Our results show that our adaptive system reaches 98% of performance efficiency of manually-tuned applications.

High Performance computing, Self-aware/self-adapti↗

Uncontrolled Electric Vehicle Charging Impacts on Distribution Electric Power Systems with Primarily Residential, Commercial or Industrial Loads

An increase in Electric Vehicles (EV) will result in higher demands on the distribution electric power systems (EPS) which may result in thermal line overloading and low voltage violations. To understand the impact, this work simulates two EV charging scenarios (home- and work-dominant) under potential 2030 EV adoption levels on 10 actual distribution feeders that support residential, commercial, and industrial loads. The simulations include actual driving patterns of existing (non-EV) vehicles taken from global positioning system (GPS) data. The GPS driving behaviors, which explain the spatial and temporal EV charging demands, provide information on each vehicles travel distance, dwell locations, and dwell durations. Then, the EPS simulations incorporate the EV charging demands to calculate the power flow across the feeder. Simulation results show that voltage impacts are modest (less than 0.01 p.u.), likely due to robust feeder designs and the models only represent the high-voltage (“primary”) system components. Line loading impacts are more noticeable, with a maximum increase of about 15%. Additionally, the feeder peak load times experience a slight shift for residential and mixed feeders (≈1 h), not at all for the industrial, and 8 h for the commercial feeder.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services

Demand response and energy storage play a profound role in the smart grid. The focus of this paper is to evaluate benefits of coordination of flexible loads and energy storage for power grid and end user services. We present a Generalized Battery Model (GBM) to describe the flexibility of building loads and energy storage. A Model Predictive Control (MPC) approach is proposed to characterize the GBM parameters (power and energy limits) for flexible building loads. Moreover, we develop optimal coordination algorithms for them to provide ancillary and end user services such as energy arbitrage, frequency regulation, spinning reserve, as well as energy and demand charge reduction. Several case studies have been performed to demonstrate the efficacy of the GBM and coordination algorithms, and evaluate the benefits of using their flexibility to provide grid and end user services. We show that optimal coordination yields significant cost saving and revenue. Moreover, the best option for grid services is to provide energy arbitrage and frequency regulation, because spinning reserve cannot compete with regulation service. Furthermore, when coordinating flexible loads with energy storage to provide end user services, it is recommended to consider both the time-of-use (TOU) price and demand charge rather than the TOU price only in order to flat the aggregate power profile.

Hao, He↗

Earth Battery

It’s the bane of renewable energy. No matter how efficient photovoltaic cells become or how much power a wind turbine can capture, someone will counter with, “What happens when the sun goes down and wind doesn’t blow?” And the person who poses that question uses it as an argument in favor of traditional baseload power. While it’s true that the way the electrical grid has developed in North America and Europe doesn’t lend itself to the start-and-stop, opportunistic nature of wind and solar, there are ways to meet the challenge. Electricity can be stored in batteries or water pumped uphill into reservoirs when power generation exceeds demand, to be tapped when needed. Unfortunately, utility-scale battery storage is prohibitively expensive, and pumped hydro is possible only in particular geographic locations. What is needed is a large-scale, distributed, dispatchable energy storage system that can smooth out a renewable energy generation profile that changes by the minute as well as over the course of the day or the season. Colleagues from Lawrence Livermore National Laboratory, the Ohio State University (led by Jeffrey Bielicki), and the University of Minnesota (led by Jimmy Randolph), and I have developed a system that can do all that. What’s more, this system actually sequesters carbon dioxide—a gas implicated in global climate change—as part of its normal operation. Furthermore, we have modeled our system and found that, if it can be successfully demonstrated in the field, it could provide utility-scale diurnal and seasonal energy storage (many hundreds of MWe) and dispatchable power, while permanently sequestering CO 2 from industrial-scale fossil-energy power plants. Certainly, an energy storage system is only as clean or as green as the primary generation it’s working with. But it is going to be difficult to implement solar or wind power to a degree high enough to make a difference in global carbon dioxide emissions without utility-scale energy storage.

15 GEOTHERMAL ENERGY↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2018

This report presents an enhanced performance evaluation of emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES) data from 1998 through 2018 and (2) maintenance unavailability (UA) performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2018. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: sub-component, failure cause, detection method, recovery, manufacturer, and EDG rating. A statistically significant increasing trend was identified in the frequency of FTLR demands for emergency power system (EPS) and high pressure core spray (HPCS) EDGs and a statistically significant decreasing trend was identified in the frequency of run > 1H hours for EPS and HPCS EDGs.

99 GENERAL AND MISCELLANEOUS↗