Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Preliminary design of electrostatic sensors for MITICA beam line components

Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discharge Chamber Performance of the NEXIS Ion Thruster

The Nuclear-Electric Xenon Ion System (NEXIS) thruster was designed to produce greater than or equal to 70% efficiency at ISPs in excess of 6500 sec and total power levels in excess of 15 kW. In order to achieve this performance, the thruster requires a large area plasma generator capable of high propellant utilimtion efficiency and low discharge loss while producing a very flat, uniform beam profile. Fortunately, larger thrusters can be made more uniform and efficient due to the higher volume to surface ratio, provided that the magnetic cusp confinement is designed properly and the thruster length to diameter ratio is adequate. This paper describes the discharge chamber performance of the NEXIS Laboratory Model (LM) thruster. The LM discharge chamber is 65 cm in diameter at the grid plane and uses 6 ring-cusps to provide magnetic confinement of the plasma. The thruster was tested with flat carbon-carbon composite grids with the hole pattern masked to 57 cm in diameter and a conventional Type-B "1/2" diameter hollow cathode. During the preliminary "discharge only" tests, the LM thruster demonstrated profile factors of 0.84 and a discharge loss of about 160 eV/ion at 25 V discharge voltage and over 90% propellant utilization efficiency in simulated beam extraction experiments at 3.9 A of beam current. Analysis of the data from these tests used the discharge-only model developed by Brophy. Subsequent beam extraction experiments validated the key variables used in the model to predict the performance from the discharge-only data, and demonstrated 3.9 A of beam current at over 90% propellant utilization efficiency with a flatness parameter of better than 0.8 and a discharge loss of about 185 eV/ion. The slightly higher discharge loss measured during beam extractions was found to be due to a lower screen transparency in the as-manufactured LM grid set. Plasma measurements with a scanning probe internal to the thruster near the screen grid showed plasma densities over l x 10(exp 11) per cubic centimeter and electron temperatures of 3.5 to 5.5 eV depending on the operation parameters. The performance of the NEXIS discharge chamber contributed to the over 78% thruster efficiency measured during beam extraction at 7500 sec ISP and 25 kW of power, and over 81% thruster efficiency measured at 8500 sec ISP.

plasma generation↗

Spectroscopic interpretation and velocimetry analysis of fluctuations in a cylindrical plasma recorded by a fast camera

Fast visible imaging is used on a cylindrical magnetized argon plasma produced by thermionic discharge in the Mirabelle device. To link the information collected with the camera to a physical quantity, fast camera movies of plasma structures are compared to Langmuir probe measurements. High correlation is found between light fluctuations and plasma density fluctuations. Contributions from neutral argon and ionized argon to the overall light intensity are separated by using interference filters and a light intensifier. Light emitting transitions are shown to involve a metastable neutral argon state that can be excited by thermal plasma electrons, thus explaining the good correlation between light and density fluctuations. The propagation velocity of plasma structures is calculated by adapting velocimetry methods to the fast camera movies. The resulting estimates of instantaneous propagation velocity are in agreement with former experiments. The computation of mean velocities is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic and neutron measurements on the PF-400 plasma focus facility

Parasitic currents shunting up to one-half of the total discharge current were detected using magnetic probes on a Filippov-type plasma focus facility with a maximum total current of 1 MA and stored energy of 80 kJ. The measured time dependence of neutron emission from the discharge indicates that the parameters of the neutron pulse are closely related to those of the imploding current sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of ionic liquid electrode on pulse discharge plasmas in the wide range of gas pressures

Gas-liquid interfacial pulse discharge plasmas are generated in the wide range of gas pressures, where an ionic liquid is used as the liquid electrode. By analyzing the characteristics of discharge voltage and current, the discharge mechanisms at low and high pressures are found to be dominated by secondary electron emission and first Townsend ionization, respectively. Therefore, the discharge properties at low and high pressures are mainly determined by the cathode material and the discharge gas type, respectively. Furthermore, the plasma properties are investigated by a double Langmuir probe. The density of the positive pulse plasma is found to be much smaller than that of the negative pulse plasma, although the discharge voltage and current of the negative and positive pulse plasmas are of the same order of magnitude. The positive pulse discharge plasma is considered to quickly diffuse onto the chamber wall from the radially central region due to its high plasma potential compared with that in the peripheral region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic reconnection driven by Gekko XII lasers with a Helmholtz capacitor-coil target

We demonstrate a novel plasma device for magnetic reconnection, driven by Gekko XII lasers irradiating a double-turn Helmholtz capacitor-coil target. Optical probing revealed an accumulated plasma plume near the magnetic reconnection outflow. The background electron density and magnetic field were measured to be approximately 10{sup 18 }cm{sup −3} and 60 T by using Nomarski interferometry and the Faraday effect, respectively. In contrast with experiments on magnetic reconnection constructed by the Biermann battery effect, which produced high beta values, our beta value was much lower than one, which greatly extends the parameter regime of laser-driven magnetic reconnection and reveals its potential in astrophysical plasma applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the role of hydrogen in silicon deposition using an energy-resolved mass spectrometer and a Langmuir probe in an Ar/H{sub 2} radio frequency magnetron discharge

The plasma parameters and ion energy distributions (IED) of the dominant species in an Ar-H{sub 2} discharge are investigated with an energy resolved mass spectrometer and a Langmuir probe. The plasmas are generated in a conventional magnetron chamber powered at 150 W, 13.56 MHz at hydrogen flow rates ranging from 0 to 25 sccm with a fixed argon gas flow rate of 15 sccm. Various H{sub n}{sup +}, SiH{sub n}{sup +}, SiH{sub n} fragments (with n = 1, 2, 3) together with Ar{sup +} and ArH{sup +} species are detected in the discharge. The most important species for the film deposition is SiH{sub n} (with n = 0, 1, 2). H fragments affect the hydrogen content in the material. The flux of Ar{sup +} decreases and the flux of ArH{sup +} increases when the hydrogen flow rate is increased; however, both fluxes saturate at hydrogen flow rates above 15 sccm. Electron density, n{sub e}, electron energy, T{sub e}, and ion density, n{sub i}, are estimated from the Langmuir probe data. T{sub e} is below 1.2 eV at hydrogen flow rates below 8 sccm, and about 2 eV at flow rates above 8 sccm. n{sub e} and n{sub i} decrease with increased hydrogen flow but the ratio of n{sub i} to n{sub e} increases. The formation of H{sup +} ions with energies above 36 eV and electrons with energies greater than 2 eV contributes to the decrease in hydrogen content at hydrogen flow rates above 8 sccm. Analysis of the IEDs indicates an inter-dependence of the species and their contribution to the thin film growth and properties.

36 MATERIALS SCIENCE↗

Measurement of axial neutral density profiles in a microwave discharge ion thruster by laser absorption spectroscopy with optical fiber probes

In order to reveal the physical processes taking place within the ''{mu}10'' microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p{sup 5}({sup 2}P{sup 0}{sub 3/2})6s[{sup 3}/{sub 2}]{sup 0}{sub 2} which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10{sup 18} m{sup -3} order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the {mu}10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of plasma parameters in the vicinity of the Space Shuttle

A Langmuir probe flown as part of the Plasma Diagnostics Package aboard the third Space Shuttle flight was used to determine electron densities, temperatures, and plasma potential in the vicinity of the Shuttle Orbiter. Measurements taken both in the cargo bay and 10 m above the cargo bay on the Remote Manipulator System arm are consistent with small satellite and laboratory results, in that reduced densities and elevated temperatures are observed in the Shuttle wake. The primary difference in the Shuttle measurements is one of magnitude; i.e., orders-of-magnitude density decreases and factor-of-five temperature enhancements. Analysis of data taken in (Delta N)/N turbulence can be as high as a few percent, and the most intense turbulence seems to occur near regions with a steep gradient in plasma pressure.

Murphy, G.↗

The Fixed-Bias Langmuir Probe on the Communication-Navigation Outage Forecast System Satellite: Calibration and Validation

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

Vector Electric Field Instrument↗

Effect of secondary electron emission on the plasma sheath

In this experiment, plasma sheath potential profiles are measured over boron nitride walls in argon plasma and the effect of secondary electron emission is observed. Results are compared to a kinetic model. Plasmas are generated with a number density of 3 × 10{sup 12} m{sup −3} at a pressure of 10{sup −4} Torr-Ar, with a 1%–16% fraction of energetic primary electrons. The sheath potential profile at the surface of each sample is measured with emissive probes. The electron number densities and temperatures are measured in the bulk plasma with a planar Langmuir probe. The plasma is non-Maxwellian, with isotropic and directed energetic electron populations from 50 to 200 eV and hot and cold Maxwellian populations from 3.6 to 6.4 eV and 0.3 to 1.3 eV, respectively. Plasma Debye lengths range from 4 to 7 mm and the ion-neutral mean free path is 0.8 m. Sheath thicknesses range from 20 to 50 mm, with the smaller thickness occurring near the critical secondary electron emission yield of the wall material. Measured floating potentials are within 16% of model predictions. Measured sheath potential profiles agree with model predictions within 5 V (∼1 T{sub e}), and in four out of six cases deviate less than the measurement uncertainty of 1 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of a disk-shaped electron accelerating electrostatic probe

This paper presents a method utilizing the numerical plasma simulation particle-in-cell technique for studying electron accelerating probe characteristics. A probe configuration other than the commonly used plane, cylindrical, or spherical case will be studied; the probe configuration used is that of a disk. Cylindrical geometry is used in the simulation model. One of the advantages of a numerical simulation is the ease with which the details of the system can be examined. Therefore, in addition to the current-voltage characteristics of the static probe, other results are presented such as the time evolution of the plasma properties and studies of the sheath region surrounding the probe.

Nonnast, J. H.↗

Unraveling the surface chemistry processes in lithiated and boronized plasma material interfaces under extreme conditions

The review of recent theoretical and experimental research on the complex surface chemistry processes that evolve from low-Z material conditioning on plasma-facing materials under extreme fusion plasma conditions is presented. A combination of multi-scale computational physics and chemistry modeling with real-time diagnosis of the plasma-material interface in tokamak fusion plasma edge is complemented by ex-vessel in-situ single-effect experimental facilities to unravel the evolving characteristics of low-Z components under irradiation. Effects of the lithium and boron coatings at carbon surfaces to the retention of deuterium and chemical sputtering of the plasma-facing surfaces are discussed in detail. The critical role of oxygen in the surface chemistry during hydrogen-fuel irradiation is found to drive the kinetics and dynamics of these surfaces as they interact with fusion edge plasma that ultimately could have profound effects on fusion plasma confinement behavior. Computational studies also extend in spatio-temporal scales not accessible by empirical means and therefore open the opportunity for a strategic approach at irradiation surface science studies that combined these powerful computational tools with in-vessel and ex-vessel in-situ diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Research progress on ionic plasmas generated in an intense hydrogen negative ion source

Characteristics of ionic plasmas, observed in a high-density hydrogen negative ion source, are investigated with a multi-diagnostics system. The ionic plasma, which consists of hydrogen positive- and negative-ions with a significantly low-density of electrons, is generated in the ion extraction region, from which the negative ions are extracted through the plasma grid. The negative ion density, i.e., the ionic plasma density, as high as the order of 1×10{sup 17}m{sup −3}, is measured with cavity ring-down spectroscopy, while the electron density is lower than 1×10{sup 16}m{sup −3}, which is confirmed with millimeter-wave interferometer. Reduction of the negative ion density is observed at the negative ion extraction, and at that time the electron flow into the ionic plasma region is observed to conserve the charge neutrality. Distribution of the plasma potential is measured in the extraction region in the direction normal to the plasma grid surface with a Langmuir probe, and the results suggest that the sheath is formed at the plasma boundary to the plasma grid to which the bias voltage is applied. The beam extraction should drive the negative ion transport in the ionic plasma across the sheath formed on the extraction surface. Larger reduction of the negative ions at the beam extraction is observed in a region above the extraction aperture on the plasma grid, which is confirmed with 2D image measurement of the Hα emission and cavity ring-down spectroscopy. The electron distribution is also measured near the plasma grid surface. These various properties observed in the ionic plasma are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Propagation of charge-exchange plasma produced by an ion thruster

Under the proper conditions there is an end-effect of a long, cylindrical Langmuir probe which allows a significant increase in collected ion current when the probe is aligned with a flowing plasma. This effect was used to determine the charge-exchange plasma flow direction at various locations relative to the ion thruster. The ion current collected by the probe as a function of its angle with respect to the plasma flow allows determination of the plasma density and plasma flow velocity at the probe's location upstream of the ion thruster optics. The density values obtained from the ion current agreed to within a factor of two of density values obtained by typical voltage-current Langmuir probe characteristics.

Carruth, M. R., Jr.↗

Plasma potential mapping of high power impulse magnetron sputtering discharges

Pulsed emissive probe techniques have been used to determine the plasma potential distribution of high power impulse magnetron sputtering (HiPIMS) discharges. An unbalanced magnetron with a niobium target in argon was investigated for pulse length of 100 μs at a pulse repetition rate of 100 Hz, giving a peak current of 170 A. The probe data were taken with a time resolution of 20 ns and a spatial resolution of 1 mm. It is shown that the local plasma potential varies greatly in space and time. The lowest potential was found over the target’s racetrack, gradually reaching anode potential (ground) several centimeters away from the target. The magnetic pre-sheath exhibits a funnel-shaped plasma potential resulting in an electric field which accelerates ions toward the racetrack. In certain regions and times, the potential exhibits weak local maxima which allow for ion acceleration to the substrate. Knowledge of the local E and static B fields lets us derive the electrons’ E×B drift velocity, which is about 105 m/s and shows structures in space and time.

36 MATERIALS SCIENCE↗

Survey of the Frequency Dependent Latitudinal Distribution of the Fast Magnetosonic Wave Mode from Van Allen Probes Electric and Magnetic Field Instrument and Integrated Science Waveform Receiver Plasma Wave Analysis

We present a statistical survey of the latitudinal structure of the fast magnetosonic wave mode detected by the Van Allen Probes spanning the time interval of 21 September 2012 to 1 August 2014. We show that statistically, the latitudinal occurrence of the wave frequency (f) normalized by the local proton cyclotron frequency (f(sub cP)) has a distinct funnel-shaped appearance in latitude about the magnetic equator similar to that found in case studies. By comparing the observed E/B ratios with the model E/B ratio, using the observed plasma density and background magnetic field magnitude as input to the model E/B ratio, we show that this mode is consistent with the extra-ordinary (whistler) mode at wave normal angles (theta(sub k)) near 90 deg. Performing polarization analysis on synthetic waveforms composed from a superposition of extra-ordinary mode plane waves with theta(sub k) randomly chosen between 87 and 90 deg, we show that the uncertainty in the derived wave normal is substantially broadened, with a tail extending down to theta(sub k) of 60 deg, suggesting that another approach is necessary to estimate the true distribution of theta(sub k). We find that the histograms of the synthetically derived ellipticities and theta(sub k) are consistent with the observations of ellipticities and theta(sub k) derived using polarization analysis.We make estimates of the median equatorial theta(sub k) by comparing observed and model ray tracing frequency-dependent probability occurrence with latitude and give preliminary frequency dependent estimates of the equatorial theta(sub k) distribution around noon and 4 R(sub E), with the median of approximately 4 to 7 deg from 90 deg at f/f(sub cP) = 2 and dropping to approximately 0.5 deg from 90 deg at f/f(sub cP) = 30. The occurrence of waves in this mode peaks around noon near the equator at all radial distances, and we find that the overall intensity of these waves increases with AE*, similar to findings of other studies.

Boardsen, Scott A.↗

A hemispherical Langmuir probe array detector for angular resolved measurements on droplet-based laser-produced plasmas

In this work, a new diagnostic tool for laser-produced plasmas (LPPs) is presented. The detector is based on a multiple array of six motorized Langmuir probes. It allows to measure the dynamics of a LPP in terms of charged particles detection with particular attention to droplet-based LPP sources for EUV lithography. The system design permits to temporally resolve the angular and radial plasma charge distribution and to obtain a hemispherical mapping of the ions and electrons around the droplet plasma. The understanding of these dynamics is fundamental to improve the debris mitigation techniques for droplet-based LPP sources. The device has been developed, built, and employed at the Laboratory for Energy Conversion, ETH Zürich. The experimental results have been obtained on the droplet-based LPP source ALPS II. For the first time, 2D mappings of the ion kinetic energy distribution around the droplet plasma have been obtained with an array of multiple Langmuir probes. These measurements show an anisotropic expansion of the ions in terms of kinetic energy and amount of ion charge around the droplet target. First estimations of the plasma density and electron temperature were also obtained from the analysis of the probe current signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗