Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Compressed baryonic matter—experiments at GSI and FAIR

Experiments on strangeness production in nucleus-nucleus collisions at SIS energies address fundamental aspects of modern nuclear physics: the determination of the nuclear equation-of-state at high baryon densities and the properties of hadrons in dense nuclear matter. Experimental data and theoretical results will be reviewed. The planned “Compressed Baryonic Matter” (CBM) experiment at the future Facility for Antiproton and Ion Research (FAIR) aims at the exploration of the QCD phase diagram at the highest baryon densities. This includes the search for the deconfinement and chiral phase transition and for the QCD critical endpoint. Possible observables and the experimental setup will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and expected perfomance of the MAXI mission for the JEM/ISS

MAXI (Monitor of All-sky X-ray Image) is the first payload to be attached on JEM-EF (Kibo exposed facility) of ISS. It provides an all sky X-ray image every ISS orbit. Only with a few weeks scan, MAXI is expected to make a milli-Crab X-ray all sky map excluding bright region around the sun. Thus, MAXI does not only inform X-ray novae and transients rapidly to world astronomers if once they occur, but also observes long-term variability of Galact ic and extra-Galactic X-ray sources. MAXI also provides an X-ray source catalogue at that time with diffuse cosmic X-ray background. MAXI consists of two kinds of detectors, position sensitive gas-proportional counters for 2-30 keV X-rays and CCD cameras for 0.5-10 keV X-rays. All instruments of MAXI are now in final phase of pre-launching tests of their flight modules. We are also carrying out performance tests for X-ray detectors and collimators. Data processing and analysis software including alert system on ground are being developed by mission team. In this paper we report an overview of final instruments of MAXI and capability of MAXI.

79 ASTRONOMY AND ASTROPHYSICS↗

Contact and Phase-Contrast Imaging of Nanostructures by Femtosecond-Laser-Driven-Cluster-Based Debris-Free Soft X-Ray Source

The high-intensive source of soft X-ray emission was developed by femtosecond laser pulses irradiation of submicron size CO{sub 2} clusters, produced in custom designed super-sonic nozzle while mixing the 10% CO{sub 2}+90% He expanding gases. The LiF crystal soft X-ray detectors have been used for obtaining absorption images of ultrathin (nanoscale) foils and biological structures illuminated by the developed source. It was demonstrated that even if the foil is essentially transparent for the soft X-ray radiation (like 100 nm thick Zr foil), the image contrast could be significantly increased due to the influence of propagation-based phase-contrast effect, by placing the detector at the proper distance from the sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Phase Contrast Imaging with Coded Apertures Using Laboratory-Based X-ray Sources

X-ray phase contrast imaging is a powerful technique that allows detection of changes in the phase of x-ray wavefronts as they pass through a sample. As a result, details not visible in conventional x-ray absorption imaging can be detected. Until recently the majority of applications of phase contrast imaging were at synchrotron facilities due to the availability of their high flux and coherence; however, a number of techniques have appeared recently that allow phase contrast imaging to be performed using laboratory sources. Here we describe a phase contrast imaging technique, developed at University College London, that uses two coded apertures. The x-ray beam is shaped by the pre-sample aperture, and small deviations in the x-ray propagation direction are detected with the help of the detector aperture. In contrast with other methods, it has a much more relaxed requirement for the source size (it works with source sizes up to 100 {mu}m). A working prototype coded-aperture system has been built. An x-ray detector with directly deposited columnar CsI has been used to minimize signal spill-over into neighboring pixels. Phase contrast images obtained with the system have demonstrated its effectiveness for imaging low-absorption materials.

07 ISOTOPE AND RADIATION SOURCES↗

Single-distance nano-holotomography with coded apertures

High-resolution phase-contrast 3D imaging using nano-holotomography typically requires collecting multiple tomograms at varying sample-to-detector distances, usually 3 to 4. This multi-distance approach limits temporal resolution, making it impractical for operando studies. Moreover, shifting the sample complicates reconstruction, requiring precise alignment, registration, and interpolation to correct for shift-dependent magnification on the detector. In response, we propose and validate through simulations a novel, to the best of our knowledge, single-distance approach that leverages coded apertures to structure beam illumination while the sample rotates. Finally, this approach relies on a joint reconstruction scheme, which integrates phase retrieval with 3D tomography, ensuring data consistency and achieving artifact-free reconstructions from a single distance, unlocking dynamic experiments.

Nikitin, Viktor [Argonne National Laboratory (ANL)↗

The NOvA Experiment

The NOνA experiment aims to study the mixing behavior of neutrinos and will attempt to resolve the neutrino mass hierarchy. The experiment will rely on data collected at two detectors, one near Fermilab\'s NuMI (Neutrinos at the Main Injector) target and one 810 km north at Ash River, MN. The detectors are 14 mrad off the beam axis, which results in an almost monoenergetic beam of 2 GeV neutrinos. The construction of the far detector started early this year, the instrumentation will commence this fall, and we hope to take our first data in the beginning of next year. In this talk I will focus on the exciting possibilities of our detector in light of recent neutrino results and will discuss our plans to measure the neutrino mixing angle θ13 as well as to attempt to resolve the neutrino mass hierarchy and to understand the effects of the CP violating phase angle δ. I will also survey the rich physics program provided by our 14 kT fully active far detector, such as searches for magnetic monopoles and detection of supernovaneutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ionization electron signal processing in single phase LArTPCs. Part II. Data/simulation comparison and performance in MicroBooNE

The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PandaX-III: Searching for neutrinoless double beta decay with high pressure 136 Xe gas time projection chambers

Searching for the neutrinoless double beta decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (particle and astrophysical xenon experiment III) will search for the NLDBD of 136 Xe at the China Jin Ping Underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% 136 Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct the electron tracks of the NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure ∼5 m of water shielding in all directions. Furthermore, the second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

TPC↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Macromolecular crystallography with a large format CMOS detector

Recent advances in CMOS technology have allowed the production of large surface area detectors suitable for macromolecular crystallography experiments [1]. The Molecular Biology Consortium (MBC) Beamline 4.2.2 at the Advanced Light Source in Berkeley, CA, has installed a 2952 x 2820 mm RDI CMOS-8M detector with funds from NIH grant S10OD012073. The detector has a 20nsec dead pixel time and performs well with shutterless data collection strategies. The sensor obtains sharp point response and minimal optical distortion by use of a thin fiber-optic plate between the phosphor and sensor module. Shutterless data collections produce high-quality redundant datasets that can be obtained in minutes. The fine-sliced data are suitable for processing in standard crystallographic software packages (XDS, HKL2000, D*TREK, MOSFLM). Faster collection times relative to the previous CCD detector have resulted in a record number of datasets collected in a calendar year and de novo phasing experiments have resulted in publications in both Science and Nature [2,3]. The faster collections are due to a combination of the decreased overhead requirements of shutterless collections combined with exposure times that have decreased by over a factor of 2 for images with comparable signal to noise of the NOIR-1 detector. The overall increased productivity has allowed the development of new beamline capabilities and data collection strategies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of the KM3NeT detector to neutrino fluxes from Galactic point-like sources

The KM3NeT collaboration has started the implementation of the first phase of a cubic-kilometre-scale neutrino telescope in the Northern hemisphere with an integrated platform for Earth and deep sea sciences. The location in the Mediterranean Sea will allow for surveying a large part of the sky, including most of the Galactic Plane and the Galactic Centre, thus complementing the sky coverage of IceCube at the South Pole. Amongst the potential Galactic neutrino sources, SuperNova Remnants are particularly promising since their measured gamma-ray emission extends to several tenths of TeV and exhibits indications for hadronic processes. Assuming a hadronic origin of the gamma-ray emission, the models for neutrino emission from SuperNova Remnants and also from other source types such as pulsars are robustly constrained by gamma-ray measurements. We report expected KM3NeT sensitivities for neutrino fluxes from RXJ1713.7-3946 and Vela X. The sensitivity to point-like sources with a E{sup −2} power law energy spectrum is also reported and compared to the other existing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data quality assurance for the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 7648 Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any Neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. This talk will discuss the various techniques employed to ensure the integrity of the measured spectra. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 × 41 GeV 2 and 18 × 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved Hyperspectral Fluorescence Spectroscopy using Frequency Modulated Excitation

An intensity-modulated excitation light source is used together with a micro channel plate intensified CCD (ICCD) detector gated at a slightly different frequency to generate a beat frequency from a fluorescent sample. The addition of a spectrograph produces a hyperspectral time-resolved data product where the resulting beat frequency is detected with a low frame rate camera. Measuring the beat frequency of the spectrum as a function of time allows separation of the excited fluorescence from ambient constant light sources. The excitation and detector repetition rates are varied over a range of discrete frequencies, and the phase shift of the beat wave maps out the emission decay rate(s).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of pyroelectric signal by continuous ultraviolet illumination of epitaxial Pb(Zr{sub 0.2}Ti{sub 0.8})O{sub 3} films

The pyroelectric signal generated by an epitaxial Pb(Zr{sub 0.2}Ti{sub 0.8})O{sub 3} film can be enhanced by continuous illumination with ultraviolet (UV) light. The measured signal increases more than 2 times at low modulation frequencies of the incident infrared (IR) radiation (∼10 Hz) and at wavelengths where the short-circuit photocurrent presents the maximum value (∼280–300 nm). The tentative explanation is that the changes in polarization induced by the temperature variation under modulated IR illumination are generating a variable internal electric field, able to collect the photogenerated carriers produced under continuous UV illumination leading to an additional signal in phase with the pyroelectric one. This finding could be exploited for designing pyroelectric detectors with enhanced characteristics by combining both UV and IR responses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of β n and spectrum of n = 1 applied fields on fast ion losses in DIII-D

Abstract The effect of n = 1 magnetic perturbations (MPs) on prompt fast ion losses in DIII-D has been investigated using the light ion beam probe technique. The effect of normalized beta, β n , and the plasma response to the MPs is studied for several MP spectra. Magnetics data show a strong dependence of plasma response to β n that depends on the phase difference in perturbation coils, Δ ϕ U L . For most phases, the response increases with β n , however, the response is suppressed for phases between 180 ∘ and 240 ∘ . Experimental data from scintillator based fast ion loss detectors shows that relative fluctuation of lost ions (20%–30% of the steady signal) does not diminish across the L- to H-mode transition for Δ ϕ U L = 240 ∘ , despite the 34% decrease in radial response field and 50% decrease in poloidal response field. Simulations of the DIII-D discharges using M3D-C1 and ASCOT5 find that prompt losses from neutral beam injection in each investigated case hit the first wall at several concentrated locations: the vessel floor, midplane diagnostic ports, vessel ceiling, and inner wall. Simulated losses from co-injection neutral beams are born outside the last closed flux surface, corresponding to radial orbit displacements of 3–6 cm due to the MPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Identification and denoising of radio signals from cosmic-ray air showers using convolutional neural networks

Radio pulses generated by cosmic-ray air showers can be used to reconstruct key properties like the energy and depth of the electromagnetic component of cosmic-ray air showers. Radio detection threshold, influenced by natural and anthropogenic radio background, can be reduced through various techniques. In this work, we demonstrate that convolutional neural networks (CNNs) are an effective way to lower the threshold. We developed two CNNs: a classifier to distinguish radio signal waveforms from background noise and a denoiser to clean contaminated radio signals. Following the training and testing phases, we applied the networks to air-shower data triggered by scintillation detectors of the prototype station for the enhancement of IceTop, IceCube’s surface array at the South Pole. Over a four-month period, we identified 554 cosmic-ray events in coincidence with IceTop, approximately five times more compared to a reference method based on a cut on the signal-to-noise ratio. Comparisons with IceTop measurements of the same air showers confirmed that the CNNs reliably identified cosmic-ray radio pulses and outperformed the reference method. Additionally, we find that CNNs reduce the false-positive rate of air-shower candidates and effectively denoise radio waveforms, thereby improving the accuracy of the power and arrival time reconstruction of radio pulses.

Abbasi, R↗