Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Value of Combined PET/CT for Radiation Planning in CT-Guided Percutaneous Interstitial High-Dose-Rate Single-Fraction Brachytherapy for Colorectal Liver Metastases

Purpose: To determine the additional value of fluorodeoxyglucose-positron emission tomography (PET) for clinical target volume definition in the planning of computed tomography (CT)-guided interstitial brachytherapy for liver metastases. Patients and Methods: A total of 19 patients with liver metastases from colorectal cancer treated in 25 sessions were included in the present study. All patients had undergone fluorodeoxyglucose-PET for patient evaluation before interstitial CT-guided brachytherapy. A contrast-enhanced CT scan of the upper abdomen was obtained for radiation planning. The clinical target volume (CTV) was defined by a radiation oncologist and radiologist. After registration of the CT scan with the PET data set, the target volume was defined again using the fusion images. Results: PET revealed one additional liver lesion that was not visible on CT. The median CT-CTV (defined using CT and magnetic resonance imaging) was 68 cm{sup 3} (range 4-260). The PET/CT-CTV (median, 78 cm{sup 3}; range, 4-273) was significantly larger, with a median gain of 24.5% (interquartile range, 2.1-71.5%; p = .022). An increased CTV was observed in 15 cases and a decrease in 6; in 4 cases, the CT-CTV and PET/CT-CTV were equal. Incomplete dose coverage of PET/CT-CTVs was indicative of early local progression (p = .004); however, CT-based radiation plans did not show significant differences in the local control rates when stratified by dose coverage. Conclusion: Retrospective implementation of fluorodeoxyglucose-PET for CTV specification for CT-guided brachytherapy for colorectal liver metastases revealed a significant change in the CTVs. Additional PET-positive tumor regions with incomplete dose coverage could explain unexpected early local progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Positron Emission Tomography in the Treatment of Occult Disease in Head-and-Neck Cancer: A Modeling Approach

Purpose: To determine under what conditions positron emission tomography (PET) imaging will be useful in decisions regarding the use of radiotherapy for the treatment of clinically occult lymph node metastases in head-and-neck cancer. Methods and Materials: A decision model of PET imaging and its downstream effects on radiotherapy outcomes was constructed using an influence diagram. This model included the sensitivity and specificity of PET, as well as the type and stage of the primary tumor. These parameters were varied to determine the optimal strategy for imaging and therapy for different clinical situations. Maximum expected utility was the metric by which different actions were ranked. Results: For primary tumors with a low probability of lymph node metastases, the sensitivity of PET should be maximized, and 50 Gy should be delivered if PET is positive and 0 Gy if negative. As the probability for lymph node metastases increases, PET imaging becomes unnecessary in some situations, and the optimal dose to the lymph nodes increases. The model needed to include the causes of certain health states to predict current clinical practice. Conclusion: The model demonstrated the ability to reproduce expected outcomes for a range of tumors and provided recommendations for different clinical situations. The differences between the optimal policies and current clinical practice are likely due to a disparity between stated clinical decision processes and actual decision making by clinicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Value of Early [{sup 18}F]Fluoroethyltyrosine Positron Emission Tomography After Radiochemotherapy in Glioblastoma Multiforme

Purpose: Early detection of treatment response in glioma patients after radiochemotherapy (RCX) is uncertain because treatment-related contrast enhancement in magnetic resonance imaging can mimic tumor progression. Positron emission tomography (PET) using the amino acid tracer [{sup 18}F]fluoroethyltyrosine (FET) seems to be a promising tool for treatment monitoring. The aim of this prospective study was to evaluate the prognostic value of early changes of FET uptake after postoperative RCX in glioblastomas. Methods and Materials: Twenty-two patients with glioblastoma were treated by surgery and subsequent RCX (whole dose 60-72 Gy). The FET-PET studies were performed before RCX, 7-10 days and 6-8 weeks after completion of RCX. Early treatment response in PET was defined as a decrease of the maximal tumor-to-brain ratio (TBR{sub max}) of FET uptake after RCX of more than 10%. The prognostic value of early changes of FET uptake after RCX was evaluated using Kaplan-Maier estimates for median disease-free survival and overall survival. Results: The median overall and disease-free survival of the patients was 14.8 and 7.8 months. There were 16 early responders in FET-PET (72.7%) and 6 nonresponders (27.3%). Early PET responders had a significantly longer median disease-free survival (10.3 vs. 5.8 months; p < 0.01) and overall survival ('not reached' vs. 9.3 months; p < 0.001). No statistically significant differences between the patient subgroups were found concerning the defined prognostic parameters. Conclusions: FET-PET is a sensitive tool to predict treatment response in patients with glioblastomas at an early stage after RCX.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defining Radiotherapy Target Volumes Using {sup 18}F-Fluoro-Deoxy-Glucose Positron Emission Tomography/Computed Tomography: Still a Pandora's Box?

Purpose: We discuss the effect of {sup 18}F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) data on target volume definition for radiotherapy planning. We compared the effect of various thresholding methods on the PET-based target volume vs. the standard CT-based tumor volume. Methods and Materials: Different thresholding methods were reviewed and compared to our PET-based gross tumor volume data obtained from a cohort of 31 non-small-cell lung carcinoma patients who had undergone preoperative PET/CT scans for staging. The feasibility and limitations of FDG-based PET/CT data on target volume delineation in radiotherapy planning have been demonstrated with frequently used approaches for target outlining such as the qualitative visual method and the fixed 15% or 40% of the maximal iso-uptake value threshold methods. Results: The relationship between PET-based and CT-based volumes generally suffers from poor correlation between the two image data sets, expressed in terms of a large statistical variation in gross tumor volume ratios, irrespective of the threshold method used. However, we found that the maximal signal/background ratios in non-small-cell lung carcinoma patients correlated well with the pathologic results, with an average ratio for adenocarcinoma, large cell carcinoma, and squamous cell carcinoma of 10.5 {+-} 3.5, 12.6 {+-} 2.8, and 14.1 {+-} 5.9, respectively. Conclusion: The fluctuations in tumor volume using different quantitative PET thresholding approaches did not depend on the thresholding method used. They originated from the nature of functional imaging in general and PET imaging in particular. Functional imaging will eventually be used for biologically tailored target radiotherapy volume definition not as a replacement of CT- or magnetic resonance imaging-based anatomic gross tumor volumes but with the methods complementing each other in a complex mosaic of distinct biologic target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

[{sup 18}F]FDG-Positron Emission Tomography Coregistration With Computed Tomography Scans for Radiation Treatment Planning of Lymphoma and Hematologic Malignancies

Purpose: Positron emission-tomography (PET) using 2-[{sup 18}F]fluoro-2-deoxyglucose (FDG-PET) increases sensitivity and specificity of disease detection in lymphoma and thus is standard in lymphoma management. This study examines the effects of coregistering FDG-PET and computed tomography (CT) (PET/CT) scans on treatment planning for lymphoma patients. Methods and Materials: Twenty-nine patients (30 positive PET scans) underwent PET/CT treatment planning from July 2004 to February 2007 and were retrospectively studied. For each patient, gross tumor volume was blindly contoured on the CT-only and PET/CT studies by a radiation oncologist. Treatment plans were generated for both the CT-only and PET/CT planning target volumes (PTVs) for all patients. Normal tissue doses and PTV coverage were evaluated using dose--volume histograms for all sites. Results: Thirty-two treatment sites were evaluated. Twenty-one patients had non-Hodgkin lymphoma, 5 patients had Hodgkin lymphoma, and 3 patients had plasma cell neoplasms. Previously undetected FDG-avid sites were identified in 3 patients during PET/CT simulation, resulting in one additional treatment field. Due to unexpected PET/CT simulation findings, 2 patients did not proceed with radiation treatment. The addition of PET changed the volume of 23 sites (72%). The PTV was increased in 15 sites (47%) by a median of 11% (range, 6-40%) and reduced in 8 sites (25%) by a median of 20% (range, 6%-75%). In six (19%) replanned sites, the CT-based treatment plan would not have adequately covered the PTV defined by PET/CT. Conclusions: Incorporation of FDG-PET into CT-based treatment planning for lymphoma patients resulted in considerable changes in management, volume definition, and normal tissue dosimetry for a significant number of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Value of Metabolic Tumor Volume and Velocity in Predicting Head-and-Neck Cancer Outcomes

Purpose: We previously showed that metabolic tumor volume (MTV) on positron emission tomography-computed tomography (PET-CT) predicts for disease recurrence and death in head-and-neck cancer (HNC). We hypothesized that increases in MTV over time would correlate with tumor growth and biology, and would predict outcome. We sought to examine tumor growth over time in serial pretreatment PET-CT scans. Methods and Materials: From 2006 to 2009, 51 patients had two PET-CT scans before receiving HNC treatment. MTV was defined as the tumor volume {>=}50% of maximum SUV (SUV{sub max}). MTV was calculated for the primary tumor, nodal disease, and composite (primary tumor + nodes). MTV and SUV velocity were defined as the change in MTV or SUV{sub max} over time, respectively. Cox regression analyses were used to examine correlations between SUV, MTV velocity, and outcome (disease progression and overall survival). Results: The median follow-up time was 17.5 months. The median time between PET-CT scans was 3 weeks. Unexpectedly, 51% of cases demonstrated a decrease in SUV{sub max} (average, -0.1 cc/week) and MTV (average, -0.3 cc/week) over time. Despite the variability in MTV, primary tumor MTV velocity predicted disease progression (hazard ratio 2.94; p = 0.01) and overall survival (hazard ratio 1.85; p = 0.03). Conclusions: Primary tumor MTV velocity appears to be a better prognostic indicator of disease progression and survival in comparison to nodal MTV velocity. However, substantial variability was found in PET-CT biomarkers between serial scans. Caution should be used when PET-CT biomarkers are integrated into clinical protocols for HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variability of Target and Normal Structure Delineation Using Multimodality Imaging for Radiation Therapy of Pancreatic Cancer

Purpose: To explore the potential of multimodality imaging (dynamic contrast–enhanced magnetic resonance imaging [DCE-MRI], apparent diffusion-coefficient diffusion-weighted imaging [ADC-DWI], fluorodeoxyglucose positron emission tomography [FDG-PET], and computed tomography) to define the gross tumor volume (GTV) and organs at risk in radiation therapy planning for pancreatic cancer. Delineated volumetric changes of DCE-MRI, ADC-DWI, and FDG-PET were assessed in comparison with the finding on 3-dimensional/4-dimensional CT with and without intravenous contrast, and with pathology specimens for resectable and borderline resectable cases of pancreatic cancer. Methods and Materials: We studied a total of 19 representative patients, whose DCE-MRI, ADC-DWI, and FDG-PET data were reviewed. Gross tumor volume and tumor burden/active region inside pancreatic head/neck or body were delineated on MRI (denoted GTV{sub DCE}, and GTV{sub ADC}), a standardized uptake value (SUV) of 2.5, 40%SUVmax, and 50%SUVmax on FDG-PET (GTV2.5, GTV{sub 40%}, and GTV{sub 50%}). Volumes of the pancreas, duodenum, stomach, liver, and kidneys were contoured according to CT (V{sub CT}), T1-weighted MRI (V{sub T1}), and T2-weighted MRI (V{sub T2}) for 7 patients. Results: Significant statistical differences were found between the GTVs from DCE-MRI, ADC-DW, and FDG-PET, with a mean and range of 4.73 (1.00-9.79), 14.52 (3.21-25.49), 22.04 (1.00-45.69), 19.10 (4.84-45.59), and 9.80 (0.32-35.21) cm{sup 3} for GTV{sub DCE}, GTV{sub ADC}, GTV2.5, GTV{sub 40%}, and GTV{sub 50%}, respectively. The mean difference and range in the measurements of maximum dimension of tumor on DCE-MRI, ADC-DW, SUV2.5, 40%SUVmax, and 50%SUVmax compared with pathologic specimens were −0.84 (−2.24 to 0.9), 0.41 (−0.15 to 2.3), 0.58 (−1.41 to 3.69), 0.66 (−0.67 to 1.32), and 0.15 (−1.53 to 2.38) cm, respectively. The T1- and T2-based volumes for pancreas, duodenum, stomach, and liver were generally smaller compared with those from CT, except for the kidneys. Conclusions: Differences exists between DCE-, ADC-, and FDG-PET–defined target volumes for RT of pancreatic cancer. Organ at risk volumes based on MRI are generally smaller than those based on CT. Further studies combined with pathologic specimens are required to identify the optimal imaging modality or sequence to define GTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Surveillance Studies for Patients With Stage I to II Diffuse Large B-Cell Lymphoma in the Rituximab Era

Background: The role of surveillance studies in limited-stage diffuse large B-cell lymphoma (DLBCL) in the rituximab era has not been well defined. We sought to evaluate the use of imaging (computed tomography [CT] and positron emission tomography [PET]-CT) scans and lactate dehydrogenase (LDH) in surveillance of patients with stage I to II DLBCL. Methods: A retrospective analysis was performed of patients who received definitive treatment between 2000 and 2013. Results: One hundred sixty-two consecutive patients with stage I to II DLBCL were treated with chemotherapy +/− rituximab, radiation, or combined modality therapy. The 5-year rates of overall survival (OS) and freedom from progression (FFP) were 81.2% and 80.8%, respectively. Of the 162 patients, 124 (77%) were followed up with at least 1 surveillance PET scan beyond end-of-treatment scans; of those, 94 of 124 (76%) achieved a complete metabolic response on PET scan after completion of chemotherapy, and this was associated with superior FFP (P=.01, HR=0.3) and OS (P=.01, HR 0.3). Eighteen patients experienced relapse after initial response to therapy. Nine relapses were initially suspected by surveillance imaging studies (8 PET, 1 CT), and 9 were suspected clinically (5 by patient-reported symptoms and 4 by symptoms and physical examination). No relapses were detected by surveillance LDH. The median duration from initiation of treatment to relapse was 14.3 months among patients with relapses suspected by imaging, and 59.8 months among patients with relapses suspected clinically (P=.077). There was no significant difference in OS from date of first therapy or OS after relapse between patients whose relapse was suspected by imaging versus clinically. Thirteen of 18 patients underwent successful salvage therapy after relapse. Conclusions: A complete response on PET scan immediately after initial chemotherapy is associated with superior FFP and OS in stage I to II DLBCL. The use of PET scans as posttreatment surveillance is not associated with a survival advantage. LDH is not a sensitive marker for relapse. Our results argue for limiting the use of posttreatment surveillance in patients with limited-stage DLBCL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pentaerythritol structure-directing agents bias aluminum siting in MFI zeolites to increase para -xylene selectivity during toluene methylation

MFI zeolites contain ten-membered ring channels (∼0.55 nm diameter) that intersect to form larger voids (∼0.70 nm diameter). The distribution of framework Al sites dictates the void environments that confine active H + sites. MFI synthesized with pentaerythritol (PET) and Na + as structure-directing agents are interrogated using kinetically controlled toluene methylation rates and xylene isomer selectivities. High para-xylene selectivity and low toluene methylation rates indicate that MFI-PET samples contain H + sites predominantly in smaller channels. As-synthesized samples contain more framework Al than Na + , indicating that some charge compensation is provided by protonated PET-solvent complexes that bias Al siting towards these smaller channels.

36 MATERIALS SCIENCE↗

Life cycle analysis of polylactic acids from different wet waste feedstocks

Producing a valuable chemical product through diversion of wet wastes can simultaneously resolve the problems associated with increasing wastes and greenhouse gas emissions from conventional chemical production processes. In this work, we investigated the life-cycle greenhouse gas emissions, water, and fossil-fuel consumption for waste-derived polylactic acids (PLA) from three different waste feedstocks, namely wastewater sludge, food waste, and swine manure, using the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model. The decarbonization potential of replacing fossil-based resins with the waste-derived polymer was also investigated. The results show that swine manure-to-PLA pathway was the least carbon intensive (—1.4 kgCO 2 e/kg) among the three waste-to-PLA pathways on a cradle-to-grave basis, followed by the food waste case (—1.3 kgCO 2 e/kg) and then by the wastewater sludge case (0.6 kgCO 2 e/kg). In the baseline scenario, all three waste-to-PLA pathways were less carbon intensive than both fossil-based PET and HDPE on a cradle-to-grave basis: 66% (vs. PET) and 56% (vs. HDPE), 171 and 192%, 181 and 205% reduction in GHG emissions for wastewater sludge-, food waste-, and swine manure-to-PLA pathway, respectively. For all sensitivity cases investigated, the food waste- and swine manure-to-PLA pathways were significantly less carbon intensive than their fossil-counterparts. In terms of the annual decarbonization potential of replacing fossil-based PET or HDPE, the wastewater sludge- and food waste-pathway showed higher mitigation potential than the swine manure-pathway: i) 18–28 kilotons CO 2 e-reduction per year for wastewater sludge pathway; ii) 23–26 kTCO 2 e-reduction/yr for food waste pathway; and iii) about 5 kTCO 2 e-reduction/yr for swine manure pathway depending on the type of conventional resin replaced. However, given the abundant availability of the swine manure feedstocks across the United States, the decarbonization potential of swine manure-based pathway can also increase as the plant capacity or the number of plants grow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface morphology and photoelectric properties of FTO ceramic thin films under a simple transparent cover-assisted laser annealing

Highlights: • A simple transparent cover-assisted laser annealing method was employed on FTO films. • The presence of coverslip or PET significantly affected the film surface morphology. • Coverslip- or PET-assisted laser annealing greatly increased grain size of the film. • The PET-assisted laser annealed FTO film exhibited the best photoelectric property. - Abstract: A simple transparent cover-assisted laser annealing strategy, which used a coverglass or a PET sheet as the transparent cover, was proposed to improve photoelectric properties of fluorine-doped tin oxide (FTO) thin films. Pure laser annealing was also performed for comparison. Transparent cover-assisted laser annealing was found to be more effective for producing densely distributed particles, decreasing surface roughness and increasing grain size, thus enhancing transmittance and conductivity of the film. More importantly, compared with coverglass-assisted laser annealing, PET-assisted laser annealing enabled the film surface to be covered with more uniform and denser particles and exhibit a remarkable increase in grain size. Therefore the film had the highest total transmittance of 84.32%, the highest specular transmittance of 75.88%, a slightly decreased haze of 10.01% and the lowest sheet resistance of 7.36 Ω/sq. The simple PET-assisted laser annealing method may be a promising substitution for the conventional laser annealing treatment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An investigation into positron emission tomography contouring methods across two treatment planning systems

Positron emission tomography (PET) imaging has been used to provide additional information regarding patient tumor location, size, and staging for radiotherapy treatment planning purposes. This additional information reduces interobserver variability and produces more consistent contouring. It is well recognized that different contouring methodology for PET data results in different contoured volumes. The goal of this study was to compare the difference in PET contouring methods for 2 different treatment planning systems using a phantom dataset and a series of patient datasets. Contouring methodology was compared on the ADAC Pinnacle Treatment Planning System and the CMS XiO Treatment Planning System. Contours were completed on the phantom and patient datasets using a number of PET contouring methods—the standardized uptake value 2.5 method, 30%, 40%, and 50% of the maximum uptake method and the signal to background ratio method. Differences of >15% were observed for PET-contoured volumes between the different treatment planning systems for the same data and the same PET contouring methodology. Contoured volume differences between treatment planning systems were caused by differences in data formatting and display and the different contouring tools available. Differences in treatment planning system as well as contouring methodology should be considered carefully in dose-volume contouring and reporting, especially between centers that may use different treatment planning systems or those that have several different treatment planning systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Unexpected effects of inorganic phosphate glass on crystallization and thermo-rheological behavior of polyethylene terephthalate

The effects of ultra-low glass transition temperature (T g ) phosphate glass (Pglass) on the thermal, morphological, rheological, mechanical, and crystallization properties of hybrid Pglass/poly(eththylene terephthalate)(PET) were investigated. Nano- and micro-scale distribution of the Pglass in the PET polymer matrix was observed. The polydispersed Pglass in the PET matrix functioned as a nucleation agent, resulting in increasing crystallization temperature. The Pglass in the PET matrix decreased the T g , indicating a plasticizing effect of the Pglass in the hybrids that was confirmed by the significantly decreased complex viscosity of the PET matrix. In addition, with increasing temperature, a non-terminal behavior of the viscoelastic properties occurred due to the hybrid structural changes and improved miscibility of the hybrid components. In conclusion, the obtained solid-state variable temperature 31 P and 1 H NMR spectroscopy results showed strong Pglass concentration dependency of the interactions at the PET-Pglass interface.

36 MATERIALS SCIENCE↗

Separation of polyethylene terephthalate from municipal waste plastics by froth flotation for recycling industry

Highlights: • Factors of NaOH treatment were studied by orthogonal and single factor experiments. • Mechanism of alkaline treatment for facilitating flotation was manifested. • Flotation separation of PET was achieved with high purity and efficiency. • A flow sheet of purification PET from MWP was designed. - Abstract: Recycling is an effective way to manage plastic wastes and receives considerable attention. Since plastic mixtures are difficult to recycle because of their intrinsic characteristics, separation of mixed plastics is the key problem for recycling. Separation of polyethylene terephthalate (PET) from municipal waste plastics (MWP) by froth flotation combined with alkaline pretreatment was investigated for recycling industry. The effect of process variables was estimated by L{sub 9} (3{sup 4}) orthogonal array of experiments and single factor experiments. The optimum conditions of alkaline pretreatment are 10 wt% sodium hydroxide, 20 min and 70 °C. After alkaline pretreatment under optimum conditions, flotation separation PET from acrylonitrile–butadiene–styrene, polystyrene, polycarbonate or polyvinyl chloride was achieved with high purity and efficiency. The purity of PET is up to 98.46% and the recovery is above 92.47%. A flow sheet of separation PET from MWP by a combination of froth flotation and sink float separation was designed. This study facilitates industrial application of plastics flotation and provides technical insights into recycling of waste plastics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Production and Evaluation of Fluorophore-Doped Polymer Substrates to Screen for Plastic-Degrading Enzymes

Fast and sensitive analytical methods are the key to efficient screening of plastic-degrading enzymes. Here, we present a streamlined and affordable approach to assess the enzymatic deconstruction of insoluble synthetic polymers by blending them with a fluorescent dye, rhodamine 6G, and we evaluate this screening method using poly(ethylene terephthalate) (PET) as a model material. Our results indicate that enzymatic depolymerization of the rhodamine-doped PET can be observed in a high-throughput fashion by following release of the fluorophore. The fluorescence data obtained during the hydrolysis of rhodamine-doped PET by 14 PET hydrolases, produced with a robotic platform, correlated with the quantitative chromatographic analysis of PET degradation products. Remarkably, the use of the rhodamine-loaded PET substrate resulted in negligibly low background signals even when detecting PETase activity in crude cell lysates, suggesting suitability for screening of a wide variety of samples. Encouraged by these results, we next produced a selection of polyethylene- and nylon-based materials loaded with rhodamine 6G. While rapid leaching of fluorophore observed with nylon substrates limits the utility of the method for detecting nylonase activity, the rhodamine-loaded polyethylene showed promising performance in passive diffusion tests, indicating that this latter substrate may be used to screen for polyolefin-degrading enzymes.

09 BIOMASS FUELS↗

High-Capacity Enzymatic Degradation of Postconsumer Poly(ethylene terephthalate): Modeling and Experimental Investigations

Enzymatic degradation is considered as one of the key steps for biorecycling of polyethylene terephthalate (PET), a widely used plastic. Recently, we have developed an optimized leaf-branch compost cutinase PelB-LCC ICCG and demonstrated ∼80% degradation of 200 g L −1 recycled PET (RPET) within two days in bioreactors. In this study, continued research efforts were made to achieve a complete degradation of up to 300 g L −1 RPET in bioreactors. First, low-capacity reaction conditions with ≤5 g L −1 PET were examined to identify the key variables for PET degradation with PelB-LCC ICCG , including temperature, enzyme loading, and product inhibition. To better understand and further optimize the enzymatic degradation process, a mechanism-based model was established to describe the kinetics of PET degradation and formation of the main product terephthalic acid (TPA) and byproducts MHET and BHET in high-capacity bioreactors. Model simulation suggested that a minimal enzyme loading of ∼1.4 mg PelB-LCC ICCG g −1 RPET is required to achieve a nearly complete degradation of RPET within 48 h, which was used to guide more high-capacity experiments with 100−300 g L −1 RPET in fully controlled 1 L bioreactors. A higher temperature (≥65 °C) was found not only to enable rapid degradation in the beginning but also to induce a gradual increase in RPET’s crystallinity and significantly slow down the degradation after 48 h. A high loading of RPET solids and the accumulation of the produced insoluble TPA pose a big challenge on mixing and mass transfer in the stirred bioreactor, which can be addressed by increasing the stirring speed. The results pave the way toward biorecycling of PET at a large scale.

enzymatic degradation↗

Activated carbons from coal/pitch and polyethylene terephthalate blends for the removal of phenols from aqueous solutions

Blends of two bituminous coals and a coal-tar pitch (CTP) with polyethylene terephthalate (PET) were evaluated as precursors of activated carbons (ACs). The intensity of the interactions between the raw materials, coal/CTP and PET during copyrolysis was closely observed by means of thermogravimetric analysis. In addition, the homogeneity of the carbon matrix of the chars produced at 800{sup o}C in a horizontal oven was studied by polarized light optical microscopy. Activated carbons were prepared from single components and their blends (1:1 w/w) by subjecting them to carbonization up to 800{sup o}C in a horizontal oven and then activation with steam at 800{sup o}C to 50% burnoff. The porous structure of the ACs was determined by sorption of N{sub 2} at 77 K and of CO{sub 2} at 273 K. The PET-containing blends produced microporous activated carbons with a maximum BET surface area of nearly 1100 m{sup 2} g{sup -1} and a maximum micropore size distribution of 0.6-0.8 nm in the case of the AC from the CTP/PET blend. The addition of PET to a bituminous coal was compared with the preoxidation of coal P in air as a way to reduce thermoplasticity and to promote the development of the porous structure. The modification of bituminous coals by PET appeared to be more effective than conventional coal preoxidation treatment. The resultant ACs were tested by measuring their effectiveness in removing phenols from an aqueous solution. The adsorption of p-chlorophenol (PCP) by the ACs prepared from the PET-containing blends was slightly higher than for the commercial activated carbon. The ability to adsorb PCP was found to be related to the volume of the super-micropores.

01 COAL, LIGNITE, AND PEAT↗