Astronomical image-integration system using a television camera tube.
Image orthicon camera tube for detecting faint stars, with photocathode and metal-oxide storage target for c image integration
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Image orthicon camera tube for detecting faint stars, with photocathode and metal-oxide storage target for c image integration
Furnace system operating at 2000 degrees K for determination of IR absorption of high temperature gases
Optical activity in UV region of spectrum developed, using optical rotation to detect extraterrestrial life
Far UV transmitting windows, particularly lithium fluoride, and response measurements below 2000 angstroms, noting fabrication on solar blind materials
Narrow band optical filters, galactic X ray source detectors, AM baseband telemetry, and redundancy removal for telemetry data compressions
Auroral electrons temporal and spatial structure from ground based optical observations and rocket- borne electron detector measurements
A Multispectral Scanner (MSS) has been under development for some time and is now undergoing tests for final calibration. It has four bands, each containing six channels. Thus it has 24 detectors which receive radiation by fiber optics. It is shown that a spherical integrator makes a satisfactory extended source for the calibration of the scanner.
An optical system was developed to provide fast incremental scanning of a backscattered laser velocimeter focus point over a 36-cm distance. The system is used to measure flow velocities at 16 positions along its optical axis and to scan these 16 positions up to 30 times a second. Dwell time at each location is approximately 2 milliseconds. Sample volumes typically are 0.2 mm in diameter by 1.4 cm in length. The optical scanning system consists of a wheel containing plane parallel quartz windows of various thicknesses. The laser velocimeter beams are imaged to a primary focus within the dead airspace of an optical cell. The beams emerging from the cell pass through the windows of the scanning wheel. The refraction of the beams passing through the windows causes an apparent shift of the focus within the optical cell and hence in the test zone. Light scattered from the secondary focus within the test zone is concurrently collected and reimaged through the same optical path which originally projected the primary focus. The reimaged backscattered light containing the velocity information is then collected and focused onto a photomultiplier detector system to complete the scanned laser velocimeter optical system.
Two identical high resolution cameras, capable of attaining a track width of 116 km in an almost vertical line of sight from the two 60 km images of each instrument, will be carried on the initial mission of the space observation of Earth satellite (SPOT). Specifications for the instrument, including the telescope and CCD devices are summarized. The present status of development is described including the optical characteristics, structure and thermal control, detector assembly, electronic equipment, and calibration. SPOT mission objectives include the developments relating to soil use, the exploration of EART Earth resources, the discrimination of plant species, and cartography.
Improvement of the previously reported photocapacitive MIS infrared detectors has led to the development of exceptional room-temperature devices. Unoptimized peak detectivities on the order of 10 to the 13th cm sq rt Hz/W, a value which exceeds the best obtainable from existing solid-state detectors, have now been consistently obtained in Si and GaAs devices using high-capacitance LaF3 or composite LaF3/native-oxide insulating layers. The measured spectral response of representative samples is presented and discussed in detail together with a simple theory which accounts for the observed behavior. The response of an ideal MIS photocapacitor is also contrasted with that of both a conventional photoconductor and a p-i-n photodiode, and reasons for the superior performance of the MIS detectors are given. Finally, fundamental studies on the electrical, optical, and noise characteristics of the MIS structures are analyzed and discussed in the context of infrared-detector applications.
Topographic maps are compiled by manually operated stereoplotters that recreate the geometry of two wide-angle overlapping stereo frame photographs. Continuous imaging systems such as strip cameras, electro-optical scanners, or linear arrays of detectors (push brooms) can also create stereo coverage from which topography can be compiled; however, the instability of an aircraft in the atmosphere makes this approach impractical. The benign environment of space permits a satellite to orbit the Earth with very high stability as long as no local perturbing forces are involved. Solid-state linear-array sensors have no moving parts and create no perturbing force on the satellite. Digital data from highly stabilized stereo linear arrays are amenable to simplified processing to produce both planimetric imagery and elevation data. A proposed satellite, called MAPSAT, could accomplish automated mapping in near real time. Image maps as large as 1:50,000 scale with contours as close as 20-m interval may be produced from MAPSAT data.
The use of grazing incidence optics and reflection grating designs is shown to be a method that improves the performance of spectrographs at wavelengths shorter than 1200 A. Emphasis is laid on spectroscopic designs for X ray and EUV astronomy, with sample designs for an objective reflection grating spectrograph (ORGS) and an echelle spectrograph for wavelengths longer than 100 A. Conical diffraction allows operations at grazing incidence in the echelle spectrograph. In ORGS, the extreme distance of X ray objects aids in collimating the source radiation, which encounters conical diffraction within the instrument, proceeds parallel to the optical axis, and arrives at the detector. A series of gratings is used to achieve the effect. A grazing echelle is employed for EUV observations, and offers a resolution of 20,000 over a 300 A bandpass.
The present investigation is concerned with the development of a high resolution echelle-cross disperser grating spectrograph for application in groundbased, balloon, and Shuttle studies of the middle atmosphere and thermosphere. All the design features discussed pertain specifically to the balloon instrument. Attention is given to examples of scientific objectives for the middle atmosphere, aspects of instrument description, imaging requirements, the spectral multiplexing capability, broad wavelength coverage, sensitivity, dynamic range, scattered light, the optical configuration of the instrument, the detector system, the data system, and the results of laboratory tests and theoretical evaluations.
The novel, relatively high-resolution nebular spectrometer design presented incorporates a mechanical precollimator with an objective echelle grating that proceeds to a cross-dispensing Wadsworth configuration; the minimum feasible number of reflections is employed in order to maximize EUV sensitivity. The configuration, which is noted to be capable of yielding a comparatively large field of view for optimal diffuse emission sensitivity, is compact and employs conventionally fabricated optical components and available microchannel plate detectors. The sensitivities obtainable approach the limit stipulated by Liouville's theorem.
Lidar, an acronym for light detection and ranging, represents a class of instruments that utilize lasers to send probe beams into the atmosphere or onto the surface of the Earth and detect the backscattered return in order to measure properties of the atmosphere or surface. The associated technology has matured to the point where two lidar facilities, Geodynamics Laser Ranging System (GLRS), and Laser Atmospheric Wind Sensor (LAWS) were accepted for Phase 2 studies for Eos. A third lidar facility Laser Atmospheric Sounder and Altimeter (LASA), with the lidar experiment EAGLE (Eos Atmospheric Global Lidar Experiment) was proposed for Eos. The generic lidar system has a number of components. They include controlling electronics, laser transmitters, collimating optics, a receiving telescope, spectral filters, detectors, signal chain electronics, and a data system. Lidar systems that measure atmospheric constituents or meteorological parameters record the signal versus time as the beam propagates through the atmosphere. The backscatter arises from molecular (Rayleigh) and aerosol (Mie) scattering, while attenuation arises from molecular and aerosol scattering and absorption. Lidar systems that measure distance to the Earth's surface or retroreflectors in a ranging mode record signals with high temporal resolution over a short time period. The overall characteristics and measurements objectives of the three lidar systems proposed for Eos are given.
A new infrared array camera system has been successfully applied to high background 5 - 14 micron astronomical imaging photometry observations, using a hybrid 58 x 62 pixel Si:Ga array detector. The off-axis reflective optical design incorporating a parabolic camera mirror, circular variable filter wheel, and cold aperture stop produces diffraction-limited images with negligible spatial distortion and minimum thermal background loading. The camera electronic system architecture is divided into three subsystems: (1) high-speed analog front end, including 2-channel preamp module, array address timing generator, bias power suppies, (2) two 16 bit, 3 microsec per conversion A/D converters interfaced to an arithmetic array processor, and (3) an LSI 11/73 camera control and data analysis computer. The background-limited observational noise performance of the camera at the NASA/IRTF telescope is NEFD (1 sigma) = 0.05 Jy/pixel min exp 1/2.
A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.
The IBEX, with 36 samples of various materials, was placed aboard the LDEF. Twenty-seven of the samples had surfaces modified using ion beam technology, and nine were made up of commercially available materials. The materials are in some way useful in space power systems. The various types of materials tested included six categories: (1) ion beam structured surfaces suitable for solar thermal (concentrator) or space radiators; (2) ion beam sputtered conductive coatings for thermal and space charge control; (3) solar reflector surfaces; (4) flexible thin film coatings and solar array blanket material for protection of spacecraft polymers; (5) painted and/or state-of-the-art solar thermal materials; and (6) micrometeoroid sensitive detector. Data analysis presented include the optical properties of each surface before and after exposure to the space environment and the respective backup surfaces.