The Impact of Refrigerant Charge, Air Flow and Expansion Devices on the Measured Performance of an Air-Source Heat Pump Part I

This paper describes extensive tests performed on a 3-ton R-22 split heat pump in heating mode. The tests contain 150 steady-state performance tests, 18 cyclic tests and 18 defrost tests. During the testing work, the refrigerant charge level was varied from 70 % to 130% relative to the nominal value; the outdoor temperature was altered by three levels at 17 F (-8.3 C), 35 F (1.7 C) and 47 F (8.3 C); indoor air flow rates ranged from 60% to 150% of the rated air flow rate; and the expansion device was switched from a fixed-orifice to a thermal expansion value. Detailed performance data from the extensive steady state cyclic and defrost testing performed were presented and compared.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Improvements for Air Source Heat Pumps using Different Expansion Devices at Varied Charge Levels Part II

This paper describes steady-state performance simulations performed on a 3-ton R-22 split heat pump in heating mode. In total, 150 steady-state points were simulated, which covers refrigerant charge levels from 70 % to 130% relative to the nominal value, the outdoor temperatures at 17 F (-8.3 C), 35 F (1.7 C) and 47 F (8.3 C), indoor air flow rates from 60% to 150% of the rated air flow rate, and two types of expansion devices (fixed orifice and thermostatic expansion valve). A charge tuning method, which is to calibrate the charge inventory model based on measurements at two operation conditions, was applied and shown to improve the system simulation accuracy significantly in an extensive range of charge levels. In addition, we discuss the effects of suction line accumulator in modeling a heat pump system using either a fixed orifice or thermal expansion valve. Last, we identify the issue of refrigerant mass flow mal-distribution at low charge levels and propose an improved modeling approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting reaerosolization

Outdoor studies of the environmental persistence of bacteria have led to many interesting results. It turns out that the initial deposition of bacteria is not the end of the story. We examined both the ongoing daily deposition and aerosolization of bacteria for two weeks following an initial deposition event. Differences between samples collected in a clearing and those collected beneath a forest canopy were also examined. There were two important results: first, bacteria were still moving about in significant quantities after two weeks, though the local environment where they were most prevalent appeared to shift over time; second, we were able to develop a simple mathematical model that could fairly accurately estimate the average daily airborne concentration of bacteria over the duration of the experiment using readily available environmental information. The implication is that deposition patterns are very likely to shift over an extended period of time following a release, possibly quite significantly, but there is hope that we may be able to estimate these changes fairly accurately.

54 ENVIRONMENTAL SCIENCES↗

Loss Prevention Issues in Implementing New Hydrogen Technologies

This paper describes loss prevention issues in implementing hydrogen technologies specifically focusing on hydrogen fueling stations. Hydrogen has been used in industrial applications for many years. In the last ten years, there has been a significant interest in using hydrogen as a vehicle fuel primarily for fuel cell vehicles. The paper will address the following loss prevention associated with hydrogen fueling operations: Hydrogen ignition properties, Hydrogen behavior in confined and semi-confined spaces, High pressure hydrogen storage, and Hydrogen release detection. The paper will address both outdoor fueling operations for road vehicles and indoor fueling operations for industrial trucks. The paper will also discuss outreach Department of Energy (DOE) education activities intended to make users aware of the hazards and safety measures associated with new hydrogen technologies.

08 HYDROGEN↗

Thermal Performance of Uninsulated and Partially Filled Wall Cavities

Wall cavities are widely present in the construction of low rise homes since wood framing is the most common type of construction for residential buildings in the United States. The primary function of such wall construction is to provide a stable frame to which interior and exterior wall coverings can be attached and by which a roof can be supported. The existence of wall cavities increases the thermal resistance of the enclosure, particularly when they are filled with insulating material. Several design guides provide data for prediction of the thermal resistance of uninsulated wall cavities of varying internal geometries. However, U-value coefficients provided in these guides do not account for partially insulated cavities or for variations in aspect ratio. Whole building energy simulation tools, like DOE2 or Energy Plus, use simplified, 1-D characterization of building envelopes. For the most part, this characterization assumes a fixed thermal resistance over the range of temperatures experienced by the enclosure. In reality, the thermal resistance is dominated by convection and radiation and is a function of several parameters, including the temperatures and emissivities of the cavity surfaces and the aspect ratio of the cavity. This study describes detailed CFD modeling to evaluate the thermal performance of uninsulated or partially filled wall cavities accounting for conduction through framing, convection, and radiation. The resulting correlations can serve as input for DOE2 and Energy Plus modeling of older homes, where the walls are either uninsulated or partially insulated due to the settling of the insulating material. Parameters of the study are the ambient temperature outdoors, emissivity of the cavity surfaces, cavity aspect ratio, and height of the insulation level. The outcomes of this study provide: An understanding of the thermal performance of uninsulated or partially insulated wall cavities, which is an essential aspect of energy conservation in residential buildings. Accurate input for whole building simulations models like DOE2 and Energy Plus in various climate zones. Recommendations on retrofit measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TAGGING, TRACKING AND LOCATING WITHOUT GPS

The Savannah River National Laboratory (SRNL) was requested to lead a Law Enforcement Working Group that was formed to collaborate on common operational needs. All agencies represented on the working group ranked their need to tag, track, and locate a witting or unwitting target as their highest priority. Specifically, they were looking for technologies more robust than Global Positioning Satellite (GPS), could communicate back to the owner, and worked where normal cell phone communications did not work or were unreliable. SRNL brought together multiple technologies in a demonstration that was held in in various Alaska venues, including metropolitan, wilderness, and at-sea that met the working group's requirements. Using prototypical technologies from Boeing, On Ramp, and Fortress, SRNL was able to demonstrate the ability to track personnel and material in all scenarios including indoors, in heavily wooden areas, canyons, and in parking garages. In all cases GPS signals were too weak to measure. Bi-directional communication was achieved in areas that Wi-Fi, cell towers, or traditional radios would not perform. The results of the exercise will be presented. These technologies are considered ideal for tracking high value material such has nuclear material with a platform that allows seamless tracking anywhere in the world, indoors or outdoors.

99 GENERAL AND MISCELLANEOUS↗

Quantifying Changes in Building Electricity Use, with Application to Demand Response

We present methods for analyzing commercial and industrial facility 15-minute-interval electric load data. These methods allow building managers to better understand their facility's electricity consumption over time and to compare it to other buildings, helping them to ask the right questions to discover opportunities for demand response, energy efficiency, electricity waste elimination, and peak load management. We primarily focus on demand response. Methods discussed include graphical representations of electric load data, a regression-based electricity load model that uses a time-of-week indicator variable and a piecewise linear and continuous outdoor air temperature dependence, and the definition of various parameters that characterize facility electricity loads and demand response behavior. In the future, these methods could be translated into easy-to-use tools for building managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Introducing an Absolute Cavity Pyrgeometer for Improving the Atmospheric Longwave Irradiance Measurement (Presentation)

Advancing climate change research requires accurate and traceable measurement of the atmospheric longwave irradiance. Current measurement capabilities are limited to an estimated uncertainty of larger than +/- 4 W/m2 using the interim World Infrared Standard Group (WISG). WISG is traceable to the Systeme international d'unites (SI) through blackbody calibrations. An Absolute Cavity Pyrgeometer(ACP) is being developed to measure absolute outdoor longwave irradiance with traceability to SI using the temperature scale (ITS-90) and the sky as the reference source, instead of a blackbody. The ACP was designed by NREL and optically characterized by the National Institute of Standards and Technology (NIST). Under clear-sky and stable conditions, the responsivity of the ACP is determined bylowering the temperature of the cavity and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The absolute atmospheric longwave irradiance is then calculated with an uncertainty of +/- 3.96 W/m2 with traceability to SI. The measured irradiance by the ACP was compared with the irradiance measured by two pyrgeometers calibrated by the WorldRadiation Center with traceability to the WISG. A total of 408 readings was collected over three different clear nights. The calculated irradiance measured by the ACP was 1.5 W/m2 lower than that measured by the two pyrgeometers that are traceable to WISG. Further development and characterization of the ACP might contribute to the effort of improving the uncertainty and traceability of WISG toSI.

47 OTHER INSTRUMENTATION↗

Modeling Population Exposures to Pollutants Emitted from Natural Gas Cooking Burners

We developed a physics-based data-supported model to investigate indoor pollutant exposure distributions resulting from use of natural gas cooking appliances across households in California. The model was applied to calculate time-resolved indoor concentrations of CO, NO2 and formaldehyde resulting from cooking burners and entry with outdoor air. Exposure metrics include 1-week average concentrations and frequency of exceeding ambient air quality standards. We present model results for Southern California (SoCal) using two air-exchange scenarios in winter: (1) infiltration-only, and (2) air exchange rate (AER) sampled from lognormal distributions derived from measurements. In roughly 40percent of homes in the SoCal cohort (N=6634) the 1-hour USEPA NO2 standard (190 ?g/m3) was exceeded at least once. The frequency of exceeding this standard was largely independent of AER assumption, and related primarily to building volume, emission rate and amount of burner use. As expected, AER had a more substantial impact on one-week average concentrations.

03 NATURAL GAS↗

Saving energy and improving IAQ through application of advanced air cleaning technologies

In the future, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates of outdoor air supply) to save energy, with indoor air quality (IAQ) remaining constant or even improved. The opportunity is greatest for commercial buildings because they usually have a narrower range of indoor pollutant sources than homes. This article describes the types of air cleaning systems that will be needed in commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equivalence in Ventilation and Indoor Air Quality

We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Advanced Boiler Load Monitoring Controls, Chicago, Illinois

Most of Chicago’s older multifamily housing stock is heated by centrally metered steam or hydronic systems. The cost of heat is typically absorbed into the owner’s operating cost and is then passed to tenants. Central boilers typically have long service lifetimes; the incentive for retrofit system efficiency upgrades is greater than equipment replacement for the efficiency-minded owner. System improvements as the “low-hanging fruit” are familiar, from improved pipe insulation to aftermarket controls such as outdoor temperature reset (OTR) or lead/lag controllers for sites with multiple boilers. Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. In this project, the Building America team Partnership for Advanced Residential Retrofit (PARR) installed and monitored an ALM aftermarket controller, the M2G from Greffen Systems, at two Chicago area multifamily buildings with existing OTR control. Results show that energy savings depend on the degree to which boilers are oversized for their load, represented by cycling rates. Also, savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, oversized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less oversized boilers at another site showed muted savings.

Building America↗

Traceable Pyrgeometer Calibrations

This poster presents the development, implementation, and operation of the Broadband Outdoor Radiometer Calibrations (BORCAL) Longwave (LW) system at the Southern Great Plains Radiometric Calibration Facility for the calibration of pyrgeometers that provide traceability to the World Infrared Standard Group.

14 SOLAR ENERGY↗

Traceable Pyrgeometer Calibrations

This presentation provides a high-level overview of the progress on the Broadband Outdoor Radiometer Calibrations for all shortwave and longwave radiometers that are deployed by the Atmospheric Radiation Measurement program.

14 SOLAR ENERGY↗

Methods for Service Life Time Estimation of Aluminum Reflectors

In order to reduce electricity generation costs of concentrating solar power (CSP) technologies, new low-cost reflector materials are being developed. These materials need to withstand difficult outdoor conditions without a significant loss in specular reflectance. In this work, samples of enhanced anodized aluminum reflectors protected by a sol-gel coating exposed at different weathering siteshave been analyzed with an innovative specular reflectometer and accelerated aging tests have been carried out in order to estimate the service lifetime. A new accelerated aging procedure is proposed, which consists in combining abrasion and corrosion testing.

14 SOLAR ENERGY↗

Better Buildings Alliance Site (Parking Lot) Lighting

This resource describes DOE's efforts to support the market introduction of LED parking lot lighting by making reliable, energy-efficient, and competitively priced outdoor LED lighting systems more widely available in the marketplace and with the LED Site Lighting Specification.

LED, parking lot, lighting, outdoor lighting, site↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Radioactive contamination from 1920-50's at an urban site of the New York City and interim remedial action - 15630

The former Wolff-Alport Chemical Company operated at the location in densely populated urban area in Queens, New York, between 1920 to about 1954. The company imported, stored on-site and processed monazite sand ores from the Belgium Congo. The extracted refined products enriched in rare-earth metals were sold on the commercial market. The process residues, rich in thorium and its progeny, were originally disposed of directly to the city sewer line and probably on-site also. The site's buildings are currently occupied by the auto shops, corner delicatessen store, light construction company, ice maker/distributor, and two residential apartments. Preliminary site investigations found multiple areas with elevated levels of direct gamma radiation with the maximum reported rates of 22 micro-sievert/hour (2.2 milli-rem/hour) at surface level and 40 micro-sievert/hour (4 milli-rem/hour) inside sewer manhole access. The thoron (Rn-220) gas air concentration in outdoor areas was reported reaching 13.5 kBq/m{sup 3} (366 pCi/L) and the radon (Rn-222) gas air concentrations was reported exceeding 148 Bq/ m{sup 3} (4 pCi/L) in some buildings. The dose assessments indicated that, under realistic scenarios, some members of the public were likely to receive the radiation exposure from this contamination in excess of the New York City and Nuclear Regulatory Commission general public radiation dose limit of 1 milli-sievert /yr (100 milli-rem/yr). The interim remedial action was planned and conducted by the U.S. Environmental Protection Agency (U.S. EPA) Region 2 in close cooperation with the New York City and New York State in 2012-13. The purpose of the action was to take necessary interim measures to reduce annual public dose below limit of 1 milli-sievert/yr (100 milli-rem/yr) and reduce radon gas concentration levels in impacted indoor spaces below U.S. EPA Action Level for residencies of 148 Bq/ m{sup 3} (4 pCi/L). In order to achieve these goals, the following actions were taken: detailed radiological and occupancy surveys; development of realistic exposure scenarios; dose assessments; installation of the fence and gates around the 'backyard' portion of the site; vegetation removal; development and detailed assessment of the radiation shielding options; application of the multilayer radiation shielding in some buildings, portions of the sidewalk and unpaved areas; mitigation of radon/thoron gas entry point; and installation of the radon mitigation system in one of the buildings. The preliminary post-action analyses indicated that the action goal would likely be achieved. The interim remedial action was conducted in a tight urban setting; it has significantly reduced public health risk from radiation without closure of businesses that continued operating within the site perimeter. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗