Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

The design of optimum remote-sensing instruments

Remote-sensing instruments allow values for certain properties of a target to be retrieved from measurements of radiation emitted, reflected or transmitted by the target. The retrieval accuracy is affected by random variations in the many target properties which affect the measurements. A method is described, by which statistical properties of the target and theoretical models of its electromagnetic behavior can be used to choose values for the instrument parameters which maximize the retrieval accuracy. The technique is applicable to a wide range of remote-sensing instruments.

Peckham, G. E.↗

The development of a high-capacity instrument module heat transport system, appendixes

Data sheets provide temperature requirements for 82 individual instruments that are under development or planned for grouping on a space platform or pallet. The scientific objectives of these instrument packages are related to solar physics, space plasma physics, astronomy, high energy astrophysics, resources observations, environmental observations, materials processing, and life sciences. System specifications are given for a high capacity instrument module heat transport system to be used with future payloads.

Source record↗

The Development of an Airborne Instrumentation Computer System for Flight Test

Instrumentation interfacing frequently requires the linking of intelligent systems together, as well as requiring the link itself to be intelligent. The airborne instrumentation computer system (AICS) was developed to address this requirement. Its small size, approximately 254 by 133 by 140 mm (10 by 51/4 by 51/2 in), standard bus, and modular board configuration give it the ability to solve instrumentation interfacing and computation problems without forcing a redesign of the entire unit. This system has been used on the F-15 aircraft digital electronic engine control (DEEC) and its follow on engine model derivative (EMD) project and in an OV-1C Mohawk aircraft stall speed warning system. The AICS is presently undergoing configuration for use on an F-104 pace aircraft and on the advanced fighter technology integration (AFTI) F-111 aircraft.

Glenn A Bever↗

Purging sensitive science instruments with nitrogen in the STS environment

Potential contamination of extremely sensitive science instruments during prelaunch, launch, and earth orbit operations are a major concern to the Galileo and International Solar Polar Mission (ISPM) Programs. The Galileo Program is developing a system to purify Shuttle supplied nitrogen gas for in-flight purging of seven imaging and non-imaging science instruments. Monolayers of contamination deposited on critical surfaces can degrade some instrument sensitivities as much as fifty percent. The purging system provides a reliable supply of filtered and fried nitrogen gas during these critical phases of the mission when the contamination potential is highest. The Galileo and ISPM Programs are including the system as Airborne Support Equipment (ASE).

Lumsden, J. M.↗

Design trade-offs for a multispectral linear array (MLA) instrument

The NASA Landsat program with imagery produced by the Multispectral Scanner has been thoroughly successful. The second generation of Landsat is represented by the Thematic Mapper, while the MLA sensor belongs to a third generation. It is pointed out that the strength of the MLA concept emanates from the pushbroom image-formation approach, which offers some fundamental improvements over opto-mechanically scanned instruments. The increased dwell time of the MLA sensor can be employed to improve signal-to-noise, spectral resolution, and spatial resolution simultaneously. Problems regarding design tradeoffs are considered, taking into account instrument sizing, configuration tradeoffs, optical design tradeoffs, aspects of spectral separation and registration, and radiometric accuracy and calibration tradeoffs. A description is provided of the instrument concept to which the design tradeoffs have led.

Mika, A. M.↗

Two-year solid hydrogen cooler for the Cryogenic Limb Array Etalon Spectrometer (CLAES) instrument

The Cryogenic Limb Array Etalon Spectrometer (CLAES) will be one of thirteen instruments on board the Upper Atmospheric Research Satellite (UARS) in late 1988. CLAES is to be employed for the measurement of stratospheric trace species concentrations affecting the ozone layer balance. It is an earth-limb viewing instrument which requires cryogenic cooling in order to obtain the necessary performance sensitivity. The present investigation is concerned with the solid hydrogen cryogen subsystem which provides the instrument temperature needed. Attention is given to the studies which led to the selection of solid hydrogen as cooling agent, the baseline cooler system, aspects of baseline performance sensitivity, and nominal cooler operations.

Naes, L. G.↗

Comparison of measurements by different instruments of the far-infrared reflectance of rough, optically black coatings

Two comparisons of available specular infrared measurements using identical or very similar coatings reveal that specular BRDF (bidirectional reflectance distribution function) measurements of rough coatings are comparable but that simple measured reflectances are not. This is seen as indicating that the diffuse component of the measured specular reflectance is significantly larger than that of the specular component. It is noted that the diffuse component of the measurement is a convolution of the intrinsic directional reflectivity of the surface with the instrument function and that because the value of that function increases at the wavelengths under consideration, the diffuse component is larger than would otherwise be expected. The BRDF normalization is found to cause a primitive deconvolution of the instrument function and to produce a quantity that is approximately equal to the mean intrinsic directional reflectivity very near the specular direction. The analysis and comparison of data reveal that nonspecular BRDF measurements at angles well outside the instrument function can be calibrated as well by an image of the source upon the detector as by reference to a known surface.

Smith, S. M.↗

MLA instrument concepts for future land remote sensing

The evolution of various Multispectral Linear Array (MLA) sensor concepts occurred over the past several years in response to a corresponding evolution in mission requirements. Initial efforts were concered with sensors for an Operational Land Observation System (OLOS), with free-flying spacecraft at a principal altitude of 705 km. In 1982, studies related to the definition of instruments for an Experimental Land Observation System (ELOS) were conducted. The ELOS mission involves a series of Space-Shuttle sortie flights. The ELOS MLA instrument is to perform two roles. It is to be a key tool for conducting science experiments from the Shuttle, and it is to demonstrate the technology for an eventual free-flying spacecraft. Attention is given to MLA instrument-design concepts, efforts regarding the development of sensors with many narrow spectral bands, and aspects of technology development.

Mika, A. M.↗

Instrumentation for Application Number 1: Mass Spectrometric Analysis of the Boundary Layer Associated with the Tethered Satellite

Knowledge about the boundary layer associated with high enthalpy flow fields has mostly been derived from measurements of physical properties. To further this understanding, the chemistry of the gaseous layer must be studied as well. This requires that instrumentation and measurement methods be developed that can analyze the gases while having a minimal effect on the flow field and composition. Because of its sensitivity and ability to identify species, the mass spectrometer is the most promising instrument for this application, although other spectroscopic methods are being evaluated as well. There are, however, several non-trivial problems that must be solved in order to apply the mass spectrometer, including the obtaining of a representative sample from near the model surface. These problems are being addressed in a research program to develop qualitative and quantitative measurement methods to examine the gas chemistry in several large hot-gas blowdown facilities, and to study the aerodynamics of the boundary layer associated with models in these facilities and in instrumented hypersonic vehicles. These methods can also be applied to the tethered satellite, which will provide a unique opportunity to obtain aerothermodynamic data that is unaltered by effects from the test facility.

Wood, G. M.↗

The Fourier Tachometer 2: an Instrument for Measuring Global Solar Velocity Fields

The High Altitude Observatory and Sacramento Peak Observatory have jointly constructed a second version of the Fourier Tachometer, which is now undergoing final integration and testing. This is an interferometric instrument for measuring the Doppler shift of solar spectrum lines. The principal features and performance goals of this instrument are: simultaneous velocity observations over a 2-dimensional, 100 x 100 pixel field of view; measurement of absolute Doppler shifts with 1 m/s accuracy; noise level for moderate-1 oscillation modes of 1 cm/s for a 1-day observing run; flexibility and ease of use. Early (though incomplete) testing suggests that these goals should be attainable with the current instrument.

Brown, T. M.↗

Instrumentation technology overview

The Instrumentation Technology program advances the state of the art of instrumentation associated with the SSME to improve service life and performance by providing increased measurement capability. Two broad categories of instrumentation technology are sought. The first category includes sensors and systems destined to be used in and on the operational engine either during operation or between operations. These measurements supply information necessary for engine control and/or diagnostics throughout the life of the engine. The second category includes measurement systems and techniques whose application will be to engine component test stands and possibly to the test bed engine. The measurements provide the detailed information necessary to verify computer models of the performance of the various engine subsystems.

Nieberding, W. C.↗

High energy gamma ray balloon instrument

The High Energy Gamma Ray Balloon Instrument was built in part to verify certain subsystems' performance for the Energetic Gamma Ray Experiment Telescope (EGRET) instrument, the high energy telescope to be carried on the Gamma Ray Observatory. This paper describes the instrument, the performance of some subsystems, and some relevant results.

Thompson, D. J.↗

Future remote sensing instruments and systems

Scientific requirements for terrestrial remote-sensing satellites in the 1990's and instrument packages to meet them are discussed, summarizing the results of a preliminary study conducted by the NASA System Z Science and Mission Requirements Working Group. Major questions regarding atmospheric chemistry and circulation, global climate, ocean dynamics, biogeochemical cycles, ice-budget and hydrological cycles, continental geology, biomass dynamics, and land cover and use are listed along with the observational frequency and resolution necessary to answer them, and an instrument use matrix is presented. Large essentially permanent man-tended arrays of instruments serving multiple functions and linked to the users via advanced information-processing networks and (possibly including expert systems) are recommended, and a basic payload and two supplemental packages are outlined.

Broome, D. R., Jr.↗

Airborne Imaging Spectrometer - An advanced concept instrument

The Airborne Imaging Spectrometer (AIS) is a multispectral infrared imaging instrument utilizing a 32- x 32-element mercury-cadmium-telluride detector array to achieve high spatial resolution. A novel optical design provides high spectral resolution, and, in conjunction with the 32-element spatial resolution, makes optimal use of the capabilities of the area array. The experiment requirements and the details of instrument design, implementation, and calibration are presented. The superior resolution, accuracy, and data acquisition rate of this sensor/instrument concept for reconnaissance and geophysical survey is detailed and plans for upgrading/improving the instrument and future applications of this design concept are discussed.

Labaw, C.↗

Enhanced ion outflows measured by the DE 1 high altitude plasma instrument in the dayside plasmasphere during the recovery phase

Ion flow velocities both parallel and perpendicular to the magnetic field, and including the effects of spacecraft charging and spacecraft velocity, have been measured during the recovery phase of two large magnetic storms on October 14 and 21 of 1981. These measurements were made both inside and outside the plasmasphere and indicate unreported yet substantial outflows of ions within the dayside plasmasphere (October 14). Combined data from instruments on board the Dynamics Explorer satellite, including the high altitude plasma instrument, the energetic ion composition spectrometer, the retarding ion mass spectrometer, and the plasma wave instrument, indicate that these ions are most likely dominantly O(+) at energies at least as low as 5 eV. The nightside pass (October 21), which occurred during the recovery phase of a similar storm, showed no plasmaspheric outflows. The results indicate that a large contribution to the outflux into the dayside plasmasphere during the recovery period is due to E greater than 5 eV ions.

Menietti, J. D.↗

Comparison of mesospheric ozone measurements using the LRIR and UVMCS satellite instruments

A comparison between mesospheric ozone profiles determined by two radically different satellite-borne instruments is presented for the period of July to November, 1975. The Limb Radiance Inversion Radiometer measured 9.6-micron O3 emission, while the Ultraviolet Multiple Channel Spectrometer measured the atmospheric attenuation of solar ultraviolet radiation during passage of the OSO-8 satellite across the terminator. Only nine near coincident measurements were found. The individual instruments have estimated precision errors of + or - 10 to 15 percent. Agreement between ozone values as measured by the two techniques for specific cases varies between 10 and 20 percent. The statistical correlation is positive and significant at all altitudes where both instruments had reasonable signal-to-noise ratio. A maximum correlation of 0.76 occurred at 0.3 mb (about 59 km).

Millier, F.↗

Impact dynamics instrumentation

One of the tasks specified in the NASA Langley controlled impact demonstration (CID) work package was to furnish dynamic instrumentation sensors. The types of instrumentation sensors required were accelerometers for aircraft structural loads measurements, seat belt load cells to measure anthropomorphic dummy responses to the aircraft impact, and strain gage bending bridges to measure the aircraft fuselage and wing bending during impact. The objective in the selection of dynamic instrumentation for the CID was to provide 352 of the highest quality transducers and remain within budget allocation. The transducers that were selected for the CID evaluation process were each subjected to rigorous laboratory acceptance tests and to aircraft fuselage section drop tests at the LaRC Impact Dynamics Research Facility. Data compiled from this series of tests showed the selected transducers to be best suited for the CID mission requirement. The transducers installation technique on the airframe proved successful. The transducer quality assurance was guaranteed through rigorous acceptance testing. Data acquired was 97.0%.

Mccormck, R. F.↗

Instrument intercomparisons and assessments

Over the past few years, several field campaigns were devoted to the goal of assessing instrument reliability, as opposed to solely obtaining data to answer a geophysical question. Some examples of the formal instrument intercomparisons that have occurred in the past decade and those that are planned for the very near future are listed chronologically. Balloon-borne techniques and instruments that address the height profiles of the trace species in the lower stratosphere are emphasized. Beginning with the most extensively studied trace constituent, the approach taken and the results obtained, are described. The current status of the measurement capabilities are summarized, and the needs for future intercomparisons and assessments are listed.

Albritton, D. L.↗