Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Data Sensitivities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Exploring the QCD phase diagram through correlations and fluctuations

The exploration of the Quantum Chromodynamics (QCD) phase diagram is a central goal of relativistic heavy-ion collision experiments. This review focuses on the role of fluctuations and correlations as sensitive probes of the phase structure. We discuss theoretical advancements and experimental methodologies employed to map the QCD phase diagram, highlighting constraints derived from both lattice QCD calculations and existing experimental data. Key observables such as cumulants and factorial cumulants of conserved charges (e.g., net-proton, net-charge) are explored as promising signatures of phase transitions and the QCD critical point. We discuss how these quantities are measured experimentally and compared with theoretical predictions, addressing challenges and best practices for meaningful comparisons. Special attention is given to predictions and current experimental results at high baryon density, including recent findings from the STAR collaboration at RHIC. Finally, we identify open issues and future directions for fluctuation and correlation studies at lower collision energies, relevant for future measurements, for example by the CBM experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DECOVALEX-2023: Task F2 Salt Final Report

The subject of Task F of DECOVALEX-2023 concerns performance assessment modelling of radioactive waste disposal in deep mined repositories. The primary objectives of Task F are to build confidence in the models, methods, and software used for performance assessment (PA) of deep geologic nuclear waste repositories, and/or to bring to the fore additional research and development needed to improve PA methodologies. In Task F2- (salt), these objectives have been accomplished through staged development and comparison of the models and methods used by participating teams in their PA frameworks. Coupled-process submodels and deterministic simulations of the entire PA model for a reference scenario for waste disposal in domal salt have been conducted. The task specification has been updated continuously since the initiation of the project to reflect the staged development of the conceptual repository model and performance metrics. Thermal, hydrological, mechanical, and chemical properties of individual components of the engineered and natural system were chosen for relevance by participating teams. The salt reference case system was characterized using data and measurements collected at relevant underground research laboratories (URLs), field sites, and simulation results from teams with specialized modelling capability. Participating teams made a wide range of model assumptions from compartmentalized networks to full 3D models of the salt formation. No single contributed model includes full-fidelity representation of all the features, events, and processes (FEPs) detailed in the task specification, but almost all features and processes are represented in at least one model. Despite differences in the modelling strategies developed by participating teams, all models indicate that salt compaction and radionuclide diffusion are key processes in the repository, and for the FEPs and model scenario considered, little of the disposed radionuclides will migrate beyond the repository seal over the 100,000 year simulations. In general, the model output quantities have the largest differences over the short term and near the waste. The models tend to be more similar further from waste and at later time. Disparities between the models are believed to be due to differing simplifications from the task specification, some of which are chosen simplifications to reduce complexity, and some are restrictions imposed by the modelling tools. A second round of this task has been accepted for DECOVALEX-2027 in conjunction with Task F1 on crystalline PA modelling. The future round includes waste package heating, improved modelling of salt creep closure, additional comparisons of coupled-process sub-models, and the impact of repository engineering design on radionuclide migration in the repository. Participants will also propose and finalize a set of uncertain inputs for the reference case simulations, propagate these uncertainties in a set of realizations, and conduct sensitivity analyses on the simulation results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surrogate-driven design optimization with uncertainty constraints in Monte Carlo simulations

In multi-objective design tasks, the computational cost increases rapidly when high-fidelity simulations are used to evaluate objective functions. Surrogate models help mitigate this cost by approximating the simulation output, simplifying the design process. However, under high uncertainty, surrogate models trained on noisy data can produce inaccurate predictions, as their performance depends heavily on the quality of training data. This study investigates the impact of data uncertainty on two multi-objective design problems modelled using Monte Carlo transport simulations: a neutron moderator and an ion-to-neutron converter. For each, a grid search was performed using five different tally uncertainty levels to generate training data for neural network surrogate models. These models were then optimized using NSGA-III. The recovered Pareto-fronts were analyzed across uncertainty levels: in the moderator problem, normalized hypervolume dropped from 0.886 at 1.0% uncertainty to 0.748 at 10% uncertainty, while in the converter problem it remained near 0.50 for all cases. Average simulation times were also compared to evaluate the trade-off between accuracy and computational cost. Results show that the influence of simulation uncertainty is strongly problem-dependent. In the neutron moderator case, higher uncertainties led to exaggerated objective sensitivities and distorted Pareto-fronts, reducing normalized hypervolume. In contrast, the ion-to-neutron converter task was less affected—low-fidelity simulations produced results similar to those from high-fidelity data. These findings suggest that a fixed-fidelity approach is not optimal. Surrogate models can recover the Pareto-front under noisy conditions, and multi-fidelity studies help identify suitable uncertainty levels for each problem to balance efficiency and accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

Multiplexed Readout for an Experiment with a Large Number of Channels Using Single-Electron Sensitivity Skipper-CCDs

This paper presents the implementation of a multiplexed analog readout electronics system that can achieve single-electron counting using Skipper-CCDs with non-destructive readout. The proposed system allows the best performance of the sensors to be maintained, with sub-electron noise-level operation, while maintaining low-bandwidth data transfer, a minimum number of analog-to-digital converters (ADC) and low disk storage requirement with zero added multiplexing time, even for the simultaneous operation of thousands of channels. These features are possible with a combination of analog charge pile-up, sample and hold circuits and analog multiplexing. The implementation also aims to use the minimum number of components in circuits to keep compatibility with high-channel-density experiments using Skipper-CCDs for low-threshold particle detection applications. Performance details and experimental results using a sensor with 16 output stages are presented along with a review of the circuit design considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A NICER view of PSR J0030+0451: Implications for the Dense Matter Equation of State

Both the mass and radius of the millisecond pulsar PSRJ0030+0451 have been inferred via pulse-profile modeling of X-ray data obtained by NASA’s Neutron Star Interior Composition Explorer (NICER) mission. In this Letter we study the implications of the mass–radius inference reported for this source by Riley et al. for the dense matter equation of state (EoS), in the context of prior information from nuclear physics at low densities. Using a Bayesian framework we infer central densities and EoS properties for two choices of high-density extensions: a piecewise-polytropic model and a model based on assumptions of the speed of sound in dense matter. Around nuclear saturation density these extensions are matched to an EoS uncertainty band obtained from calculations based on chiral effective field theory interactions, which provide a realistic description of atomic nuclei as well as empirical nuclear matter properties within uncertainties. We further constrain EoS expectations with input from the current highest measured pulsar mass; together, these constraints offer a narrow Bayesian prior informed by theory as well as laboratory and astrophysical measurements. The NICER mass–radius likelihood function derived by Riley et al. using pulse-profile modeling is consistent with the highest-density region of this prior. The present relatively large uncertainties on mass and radius for PSR J0030+0451 offer, however, only a weak posterior information gain over the prior. We explore the sensitivity to the inferred geometry of the heated regions that give rise to the pulsed emission, and find a small increase in posterior gain for an alternative (but less preferred) model. Lastly, we investigate the hypothetical scenario of increasing the NICER exposure time for PSRJ0030+0451.

G Raaijmakers↗

Progenitors and explosion properties of supernova remnants hosting central compact objects: II. A global systematic study with a comparison to nucleosynthesis models

ABSTRACT Core-collapse explosions of massive stars leave behind neutron stars, with a known diversity that includes the ‘Central Compact Objects’ (CCOs). Typified by the neutron star discovered near the centre of the Cas A supernova remnant (SNR), CCOs have been observed to shine only in X-rays. To address their supernova progenitors, we perform a systematic study of SNRs that contain a CCO and display X-ray emission from their shock-heated ejecta. We make use of X-ray data primarily using the Chandra X-ray observatory, complemented with XMM–Newton. This study uses a systematic approach to the analysis of each SNR aimed at addressing the supernova progenitor as well as the explosion properties (energy and ambient density). After fitting for the ejecta abundances estimated from a spatially resolved spectroscopic study, we compare the data to six nucleosynthesis models making predictions on supernova ejecta yields in core-collapse explosions. We find that the explosion models commonly used by the astrophysics community do not match the ejecta yields for any of the SNRs, suggesting additional physics, for example multidimensional explosion models or updated progenitor structures, are required. Overall we find low-mass (≤25 solar masses) progenitors among the massive stars population and low-energy explosions (<1051 ergs). We discuss degeneracies in our model fitting, particularly how altering the explosion energy affects the estimate of the progenitor mass. Our systematic study highlights the need for improving on the theoretical models for nucleosynthesis predictions as well as for sensitive, high-resolution spectroscopy observations to be acquired with next generation X-ray missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal loading analysis of the ring injection dump for the Spallation Neutron Source facility

The ring injection dump (RID) is the largest beam dump in the Spallation Neutron Source facility at Oak Ridge National Laboratory and accepts a fraction of the beam from the ring that is not captured in the ring during injection. Thermo-fluid modeling of the RID components was performed during the initial design by using the software ANSYS CFX to characterize the power rating for the RID. From the calculations, the power rating was lowered from 200 kW to 150 kW, at 1.3 GeV beam energy due to concerns regarding the heating of the concrete structure. The Proton Power Upgrade project scope included reevaluating the power limit to the RID in anticipation that increasing it would provide more operational flexibility. The focus was on the shielding because it was the limiting factor, and data collected from thermocouples installed on the structure were used to benchmark the analysis. A three-stage process was adopted in the latest study. First, the already existing steady-state calculations were validated and extended with the latest Monte Carlo N-Particle source term calculations. Second, transient calculations were conducted to capture the dynamic state of the system in response to the energy dumped to the RID during the following operational period of the beam from 2005–2019 (14 years), and sensitivity analyses of crucial parameters were performed to benchmark the model with reasonable accuracy. Finally, an idealized transient cycle analysis was conducted with realistic duty factors to predict the temperature distribution at higher beam powers. Overall, the results confirmed the accuracy of the original steady state model but allowed the development of a new validated transient model with higher accuracy for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on hadron resonance gas interactions via first-principles Lattice QCD susceptibilities

We investigate extensions of the Hadron Resonance Gas (HRG) Model beyond the ideal case by incorporating both attractive and repulsive interactions into the model. When considering additional states exceeding those measured with high confidence by the Particle Data Group, attractive corrections to the overall pressure in the HRG model are imposed. On the other hand, we also apply excluded-volume corrections, which ensure there is no overlap of baryons by turning on repulsive (anti)baryon-(anti)baryon interactions. We emphasize the complementary nature of these two extensions and identify combinations of conserved charge susceptibilities that allow us to constrain them separately. In particular, we find interesting ratios of susceptibilities that are sensitive to one correction and not the other. This allows us to constrain the excluded volume and particle spectrum effects separately. Analysis of the available lattice results suggests the presence of both the extra states in the baryonstrangeness sector and the repulsive baryonic interaction, with indications that hyperons have a smaller repulsive core than non-strange baryons. We note that these results are interesting for heavy-ion-collision systems at both the LHC and RHIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the Neutron Spin Asymmetry A1n in the Valence Quark Region in Hall C at Jefferson Lab

The quest to understand how the nucleon spin is decomposed into its constituent quark and gluon spin and orbital angular momentum (OAM) components has been at the forefront of nuclear physics for decades. Due to the non-perturbative nature of Quantum Chromodynamics (QCD) - the theory describing how quarks and gluons bind together to form protons and neutrons - making absolute predictions of nucleon spin structure is generally difficult, especially as a function of its quark and gluon longitudinal momentum fraction x. Measurements involving nucleon spin structure serve as a sensitive test for QCD, including ab-initio lattice QCD calculations due to the advent of the quasi-PDF formalism, and various predictions that diverge at large-x. The neutron spin asymmetry An 1 at high?x is a key observable for probing nucleon spin structure. In the valence domain (x > 0.5), sea effects are expected to be negligible, and so the total nucleon spin is considered to be carried by the valence quarks. The valence region can therefore enable us to study the role of quark OAM and other non-perturbative effects of the strong force. An 1 was measured in the deep inelastic scattering region of 0.40 < x < 0.75 and 6 < Q2 < 10 GeV2 in Hall C at Jefferson Lab using a 10.4 GeV longitudinally polarized electron beam, upgraded polarized 3He target, and the High Momentum Spectrometer (HMS) and Super High Momentum Spectrometer (SHMS). E12- 06-110 provides the first precision data in the valence quark region above x = 0.60, and its preliminary results proved consistent with earlier data disqualifying a pQCD model that excluded quark OAM. Combined with previous world proton data, the ratio of the polarized-to-unpolarized up quark momentum distribution (?u + ?u)/(u + u) remained positive at large-x, and the down quark (?d + ?d)/(d + d) remained negative.

Rehfuss, Melanie↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Model Package Report: Central Plateau Vadose Zone Models

This model package report describes concisely the modeling objectives, conceptualization, implementation, uncertainty and sensitivity, configuration control, limitations, data needs, and recommendations for improvement of the Central Plateau Vadose Zone Models. This collection of models is developed to meet the vadose zone simulation needs of the Hanford Site Composite Analysis (CA), the Hanford Site Cumulative Impact Evaluation (CIE), and are expected to find other applications in Hanford Site remedial cleanup decision-making processes. This model package report describes and documents the development of the models themselves to fulfill technical approaches defined for the CA and the CIE. This report does not document any specific calculation using these models: instead, applications of individual vadose models to perform specific calculations will be documented in environmental calculation files, including inputs and results, as appropriate. Configuration management for the Central Plateau Vadose Zone Models is managed through assignment of unique sequential numerical version numbers and archival of the models in the Environmental Modeling Management Archive.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining the Dense Matter Equation of State with New NICER Mass–Radius Measurements and New Chiral Effective Field Theory Inputs

Pulse profile modeling of X-ray data from the Neutron Star Interior Composition Explorer is now enabling precision inference of neutron star mass and radius. Combined with nuclear physics constraints from chiral effective field theory (χEFT), and masses and tidal deformabilities inferred from gravitational-wave detections of binary neutron star mergers, this has led to a steady improvement in our understanding of the dense matter equation of state (EOS). Here, we consider the impact of several new results: the radius measurement for the 1.42 M ⊙ pulsar PSR J0437−4715 presented by Choudhury et al., updates to the masses and radii of PSR J0740+6620 and PSR J0030+0451, and new χEFT results for neutron star matter up to 1.5 times nuclear saturation density. Using two different high-density EOS extensions—a piecewise-polytropic (PP) model and a model based on the speed of sound in a neutron star (CS)—we find the radius of a 1.4 M ⊙ (2.0 M ⊙ ) neutron star to be constrained to the 95% credible ranges ${12.28}_{-0.76}^{+0.50}$ km (${12.33}_{-1.34}^{+0.70}$ km) for the PP model and ${12.01}_{-0.75}^{+0.56}$ km (${11.55}_{-1.09}^{+0.94}$ km) for the CS model. The maximum neutron star mass is predicted to be ${2.15}_{-0.16}^{+0.14}$M ⊙ and ${2.08}_{-0.16}^{+0.28}$M ⊙ for the PP and CS models, respectively. We explore the sensitivity of our results to different orders and different densities up to which χEFT is used, and show how the astrophysical observations provide constraints for the pressure at intermediate densities. Moreover, we investigate the difference R 2.0 − R 1.4 of the radius of 2 M ⊙ and 1.4 M ⊙ neutron stars within our EOS inference.

gravitational wave sources↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Design for Additional Thermal/Epithermal eXperiments (TEX) with Sodium Chloride Absorbers to Provide Validation Benchmarks for TerraPower

The first set of Thermal/Epithermal eXperiments (TEX) with chlorine absorbers (TEX-Cl) were executed in Q4FY24 and are in the process of being benchmarked for the ICSBEP. TEX-Cl builds upon the TEX-HEU baseline cases that were published in the 2022 International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. TEX-HEU, like TEX-Pu, was designed to be modular to allow for the incorporation of various absorbers and reflectors to test nuclear data and application case needs. For example, TEX-HEU with hafnium (TEX-Hf) utilizes hafnium plates as both absorbers and reflectors, depending on the tested configuration. A second set of chlorine experiments, dubbed More TEX-Cl, are laid out in this report to meet the needs of TerraPower for chlorine validation for their Molten Chloride Fast Reactor (MCFR) systems. TerraPower’s Molten Chloride Reactor Experiment (MCRE) and MCFR are fast molten salt reactors that utilize sodium chloride (NaCl) salt eutectics as the fuel and coolant. The MCRE eutectic is a mixture of NaCl and uranium trichloride (UCl 3 ). An abundant need for chlorine absorption validation has been expressed by multiple members of the community, including Y-12 (whose needs were addressed with the first set of experiments), LANL (whose needs were addressed with the Chlorine Worth Study (CWS)), TerraPower, institute de radioprotection et de sûreté nucléaire (IRSN), Savannah River Nuclear Solutions (SNRS), and others. Of the members who have expressed interest in this validation, most are interested in the fast neutron energy region, where the 35 Cl(n,p) reaction is most prominent. New 35 Cl(n,p) differential cross section measurements performed by LANL at LANCSE show substantial changes to the cross sections (Figure 1) and may be validated through these experiments as some configurations are optimally sensitive to this cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organic Iodide Sorption from Dilute Gas Streams

Reprocessing used nuclear fuel releases volatile radionuclides, including 129 iodine (I), into the off-gas of a processing plant. Volatile radioiodine could be present in several forms, depending on the chemistry of the process used and the off-gas stream. Inorganic I 2 is expected to be the predominant I species in the dissolver off-gas (DOG), with minor organic iodides present. The bulk of the I is expected to volatilize into the DOG in parts-per-million-level (ppm) concentrations. In contrast, in the vessel off-gas (VOG), most of the volatile I is expected to be found as organic iodides, such as CH 3 I, C 4 H 9 I, and C 12 H 25 I. These species are expected to be present in parts-per-billion-level (ppb) concentrations but require abatement, even at low expected concentrations, to meet regulatory emissions limits in the United States. Historically, studies of I abatement by Ag-functionalized sorbents have focused on inorganic I in the DOG, but in the last few years, more research attention has been given to organic iodides, especially longer chain species, such as C 4 H 9 I, and C 12 H 25 I. This report has three main goals: (1) to present new data generated at Oak Ridge National Laboratory (ORNL) in FY21 on the sorption behavior of organic iodides on AgZ, (2) to summarize and synthesize organic iodide data produced by ORNL and Idaho National Laboratory (INL) over the last 4 years to answer questions on organic iodides behavior outlined in the 2018 joint test plan (Jubin et al. 2018), and (3) to propose a VOG abatement system design that can provide the capture efficiencies required to meet I emission limits. The 2021 ORNL experimental campaign tested the effects of organic iodide speciation and concentration in the off-gas, superficial velocity of the off-gas, and effects of aging on AgZ sorbent capacity. These studies found that the sorption rate of organic iodides by AgZ depends on the hydrocarbon chain length and the concentration in the off-gas. Higher molecular weight organic iodides adsorb to AgZ more slowly than I. At a concentration of 50 ppm concentration in the off-gas, CH 3 I loads 8% slower, C 4 H 9 I loads 20% slower, and C 12 H 25 I loads 40% slower than I. The lowest concentration loading rates calculated were in 5 ppm organic iodide gas streams in which AgZ gained on average 0.14 mg I/g sorbent/hour in the bench scale test system. Thus, longer sorbent beds might be needed to accommodate slower loading rates onto AgZ in lower concentration gas streams. Although sorption rate varies as a function of hydrocarbon chain length, the saturation concentration of the sorbent for these I-bearing species does not vary. Aging AgZ in a humid air stream for 9 months drops the overall sorbent capacity by ~35% for CH 3 I, ~50% for C 4 H 9 I, and ~40% for C 12 H 25 I. This results in a saturation capacity between 35 and 70 mg I/g sorbent for the aged AgZ. In conjunction with recent data produced by INL, these data are used to estimate the mass transfer zone (MTZ) and decontamination factor (DF) for sorbent beds of AgZ. Sorption tests performed with iodide gas concentrations of about 1 ppm and higher at a superficial gas velocity of 10 m/min, indicate that MTZ depths for these conditions tend to range between about 8-20 cm. Tests performed at lower concentrations between 50-90 ppb and at gas superficial velocities of 1, 10, and 20 m/min indicate that the MTZ depth increases with increasing superficial gas velocity. The 20 m/min test indicates that the MTZ for those conditions was at least 22 cm, and doubling the superficial gas velocity from 10 to 20 m/min could roughly double or triple the MTZ depth. Doubling and tripling the bounding MTZ depth of 20 cm for the body of MTZ estimates made at with 10 m/min superficial velocity would extend the MTZ for a superficial velocity of 20 m/min to 40-60 cm. This bounding limit applies to all of the organic iodides that have been tested. These results also indicate that the sorption rate-limiting step is not sensitive to the superficial gas velocity; otherwise the MTZ depth would not have increased approximately in proportion to the increase in the gas superficial velocity. This further suggests that the rate limiting step is not associated with mass transfer of the sorbate to the sorbent surface, or mass transfer of the reaction byproducts from the sorbent surface, but is associated with sorption or chemical reactions on the sorbent surface or in sorbent pores. Deep bed testing at INL has established DFs of >2,000 for I, CH 3 I, and C 4 H 9 I under a range of conditions (Soelberg et al. 2021, Bruffey et al. 2019). DF does not seem to be affected by the concentration of the organic iodide in the gas stream over the range of 1 to 50 ppm. Thus, if the MTZ is accommodated in sorbent bed design for the DOG and VOG, then regulatory DFs will be met. To meet the third objective outlined in this report, these experimental data were used to update an engineering evaluation of the VOG first completed in 2016. The updated VOG design can be found in an accompanying document (Welty et al., 2021; INL- LTD-21-64587). This report finds that the VOG will decrease in both size and complexity, relative to previous designs, and will still meet regulatory requirements for all iodine forms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation tools, first results and experimental status of the MURAVES experiment

The MUon RAdiography of VESuvius (MURAVES) project aims at the study of Mt. Vesuvius, an active and hazardous volcano near Naples, Italy, with the use of muons freely and abundantly produced by cosmic rays. In particular, the MURAVES experiment intends to perform muographic imaging of the internal structure of the summit of Mt. Vesuvius. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help model possible eruption dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. This paper presents preliminary results from the analysis of the first data samples acquired with trackers pointing towards Mt. Vesuvius, including the first relative measurement of the density projection of two flanks of the volcano at three different altitudes; we also present the workflow of the simulation chain of the MURAVES experiment and its ongoing developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗