Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NAVIGATION SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Extended Kalman Filter Performance on the Artemis-1 Mission

The Artemis Program is NASA’s campaign to explore the Moon and beyond. Artemis-1, the uncrewed exoLEO test flight of the Orion spacecraft, was completed in 2022. There were four navigation Extended Kalman Filters (EKFs) that are part of the Orion navigation system. The Atmospheric Extended Kalman Filter (ATMEKF) estimates the vehicle position, velocity, and attitude (referred to as the vehicle state) during the ascent and entry phases of flight. Once Orion is outside of Earths atmosphere, the Earth Orbit Extended Kalman Filter (EOEKF) and CisLunar Extended Kalman Filter (CLEKF) estimate the translational states, depending on the phase of flight, while the Attitude Extended Kalman Filter (ATTEKF) estimates the rotational state of the vehicle. The Kalman filters propagate the vehicle state forward in time using a combination of dynamics models and the output data from the Inertial Measurement Unit (IMU). The filters update the vehicle states and associated uncertainties, in the form of the covariance matrix, using pseudorange measurements from GPS (in ATMEKF/EOEKF), optical navigation measurements of the Earth or Moon (in CLEKF), and star tracker measurements (in ATTEKF). Simultaneously, the Kalman filters estimate error sources in the sensors, which are included in the state vectors as Exponentially Correlated Random Variables (ECRVs). This paper will summarize the performance of these filters during the Artemis-1 mission.

Artemis-1↗

Terminal Guidance Navigation for an Asteroid Impactor Spacecraft

Near Earth Asteroids could potentially cause a great deal of devastation if one were to impact the Earth. If such an asteroid were found, the next step would be to mitigate the threat by one of several options, the most viable of which is to deflect the asteroids trajectory such that it misses the Earth by hitting it at a very high velocity with a spacecraft. The technology to perform such a deflection has been demonstrated by the Deep Impact (DI) mission, which successfully collided with comet Tempel 1 in July 2005 using an onboard autonomous navigation system, called AutoNav, for the terminal phase of the mission. In this paper, we evaluate the ability of AutoNav to impact a wide range of scenarios that an deflection mission could encounter, varying parameters such as the approach velocity, phase angle, size of the asteroid, and the determination of spacecraft attitude. Using realistic Monte Carlo simulations, we tabulated the probability of success of the deflection as a function of these parameters, and find the highest sensitivity to be due the spacecraft attitude determination mode. We conclude with some recommendations for future work.

autonomous navigation↗

Vehicle Transponder for Preemption of Traffic Lights

The purpose of this article is to describe, in more detail, the transponder installed in each vehicle that participates in the emergency traffic-light-preemption system described in the immediately preceding article. The transponder (see figure) is a fully autonomous data--collection, data-processing, information-display, and communication subsystem that performs robustly in preemption of traffic lights and monitoring of the statuses of street intersections. This transponder monitors the condition of the emergency vehicle in which it is installed and determines when the vehicle has been placed in an emergency-response condition with its siren and/or warning lights activated. Upon detection of such a condition, the transponder collects real-time velocity and acceleration data from the onboard diagnostic (OBD) computer of the vehicle. For this purpose, the transponder contains an OBD interface circuit, including a microprocessor that determines the manufacturer and model of the vehicle and then sends the appropriate commands to the OBD computer requesting the speed and acceleration data. At the same time, data from an onboard navigation system are collected to determine the location and the heading of the vehicle. Then acceleration, speed, position, and heading data are processed and combined with a vehicle-identification number and the resulting set of data is transmitted to monitoring and control units located at all intersections within communication range. When the unit at an intersection determines that this vehicle is approaching and has priority to preempt the intersection, it transmits a signal declaring the priority and the preemption to all participating vehicles (including this one) in the vicinity. If the unit at the intersection has determined that other participating vehicles are also approaching the intersection, then this unit also transmits, to the vehicle that has priority, a message that the other vehicles are approaching the same intersection. The texts of these messages, plus graphical symbols that show the directions and numbers of the approaching vehicles, are presented on the display panel of a computer that is part of the transponder.

Foster, Conrad↗

Computer program for design and performance analysis of navigation-aid power systems. Program documentation. Volume 1: Software requirements document

A computer program has been developed for designing and analyzing the performance of solar array/battery power systems for the U.S. Coast Guard Navigational Aids. This program is called the Design Synthesis/Performance Analysis (DSPA) Computer Program. The basic function of the Design Synthesis portion of the DSPA program is to evaluate functional and economic criteria to provide specifications for viable solar array/battery power systems. The basic function of the Performance Analysis portion of the DSPA program is to simulate the operation of solar array/battery power systems under specific loads and environmental conditions. This document establishes the software requirements for the DSPA computer program, discusses the processing that occurs within the program, and defines the necessary interfaces for operation.

Goltz, G.↗

Mars Science Laboratory Interplanetary Navigation Analysis

The Mars Science Laboratory (MSL) is a NASA rover mission that will be launched in late 2011 and will land on Mars in August of 2012. This paper describes the analyses performed to validate the navigation system for launch, interplanetary cruise, and approach. MSL will use guidance during its descent into Mars in order to minimize landing dispersions, and therefore will be able to use smaller landing zones that are closer to terrain of high scientific interest. This will require a more accurate delivery of the spacecraft to the atmospheric entry interface, and a late update of the state of the spacecraft at entry. During cruise and approach the spacecraft may perform up to six trajectory correction maneuvers (TCMs), to target to the desired landing site with the required flight path angle at entry. Approach orbit determination covariance analyses have been performed to evaluate the accuracy that can be achieved in delivering the spacecraft to the entry interface point, and to determine how accurately the state of the spacecraft can be predicted to initialize the guidance algorithm. In addition, a sensitivity analysis has been performed to evaluate which factors most contribute to the improvement or degradation of the navigation performance, for both entry flight path angle delivery and entry state knowledge.

orbit determination↗

Mars Science Laboratory interplanetary navigaton analysis

The Mars Science Laboratory (MSL) is a NASA rover mission that will be launched in late 2011 and will land on Mars in August of 2012. This paper describes the analyses performed to validate the navigation system for launch, interplanetary cruise, and approach. MSL will use guidance during its descent into Mars in order to minimize landing dispersions, and therefore will be able to use smaller landing zones that are closer to terrain of high scientific interest. This will require a more accurate delivery of the spacecraft to the atmospheric entry interface, and a late update of the state of the spacecraft at entry. During cruise and approach the spacecraft may perform up to six trajectory correction maneuvers (TCMs), to target to the desired landing site with the required flight path angle at entry. Approach orbit determination covariance analyses have been performed to evaluate the accuracy that can be achieved in delivering the spacecraft to the entry interface point, and to determine how accurately the state of the spacecraft can be predicted to initialize the guidance algorithm. In addition, a sensitivity analysis has been performed to evaluate which factors most contribute to the improvement or degradation of the navigation performance, for both entry flight path angle delivery and entry state knowledge.

Wong, Mau C.↗

Entanglement-enhanced atomic gyroscope

The advent of increasingly precise gyroscopes has played a key role in the technological development of navigation systems. Ring-laser and fiber-optic gyroscopes, for example, are widely used in modern inertial guidance systems and rely on the interference of unentangled photons to measure mechanical rotation. The sensitivity of these devices scales with the number of particles used as 1/{radical}(N). Here we demonstrate how, by using sources of entangled particles, it is possible to do better and even achieve the ultimate limit allowed by quantum mechanics where the precision scales as 1/N. We propose a gyroscope scheme that uses ultracold atoms trapped in an optical ring potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tropospheric- Stratospheric Measurement Studies Summary

The two high altitude aircraft, ER-2 NASA #706 and 709 and the DC-8 NASA #717 are in active use in several programs of upper atmospheric research to study polar ozone changes, stratospheric-tropospheric exchange processes and atmospheric effects of aviation aircraft. The ER-2 has participated in seven major missions which mainly concentrated on vortex dynamics and the large losses of Ozone in the Polar regions (Ozone hole) observed in the spring. One mission verified the complex dynamical chemical and physical processes that occur during sunrise and sunset. Stratospheric Tracers of Atmospheric Transport (STRAT) obtained background measurements using the full ER-2 suite of instruments. Photochemistry of Ozone Loss in the Arctic Region in Summer (POLARIS) in 1997 assisted in understanding the mid-latitude and Arctic Ozone losses during the Northern Summer. The DC-8 with the Meteorological Measurement System (MMS) has participated in the Subsonic Aircraft: Cloud and Contrail Effects Special Study (SUCCESS), in 1996 and the Subsonic assessment Ozone and Nitrogen oxide experiment (SONEX) in 1997 missions. The MMS with its sophisticated software accurately measures ground speed and attitude, in-situ static and dynamic pressure total temperature, which are used to calculate the three dimensional wind fields, static pressure, temperature and turbulence values to meteorological accuracy. The meteorological data is not only of interest for its own sake in atmospheric dynamical processes such as mountain waves and flux measurements; but is also required by other ER-2 experiments that simultaneously measure water vapor, O3, aerosols, NO, HCl, CH4, N2O, ClO, BrO, CO2, NOy, HOx and temperature gradients. MMS products are extensively used to assist in the interpretation of their results in understanding the importance of convective effects relative to in-situ chemical changes, as may be noted by examining the list of references attached. The MMS consists of three subsystems: (a) aircraft instrumentation, inertial navigation system (INS), static and dynamic pressure taps, (b) additional dedicated instrumentation measuring angle of attack, yaw, total temperature, and a GPS which on the DC-8 measures position, velocity and attitude (c) an on board data, storage and computing acquisition system. This instrumentation and the associated software requires both an on-going laboratory ground calibration procedure for the total air temperature, static and total pressure inputs, verification of the INS dynamic response and also extensive air measurements and intercomparisons which ultimately verify and calibrate the complete system and its software. More than the usual accuracy is required because of the near cancellation occurring in the difference between the ground speed and true airspeed vectors used to give the wind vector. In the past year we have redesigned, recalibrated and used the MMS system on the NASA DC-8 that was previously used in the SUCCESS mission for the SONEX mission. Two papers were co-authored based on SUCCESS flights. Several reports and handouts were written for SONEX. Calibrations of the DC-8 pressure transducer temperature measuring thermistors was completed and an extensive analysis spanning several years of data files of the DC-8 Rosemount pressure transducer calibrations was done.

Browen, Stuart W.↗

Automated Announcements of Approaching Emergency Vehicles

Street intersections that are equipped with traffic lights would also be equipped with means for generating audible announcements of approaching emergency vehicles, according to a proposal. The means to generate the announcements would be implemented in the intersection- based subsystems of emergency traffic-light-preemption systems like those described in the two immediately preceding articles and in "Systems Would Preempt Traffic Lights for Emergency Vehicles" (NPO-30573), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 36. Preempting traffic lights is not, by itself, sufficient to warn pedestrians at affected intersections that emergency vehicles are approaching. Automated visual displays that warn of approaching emergency vehicles can be helpful as a supplement to preemption of traffic lights, but experience teaches that for a variety of reasons, pedestrians often do not see such displays. Moreover, in noisy and crowded urban settings, the lights and sirens on emergency vehicles are often not noticed until a few seconds before the vehicles arrive. According to the proposal, the traffic-light preemption subsystem at each intersection would generate an audible announcement for example, emergency vehicle approaching, please clear intersection whenever a preemption was triggered. The subsystem would estimate the time of arrival of an approaching emergency vehicle by use of vehicle identity, position, and time data from one or more sources that could include units connected to traffic loops and/or transponders connected to diagnostic and navigation systems in participating emergency vehicles. The intersection-based subsystem would then start the announcement far enough in advance to enable pedestrians to leave the roadway before any emergency vehicles arrive.

Bachelder, Aaron↗

Closed Loop Terminal Guidance Navigation for a Kinetic Impactor Spacecraft

A kinetic impactor spacecraft is a viable method to deflect an asteroid which poses a threat to the Earth. The technology to perform such a deflection has been demonstrated by the Deep Impact (DI) mission, which successfully collided with comet Tempel 1 in July 2005 using an onboard autonomous navigation system, called AutoNav, for the terminal phase of the mission. In this paper, we evaluate the ability of AutoNav to impact a wide range of scenarios that an deflection mission could encounter, varying parameters such as the approach velocity, phase angle, size of the asteroid, and the determination of spacecraft attitude. Using realistic Monte Carlo simulations, we tabulated the probability of success of the deflection as a function of these parameters, and the highest sensitivity to be due the spacecraft attitude determination mode. In addition, we also specifically analyzed the impact probability for a proposed mission which would send an impactor to the asteroid 1999RQ36. We conclude with some recommendations for future work.

closed loop guidance↗

Underwater Mapping Results for Seabotix vLBV300 Vehicle with Tritech Gemini 720i Imaging Sonar near Newport, OR

This document presents results from tests to demonstrate underwater mapping capabilities of an underwater vehicle in conditions typically found in marine renewable energy arrays. These tests were performed with a tethered Seabotix vLBV300 underwater vehicle. The vehicle is equipped with an inertial navigation system (INS) based on a Gladiator Landmark 40 IMU and Teledyne Explorer Doppler Velocity Log, as well as a Gemini 720i scanning sonar acquired from Tritech. The results presented include both indoor pool and offshore deployments. The indoor pool deployments were performed on October 7, 2016 and February 3, 2017 in Corvallis, OR. The offshore deployment was performed on April 20, 2016 off the coast of Newport, OR (44.678 degrees N, 124.109 degrees W). During the mission period, the sea state varied between 3 and 4, with an average significant wave height of 1.6 m. Data was recorded from both the INS and the sonar.

16 TIDAL AND WAVE POWER↗

An improved method for precise automatic co-registration of moderate and high-resolution spacecraft imagery

Improvements to the automated co-registration and change detection software package, AFIDS (Automatic Fusion of Image Data System) has recently completed development for and validation by NGA/GIAT. The improvements involve the integration of the AFIDS ultra-fine gridding technique for horizontal displacement compensation with the recently evolved use of Rational Polynomial Functions/ Coefficients (RPFs/RPCs) for image raster pixel position to Latitude/Longitude indexing. Mapping and orthorectification (correction for elevation effects) of satellite imagery defies exact projective solutions because the data are not obtained from a single point (like a camera), but as a continuous process from the orbital path. Standard image processing techniques can apply approximate solutions, but advances in the state-of-the-art had to be made for precision change-detection and time-series applications where relief offsets become a controlling factor. The earlier AFIDS procedure required the availability of a camera model and knowledge of the satellite platform ephemeredes. The recent design advances connect the spacecraft sensor Rational Polynomial Function, a deductively developed model, with the AFIDS ultrafine grid, an inductively developed representation of the relationship raster pixel position to latitude /longitude. As a result, RPCs can be updated by AFIDS, a situation often necessary due to the accuracy limits of spacecraft navigation systems. An example of precision change detection will be presented from Quickbird.

co-registration↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Autonomous Navigation Performance During The Hartley 2 Comet Flyby

On November 4, 2010, the EPOXI spacecraft performed a 700-km flyby of the comet Hartley 2 as follow-on to the successful 2005 Deep Impact prime mission. EPOXI, an extended mission for the Deep Impact Flyby spacecraft, returned a wealth of visual and infrared data from Hartley 2, marking the fifth time that high-resolution images of a cometary nucleus have been captured by a spacecraft. The highest resolution science return, captured at closest approach to the comet nucleus, was enabled by use of an onboard autonomous navigation system called AutoNav. AutoNav estimates the comet-relative spacecraft trajectory using optical measurements from the Medium Resolution Imager (MRI) and provides this relative position information to the Attitude Determination and Control System (ADCS) for maintaining instrument pointing on the comet. For the EPOXI mission, AutoNav was tasked to enable continuous tracking of a smaller, more active Hartley 2, as compared to Tempel 1, through the full encounter while traveling at a higher velocity. To meet the mission goal of capturing the comet in all MRI science images, position knowledge accuracies of +/- 3.5 km (3-?) cross track and +/- 0.3 seconds (3-?) time of flight were required. A flight-code-in-the-loop Monte Carlo simulation assessed AutoNav's statistical performance under the Hartley 2 flyby dynamics and determined optimal configuration. The AutoNav performance at Hartley 2 was successful, capturing the comet in all of the MRI images. The maximum residual between observed and predicted comet locations was 20 MRI pixels, primarily influenced by the center of brightness offset from the center of mass in the observations and attitude knowledge errors. This paper discusses the Monte Carlo-based analysis that led to the final AutoNav configuration and a comparison of the predicted performance with the flyby performance.

flyby↗

Best Practices for the Design, Development, and Operation of Robust and Reliable Space Vehicle Guidance, Navigation, and Control Systems

This document summarizes and updates the NESC Guidance, Navigation, and Control (GN&C) Technical Discipline Team’s (TDT) work to synthesize and document the current best practices for the design & development of robust and reliable GN&C systems for robotic and crewed (human-rated) spacecraft. These GN&C best practices for future science and exploration missions were derived from the lessons learned, both positive and negative, on earlier spaceflight projects, both robotic and crewed. An attempt has been made to capture preferred practices that reflect the key considerations, trades, and processes directly attributed to past mission success.

Guidance, Navigation, and Control↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high‐order discontinuous Galerkin approach for physics‐based thermospheric modeling

Abstract The accurate prediction of aerodynamic drag on satellites orbiting in the upper atmosphere is critical to the operational success of modern space technologies, such as satellite‐based communication or navigation systems, which have become increasingly popular in the last few years due to the deployment of constellations of satellites in low‐Earth orbit. As a result, physics‐based models of the ionosphere and thermosphere have emerged as a necessary tool for the prediction of atmospheric outputs under highly variable space weather conditions. This paper proposes a high‐fidelity approach for physics‐based space weather modeling based on the solution of the Navier–Stokes equations using a high‐order discontinuous Galerkin method, combined with a matrix‐free strategy suitable for high‐performance computing on GPU architectures. The approach consists of a thermospheric model that describes a chemically frozen neutral atmosphere in nonhydrostatic equilibrium driven by the external excitation of the Sun. A novel set of variables is considered to treat the low densities present in the upper atmosphere and to accommodate the wide range of scales present in the problem. At the same time, and unlike most existing approaches, radial and angular directions are treated in a nonsegregated approach. The study presents a set of numerical examples that demonstrate the accuracy of the approximation and validate the current approach against observational data along a satellite orbit, including estimates of established empirical and physics‐based models of the ionosphere‐thermosphere system. Finally, a one‐dimensional radial derivation of the physics‐based model is presented and utilized for conducting a parametric study of the main thermal quantities under various solar conditions.

Engineering↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗