Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Construction of EMSC-islet co-localizing composites for xenogeneic porcine islet transplantation

Highlights: • Endothelial-like mesenchymal stem cells (EMSC) are differentiated from MSCs. • EMSC-islet co-localizing composites may be an effective islet delivery modality. • EMSC-islet composites reduce the fragmentation of porcine islets. • EMSC-islet composites enhance the vascularization potential in vitro and in vivo. Pancreatic islet transplantation is an ultimate solution for treating patients with type 1 diabetes (T1D). The pig is an ideal donor of islets for replacing scarce human islets. Besides immunological hurdles, non-immunological hurdles including fragmentation and delayed engraftment of porcine islets need solutions to succeed in porcine islet xenotransplantation. In this study, we suggest a simple but effective modality, a cell/islet co-localizing composite, to overcome these challenges. Endothelial-like mesenchymal stem cells (EMSCs), differentiated from bone-marrow derived mouse mesenchymal stem cells (MSCs), and MSCs evenly coated the surface of porcine islets (>85%) through optimized culture conditions. Both MSCs and EMSCs significantly reduced the fragmentation of porcine islets and increased the islet masses, designated as islet equivalents (IEQs). In fibrin in vitro and in vivo angiogenesis analysis, constructed EMSC-islet composites showed higher angiogenic potentials than naked islets, MSC-islet composites, or human endothelial cell-islet composites. This novel delivery method of porcine islets may have beneficial effects on the engraftment of transplanted islets by prevention of fragmentation and enhancement of revascularization.

60 APPLIED LIFE SCIENCES↗

Implementation of Remote 3-Dimensional Image Guided Radiation Therapy Quality Assurance for Radiation Therapy Oncology Group Clinical Trials

Purpose: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. Methods and Materials: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities. Results: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases. Conclusion: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Dose Consolidation Radiation Therapy for Early Stage Unfavorable Hodgkin Lymphoma

Purpose: The German Hodgkin Study Group (GHSG) trial HD11 established 4 cycles of doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) and 30 Gy of radiation therapy (RT) as a standard for early stage (I, II), unfavorable Hodgkin lymphoma (HL). Additional cycles of ABVD may allow for a reduction in RT dose and improved toxicity profile. Methods and Materials: Patients treated with combined modality therapy at the Duke Cancer Institute for early stage, unfavorable HL by GHSG criteria from 1994 to 2012 were included. Patients who did not undergo post-chemotherapy functional imaging (positron emission tomography or gallium imaging) or who failed to achieve a complete response were excluded. Clinical outcomes were estimated using the Kaplan-Meier method. Late effects were also evaluated. Results: A total of 90 patients met inclusion criteria for analysis. Median follow-up was 5 years. Chemotherapy consisted primarily of ABVD (88%) with a median number of 6 cycles. The median dose of consolidation RT was 23.4 Gy. Four patients had relapses, 2 of which were in-field. Ten-year progression-free survival (PFS) and overall survival (OS) were 93% (95% confidence interval [CI]: 0.82-0.97) and 98% (95% CI: 0.92-0.99), respectively. For the subset of patients (n=46) who received 5 to 6 cycles of chemotherapy and ≤24 Gy, the 10-year PFS and OS values were 88% (95% CI: 70%-96%) and 98% (95% CI: 85% - 99%), respectively. The most common late effect was hypothyroidism (20%) with no cardiac complications. Seven secondary malignancies were diagnosed, with only 1 arising within the RT field. Conclusions: Lower doses of RT may be sufficient when combined with more than 4 cycles of ABVD for early stage, unfavorable HL and may result in a more favorable toxicity profile than 4 cycles of ABVD and 30 Gy of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

Radiotherapy Technical Considerations in the Management of Locally Advanced Pancreatic Cancer: American-French Consensus Recommendations

Summary: Pancreatic carcinoma is a leading cause of cancer-related mortality. Approximately 30% of pancreatic cancer patients present with locally advanced, unresectable nonmetastatic disease. For these patients, two therapeutic options exist: systemic chemotherapy or chemoradiotherapy. Within this context, the optimal technique for pancreatic irradiation is not clearly defined. A search to identify relevant studies was undertaken using the Medline database. All Phase III randomized trials evaluating the modalities of radiotherapy in locally advanced pancreatic cancer were included, as were some noncontrolled Phase II and retrospective studies. An expert panel convened with members of the Radiation Therapy Oncology Group and GERCOR cooperative groups to review identified studies and prepare the guidelines. Each member of the working group independently evaluated five endpoints: total dose, target volume definition, radiotherapy planning technique, dose constraints to organs at risk, and quality assurance. Based on this analysis of the literature, we recommend either three-dimensional conformal radiation therapy or intensity-modulated radiation therapy to a total dose of 50 to 54 Gy at 1.8 to 2 Gy per fraction. We propose gross tumor volume identification to be followed by an expansion of 1.5 to 2 cm anteriorly, posteriorly, and laterally, and 2 to 3 cm craniocaudally to generate the planning target volume. The craniocaudal margins can be reduced with the use of respiratory gating. Organs at risk are liver, kidneys, spinal cord, stomach, and small bowel. Stereotactic body radiation therapy should not be used for pancreatic cancer outside of clinical trials. Radiotherapy quality assurance is mandatory in clinical trials. These consensus recommendations are proposed for use in the development of future trials testing new chemotherapy combinations with radiotherapy. Not all of these recommendations will be appropriate for trials testing radiotherapy dose or dose intensity concepts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction ultrafast sintering

This study proposes and demonstrates induction ultrafast sintering (IUS), which enables rapid densification of refractory and other materials via two contactless modalities: direct IUS (d-IUS), where heating occurs through electromagnetic coupling with the sample, and susceptor IUS (s-IUS), where heating is achieved indirectly via an induction-heated metal case. Ultrahigh heating rates of ∼75 to >450 °C/s and temperatures exceeding 2500 °C are readily achieved. Both d-IUS and s-IUS densify molybdenum to high densities within 120 s, with only ∼1–3 % porosity observed by image analysis. Similarly, 3 mol % yttria-stabilized zirconia (3YSZ) reaches ∼97 % relative density in 30 s via s-IUS. This study further demonstrates ultrafast reactive sintering of two difficult-to-sinter materials: a refractory compositionally complex alloy–carbide (RCCA–CCC) composite, NbMoTaW–(Nb 0.37 Mo 0.11 Ta 0.39 W 0.13 ) 2 C, using d-IUS, and a compositionally complex silicide (CCS), (Mo 1/3 Nb 1/3 Zr 1/3 )Si 2 , using s-IUS. This IUS platform offers a versatile route for high-throughput materials discovery and energy-efficient fabrication of bulk refractory materials.

36 MATERIALS SCIENCE↗

Enhancing hyperspectral EELS analysis of complex plasmonic nanostructures with pan-sharpening

Nanoscale hyperspectral techniques—such as electron energy loss spectroscopy (EELS)—are critical to understand the optical response in plasmonic nanostructures, but as systems become increasingly complex, the required sampling density and acquisition times become prohibitive for instrumental and specimen stability. As a result, there has been a recent push for new experimental methodologies that can provide comprehensive information about a complex system, while significantly reducing the duration of the experiment. In this work, we present a pan-sharpening approach to hyperspectral EELS analysis, where we acquire two datasets from the same region (one with high spatial resolution and one with high spectral fidelity) and combine them to achieve a single dataset with the beneficial properties of both. This work outlines a straightforward, reproducible pathway to reduced experiment times and higher signal-to-noise ratios, while retaining the relevant physical parameters of the plasmonic response, and is generally applicable to a wide range of spectroscopy modalities.

36 MATERIALS SCIENCE↗

Stilbene Boronic Acids Form a Covalent Bond with Human Transthyretin and Inhibit Its Aggregation

Transthyretin (TTR) is a homotetrameric protein. Its dissociation into monomers leads to the formation of fibrils that underlie human amyloidogenic diseases. The binding of small molecules to the thyroxin-binding sites in TTR stabilizes the homotetramer and attenuates TTR amyloidosis. Herein, we report on boronic acid-substituted stilbenes that limit TTR amyloidosis in vitro. Assays of affinity for TTR and inhibition of its tendency to form fibrils were coupled with X-ray crystallographic analysis of nine TTR·ligand complexes. The ensuing structure–function data led to a symmetrical diboronic acid that forms a boronic ester reversibly with serine 117. This diboronic acid inhibits fibril formation by both wild-type TTR and a common disease-related variant, V30M TTR, as effectively as does tafamidis, a small-molecule drug used to treat TTR-related amyloidosis in the clinic. We conclude these findings establish a new modality for covalent inhibition of fibril formation and illuminate a path for future optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method of surface marker location optimization for tumor motion estimation in lung stereotactic body radiation therapy

Purpose: Accurately localizing lung tumor localization is essential for high-precision radiation therapy techniques such as stereotactic body radiation therapy (SBRT). Since direct monitoring of tumor motion is not always achievable due to the limitation of imaging modalities for treatment guidance, placement of fiducial markers on the patient’s body surface to act as a surrogate for tumor position prediction is a practical alternative for tracking lung tumor motion during SBRT treatments. In this work, the authors propose an innovative and robust model to solve the multimarker position optimization problem. The model is able to overcome the major drawbacks of the sparse optimization approach (SOA) model. Methods: The principle-component-analysis (PCA) method was employed as the framework to build the authors’ statistical prediction model. The method can be divided into two stages. The first stage is to build the surrogate tumor matrix and calculate its eigenvalues and associated eigenvectors. The second stage is to determine the “best represented” columns of the eigenvector matrix obtained from stage one and subsequently acquire the optimal marker positions as well as numbers. Using 4-dimensional CT (4DCT) and breath hold CT imaging data, the PCA method was compared to the SOA method with respect to calculation time, average prediction accuracy, prediction stability, noise resistance, marker position consistency, and marker distribution. Results: The PCA and SOA methods which were both tested were on all 11 patients for a total of 130 cases including 4DCT and breath-hold CT scenarios. The maximum calculation time for the PCA method was less than 1 s with 64 752 surface points, whereas the average calculation time for the SOA method was over 12 min with 400 surface points. Overall, the tumor center position prediction errors were comparable between the two methods, and all were less than 1.5 mm. However, for the extreme scenarios (breath hold), the prediction errors for the PCA method were not only smaller, but were also more stable than for the SOA method. Results obtained by imposing a series of random noises to the surrogates indicated that the PCA method was much more noise resistant than the SOA method. The marker position consistency tests using various combinations of 4DCT phases to construct the surrogates suggested that the marker position predictions of the PCA method were more consistent than those of the SOA method, in spite of surrogate construction. Marker distribution tests indicated that greater than 80% of the calculated marker positions fell into the high cross correlation and high motion magnitude regions for both of the algorithms. Conclusions: The PCA model is an accurate, efficient, robust, and practical model for solving the multimarker position optimization problem to predict lung tumor motion during SBRT treatments. Due to its generality, PCA model can also be applied to other imaging guidance system whichever using surface motion as the surrogates.

60 APPLIED LIFE SCIENCES↗

Transient dynamics, damping, and mode coupling of nonlinear systems with internal resonances

The study of both linear and nonlinear structural vibrations routinely circles the concise yet complex problem of choosing a set of coordinates which yield simple equations of motion. In both experimental and mathematical methods, that choice is a difficult one because of measurement, computational, and interpretation difficulties. Often times, researchers choose to solve their problems in terms of linear, undamped mode shapes because they are easy to obtain; however, this is known to give rise to complicated phenomena such as mode coupling and internal resonance. This work considers the nature of mode coupling and internal resonance in systems containing non-proportional damping, linear detuning, and cubic nonlinearities through the method of multiple scales as well as instantaneous measures of effective damping. The energy decay observed in the structural modes is well approximated by the slow-flow equations in terms of the modal amplitudes, and it is shown how mode coupling enhances the damping observed in the system. Moreover, in the presence of a 3:1 internal resonance between two modes, the nonlinearities not only enhance the dissipation, but can allow for the exchange and transfer of energy between the resonant modes. However, this exchange depends on the resonant phase between the modes and is proportional to the energy in the lowest mode. The results of the analysis tie together interpretations used by both experimentalists and theoreticians to study such systems and provide a more concrete way to interpret these phenomena.

42 ENGINEERING↗

A mathematical model platform for optimizing a multiprojection breast imaging system

Multiprojection imaging is a technique in which a plurality of digital radiographic images of the same patient are acquired within a short interval of time from slightly different angles. Information from each image is combined to determine the final diagnosis. Projection data are either reconstructed into slices as in the case of tomosynthesis or analyzed directly as in the case of multiprojection correlation imaging technique, thereby avoiding reconstruction artifacts. In this study, the authors investigated the optimum geometry of acquisitions of a multiprojection breast correlation imaging system in terms of the number of projections and their total angular span that yield maximum performance in a task that models clinical decision. Twenty-five angular projections of each breast from 82 human subjects in our breast tomosynthesis database were each supplemented with a simulated 3 mm mass. An approach based on Laguerre-Gauss channelized Hotelling observer was developed to assess the detectability of the mass in terms of receiver operating characteristic (ROC) curves. Two methodologies were developed to integrate results from individual projections into one combined ROC curve as the overall figure of merit. To optimize the acquisition geometry, different components of acquisitions were changed to investigate which one of the many possible configurations maximized the area under the combined ROC curve. Optimization was investigated under two acquisition dose conditions corresponding to a fixed total dose delivered to the patient and a variable dose condition, based on the number of projections used. In either case, the detectability was dependent on the number of projections used, the total angular span of those projections, and the acquisition dose level. In the first case, the detectability approximately followed a bell curve as a function of the number of projections with the maximum between 8 and 16 projections spanning angular arcs of about 23 deg. - 45 deg., respectively. In the second case, the detectability increased with the number of projections approaching an asymptote at 11-17 projections for an angular span of about 45 deg. These results indicate the inherent information content of the multiprojection image data reflecting the relative role of quantum and anatomical noise in multiprojection breast imaging. The optimization scheme presented here may be applied to any multiprojection imaging modalities and may be extended by including reconstruction in the case of digital breast tomosynthesis and breast computed tomography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancing Complex System Performance Using Discrete-Event Simulation

In this paper, we utilize discrete-event simulation (DES) merged with human factors analysis to provide the venue within which the separation and deconfliction of the system/human operating principles can occur. A concrete example is presented to illustrate the performance enhancement gains for an aviation cargo flow and security inspection system achieved through the development and use of a process DES. The overall performance of the system is computed, analyzed, and optimized for the different system dynamics. Various performance measures are considered such as system capacity, residual capacity, and total number of pallets waiting for inspection in the queue. These metrics are performance indicators of the system's ability to service current needs and respond to additional requests. We studied and analyzed different scenarios by changing various model parameters such as the number of pieces per pallet ratio, number of inspectors and cargo handling personnel, number of forklifts, number and types of detection systems, inspection modality distribution, alarm rate, and cargo closeout time. The increased physical understanding resulting from execution of the queuing model utilizing these vetted performance measures identified effective ways to meet inspection requirements while maintaining or reducing overall operational cost and eliminating any shipping delays associated with any proposed changes in inspection requirements. With this understanding effective operational strategies can be developed to optimally use personnel while still maintaining plant efficiency, reducing process interruptions, and holding or reducing costs.

42 ENGINEERING↗

Derivation of a triple mosaic adenovirus based on modification of the minor capsid protein IX

Adenoviral capsid protein IX (pIX) has been shown to be a potential locale to insert targeting, imaging-related and therapeutic modalities by genetic modification. Recent evidences suggested that capsid protein mosaicism could be a promising strategy for improving the utility of Ad vector. In this study, we explored a method to genetically generate triple pIX mosaic Ad serotype 5 (Ad5) displaying three types of pIX on a single virion. pIXs were modified at their carboxy termini with a Flag sequence, a hexahistidine sequence (His{sub 6}) or a monomeric red fluorescent protein (mRFP1), respectively. Western blotting analysis and fluorescence microscopy of the purified recombinant viruses indicated that all three modified pIXs were incorporated into the viral particles. Immuno-gold electron microscopy (EM) further confirmed that three types of pIX indeed co-existed on an individual virion. These results firstly validated a triple mosaic capsid configuration on pIX, and demonstrated the possibility of further radical design.

60 APPLIED LIFE SCIENCES↗

Identification of Blue Horizontal Branch Stars with Multimodal Fusion

Blue Horizontal Branch stars (BHBs) are ideal tracers to probe the global structure of the milky Way (MW), and the increased size of the BHB star sample could be helpful to accurately calculate the MW's enclosed mass and kinematics. Large survey telescopes have produced an increasing number of astronomical images and spectra. However, traditional methods of identifying BHBs are limited in dealing with the large scale of astronomical data. A fast and efficient way of identifying BHBs can provide a more significant sample for further analysis and research. Therefore, in order to fully use the various data observed and further improve the identification accuracy of BHBs, we have innovatively proposed and implemented a Bi-level attention mechanism-based Transformer multimodal fusion model, called Bi-level Attention in the Transformer with Multimodality (BATMM). The model consists of a spectrum encoder, an image encoder, and a Transformer multimodal fusion module. The Transformer enables the effective fusion of data from two modalities, namely image and spectrum, by using the proposed Bi-level attention mechanism, including cross-attention and self-attention. As a result, the information from the different modalities complements each other, thus improving the accuracy of the identification of BHBs. The experimental results show that the F1 score of the proposed BATMM is 94.78%, which is 21.77% and 2.76% higher than the image and spectral unimodality, respectively. It is therefore demonstrated that higher identification accuracy of BHBs can be achieved by means of using data from multiple modalities and employing an efficient data fusion strategy.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-285: Revisiting the Nomogram for Intra-Operative Planning Based Pd-103 Brachytherapy

Purpose: The seed implant technique at our institution involves using a published nomogram for seed ordering based on CT based volume studies of the prostate. Ultrasound volume studies are subsequently used in the operating room for planning a modified peripheral loading with urethra sparing seed implant. The purpose of this study is to determine the appropriate modality for prostate volume measurement and creating an updated nomogram for intra-operative planning specific to our technique for pd-103 brachytherapy for efficient seed ordering. Methods: Prostate volumes based on pre-implant CT (Pre-CT), intra-operative ultrasound (TRUS), and post-implant CT (post-CT) studies as well as the total airkerma strength (AKS) of the implants were analyzed for 135 seed implant cases (69 monotherapy, 66 boost). Regression analysis was performed to derive the relationship between the total AKS and pre-CT and TRUS volumes. The correlation between TRUS and pre-CT volumes and TRUS and post-CT volumes were also studied. Results: Ultrasound based prostate volume exhibited a stronger correlation with total AKS than the pre-implant CT volume (R{sup 2} = 0.97 vs 0.88 for monotherapy and 0.96 vs 0.89 for boost). In general the pre-CT overestimated the prostate volume leading to ordering of a larger number of seeds and thus leading to higher number of unused/wasted seeds. Newly derived TRUS based nomogram was better suited for our technique than the published data. The post-implant CT volume closely followed the ultrasound volume (R{sup 2} = 0.88) as compared to pre-implant CT volumes (R{sup 2} = 0.57). Conclusion: In an era of costconscious health care where waste reduction is of utmost importance, an updated technique-specific nomogram is useful for ordering optimal number of seeds resulting in significant cost savings. In addition, our study shows that ultrasound based prostate volume is a better predictor for seed ordering for intra-operative planning than pre-implant CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck

Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1–2 mm and with 10–50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named “MIDA”. The model was obtained by integrating three different magnetic resonance imaging (MRI) modalities, the parameters of which were tailored to enhance the signals of specific tissues: i) structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii) magnetic resonance angiography (MRA) data to image the vasculature, and iii) diffusion tensor imaging (DTI) to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.

59 BASIC BIOLOGICAL SCIENCES↗

Glancing Angle Deposition in Gas Sensing: Bridging Morphological Innovations and Sensor Performances

Glancing Angle Deposition (GLAD) has emerged as a versatile and powerful nanofabrication technique for developing next-generation gas sensors by enabling precise control over nanostructure geometry, porosity, and material composition. Through dynamic substrate tilting and rotation, GLAD facilitates the fabrication of highly porous, anisotropic nanostructures, such as aligned, tilted, zigzag, helical, and multilayered nanorods, with tunable surface area and diffusion pathways optimized for gas detection. This review provides a comprehensive synthesis of recent advances in GLAD-based gas sensor design, focusing on how structural engineering and material integration converge to enhance sensor performance. Key materials strategies include the construction of heterojunctions and core–shell architectures, controlled doping, and nanoparticle decoration using noble metals or metal oxides to amplify charge transfer, catalytic activity, and redox responsiveness. GLAD-fabricated nanostructures have been effectively deployed across multiple gas sensing modalities, including resistive, capacitive, piezoelectric, and optical platforms, where their high aspect ratios, tailored porosity, and defect-rich surfaces facilitate enhanced gas adsorption kinetics and efficient signal transduction. These devices exhibit high sensitivity and selectivity toward a range of analytes, including NO2, CO, H2S, and volatile organic compounds (VOCs), with detection limits often reaching the parts-per-billion level. Emerging innovations, such as photo-assisted sensing and integration with artificial intelligence for data analysis and pattern recognition, further extend the capabilities of GLAD-based systems for multifunctional, real-time, and adaptive sensing. Finally, current challenges and future research directions are discussed, emphasizing the promise of GLAD as a scalable platform for next-generation gas sensing technologies.

Chemistry↗

Orbital angular momentum analysis of high-dimensional entanglement

We describe a simple experiment that is ideally suited to analyze the high-dimensional entanglement contained in the orbital angular momenta (OAM) of entangled photon pairs. For this purpose we use a two-photon interferometer with a built-in image rotator and measure the two-photon visibility versus rotation angle. Mode selection with apertures allows one to tune the dimensionality of the entanglement; mode selection with spiral phase plates and fibers allows detection of a single OAM mode. The experiment is analyzed in two different ways: either via the continuous two-photon amplitude function or via a discrete modal (Schmidt) decomposition of this function. The latter approach proves to be very fruitful, as it provides a complete characterization of the OAM entanglement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗