Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

F-18 Labeled Diabody-Luciferase Fusion Proteins for Optical-ImmunoPET

The goal of the proposed work is to develop novel dual-labeled molecular imaging probes for multimodality imaging. Based on small, engineered antibodies called diabodies, these probes will be radioactively tagged with Fluorine-18 for PET imaging, and fused to luciferases for optical (bioluminescence) detection. Performance will be evaluated and validated using a prototype integrated optical-PET imaging system, OPET. Multimodality probes for optical-PET imaging will be based on diabodies that are dually labeled with 18F for PET detection and fused to luciferases for optical imaging. 1) Two sets of fusion proteins will be built, targeting the cell surface markers CEA or HER2. Coelenterazine-based luciferases and variant forms will be evaluated in combination with native substrate and analogs, in order to obtain two distinct probes recognizing different targets with different spectral signatures. 2) Diabody-luciferase fusion proteins will be labeled with 18F using amine reactive [18F]-SFB produced using a novel microwave-assisted, one-pot method. 3) Sitespecific, chemoselective radiolabeling methods will be devised, to reduce the chance that radiolabeling will inactivate either the target-binding properties or the bioluminescence properties of the diabody-luciferase fusion proteins. 4) Combined optical and PET imaging of these dual modality probes will be evaluated and validated in vitro and in vivo using a prototype integrated optical-PET imaging system, OPET. Each imaging modality has its strengths and weaknesses. Development and use of dual modality probes allows optical imaging to benefit from the localization and quantitation offered by the PET mode, and enhances the PET imaging by enabling simultaneous detection of more than one probe.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). The mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

Preoperative imaging for locoregional staging of bladder cancer

Bladder cancer is the ninth most common cancer, expected to lead to an estimated 17,670 deaths in the United States in 2019. Clinical management and prognosis of bladder cancer mainly depend on the extent of locoregional disease, particularly whether bladder muscle is involved. Therefore, bladder cancer is often divided into superficial, non-muscle-invasive bladder cancer and muscle-invasive bladder cancer; the latter often prompts consideration for cystectomy. While precise staging prior to cystectomy is crucial, the optimal preoperative imaging modality used to stage the disease remains controversial. Transurethral resection of bladder tumor (TURBT) followed by computed tomography (CT) urography is the current recommended approach for staging bladder cancer but suffers from a high rate of understaging. We review the recent literature and compare different imaging modalities for assessing the presence of muscle invasion and lymph node involvement prior to cystectomy and highlight the advantages of each modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective Analysis of Clinical Performance of an Estonian Speech Recognition System for Radiology: Effects of Different Acoustic and Language Models

The aim of this study was to analyze retrospectively the influence of different acoustic and language models in order to determine the most important effects to the clinical performance of an Estonian language-based non-commercial radiology-oriented automatic speech recognition (ASR) system. An ASR system was developed for Estonian language in radiology domain by utilizing open-source software components (Kaldi toolkit, Thrax). The ASR system was trained with the real radiology text reports and dictations collected during development phases. The final version of the ASR system was tested by 11 radiologists who dictated 219 reports in total, in spontaneous manner in a real clinical environment. The audio files collected in the final phase were used to measure the performance of different versions of the ASR system retrospectively. ASR system versions were evaluated by word error rate (WER) for each speaker and modality and by WER difference for the first and the last version of the ASR system. Total average WER for the final version throughout all material was improved from 18.4% of the first version (v1) to 5.8% of the last (v8) version which corresponds to relative improvement of 68.5%. WER improvement was strongly related to modality and radiologist. In summary, the performance of the final ASR system version was close to optimal, delivering similar results to all modalities and being independent on user, the complexity of the radiology reports, user experience, and speech characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada↗

Multimodal vibration damping using energy transfer

The vibration control using the piezoelectric elements is an area interesting for many industrial sectors. Within this framework, we propose an improved control technique based in synchronized switch damping by energy transfer. It realizes the energy transfer using storage capacitances and switches synchronized with the structure modal coordinates or piezo-voltages. These switches produce either a voltage inversion on the piezoelements for damping or energy extraction purposes, or oscillating discharges between the piezoelements and the storage capacitances for energy transfer. This new method has an improvement in the modal damping technology SSDI-Max. Their performance is simulated with a model representative of a clamped plate with four piezoelectric elements coupled with the structural modes while taking into account realistic transfer losses. The damping effect is simulated in multi-modal with pulse or multi-sine excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement

Purpose of Review: Multimodality imaging is integral for diagnosis, procedural guidance, and follow-up of patients undergoing transcatheter aortic valve replacement (TAVR). In this review, we provide an overview of the role of each imaging modality and highlight technical considerations and pitfalls. We also address current controversies and new developments in the field. Recent Findings: Echocardiography remains the primary imaging modality for diagnosis of aortic stenosis and intraprocedural guidance for TAVR, but computed tomography (CT) imaging has supplanted echocardiography for annular sizing and access site evaluation. Magnetic resonance imaging (MRI) shows promise in targeted patient populations. Refined parameters and guidelines for valve sizing and paravalvular regurgitation have sought to standardize these complex assessments. Summary: Multimodality imaging remains critical to the success of TAVR, but its role has evolved over time. Understanding the applications, strengths, and limitations of each imaging modality is a crucial skill for the modern structural imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Imaging Techniques in Skull Base Osteomyelitis Due to Malignant Otitis Externa

Purpose of Review: To give an up-to-date overview of the strengths and weaknesses of current imaging modalities in diagnosis and follow-up of skull base osteomyelitis (SBO). Recent Findings: CT and MRI are both used for anatomical imaging, and nuclear techniques aid in functional process imaging. Hybrid techniques PET-CT and PET-MRI are the newest modalities which combine imaging strengths. Summary: No single modality is able to address the scope of SBO. A combination of functional and anatomical imaging is needed, in the case of newly suspected SBO we suggest the use of PET-MRI (T1, T2, T1-FS-GADO, DWI) and separate HRCT for diagnosis and follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the polarization of non-Gaussian optical quantum field: Higher-order optical-polarization

Polarization of light signifies transversal, anisotropic and asymmetrical statistical properties of electromagnetic radiation about the direction of propagation. Traditionally, optical-polarization is characterized by Stokes’ theory susceptible to be insufficient in assessing the polarization structure of optical quantum fields and, also, does not decipher the twin characteristic polarization parameters (‘ratio of real amplitudes and difference in phases’). An alternative way, in the spirit of classical description of optical-polarization, is introduced which can be generalized to deal higher-order polarization of quantum light, particularly, prepared in non-Gaussian Schrodinger Cat or Cat-like states and entangled bi-modal coherent states. On account of pseudo mono-modal or multi-modal nature of such optical quantum field, higher-order polarization is seen to be highly sensitive to the basis of description. -- Highlights: •We have generalized the usual concept of optical-polarization. •A concept of higher-order optical-polarization is introduced. •This concept is applied to compute the polarization-parameters of non-Gaussian Optical field. •To the best of our knowledge, no study is performed which investigates such optical quantum field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Analysis of Direct-injection spark-ignition (DISI) soot morphology

We have characterized particle emissions produced by a 4-cylinder, 2.0 L DISI engine using transmission electron microscopy (TEM) and image analysis. Analyses of soot morphology provide insight to particle formation mechanisms and strategies for prevention. Particle emissions generated by two fueling strategies were investigated, early injection and injection modified for low particle number concentration emissions. A blend of 20% ethanol and 80% emissions certification gasoline was used for the study given the likelihood of increased ethanol content in widely available fuel. In total, about 200 particles and 3000 primary soot spherules were individually measured. For the fuel injection strategy which produced low particle number concentration emissions, we found a prevalence of single solid sub-25 nm particles and fractal-like aggregates. The modal diameter of single solid particles and aggregate primary particles was between 10 and 15 nm. Solid particles as small as 6 nm were present. Although nanoparticle aggregates had fractal-like morphology similar to diesel soot, the average primary particle diameter per aggregate had a much wider range that spanned from 7 to 60 nm. For the early fuel injection strategy, liquid droplets were prevalent, and the modal average primary particle diameter was between 20 and 25 nm. The presence of liquid droplets may have been the result of unburned fuel and/or lubricating oil originating from fuel impingement on the piston or cylinder wall; the larger modal aggregate primary particle diameter suggests greater fuel-rich zones in-cylinder than for the low particle number concentration point. However, both conditions produced aggregates with a wide range of primary particle diameters, which indicates heterogeneous fuel and air mixing.

02 PETROLEUM↗

Multimodal sensor fusion framework for residential building occupancy detection

For several years now, smart building energy systems have been a research area of intensive activity. In light of the increasing need for sustainable buildings and energy systems, this trend motivates an increasing need for a solution to reduce carbon dioxide emissions and improve energy efficiency. This work proposes a high-performing and transferable occupancy detection framework that combines sensor data from different data modalities, including time series environmental data (temperature, humidity, and illuminance), image data, and acoustic energy data using ensemble method. To draw out the best prediction performance in each modality, the proposed framework was developed, including various models that were designed to learn the occupancy patterns reflected in the physical data streams. To tackle the time series environmental data, we designed two variants of an occupancy detection spatiotemporal pattern network (Occ-STPN) that performs both feature level and decision level fusion, respectively. We also propose a new metric; the fading memory mean square error (FMMSE), that provides a fair evaluation and penalization of delayed occupancy predictions. Multiple open-sourced datasets, including the Electricity Consumption and Occupancy and the University of California, Irvine's (UCI) building occupancy detection dataset, along with our own real data collected from six different houses, were used to validate the algorithms' performance. The experimental results presented herein break down the performance for each sensing modality, and a detailed analysis of the performance is also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Involved-Node and Involved-Field Volumetric Modulated Arc vs. Fixed Beam Intensity-Modulated Radiotherapy for Female Patients With Early-Stage Supra-Diaphragmatic Hodgkin Lymphoma: A Comparative Planning Study

Purpose: A comparative treatment planning study was performed to compare volumetric-modulated arc (RA) to conventional intensity modulated (IMRT) for involved-field (IFRT) and involved-node (INRT) radiotherapy for Hodgkin lymphoma (HL). Methods and Materials: Plans for 10 early-stage HL female patients were computed for RA and IMRT. First, the planning target volume (PTV) coverage and organs at risk (OAR) dose deposition was assessed between the two modalities. Second, the OAR (lung, breast, heart, thyroid, and submandibular gland) dose-volume histograms were computed and compared for IFRT and INRT, respectively. Results: For IFRT and INRT, PTV coverage was equally homogeneous with both RA and IMRT. By and large, the OAR irradiation with IFRT planning was not significantly different between RA and IMRT. For INRT, doses computed for RA were, however, usually lower than those with IMRT, particularly so for the lung, breast, and thyroid. Regardless of RA and IMRT modalities, a significant 20-50% decrease of the OAR computed mean doses was observed with INRT when compared with IFRT (Breast D{sub Mean} 1.5 +- 1.1 vs. 2.6 +- 1.7 Gy, p < 0.01 and 1.6 +- 1.1 vs. 2.9 +- 1.9 Gy, p < 0.01 for RA and IMRT, respectively). Conclusions: RA and IMRT results in similar level of dose homogeneity. With INRT but not IFRT planning, the computed doses to the PTV and OAR were usually higher and lower with RA when compared to IMRT. Regardless of the treatment modality, INRT when compared with IFRT planning led to a significant decrease in OAR doses, particularly so for the breast and heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes in Women Treated With MammoSite Brachytherapy or Whole Breast Irradiation Stratified by ASTRO Accelerated Partial Breast Irradiation Consensus Statement Groups

Purpose: The American Society for Radiation Oncology published a Consensus Statement for accelerated partial breast irradiation identifying three groups: Suitable, Cautionary, and Unsuitable. The objective of this study was to compare oncologic outcomes in women treated with MammoSite brachytherapy (MB) vs. whole breast irradiation (WBI) after stratification into Statement groups. Methods: Eligible women had invasive carcinoma or ductal carcinoma in situ (DCIS) {<=}3 cm, and {<=}3 lymph nodes positive. Women were stratified by radiation modality and Statement groups. Survival analysis methods including Kaplan-Meier estimation, Cox regression, and competing risks analysis were used to assess overall survival (OS), disease-free survival (DFS), time to local failure (TTLF), and tumor bed failure (TBF). Results: A total of 459 (183 MB and 276 WBI) patients were treated from 2002 to 2009. After a median follow-up of 45 months, we found no statistical differences by stratification group or radiation modality with regard to OS and DFS. At 4 years TTLF or TBF were not statistically different between the cohorts. Univariate analysis in the MB cohort revealed that nodal positivity (pN1 vs. pN0) was related to TTLF (hazard ratio 6.39, p = 0.02). There was a suggestion that DCIS histology had an increased risk of failure when compared with invasive ductal carcinoma (hazard ratio 3.57, p = 0.06). Conclusions: MB and WBI patients stratified by Statement groups seem to combine women who will have similar outcomes regardless of radiation modality. Although outcomes were similar, we remain guarded in overinterpretation of these preliminary results until further analysis and long-term follow-up data become available. Caution should be used in treating women with DCIS or pN1 disease with MB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Mucosa-Associated Lymphoid Tissue Lymphoma of the Salivary Glands: A Multicenter Rare Cancer Network Study

Purpose: Involvement of salivary glands with mucosa-associated lymphoid tissue (MALT) lymphoma is rare. This retrospective study was performed to assess the clinical profile, treatment outcome, and prognostic factors of MALT lymphoma of the salivary glands. Methods and Materials: Thirteen member centers of the Rare Cancer Network from 10 countries participated, providing data on 63 patients. The median age was 58 years; 47 patients were female and 16 were male. The parotid glands were involved in 49 cases, submandibular in 15, and minor glands in 3. Multiple glands were involved in 9 patients. Staging was as follows: IE in 34, IIE in 12, IIIE in 2, and IV in 15 patients. Results: Surgery (S) alone was performed in 9, radiotherapy (RT) alone in 8, and chemotherapy (CT) alone in 4 patients. Forty-one patients received combined modality treatment (S + RT in 23, S + CT in 8, RT + CT in 4, and all three modalities in 6 patients). No active treatment was given in one case. After initial treatment there was no tumor in 57 patients and residual tumor in 5. Tumor progression was observed in 23 (36.5%) (local in 1, other salivary glands in 10, lymph nodes in 11, and elsewhere in 6). Five patients died of disease progression and the other 5 of other causes. The 5-year disease-free survival, disease-specific survival, and overall survival were 54.4%, 93.2%, and 81.7%, respectively. Factors influencing disease-free survival were use of RT, stage, and residual tumor (p < 0.01). Factors influencing disease-specific survival were stage, recurrence, and residual tumor (p < 0.01). Conclusions: To our knowledge, this report represents the largest series of MALT lymphomas of the salivary glands published to date. This disease may involve all salivary glands either initially or subsequently in 30% of patients. Recurrences may occur in up to 35% of patients at 5 years; however, survival is not affected. Radiotherapy is the only treatment modality that improves disease-free survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Radiation Therapy for Hodgkin Lymphoma: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group (ILROG)

Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solely on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗