Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Resistive AC-Coupled Silicon Detectors: principles of operation and first results from a combined analysis of beam test and laser data

This paper presents the principles of operation of Resistive AC-Coupled Silicon Detectors (RSDs) and measurements of the temporal and spatial resolutions using a combined analysis of laser and beam test data. RSDs are a new type of n-in-p silicon sensor based on the Low-Gain Avalanche Diode (LGAD) technology, where the n+ implant has been designed to be resistive, and the read-out is obtained via AC-coupling. The truly innovative feature of RSD is that the signal generated by an impinging particle is shared isotropically among multiple read-out pads without the need for floating electrodes or an external magnetic field. Careful tuning of the coupling oxide thickness and the n+ doping profile is at the basis of the successful functioning of this device. Several RSD matrices with different pad width-pitch geometries have been extensively tested with a laser setup in the Laboratory for Innovative Silicon Sensors in Torino, while a smaller set of devices have been tested at the Fermilab Test Beam Facility with a 120 GeV/c proton beam. The measured spatial resolution ranges between 2.5μm for 70–100 pad-pitch geometry and 17μm with 200–500 matrices, a factor of 10 better than what is achievable in binary read-out (bin size/12). Beam test data show a temporal resolution of ~40ps for 200 μm pitch devices, in line with the best performances of LGAD sensors at the same gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers

We demonstrate magnetic anomaly detection (MAD) using an array of 24 commercial induction coil magnetometers with stand-off distances from a pulsed 99.8(3) kA·m 2 magnetic dipole source of 260–1200 m. The sparse array is used to estimate the magnetic dipole location, magnitude, and orientation. We demonstrate how independent component analysis (ICA) improves the accuracy and precision of the magnetometer array when estimating the dipole parameters. Using sensor responses recorded from individual source pulses, we estimate the dipole location to within 29 ± 2 m, the magnitude to within 3 ± 3 kA·m 2 , and dipole orientation error to within 19 ± 0.6°.

47 OTHER INSTRUMENTATION↗

Saturnian trapped radiation and its absorption by satellites and rings - The first results from Pioneer 11

Preliminary results from Pioneer 11 concerning the acceleration and trapping of charged particles in the magnetic field of Saturn are reported. The identification and measurement of the intensities and spectra of charged particle species was performed by an experiment including four charged particle sensor systems, within 20 Saturn radii of the planet. Increases in the intensity of 0.5- to 1.8-MeV protons within 15 Saturn radii indicate the trapping and acceleration of particles in the dipole field region, while a decrease in proton intensity between seven and four Saturn radii is attributed to absorption by Dione and Enceladus and possibly ring material as well. Proton and electron intensity distributions are found to be axially symmetric within four Saturn radii, indicating a centered dipole aligned with the planetary rotation axis. Trapped radiation absorption at the orbit of Mimas is analyzed to obtain an upper limit of 4 x 10 to the -8th Saturn radii-squared/sec to the inward diffusion coefficient; an absorption-like feature observed at L = 2.5 is attributed to a previously unidentified satellite of diameter less than 200 km and semimajor axis 2.51 Saturn radii. Radiation absorption by the newly discovered F ring was also observed, however beneath the A, B and C rings a low flux of high-energy electrons was detected.

Simpson, J. A.↗

High-resolution imaging studies of the near-nucleus regions of comets

High-resolution, calibrated images of the near-nucleus regions of Halley, Giacobini-Zinner (for ICE encounter) and additional comets displaying widely differing levels of activity were acquired with a CCD sensor at the Cassegrain focus of the 3.6 m Canada-France-Hawaii Telescope (CFHT). The International Halley Watch designated interference filters were used. Successful correlation of ICE magnetic field data with the optical images obtained with the CFHT on the night of encounter (11 Sept. 1985) primarily through the H2O(+) and neighboring continuum passbands and with 300 km spatial resolution provokes reinterpretation of the observed structure of cometary ion tails. The observations of Halley, limited by bad weather, were made at significant periods of the apparition: the first, in December 1984 with the comet at 5.3 AU during the period of the onset of activity; and the last, in November 1985 with the comet near opposition. The December observations show evidence of residual activity. The 18 November data show a highly-condensed inner coma with an extreme falloff in brightness from the region of the nucleus. These data provide the basis for characterizing the gas and dust environment in the immediate vicinity of the active nucleus.

Goldberg, B. A.↗

Development of a vibration isolation prototype system for microgravity space experiments

The presence of small levels of low-frequency accelerations on the space shuttle orbiters has degraded the microgravity environment for the science community. Growing concern about this microgravity environment has generated interest in systems that can isolate microgravity science experiments from vibrations. This interest has resulted primarily in studies of isolation systems with active methods of compensation. The development of a magnetically suspended, six-degree-of-freedom active vibration isolation prototype system capable of providing the needed compensation to the orbital environment is presented. A design for the magnetic actuators is described, and the control law for the prototype system that gives a nonintrusive inertial isolation response to the system is also described. Relative and inertial sensors are used to provide an inertial reference for isolating the payload.

Logsdon, Kirk A.↗

Development of a vibration isolation prototype system for microgravity space experiments

The presence of small levels of low-frequency accelerations on the Space Shuttle orbiters has degraded the microgravity environment for the science community. Growing concern about this microgravity environment has generated interest in systems that can isolate microgravity science experiments from vibrations. This interest has resulted primarily in studies of isolation systems with active methods of compensation. The development of a magnetically suspended, six-degree-of-freedom active vibration isolation prototype system capable of providing the needed compensation to the orbital environment is presented. A design for the magnetic actuators is described, and the control law for the prototype system that gives a nonintrusive inertial isolation respone to the system is also described. Relative and inertial sensors are used to provide an inertial reference for isolating the payload.

Logsdon, K. A.↗

Gyro Evaluation for the Mission to Jupiter

As an important component in NASA's New Frontiers Program, the Jupiter Polar Orbiter (Juno) mission is designed to investigate in-depth physical properties of Jupiter. It will include the giant planet's ice-rock core and atmospheric studies as well as exploration of its polar magnetosphere. It will also provide the opportunity to understand the origin of the Jovian magnetic field. Due to severe radiation environment of the Jovian system, this mission inherently presents a significant technical challenge to Attitude Control System (ACS) design since the ACS sensors must survive and function properly to reliably maneuver the spacecraft throughout the mission. Different gyro technologies and their critical performance characteristics are discussed, compared and evaluated to facilitate a choice of appropriate gyro-based inertial measurement unit to operate in a harsh Jovian environment to assure mission success.

physical properties↗

Water Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently scheduled for March, 2009, after which the pump will be delivered to NASA for further testing.

Schuller, Michael↗

Implications of Weak-Link Behavior on the Performance of Mo/Au Bilayer Transition-Edge Sensors

Understanding the physical properties of the superconducting-to-normal transition is fundamental for optimizing the design and performance of transition-edge sensors (TESs). Recent critical current measurements of Mol Au bilayer test structures show that they act as weak superconducting links, exhibiting oscillatory, Fraunhofer-like behavior with applied magnetic field. In this paper we investigate the implications of this behavior for TES X-ray detectors, under operational bias conditions. These devices include normal metal features used for absorber attachment and unexplained noise suppression, which result in modifications to the previously reported critical current behavior. We present measurements of the logarithmic resistance sensitivity with temperature, a, and current, b, as a function of applied magnetic field and bias point within the resistive transition. Results show that these important device parameters exhibit similar oscillatory behavior with applied magnetic field, which in turn affects the signal responsivity and noise, and hence the energy resolution. These results show the significance of the critical current in determining the performance of TESs and hold promise to improve future.

Smith, Stephen J.↗

The InSight APSS Data Return Anomaly: Development of an Automated Detection and Response Method

The Auxiliary Payload Sensor Suite (APSS), a collection of environmental sensors carried by the Interior exploration using Seismic Investigations, Geodesy, and Heat Transport (InSight) lander, is capable of measuring Martian air temperature, wind speed, atmospheric pressure, and local magnetic fields. After beginning Mars surface operations, the instrument experienced an anomaly that prevented it from returning science data. The anomaly affected not only the instrument, but also had impacts at the system level. APSS returned to normal operations, however the anomaly occurred again just several weeks later. This proved the need for a streamlined recovery response that would be adaptable to the operations planning cycle and workforce, that would limit the system-level impacts of the anomaly, and that would minimize the instrument downtime. The recovery response evolved from a ground-in-the-loop response to an onboard method for detecting occurrences of the anomaly and automatically recovering the instrument. Ultimately, the automated detection and response method reduced instrument downtime from days to hours and significantly minimized science data loss.

Mittal, Nimisha↗

Building Datasets and Training Methods for ML Based Magnet Quench Detection

Detecting quenches in superconducting (SC) magnets during training is a challenging process that involves capturing physical events that occur at different frequencies and appear as various signal features. These events may be correlated across instrumentation type, thermal cycle, and ramp. These events together build a more complete picture of continuous processes occurring in the magnet, and may allow us to flag potential precursors for quench detection. We present our work on building an automatic machine learning (ML) based quench detection system. We build upon our existing work on unsupervised auto-encoders for acoustic sensors and quench antenna (QA) by first establishing a supervised ML training pipeline. We show the results of an event tagging, analysis, and simulation framework on our QA and acoustic data which are used concurrently to build a training dataset for a supervised implementation. We then show how this supervised training can be used as a prior in a semi-supervised framework and compare this to the unsupervised neural network auto-encoder performance.This allows us to have a more concrete understanding of the performance of our algorithms relative to physical events occurring in the magnet, and also provides a baseline software tool to generically evaluate our quench prediction autoencoders under completely unsupervised, supervised, and semi-supervised training conditions.

Khan, Maira [Fermilab]↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

Renewal: Coherent control of spin states in organic electronics – discovery and investigation of complex room-temperature magnetic quantum excitations

In the course of four funding cycles of this project, its research focused on the exploration and understanding of spin-dependent electronic processes in organic semiconductors. It aimed to investigate the potential of harnessing the spin degree of freedom in organic materials for various applications such as spin electronics, quantum information, sensors, and as well as quantum coherent spin phenomena of charge carrier states in organic semiconductors, with the aim to develop room-temperature-based quantum applications. Specifically, the project aimed to: Apply new diagnostic tools, i.e. spin spectroscopy techniques, for paramagnetic charge carrier states in organic semiconductors, based on coherent control with pulsed electron spin resonance to understand spin relaxation and spin mixing mechanisms in organic semiconductor materials and devices such as OLEDs. Explore the nature of charge carrier spin-coupling and pathways for its manipulation to control the physical behaviors of these materials. This involves investigating spin interactions through materials structure, composition, morphological dependencies, isotopic effects, and externally applied electric and magnetic fields, with the goal to manipulate electrical and optical material properties by adjusting spin-orbit, spin-dipolar, spin-exchange, as well as spin-hyperfine interactions to open up this materials class for new applications. Study spin-dependent charge carrier transport and recombination and how these observables are governed by spin-propagation, especially coherent spin propagation as well as collective spin-effects such as the spin-Dicke effect and resonant multi-photon magnetic dipole transitions. The project utilized pulsed electrically detected magnetic resonance (pEDMR) and pulsed optically detected magnetic resonance (pODMR) techniques over a wide frequency range. These techniques enabled the observation and quantification of various spin-spin coupling types, including spin-exchange, spin-dipolar, hyperfine, and spin-orbit interactions. The project will leverage low- to mid-frequency pEDMR/pODMR facilities and collaboration with the National High Magnetic Field Laboratory.

36 MATERIALS SCIENCE↗

Cryogenic Selective Surfaces

There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that can reject most of the Sun's energy and yet still provide some far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would be a benefit to deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. But perhaps the most significant enablement achieved from such a coating would be the long-term storage in deep space of cryogenic liquids, such as liquid oxygen (LOX).In this report, we review the state of the art in low-temperature coatings and calculate the lowest temperatures each of these can achieve, demonstrating that cryogenic temperatures cannot be reached in deep space in this fashion. We then propose a new coating that does allow coated objects in deep space to achieve the very low temperatures required to store liquid oxygen or nitrogen. These new coatings consist of a moderately thick scattering layer (typically 5 mm) composed of a material transparent to most of the solar spectrum. This layer acts as a scatterer to the Sun's light, performing the same process as titanium dioxide in white paint in the visible. Under that layer, we place a metallic reflector, e.g. silver, to reflect long-wave radiation that is not well scattered. The result is a coating we call "Solar White," in that it scatters most of the solar spectrum just as white paint does for the visible. Our modeling of these coatings has shown that temperatures as low as 50 K can be reached for a coated object fully exposed to sunlight at 1 AU from the Sun and far from the Earth.In the second half of the report we explore a mission application of this coating in order to show that it allows LOX to be carried on a mission to Mars. Heat can reach a LOX tank in five ways: direct radiation from the Sun, scattered or reflected radiation from the Sun off of spacecraft components, radiation from nearby planets or the Moon, radiation from the infrared emission of other parts of the spacecraft, and conduction along support struts and flow lines. We discuss these and sum their total contribution when using a Solar White coating to demonstrate an architecture that allows the transportation of LOX to Mars. After this, other applications of Solar White are listed.

Cryogenic Materials↗

Magnetically Attached Multifunction Maintenance Rover

A versatile mobile telerobot, denoted the magnetically attached multifunction maintenance rover (MAGMER), has been proposed for use in the inspection and maintenance of the surfaces of ships, tanks containing petrochemicals, and other large ferromagnetic structures. As its name suggests, this robot would utilize magnetic attraction to adhere to a structure. As it moved along the surface of the structure, the MAGMER would perform tasks that could include close-up visual inspection by use of video cameras, various sensors, and/or removal of paint by water-jet blasting, laser heating, or induction heating. The water-jet nozzles would be mounted coaxially within compressed-air-powered venturi nozzles that would collect the paint debris dislodged by the jets. The MAGMER would be deployed, powered, and controlled from a truck, to which it would be connected by hoses for water, compressed air, and collection of debris and by cables for electric power and communication (see Figure 1). The operation of the MAGMER on a typical large structure would necessitate the use of long cables and hoses, which can be heavy. To reduce the load of the hoses and cables on the MAGMER and thereby ensure its ability to adhere to vertical and overhanging surfaces, the hoses and cables would be paid out through telescopic booms that would be parts of a MAGMER support system. The MAGMER would move by use of four motorized, steerable wheels, each of which would be mounted in an assembly that would include permanent magnets and four pole pieces (see Figure 2). The wheels would protrude from between the pole pieces by only about 3 mm, so that the gap between the pole pieces and the ferromagnetic surface would be just large enough to permit motion along the surface but not so large as to reduce the magnetic attraction excessively. In addition to the wheel assemblies, the MAGMER would include magnetic adherence enhancement fixtures, which would comprise arrays of permanent magnets and pole pieces that could be adjusted to maximize or minimize the overall attractive magnetic force. Even with a paint thickness of 2 mm, a preliminary design provides a safety factor of 5 in the magnetic force in the upside- down, water-jets-operating condition, in which the total load (including the weight of the MAGMER and cables and the water-jet force) would be about 260 lb (the weight of 118 kg). Optionally, the MAGMER could carry magnetic shielding and/or could be equipped with a demagnetizing module to remove residual magnetism from the structure. The MAGMER would carry four charge-coupled-device cameras for visual inspection, monitoring of operation, navigation, and avoidance of collisions with obstacles. The control system of the MAGMER would include navigation and collision-avoidance subsystems that would utilize surface features as landmarks, in addition to direct images of obstacles.

Bar-Cohen, Yoseph↗

Inertial Orientation Trackers with Drift Compensation

A class of inertial-sensor systems with drift compensation has been invented for use in measuring the orientations of human heads (and perhaps other, similarly sized objects). These systems can be designed to overcome some of the limitations of prior orientation-measuring systems that are based, variously, on magnetic, optical, mechanical-linkage, and acoustical principles. The orientation signals generated by the systems of this invention could be used for diverse purposes, including controlling head-orientation-dependent virtual reality visual displays or enabling persons whose limbs are paralyzed to control machinery by means of head motions. The inventive concept admits to variations too numerous to describe here, making it necessary to limit this description to a typical system, the selected aspects of which are illustrated in the figure. A set of sensors is mounted on a bracket on a band or a cap that gently but firmly grips the wearer s head to be tracked. Among the sensors are three drift-sensitive rotationrate sensors (e.g., integrated-circuit angular- rate-measuring gyroscopes), which put out DC voltages nominally proportional to the rates of rotation about their sensory axes. These sensors are mounted in mutually orthogonal orientations for measuring rates of rotation about the roll, pitch, and yaw axes of the wearer s head. The outputs of these rate sensors are conditioned and digitized, and the resulting data are fed to an integrator module implemented in software in a digital computer. In the integrator module, the angular-rate signals are jointly integrated by any of several established methods to obtain a set of angles that represent approximately the orientation of the head in an external, inertial coordinate system. Because some drift is always present as a component of an angular position computed by integrating the outputs of angular-rate sensors, the orientation signal is processed further in a drift-compensator software module.

Foxlin, Eric M.↗

The Role of Marangoni Convection for the FZ-Growth of Silicon

Fluctuations of the electrical resistivity due to inhomogeneous dopant distribution are still a serious problem for the industrial processing yield of doped silicon crystals. In the case of silicon floating-zone growth, the main sources of these inhomogeneities are time- dependent flows in the liquid phase during the growth process. Excluding radio frequency (RF) induced convection, buoyancy and thermocapillary (Marangoni) convection are the two natural reasons for fluid flow. Both originate from temperature/concentration gradients in the melt, buoyancy convection through thermal/concentrational volume expansion, and thermocapillary convection through the temperature/concentration dependence of the surface tension. To improve the properties of grown crystals, knowledge of the strength, the characteristic, and the relation of these two flow mechanisms is essential. By the use of microgravity, the effect and the strength of buoyancy (gravity dependent) and thermocapillary (gravity independent) convection can be separated and clarified. Applying magnetic fields, both convective modes can be influenced: fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). Two complementary approaches have been pursued: Silicon full zones (experiments on the German sounding rockets TEXUS 7, 12, 22, 29, and 36) with the maximum temperature at half of the zone height and silicon half zones (experiments on the Japanese sounding rockets TR-IA4 and 6) with the maximum temperature at the top of the melt. With the full zone arrangement, the intensity and the frequency of the dopant striations could be determined and the critical Marangoni number could be identified. The half zone configuration is suited to classify the flow pattern and to measure the amplitude and the frequency of temperature fluctuations in the melt by inserting thermocouples or temperature sensors into the melt. All experiments have been carried out in monoellipsoid mirror furnaces. Typical zone geometries are approx. 8 to 14 mm in diameter and height. The crystals grown under microgravity are compared to crystals grown in static axial magnetic fields (B<5 tesla) and in transversal rotating magnetic fields (B<7.5 mT / f=50 Hz). Experimental results are completed by 3D numerical simulations: the obtained temperature and concentration distribution in the melt confirm the damping effect of rotating magnetic fields and explain the change in the radial segregation under static magnetic fields.

Dold, P.↗