Structural Analysis of the Support System for a Large Compressor Driven by a Synchronous Electric Motor

For economic reasons, the steam drive for a large compressor was replaced by a large synchronous electric motor. Due to the resulting large increase in mass and because the unit was mounted on a steel frame approximately 18 feet above ground level, it was deemed necessary to determine if a steady state or transient vibration problem existed. There was a definite possibility that a resonant or near resonant condition could be encountered. The ensuing analysis, which led to some structural changes as the analysis proceeded, did not reveal any major steady state vibration problems. However, the analysis did indicate that the system would go through several natural frequencies of the support structure during start-up and shutdown. This led to the development of special start-up and shutdown procedures to minimize the possibility of exciting any of the major structural modes. A coast-down could result in significant support structure and/or equipment damage, especially under certain circumstances. In any event, dynamic field tests verified the major analytical results. The unit has now been operating for over three years without any major vibration problems.

Winter, J. R.↗

The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation range adding full 3D functionality to a C-arm device retaining both handling comfort and the usability of 2D imaging. This method has a clear potential for clinical use especially to meet the increasing demand for an intraoperative 3D imaging.

60 APPLIED LIFE SCIENCES↗

SRM Internal Flow Tests and Computational Fluid Dynamic Analysis: RSRM Full Scale Motor Analyses - Volume 2

The purpose of the RSRM Nozzle Slag Ejection Precursor Test is to investigate the effect that slag ejection from the RSRM nozzle has on the chamber pressure and trust of the SRB's. In past firings of the Reusable Solid Rocket Motor (RSRM) both static test and flight motors have shown small pressure perturbations occurring primarily between 65 and 80 seconds. A joint NASA/Thiokol team investigation concluded that the cause of the pressure perturbations was the periodic ingestion and ejection of molten aluminum oxide slag from the cavity around the submerged nozzle nose which tends to trap and collect individual aluminum oxide droplets from the approach flow. The conclusions of the team were supported by numerous data and observations from special tests including high speed photographic films, real time radiography, plume calorimeters, accelerometers, strain gauges, nozzle TVC system force gauges, and motor pressure and thrust data. A simplistic slag ballistics model was formulated to relate a given pressure perturbation to a required slag quantity. Also, a cold flow model using air and water was developed to provide data on the relationship between the slag flow rate and the chamber pressure increase. Both the motor and the cold flow model exhibited low frequency oscillations in conjunction with periods of slag ejection. Motor and model frequencies were related to scaling parameters. The data indicate that there is a periodicity to the slag entrainment and ejection phenomena which is possibly related to organized oscillations from instabilities in the dividing streamline shear layer which impinges on the underneath surface of the nozzle.

Source record↗

Effects of Slag Ejection on Solid Rocket Motor Performance

In past firings of the Reusable Solid Rocket Motor (RSRM) both static test and flight motors have shown small pressure perturbations occurring primarily between 65 and 80 seconds. A joint NASA/Thiokol team investigation concluded that the cause of the pressure perturbations was the periodic ingestion and ejection of molten aluminum oxide slag from the cavity around the submerged nozzle nose which tends to trap and collect individual aluminum oxide droplets from the approach flow. The conclusions of the team were supported by numerous data and observations from special tests including high speed photographic films, real time radiography, plume calorimeters, accelerometers, strain gauges, nozzle TVC system force gauges, and motor pressure and thrust data. A simplistic slag ballistics model was formulated to relate a given pressure perturbation to a required slag quantity. Also, a cold flow model using air and water was developed to provide data on the relationship between the slag flow rate and the chamber pressure increase. Both the motor and the cold flow model exhibited low frequency oscillations in conjunction with periods of slag ejection. Motor and model frequencies were related to scaling parameters. The data indicate that there is a periodicity to the slag entrainment and ejection phenomena which is possibly related to organized oscillations from instabilities in the dividing streamline shear layer which impinges on the underneath surface of the nozzle.

Whitesides, R. Harold↗

A Cryogenically-Cooled MW Inverter for Electric Aircraft Propulsion

Power electronic converter will be a key enabler for future electrified aircraft propulsion system. In aircraft applications, superconducting technologies such as superconducting motors and generators along with supporting power systems will grow in importance. Utilizing cryogenic cooling for power converter potentially can significantly improve the inverter system efficiency and specific power. This paper presents the cooling, hardware,and testing of a cryogenically-cooled MW inverter developed for electrified aircraft propulsion system. The 1 MVA full load testing with cryogenic cooling is demonstrated. The developed inverter system achieves 18 kVA/kg specific power and 99% efficiency, which provides a promising solution to achieve high power density and efficiency for future electrified aircraft propulsion system.

cryogenically-cooled inverter↗

Determination of Functional Capabilities, the Level of Physical Performance and the State of Main Physiological Body Systems in the First Hours after the Accomplishment of Long-term Space Flights ("Field Test")

Long-term stay in weightlessness is accompanied by alterations in the activity of main physiological body systems including sensory-motor, skeletal-muscular disturbances and cardiovascular deconditioning. However, up to now, there are no data on the state and level of functional performance of cosmonauts/astronauts directly after flight, nor are there data to help define the dynamic recovery of functional characteristics and work efficiency which are greatly needed to provide the safety and planning of their activity once they reach space objects. The Russian and American scientists are currently engaged in a joint experiment known as the "Field Test" with the goal of studying the functional performance and the state of main physiological body systems directly after landing and their temporal recovery dynamics. The functional performance is identified during the test by temporal characteristics of the movements of spatial translation, the stability of the vertical stance for 3.5 min, and the kinematic characteristics of walking - non-complicated and complicated. The following characteristics are identified as physiological characteristics of the test: a) orthostatic tolerance during stand test, b) back muscle tone; c) vertical stability - by characteristics of the correction responses to unexpected perturbations of the vertical stance, and d) support reactions during the performance of the full battery of tests. To date, a pilot version of the "Field Test" has been conducted with participation from four Russian cosmonauts. The results of studies have shown that in 1 - 5 hours after landing the functional abilities of the cosmonauts are considerably reduced. All the test movements at this time are considerably slower than preflight and the more complicated the task is, the greater significant reduction in orthostatic tolerance: during the first test that occurs 1 - 5 hours after landing. two of four cosmonauts declined to continue the task after the orthostatic test (one of them did not wear the anti-G suit "Centaurus" during testing). Blood pressure during moving out of prone posture to vertical stance in one of the cosmonauts and of sitting to standing position in the other dropped to the precollapse level. The results of the studies have confirmed the feasibility, the usefulness and the safety of conducting tests as close as possible to the landing. The program of "Field Test" experiment will be continued and extended.

Kozlovskaya, Inesa↗

Shuttle Propulsion System Major Events and the Final 22 Flights

Numerous lessons have been documented from the Space Shuttle Propulsion elements. Major events include loss of the Solid Rocket Boosters (SRB's) on STS-4 and shutdown of a Space Shuttle Main Engine (SSME) during ascent on STS-51F. On STS-112 only half the pyrotechnics fired during release of the vehicle from the launch pad, a testament for redundancy. STS-91 exhibited freezing of a main combustion chamber pressure measurement and on STS-93 nozzle tube ruptures necessitated a low liquid level oxygen cut off of the main engines. A number of on pad aborts were experienced during the early program resulting in delays. And the two accidents, STS-51L and STS-107, had unique heritage in history from early program decisions and vehicle configuration. Following STS-51L significant resources were invested in developing fundamental physical understanding of solid rocket motor environments and material system behavior. And following STS-107, the risk of ascent debris was better characterized and controlled. Situational awareness during all mission phases improved, and the management team instituted effective risk assessment practices. The last 22 flights of the Space Shuttle, following the Columbia accident, were characterized by remarkable improvement in safety and reliability. Numerous problems were solved in addition to reduction of the ascent debris hazard. The Shuttle system, though not as operable as envisioned in the 1970's, successfully assembled the International Space Station (ISS). By the end of the program, the remarkable Space Shuttle Propulsion system achieved very high performance, was largely reusable, exhibited high reliability, and was a heavy lift earth to orbit propulsion system. During the program a number of project management and engineering processes were implemented and improved. Technical performance, schedule accountability, cost control, and risk management were effectively managed and implemented. Award fee contracting was implemented to provide performance incentives. The Certification of Flight Readiness and Mission Management processes became very effective. A key to the success of the propulsion element projects was related to relationships between the MSFC project office and support organizations with their counterpart contractor organizations. The teams worked diligently to understand and satisfy requirements and achieve mission success.

Owen, James W.↗

SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many preclinical applications including focused drug delivery and thermal therapy. Funding support provided by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

The qualification of the shuttle booster separation motors

Four booster separation motors (BSM) located at each end of every solid rocket booster (SRB) provide the needed side force to separate the boosters from the external tank at booster burnout. Four BSMs at the top of the SRB are located in a box pattern in the nose cone frustum. The four BSMs at the aft end of the SRB are arranged side-by-side on the SRB aft skirt. Aspects of BSM design and performance are considered, taking into account a motor design/performance summary, the case design, the insulation, the grain design, the nozzle/aft closure design, the ignition system, the propellant, and the motor assembly. Details of motor testing are also discussed, giving attention to development testing, qualification testing, and flight testing.

Chase, C. A.↗

The digital control of an experiment to size particles using a laser

Efforts to automate an experiment for sizing particles using a laser is described. The objective of the experiment was to rotate a photomultiplier detector at various angles and to record data associated with how light interacted with a particle. The light source was a laser which was fixed in space. The design consisted of a step motor with a fabricated electromechanical system to rotate the photomultiplier. The use of an 8080 microprocessor based microcomputer to control the step motor and to log data is described.

Cross, J. E.↗

Effects of space flight on locomotor control

In the microgravity environment of spaceflight, the relationship between sensory input and motor output is altered. During prolonged missions, neural adaptive processes come into play to recalibrate central nervous system function, thereby permitting new motor control strategies to emerge in the novel sensory environment of microgravity. However, the adaptive state achieved during spaceflight is inappropriate for a unit gravity environment and leads to motor control alterations upon return to Earth that include disturbances in locomotion. Indeed, gait and postural instabilities following the return to Earth have been reported in both U.S. astronauts and Russian cosmonauts even after short duration (5- to 10-day) flights. After spaceflight, astronauts may: (1) experience the sensation of turning while attempting to walk a straight path, (2) encounter sudden loss of postural stability, especially when rounding corners, (3) perceive exaggerated pitch and rolling head movements during walking, (4) experience sudden loss of orientation in unstructured visual environments, or (5) experience significant oscillopsia during locomotion.

Bloomberg, Jacob J.↗

Thermal protection system and related methods

A thermal protection system and a method of manufacturing are disclosed. The thermal protection system may be configured to protect a movable joint, for example, a flexible bearing of a rocket motor nozzle. The thermal protection system includes a series of annular shims separated by a plurality of discrete spacers. Each shim of the series of annular shims may have a larger diameter than the previous shim, and the shims may nest. The shims may comprise a thermally stable material, and the discrete spacers may comprise an elastomer. Optionally, an annular bearing protector may separate the annular shims from the flexible bearing.

Garbe, Duane J.↗

The 15-meter antenna performance optimization using an interdisciplinary approach

A 15-meter diameter deployable antenna has been built and is being used as an experimental test system with which to develop interdisciplinary controls, structures, and electromagnetics technology for large space antennas. The program objective is to study interdisciplinary issues important in optimizing large space antenna performance for a variety of potential users. The 15-meter antenna utilizes a hoop column structural concept with a gold-plated molybdenum mesh reflector. One feature of the design is the use of adjustable control cables to improve the paraboloid reflector shape. Manual adjustment of the cords after initial deployment improved surface smoothness relative to the build accuracy from 0.140 in. RMS to 0.070 in. Preliminary structural dynamics tests and near-field electromagnetic tests were made. The antenna is now being modified for further testing. Modifications include addition of a precise motorized control cord adjustment system to make the reflector surface smoother and an adaptive feed for electronic compensation of reflector surface distortions. Although the previous test results show good agreement between calculated and measured values, additional work is needed to study modelling limits for each discipline, evaluate the potential of adaptive feed compensation, and study closed-loop control performance in a dynamic environment.

Grantham, William L.↗

Accelerometer telemetry system

An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

Konigsberg, E.↗

Status of the Delco Systems Operations forward looking windshear detection program

Delco Systems Operations, a division of General Motors Hughes Electronics Corporation, is developing a Forward Looking Windshear Detection System based on the integration of infrared remote sensing and accelerometer reactive sensing technologies. The infrared sensor is a multi-spectral, scanning radiometer operating in the 8 to 14 micron region. A 2 x 5 detector array with parallel-serial scanning produces 60 degrees horizontal and 10 degrees vertical-fields of view. Using multiple wavelength signals, azimuth temperature gradients are analyzed for characteristic signatures of thermally induced windshear phenomena. Elevation temperature gradients are processed through an atmosphere model to continuously compute a stability index for arming microburst detection criteria. The atmosphere model and proprietary computer processing algorithms combine to generate coarse estimates of disturbance ranges based on multiple wavelength radiance data with different extinction coefficients. Computer outputs of atmospheric stability, disturbance intensity, and azimuth and range information provide a situation display capability. A ground operated, experimental radiometer has been developed and is being used to verify the detection and discrimination concepts at an atmospheric and simulated rain test facility in Milwaukee. A prototype airborne radiometer is being developed for flight test evaluation during the summer of 1989.

Gallagher, Brian J.↗

Baseline Testing of The EV Global E-Bike

The NASA John H. Glenn Research Center initiated baseline testing of the EV Global E-Bike as a way to reduce pollution in urban areas, reduce fossil fuel consumption and reduce Operating costs for transportation systems. The work was done Linder the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The E-Bike is a state of the art, ground up, hybrid electric bicycle. Unique features of the vehicle's power system include the use of an efficient, 400 W. electric hub motor and a 7-speed derailleur system that permits operation as fully electric, fully pedal, or a combination of the two. Other innovative features, such as regenerative braking through ultracapacitor energy storage are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. The E-Bike is an inexpensive approach to advance the state of the art in hybrid technology in a practical application. The project transfers space technology to terrestrial use via nontraditional partners, and provides power system data valuable for future space applications. A description of the E-bike, the results of performance testing, and future vehicle development plans is the subject of this report. The report concludes that the E-Bike provides excellent performance, and that the implementation of ultracapacitors in the power system can provide significant performance improvements.

Eichenberg, Dennis J.↗

Investing American Recovery and Reinvestment Act Funds to Advance Capability, Reliability, and Performance in NASA Wind Tunnels

The National Aeronautics and Space Administration's (NASA) Aeronautics Test Program (ATP) is implementing five significant ground-based test facility projects across the nation with funding provided by the American Recovery and Reinvestment Act (ARRA). The projects were selected as the best candidates within the constraints of the ARRA and the strategic plan of ATP. They are a combination of much-needed large scale maintenance, reliability, and system upgrades plus creating new test beds for upcoming research programs. The projects are: 1.) Re-activation of a large compressor to provide a second source for compressed air and vacuum to the Unitary Plan Wind Tunnel at the Ames Research Center (ARC) 2.) Addition of high-altitude ice crystal generation at the Glenn Research Center Propulsion Systems Laboratory Test Cell 3, 3.) New refrigeration system and tunnel heat exchanger for the Icing Research Tunnel at the Glenn Research Center, 4.) Technical viability improvements for the National Transonic Facility at the Langley Research Center, and 5.) Modifications to conduct Environmentally Responsible Aviation and Rotorcraft research at the 14 x 22 Subsonic Tunnel at Langley Research Center. The selection rationale, problem statement, and technical solution summary for each project is given here. The benefits and challenges of the ARRA funded projects are discussed. Indirectly, this opportunity provides the advantages of developing experience in NASA's workforce in large projects and maintaining corporate knowledge in that very unique capability. It is envisioned that improved facilities will attract a larger user base and capabilities that are needed for current and future research efforts will offer revenue growth and future operations stability. Several of the chosen projects will maximize wind tunnel reliability and maintainability by using newer, proven technologies in place of older and obsolete equipment and processes. The projects will meet NASA's goal of integrating more efficient, environmentally safer, and less energy consuming hardware and processes into existing tunnel systems. These include Environmental Protection Agency-approved refrigerants, energy efficient motors, and faster, flexible tunnel data systems.

Sydnor, Goerge H.↗

Multi-System Effects of Daily Artificial Gravity Exposures in Humans Deconditioned by Bed Rest

We have begun to explore the utility of intermittent artificial gravity (AG) as a multi-system countermeasure to the untoward health and performance effects of adaptation to decreased gravity during prolonged space flight. The first study in this exploration was jointly designed by an international, multi-disciplinary team of scientists interested in standardizing an approach so that comparable data could be obtained from follow-on studies performed in multiple international locations. Fifteen rigorously screened male volunteers participated in the study after providing written informed consent. All were subjected to 21 days of 6deg head-down-tilt (HDT) bed rest. Eight were treated with daily 1hr AG exposures (2.5g at the feet decreasing to 1.0g at the heart) aboard a short radius (3m) centrifuge, while the other seven served as controls. Multiple observations were made of dependent measures in the bone, muscle, cardiovascular, sensory-motor, immune, and behavioral systems during a 10 day acclimatization period prior to HDT bed rest and again during an 8 day recovery period after the bed rest period. Comparisons between the treatment and control subjects demonstrated salutary effects of the AG exposure on aspects of the muscle and cardiovascular systems, with no untoward effects on the vestibular system, the immune system, or cognitive function. Bone deconditioning was similar between the treatment and control groups, suggesting that the loading provided by this specific AG paradigm was insufficient to protect that system from deconditioning. Future work will be devoted to varying the loading duty cycle and/or coupling the AG loading with exercise to provide maximum physiological protection across all systems. Testing will also be extended to female subjects. The results of this study suggest that intermittent AG could be an effective multi-system countermeasure.

Paloski, William H.↗