Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

X-Ray Induced Chemical Reaction Revealed by In Situ X-Ray Diffraction and Scanning X-Ray Microscopy in 15 nm Resolution

The detection sensitivity of synchrotron-based X-ray techniques has been largely improved due to the ever-increasing source brightness, which has significantly advanced ex situ and in situ research for energy materials such as lithium-ion batteries. However, the strong beam–material interaction arising from the high beam flux can substantially modify the material structure. The beam-induced parasitic effect inevitably interferes with the intrinsic material property, making the interpretation of the experimental results difficult and requiring comprehensive assessments. Here, we present a quantitative study of the beam effect on an electrode material Ag 2 VO 2 PO 4 using four different X-ray characterization methods with different radiation dose rates. The material system exhibits interesting and reversible radiation-induced thermal and chemical reactions, further evaluated under electron microscopy to illustrate the underlying mechanism. Further, the work will provide a guideline for using synchrotron X-rays to distinguish the intrinsic behavior from extrinsic structure change of materials induced by X-rays.

36 MATERIALS SCIENCE↗

Enhancing Diagnosis through AI-driven Analysis of Reflectance Confocal Microscopy

Reflectance Confocal Microscopy (RCM) is a non-invasive imaging technique used in biomedical research and clinical dermatology. It provides virtual high-resolution images of the skin and superficial tissues, reducing the need for physical biopsies. RCM employs a laser light source to illuminate the tissue, capturing the reflected light to generate detailed images of microscopic structures at various depths. Recent studies explored AI and machine learning, particularly CNNs, for analyzing RCM images. Our study proposes a segmentation strategy based on textural features to identify clinically significant regions, empowering dermatologists in effective image interpretation and boosting diagnostic confidence. This approach promises to advance dermatological diagnosis and treatment.

Yoon, Hong-Jun↗

Ultrahigh-resolution scanning microwave impedance microscopy of moiré lattices and superstructures

Two-dimensional heterostructures composed of layers with slightly different lattice vectors exhibit new periodic structure known as moiré lattices, which, in turn, can support novel correlated and topological phenomena. Moreover, moiré superstructures can emerge from multiple misaligned moiré lattices or inhomogeneous strain distributions, offering additional degrees of freedom in tailoring electronic structure. High-resolution imaging of the moiré lattices and superstructures is critical for understanding the emerging physics. Here, we report the imaging of moiré lattices and superstructures in graphene-based samples under ambient conditions using an ultrahigh-resolution implementation of scanning microwave impedance microscopy. Although the probe tip has a gross radius of ~100 nm, spatial resolution better than 5 nm is achieved, which allows direct visualization of the structural details in moiré lattices and the composite super-moiré. We also demonstrate artificial synthesis of novel superstructures, including the Kagome moiré arising from the interplay between different layers.

36 MATERIALS SCIENCE↗

Picosecond carrier dynamics in InAs and GaAs revealed by ultrafast electron microscopy

Understanding the limits of spatiotemporal carrier dynamics, especially in III-V semiconductors, is key to designing ultrafast and ultrasmall optoelectronic components. However, identifying such limits and the properties controlling them has been elusive. Here, using scanning ultrafast electron microscopy, in bulk n-GaAs and p-InAs, we simultaneously measure picosecond carrier dynamics along with three related quantities: subsurface band bending, above-surface vacuum potentials, and surface trap densities. We make two unexpected observations. First, we uncover a negative-time contrast in secondary electrons resulting from an interplay among these quantities. Second, despite dopant concentrations and surface state densities differing by many orders of magnitude between the two materials, their carrier dynamics, measured by photoexcited band bending and filling of surface states, occur at a seemingly common timescale of about 100 ps. This observation may indicate fundamental kinetic limits tied to a multitude of material and surface properties of optoelectronic III-V semiconductors and highlights the need for techniques that simultaneously measure electro-optical kinetic properties.

42 ENGINEERING↗

Discovery of spontaneous mesoscopic strain waves in nematic domains using dark-field x-ray microscopy

Electronic nematic order arises when correlated electrons spontaneously break the rotational symmetry of a crystal lattice. When electronic nematic order couples bilinearly to symmetry-breaking lattice strain, both appear together at a single ferroelastic phase transition, producing structural twin domains with distinct orientations of the nematic director. While the effects of applied strain on these domains are well established, the intrinsic behavior of spontaneous subdomain strain fields has remained unexplored. Here, we report the discovery of spontaneous mesoscopic strain waves within individual nematic domains of an iron-based superconductor, observed using dark-field x-ray microscopy (DFXM). Using this advanced full-field imaging technique, we visualize subdomain strain modulations emerging concurrently with nematic order. Elastic compatibility relations governing inhomogeneous strains provide a natural mechanism for the strain waves. Our findings reveal a broadly relevant form of strain self-organization and position DFXM as a powerful probe of the local interplay between lattice strain and electronic order.

36 MATERIALS SCIENCE↗

Single-molecule infrared spectroscopy with scanning tunneling microscopy

Probing vibrations at the single-molecule level is essential for achieving bond-specific chemical control in realistic heterogeneous environments. Here, we introduce a new measurement scheme that integrates frequency-tunable infrared excitation with scanning tunneling microscopy to characterize vibration-mediated nuclear motions of single molecules. We first validated the technique by monitoring the infrared-induced rotation of the ethynyl radical and then applied it to mapping pyrrolidine’s conformational dynamics. The resulting broadband spectra captured fundamental vibrational modes together with rich overtone and combination bands inaccessible by conventional methods, which we confirmed with isotopic substitutions. Density functional theory calculations showed that delocalized modes coupled with pyrrolidine ring puckering drive the structural transition, revealing altered selection rules compared with traditional infrared spectroscopy. Here, this new experimental platform enables molecular vibrations and transformations to be probed with atomic precision.

Liang, Kangkai [University of California, San Dieg↗

Microscopy Studies of the Catalyst Inks for PEM Fuel Cells

The microstructure of the catalyst layer in proton exchange membrane fuel cells (PEMFC) is one of the key factors that determine fuel cell performance. The ink preparation, including dispersion solvent, mixing time, and mixing power, are among the less reported parameters that would influence the ionomer distribution on the catalyst surface and the continuity of the carbon network. In this work, novel characterization approaches have been used to investigate the effect of the Pt/C catalyst ink preparation conditions on the morphology and structures of the catalyst layer. Microscopy analysis revealed that longer mixing time led to better performing electrode structures than shorter mixing time. The longer mixing time enabled improved continuity of the ionomer network and high porosity in the cathode layer that contributes to improved proton conductivity and mass transport. This has been reflected in performance and durability tests, where the electrode made from a 5-day catalyst ink displayed improved performance compared to the one made from a 3-day ink. Durability studies showed 26% and 43% loss of the initial mass activity for 5 days and 3 days mixing, respectively. Finally, in addition, the catalyst layer prepared with ethylene glycol as the dispersion solvent showed better durability than water/1-propanol based solution.

25 ENERGY STORAGE↗

Understanding the Selective Deposition of Li Metal on Nonuniform Electrode Surfaces Using Atomic Force Microscopy

The use of lithium metal in secondary batteries has been impeded by its tendency to form dendrites: branching conductive structures of metal that can lead to capacity loss and, ultimately, internal shorts in the battery. Patterned electrodes, in addition to artificially increasing the current density of cells by increasing the surface area available for reaction, also generate a nonuniform electric field in the vicinity of the electrode surface. This nonuniform electric field, though rapidly screened by the electrolyte, can promote inhomogeneous deposition and Solid Electrolyte Interphase formation. As the consequence of these effects is not theoretically apparent since Solid Electrolyte Interphase volume and conductivity changes can, in principle, offset variations in local current density, we have performed experiments to examine the deposition of Li on nonuniform electrode surfaces using Atomic Force Microscopy. In this work, we measure the local variations in topography, SEI thickness, and composition, and discuss their implications for the formation of dendrites in Li metal.

25 ENERGY STORAGE↗

Elucidating Sodium-Sulfur Battery Chemistry using Operando Transmission X-ray Microscopy and X-ray Absorption Spectroscopy

Room-temperature sodium-sulfur (Na-S) batteries offer a beneficial and cost-effective solution for powering modern electric grids and devices. However, Na-S batteries suffer from performance decay during battery cycling due to the sluggish kinetics and polysulfide shuttling. Revealing the conversion mechanism of the Na-S chemistry is critical to designing high-capacity and stable Na-S batteries. In this study, we employed operando X-ray microscopy and operando X-ray absorption spectroscopy to elucidate the sulfur conversion in a carbon host using an ether-based electrolyte. We reveal the structural and chemical evolution of the sulfur cathode during cycling, which results in volume expansion and the dissolution of active material, ultimately affecting the battery performance. Our work provides fundamental insight into the sulfur reaction scheme, addressing the lingering challenges before establishing inexpensive Na-S batteries for broad applications, including portable electronics and large-scale energy storage.

Jagadeesan, Sathya Narayanan [SLAC National Accele↗

Microstructural Study of Hydration of C 3 S in the Presence of Calcium Nitrate Using Scanning Transmission X-Ray Microscopy (STXM)

Calcium nitrate (CN) is used widely as an effectively inorganic setting accelerator and antifreeze admixture in concrete structures. In this paper, the multiscale investigation of CN on the hydration of C 3 S was studied by scanning transmission X-ray microscopy (STXM) combined with near-edge X-ray absorption fine structure (NEXAFS), 29 Si MAS NMR, calorimetry, scanning electron microscope, and N 2 absorption. It was concluded that the calcium silicate hydrate (C-S-H) surrounds the unhydrated C 3 S at 1-day hydrated C 3 S in the presence of calcium nitrate, while portlandite is partly in transformation and is formed partly. Based on Ca L 3 , 2 -edge NEXAFS spectra for 1-day hydrated C 3 S particle, calcium nitrate does not change the structure of the asymmetrically 7-fold coordination of calcium in the C-S-H. Calcium nitrate can accelerate the hydration of C 3 S to some extent and polymerization of the silicate chains within C-S-H considerably at early age, resulting in the increasing specific surface area.

Li, Qinfei↗

#COVIDisAirborne: AI-enabled multiscale computational microscopy of delta SARS-CoV-2 in a respiratory aerosol

We seek to completely revise current models of airborne transmission of respiratory viruses by providing never-before-seen atomic-level views of the SARS-CoV-2 virus within a respiratory aerosol. Our work dramatically extends the capabilities of multiscale computational microscopy to address the significant gaps that exist in current experimental methods, which are limited in their ability to interrogate aerosols at the atomic/molecular level and thus obscure our understanding of airborne transmission. We demonstrate how our integrated data-driven platform provides a new way of exploring the composition, structure, and dynamics of aerosols and aerosolized viruses, while driving simulation method development along several important axes. We present a series of initial scientific discoveries for the SARS-CoV-2 Delta variant, noting that the full scientific impact of this work has yet to be realized.

60 APPLIED LIFE SCIENCES↗

Advanced Modes of Electrostatic and Kelvin Probe Force Microscopy for Energy Applications

Since their invention over three decades ago, electrostatic and Kelvin probe force microscopies (EFM and KPFM) have become primary tools for the characterization of electrical phenomena on the nanometer scale, with multiple applications for ferroelectrics, photovoltaics, batteries, and fuel cells among a myriad of other energy-related materials. Meanwhile, the techniques have undergone remarkable advances in terms of resolution, sensitivity, and informational content (e.g., dynamic information). In this chapter, we review the operational principles behind classical EFM/KPFM, including the various excitation/detection schemes, while also highlighting potential cross-talk and instrumental issues. Beyond classical approaches, we will describe more recent advances involving open loop detection, multifrequency/multidimensional excitation, and time-resolved methods. Finally, potential pathways for the further development of EFM/KPFM at the solid-liquid interface are discussed.

Checa, Marti↗

Live cell imaging of cellular dynamics in poplar wood using computational cannula microscopy

This study presents significant advancements in computational cannula microscopy for live imaging of cellular dynamics in poplar wood tissues. Leveraging machine-learning models such as pix2pix for image reconstruction, we achieved high-resolution imaging with a field of view of 55µm using a 50µm-core diameter probe. Our method allows for real-time image reconstruction at 0.29 s per frame with a mean absolute error of 0.07. We successfully captured cellular-level dynamics in vivo , demonstrating morphological changes at resolutions as small as 3µm. We implemented two types of probabilistic neural network models to quantify confidence levels in the reconstructed images. This approach facilitates context-aware, human-in-the-loop analysis, which is crucial for in vivo imaging where ground-truth data is unavailable. Using this approach we demonstrated deep in vivo computational imaging of living plant tissue with high confidence (disagreement score ⪅0.2). This work addresses the challenges of imaging live plant tissues, offering a practical and minimally invasive tool for plant biologists.

Ingold, Alexander (ORCID:0009000752380016)↗

Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400–1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8–24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10–50 MHz. Imaging results showed that tungsten filaments yielded 1.1–4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120–200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

Hsu, Hsun-Chia↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Confined hyperbolic metasurface modes for structured illumination microscopy

Plasmonic hyperbolic metasurfaces have emerged as an effective platform for manipulating the propagation of light. Here, confined modes on arrays of silver nanoridges that exhibit hyperbolic dispersion are used to demonstrate and model a super-resolution imaging technique based on structured illumination microscopy. A spatial resolution of ∼75 nm at 458 nm is demonstrated, which is 3.1 times better than an equivalent diffraction limited image. This work emphasizes the ability to engineer the properties of confined optical modes and to leverage those characteristics for applications in imaging. The results of this work could lead to improved approaches for super-resolution imaging using designed sub-wavelength structures.

42 ENGINEERING↗

Rapid multiplex ultrafast nonlinear microscopy for material characterization

We demonstrate rapid imaging based on four-wave mixing (FWM) by assessing the quality of advanced materials through measurement of their nonlinear response, exciton dephasing, and exciton lifetimes. We use a WSe 2 monolayer grown by chemical vapor deposition as a canonical example to demonstrate these capabilities. By comparison, we show that extracting material parameters such as FWM intensity, dephasing times, excited state lifetimes, and distribution of dark/localized states allows for a more accurate assessment of the quality of a sample than current prevalent techniques, including white light microscopy and linear micro-reflectance spectroscopy. We further discuss future improvements of the ultrafast FWM techniques by modeling the robustness of exponential decay fits to different spacing of the sampling points. Employing ultrafast nonlinear imaging in real-time at room temperature bears the potential for rapid in-situ sample characterization of advanced materials and beyond.

36 MATERIALS SCIENCE↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗