Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASUREMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Bubble Point Measurements of Three Binary Mixtures of Refrigerants: R-32/1234yf, R-32/1234ze(E), and R-1132a/1234yf

In this article, bubble point pressures of three binary mixtures at two compositions each have been measured utilizing a static method. The mixtures studied were difluoromethane + 2,3,3,3-tetrafluoroprop-1-ene (R-32/1234yf), difluoromethane + (E)-1,3,3,3-tetrafluoroprop-1-ene (R-32/1234ze(E)), and 1,1-difluoroethene + 2,3,3,3-tetrafluoroprop-1-ene (R-1132a/1234yf). For all of the mixtures, the minimum temperature measured was 270 K. The maximum temperatures measured for the R-32/1234ze(E), R-32/1234yf, and R-1132a/1234yf mixtures were 360, 345, and 325 K, respectively. A total of 100 bubble point pressures are reported and compared to available literature data relative to the REFPROP database. Lemmon, E. W. [ NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, 10.0; National Institute of Standards and Technology, Standard Reference Data Program: Gaithersburg, 2018]. Additionally, the bubble point pressures obtained in this study are modeled using the perturbed-chain statistical associating fluid theory (PC-SAFT) equation of state. The PC-SAFT model parameters, as well as deviations of this work and literature data from the model, are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Entangled Photon Correlations Allow a Continuous-Wave Laser Diode to Measure Single-Photon, Time-Resolved Fluorescence

Fluorescence lifetime experiments are a standard approach for measuring excited state dynamics and local environment effects. Here, we show that entangled photon pairs produced from a continuous-wave (CW) laser diode can replicate pulsed laser experiments without phase modulation. As a proof of principle, picosecond fluorescence lifetimes of indocyanine green are measured in multiple environments. Here, the use of entangled photons has three unique advantages. First, low power CW laser diodes and entangled photon source design lead to straightforward on-chip integration for a direct path to distributable fluorescence lifetime measurements. Second, the entangled pair wavelength is easily tuned by temperature or electric field, allowing a single source to cover octave bandwidths. Third, femtosecond temporal resolutions can be reached without requiring major advances in source technology or external phase modulation. Entangled photons could therefore provide increased accessibility to time-resolved fluorescence while also opening new scientific avenues in photosensitive and inherently quantum systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Measurements of Charge Transfer at Cocatalyst/Semiconductor Interfaces in BiVO 4 Particle Photocatalysts

Semiconductor photocatalyst particles convert solar energy to fuels like H 2 . The particles are often assumed to provide crystalline-facet-dependent electron-hole separation. A common strategy is to deposit HER electrocatalyst on electron-selective facets and OER electrocatalyst on hole-selective facets. A precise understanding of how charge-carrier-selective contacts emerges and how they rationally designed, however, is missing. Using a combination of ex-situ and in-situ conducting-AFM experiments and new ionomer/catalyst-semiconductor test structures, we show how heterogeneity in charge-carrier selectivity can be measured at the nanoscale. We discover that the presence of interface water/electrolyte is critical to induce hole selectivity between the CoO x water-oxidation catalyst and the BiVO 4 light absorber. pH-dependent measurements suggest that negative surface charge on the semiconductor is central to inducing hole selectivity. Furthermore, the work also demonstrates a new approach to control local pH and introduce water using thin-film ionomers compatible with conductive-AFM measurements.

14 SOLAR ENERGY↗

Sample-Averaged Biexciton Quantum Yield Measured by Solution-Phase Photon Correlation

The brightness of nanoscale optical materials such as semiconductor nanocrystals is currently limited in high excitation flux applications by inefficient multiexciton fluorescence. We have devised a solution-phase photon correlation measurement that can conveniently and reliably measure the average biexciton-to-exciton quantum yield ratio of an entire sample without user selection bias. This technique can be used to investigate the multiexciton recombination dynamics of a broad scope of synthetically underdeveloped materials, including those with low exciton quantum yields and poor fluorescence stability. Here in this study, we have applied this method to measure weak biexciton fluorescence in samples of visible-emitting InP/ZnS and InAs/ZnS core/shell nanocrystals, and to demonstrate that a rapid CdS shell growth procedure can markedly increase the biexciton fluorescence of CdSe nanocrystals.

36 MATERIALS SCIENCE↗

Validation of aerosol extinction and water vapor profiles from routine Atmospheric Radiation Measurement Climate Research Facility measurements

The accuracy with which vertical profiles of aerosol extinction σ ep (λ) can be retrieved from ARM Climate Research Facility (ACRF) routine measurements was assessed using data from two airborne field campaigns, the ARM Aerosol Intensive Operation Period (AIOP, May 2003), and the Aerosol Lidar Validation Experiment (ALIVE, September 2005). This assessment pertains to the aerosol at its ambient concentration and thermodynamic state (i.e. σ ep (λ) either free of or corrected for sampling artifacts) and includes the following ACRF routine methods: Raman Lidar, Micro Pulse Lidar (MPL) and in-situ aerosol profiles (IAP) with a small aircraft. Profiles of aerosol optical depth τp(λ), from which the profiles of σep(λ)are derived through vertical differentiation, were measured by the NASA Ames Airborne Tracking 14-channel Sunphotometer (AATS-14); these data were used as truth in this evaluation. The ACRF IAP σ ep (550 nm) were lower by 16% (during AIOP) and higher by 10% (during ALIVE) when compared to AATS-14. The ACRF MPL σ ep (523 nm) were higher by 24% (AIOP) and 19%-21% (ALIVE) compared to AATS-14 but the correlation improved significantly during ALIVE. In the AIOP a second MPL operated by NASA showed a smaller positive bias (13%) with respect to AATS-14. The ACRF Raman Lidar σ ep (355 nm) were higher by 54% (AIOP) and higher by 6% (ALIVE) compared to AATS-14. The large bias in AIOP stemmed from a gradual loss of the sensitivity of the Raman Lidar starting about the end of 2001 going unnoticed until after AIOP. A major refurbishment and upgrade of the instrument and improvements to a data-processing algorithm led to the significant improvement and very small bias in ALIVE. Finally we find that during ALIVE the Raman Lidar water vapor densities ρw are higher by 8% when compared to AATS-14, whereas comparisons between AATS-14 and in-situ measured ρw aboard two different aircraft showed small negative biases (0 to -3%).

47 OTHER INSTRUMENTATION↗

The 235 U prompt fission neutron spectrum measured by the Chi-Nu project at LANSCE

The Chi-Nu experiment aims to accurately measure the prompt fission neutron spectrum for the major actinides. At the Los Alamos Neutron Science Center (LANSCE), fission can be induced with neutrons ranging from 0.7 MeV and above. Using a two arm time-of-flight (TOF) technique, the fission neutrons are measured in one of two arrays: a 22- 6 Li glass array for lower energies, or a 54-liquid scintillator array for outgoing energies of 0.5 MeV and greater. Presented here are the collaboration's preliminary efforts at measuring the 235 U PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving nuclear data evaluations with predictive reaction theory and indirect measurements

Nuclear reaction data required for astrophysics and applications is incomplete, as not all nuclear reactions can be measured or reliably predicted. Neutron-induced reactions involving unstable targets are particularly challenging, but often critical for simulations. In response to this need, indirect approaches, such as the surrogate reaction method, have been developed. Nuclear theory is key to extract reliable cross sections from such indirect measurements. We describe ongoing efforts to expand the theoretical capabilities that enable surrogate reaction measurements. We focus on microscopic predictions for charged-particle inelastic scattering, uncertainty-quantified optical nucleon-nucleus models, and neural-network enhanced parameter inference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurements of the Proton Elastic Form Factor Ratio

New high precision polarization measurements of the proton elastic form factor ratio in the Q{sup 2} range from 0.3 to 0.7 [GeV/c]{sup 2} have been made. These elastic H(e, e'p) measurements were done in Jefferson Lab's Hall A using 80% longitudinally polarized electrons and recoil polarimetry. For 1 [GeV/c]{sup 2}, previous polarization data indicated a strong deviation of the form factor ratio from unity which sparked renewed theoretical and experimental interest in how two-photon diagrams have been taken into account. The new high precision data indicate that the deviation from unity, while small, persists even at Q{sup 2} less than 1 [GeV/c]{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase-controlled, heterodyne laser-induced transient grating measurements of thermal transport properties in opaque material

The methodology for a heterodyned laser-induced transient thermal grating technique for non-contact, non-destructive measurements of thermal transport in opaque material is presented here. Phase-controlled heterodyne detection allows us to isolate pure phase or amplitude transient grating signal contributions by varying the relative phase between reference and probe beams. The phase grating signal includes components associated with both transient reflectivity and surface displacement whereas the amplitude grating contribution is governed by transient reflectivity alone. By analyzing the latter with the two-dimensional thermal diffusion model, we extract the in-plane thermal diffusivity of the sample. Measurements on a 5 μm thick single crystal PbTe film yielded excellent agreement with the model over a range of grating periods from 1.6 to 2.8 μm. The measured thermal diffusivity of 1.3 × 10 -6 m 2 /s was found to be slightly lower than the bulk value.

36 MATERIALS SCIENCE↗

Comparisons of angularly and spectrally resolved Bremsstrahlung measurements to two-dimensional multi-stage simulations of short-pulse laser-plasma interactions

A 2-D multi-stage simulation model incorporating realistic laser conditions and a fully resolved electron distribution handoff has been developed and compared to angularly and spectrally resolved Bremsstrahlung measurements from high-Z planar targets. For near-normal incidence and 0.5-1 × 10{sup 20} W/cm{sup 2} intensity, particle-in-cell (PIC) simulations predict the existence of a high energy electron component consistently directed away from the laser axis, in contrast with previous expectations for oblique irradiation. Measurements of the angular distribution are consistent with a high energy component when directed along the PIC predicted direction, as opposed to between the target normal and laser axis as previously measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of transmission efficiency for 400 MeV proton beam through collimator at Fermilab MuCool Test Area using Chromox-6 scintillation screen

The MuCool Test Area (MTA) at Fermilab is a facility to develop the technology required for ionization cooling for a future Muon Collider and/or Neutrino Factory. As part of this research program, feasibility studies of various types of RF cavities in a high magnetic field environment are in progress. As a unique approach, we have tested a RF cavity filled with a high pressure hydrogen gas with a 400 MeV proton beam in an external magnetic field (B = 3 T). Quantitative information about the number of protons passing through this cavity is an essential requirement of the beam test. The MTA is a flammable gas (hydrogen) hazard zone. Due to safety reasons, no active (energized) beam diagnostic instrument can be used. Moreover, when the magnetic field is on, current transformers (toroids) used for beam intensity measurements do not work due to the saturation of the ferrite material of the transformer. Based on these requirements, we have developed a passive beam diagnostic instrumentation using a combination of a Chromox-6 scintillation screen and CCD camera. This paper describes details of the beam profile and position obtained from the CCD image with B = 0 T and B = 3 T, and for high and low intensity proton beams. A comparison is made with beam size obtained from multi-wires detector. Beam transmission efficiency through a collimator with a 4 mm diameter hole is measured by the toroids and CCD image of the scintillation screen. Results show that the transmission efficiency estimated from the CCD image is consistent with the toroid measurement, which enables us to monitor the beam transmission efficiency even in a high magnetic field environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting low concentrations of plutonium hydride with magnetization measurements

We report the formation of plutonium hydride in 2 at. % Ga-stabilized δ-Pu, with 1 at. % H charging. We show that magnetization measurements are a sensitive, quantitative measure of ferromagnetic plutonium hydride against the nonmagnetic background of plutonium. It was previously shown that at low hydrogen concentrations, hydrogen forms super-abundant vacancy complexes with plutonium, resulting in a bulk lattice contraction. Here, we use magnetization, X-ray, and neutron diffraction measurements to show that in addition to forming vacancy complexes, at least 30% of the H atoms bond with Pu to precipitate PuH{sub x} on the surface of the sample with x ∼ 1.9. We observe magnetic hysteresis loops below 40 K with magnetic remanence, consistent with ferromagnetic PuH{sub 1.9}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the tradeoff between intrinsic emittance and quantum efficiency from a NaKSb photocathode near threshold

We measure the tradeoff between the quantum efficiency and intrinsic emittance from a NaKSb photocathode at three increasing wavelengths (635, 650, and 690 nm) at or below the energy of the bandgap plus the electron affinity, hν≤E{sub g}+E{sub a}. These measurements were performed using a high voltage dc gun for varied photocathode surface fields of 1.4−4.4 MV/m. Measurements of intrinsic emittance are performed using two different methods and were found to agree. At the longest wavelength available, 690 nm, the intrinsic emittance was 0.26 μm/mm-rms with a quantum efficiency of ∼10{sup −4}. The suitability of NaKSb emitting at threshold for various low emittance applications is discussed.

36 MATERIALS SCIENCE↗

Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raman spectroscopy measurement of bilayer graphene's twist angle to boron nitride

When graphene is placed on hexagonal boron nitride with a twist angle, new properties develop due to the resulting moiré superlattice. Here, we report a method using Raman spectroscopy to make rapid, non-destructive measurements of the twist angle between bilayer graphene and hexagonal boron nitride. The lattice orientation is determined by using flakes with both bilayer and monolayer regions, and using the known Raman signature for the monolayer to measure the twist angle of the entire flake. The widths of the second order Raman peaks are found to vary linearly in the superlattice period and are used to determine the twist angle. The results are confirmed by using transport measurements to infer the superlattice period by the charge density required to reach the secondary resistance peaks. Small twist angles are also found to produce a significant modification of the first order Raman G band peak.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗