Permeation Resistance of Personal Protective Equipment Materials to Monomethyhydrazine
Permeation resistance was determined by measuring the breakthrough time and time-averaged vapor transmission rate of monomethylhydrazine (MMH) through two types of personal protective equipment (PPE). The two types of PPE evaluated were the totally encapsulating ILC Dover Chemturion Model 1212 chemical protective suit with accessories, and the FabOhio polyvinyl chloride (PVC) splash garment. Two exposure scenarios were simulated: (1) a saturated vapor exposure for 2 hours (h), and (2) a brief MMH 'splash' followed by a 2-h saturated vapor exposure. Time-averaged MMH concentrations inside the totally-encapsulating suit were calculated by summation of the area-weighted contributions made by each suit component. Results show that the totally encapsulating suit provides adequate protection at the new 10 ppb Threshold Limit Value Time-Weighted Average (TLV-TWA). The permeation resistance of the PVC splash garment to MMH was poorer than any of the totally encapsulating suit materials tested. Breakthrough occurred soon after initial vapor or 'splash' exposure.