Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Analysis and improvement of detection accuracy for a wireless motion sensing system using integrated coil component

Integration of the exciting coil and the pick-up coil array for the wireless magnetic motion sensing system has been investigated to clear the limitation of the system arrangement. From the comparison of the integrated-type and the sandwich-type, which was proposed by our previous study, regardless of the lower signal-to-noise ratio of the integrated-type than that of the sandwich-type a repeatable detection accuracy of around 1 mm is obtained at the distance of 120 mm from the pick-up coil array (sandwich-type: up to 140 mm). A different tendency of the detection errors in detection was also observed. In spite of different tendency, the cause of the errors has been clarified. The impedance change of the exciting coil due to a resonance of the LC marker perturbs strength of the magnetic field which is used for marker excitation. However, the errors are able to compensate to the actual positions and orientations of the marker by using compensatory method which was already established.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional representations of axisymmetric fields for computer calculations

An accurate representation of axisymmetric fields has been devised by extending the method of ideal current loops to off-axis fields. It is assumed that the data to be simulated are available through measurements or through a solution of a boundary value problem. The method provides an algebraic expression for the fields throughout a two-dimensional region of interest and eliminates the need for the axial expansion formula in approximating off-axis fields. The use of Gaussian and other functions as alternatives to the coil function is proposed. Examples of the technique in simulating a periodic permanent magnet (PPM) focusing field are presented and compared with a Fourier analysis of the problem.

Stankiewicz, N.↗

Conceptual Design of A 20 T Dipole Based on Hybrid REBCO/Nb 3 Sn Cos-theta Coil

This paper presents a design concept of an HTS/LTS hybrid dipole with 50 mm aperture and 20 T nominal field based on a cos-theta coil and a cold iron yoke. The HTS part of magnet coil uses REBCO Twisted Stacked Tape cable. The LTS part is graded and made of two Nb3Sn Rutherford cables. Due to high sensitivity of HTS/LTS coils to large stresses and strains at high fields, a Stress Management (SM) concept combined with the cos-theta coil geometry is used. The results of magnet magnetic analysis are presented and discussed.

43 PARTICLE ACCELERATORS↗

Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test of Optimized 120-mm LARP Nb 3 Sn Quadrupole Coil Using Magnetic Mirror Structure

The U.S. Large Hadron Collider accelerator research program is developing a new generation of large-aperture high-field quadrupoles based on Nb 3 Sn conductor for the high-luminosity upgrade of the Large Hadron Collider. Tests of the first series of 120-mm-aperture high-gradient quadrupole (HQ) coils revealed the necessity for further optimization of the coil design and fabrication process. Modifications in coil design were gradually implemented in two HQ coils previously tested at Fermi National Accelerator Laboratory using a magnetic mirror structure (HQM01 and HQM02). This paper describes the construction and test of an HQ mirror model with a coil of optimized design and with an interlayer resistive core in the conductor. The cable for this coil was made of a smaller diameter strand, providing more room for coil expansion during reaction. The 0.8-mm strand, used in all previous HQ coils, was replaced with a 0.778-mm Nb 3 Sn strand of RRP 108/127 subelement design. The coil was instrumented with voltage taps, heaters, and strain gauges to monitor mechanical and thermal properties and quench performance of the coil

43 PARTICLE ACCELERATORS↗

Optical patterning of magnetic domains and defects in ferromagnetic liquid crystal colloids

A promising approach in designing composite materials with an unusual physical behavior combines solid nanostructures and orientationally ordered soft matter at the mesoscale. Such composites can not only inherit properties of their constituents but also can exhibit emergent behavior such as ferromagnetic ordering of colloidal metal nanoparticles forming mesoscopic magnetization domains when dispersed in a nematic liquid crystal. Here, we demonstrate the optical patterning of domain structures and topological defects in such ferromagnetic liquid crystal colloids, which allows for altering their response to magnetic fields. Furthermore, our findings reveal the nature of the defects in this soft matter system which is different as compared to non-polar nematics and ferromagnets alike.

36 MATERIALS SCIENCE↗

Heterogeneous Superconducting Low-Noise Sensing Coils

A heterogeneous material construction has been devised for sensing coils of superconducting quantum interference device (SQUID) magnetometers that are subject to a combination of requirements peculiar to some advanced applications, notably including low-field magnetic resonance imaging for medical diagnosis. The requirements in question are the following: The sensing coils must be large enough (in some cases having dimensions of as much as tens of centimeters) to afford adequate sensitivity; The sensing coils must be made electrically superconductive to eliminate Johnson noise (thermally induced noise proportional to electrical resistance); and Although the sensing coils must be cooled to below their superconducting- transition temperatures with sufficient cooling power to overcome moderate ambient radiative heat leakage, they must not be immersed in cryogenic liquid baths. For a given superconducting sensing coil, this combination of requirements can be satisfied by providing a sufficiently thermally conductive link between the coil and a cold source. However, the superconducting coil material is not suitable as such a link because electrically superconductive materials are typically poor thermal conductors. The heterogeneous material construction makes it possible to solve both the electrical- and thermal-conductivity problems. The basic idea is to construct the coil as a skeleton made of a highly thermally conductive material (typically, annealed copper), then coat the skeleton with an electrically superconductive alloy (typically, a lead-tin solder) [see figure]. In operation, the copper skeleton provides the required thermally conductive connection to the cold source, while the electrically superconductive coating material shields against Johnson noise that originates in the copper skeleton.

Hahn, Inseob↗

A Feasibility Study of Electromagnetic De-Spin System for Earth Orbiting Satellites

This investigation is a feasibility study of electromagnetic satellite de-spin systems based on induced eddy-currents in the satellite by an external dc magnetic field. Two concepts have been investigated: (1) one based on a large diameter coil positioned around the satellite such that the axis of the satellite rotation is in the plane of the coil; and (2) a magnet, either permanent or electromagnet, positioned close to the satellite by the orbiter RMS. A comparison is made of the two concepts by varying the appropriate parameters with a view to reduce the de-spin time to a reasonable value. Design parameters for the magnets and the coil are indicated.

Prasad K Kadaba↗

The null magnetic field as reference for the study of geomagnetic directional effects in animals and man.

Techniques for producing very low and zero magnetic fields are considered, giving attention to the compensation of the geomagnetic field by a Helmholtz coil system, approaches utilizing the shielding power of highly permeable alloys, and the complete exclusion of the geomagnetic field with the aid of a superconductive shield. Animal experiments in low magnetic fields are discussed, together with the exposure of man to 'null' magnetic fields and the Josephson junction as a possible biosensor of magnetic fields. It is found that neither the functions nor the behavior of man changes significantly during a two-week exposure to magnetic fields below 50 gammas.

Beischer, D. E.↗

First results from the new RIKEN superconducting electron cyclotron resonance ion source (invited)

The next generation heavy ion accelerator facility, such as the RIKEN radio isotope (RI) beam factory, requires an intense beam of high charged heavy ions. In the past decade, performance of the electron cyclotron resonance (ECR) ion sources has been dramatically improved with increasing the magnetic field and rf frequency to enhance the density and confinement time of plasma. Furthermore, the effects of the key parameters (magnetic field configuration, gas pressure, etc.) on the ECR plasma have been revealed. Such basic studies give us how to optimize the ion source structure. Based on these studies and modern superconducting (SC) technology, we successfully constructed the new 28 GHz SC-ECRIS, which has a flexible magnetic field configuration to enlarge the ECR zone and to optimize the field gradient at ECR point. Using it, we investigated the effect of ECR zone size, magnetic field configuration, and biased disk on the beam intensity of the highly charged heavy ions with 18 GHz microwaves. In this article, we present the structure of the ion source and first experimental results with 18 GHz microwave in detail.

43 PARTICLE ACCELERATORS↗

Plasma Measurements in an Integrated-System FARAD Thruster

Pulsed inductive plasma accelerators are spacecraft propulsion devices in which energy is stored in a capacitor and then discharged through an inductive coil. The device is electrodeless, inducing a current sheet in a plasma located near the face of the coil. The propellant is accelerated and expelled at a high exhaust velocity (order of 10 km/s) through the interaction of the plasma current and the induced magnetic field. The Faraday Accelerator with RF-Assisted Discharge (FARAD) thruster[1,2] is a type of pulsed inductive plasma accelerator in which the plasma is preionized by a mechanism separate from that used to form the current sheet and accelerate the gas. Employing a separate preionization mechanism allows for the formation of an inductive current sheet at much lower discharge energies and voltages than those used in previous pulsed inductive accelerators like the Pulsed Inductive Thruster (PIT). A benchtop FARAD thruster was designed following guidelines and similarity performance parameters presented in Refs. [3,4]. This design is described in detail in Ref. [5]. In this paper, we present the temporally and spatially resolved measurements of the preionized plasma and inductively-accelerated current sheet in the FARAD thruster operating with a Vector Inversion Generator (VIG) to preionize the gas and a Bernardes and Merryman circuit topology to provide inductive acceleration. The acceleration stage operates on the order of 100 J/pulse. Fast-framing photography will be used to produce a time-resolved, global view of the evolving current sheet. Local diagnostics used include a fast ionization gauge capable of mapping the gas distribution prior to plasma initiation; direct measurement of the induced magnetic field using B-dot probes, induced azimuthal current measurement using a mini-Rogowski coil, and direct probing of the number density and electron temperature using triple probes.

Polzin, K. A.↗

Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5 m × 2.5 m × 3 m, disturbances of the magnetic field are attenuated by factors of 5–50 at a bandwidth from 10{sup −3} Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the neutron electric dipole moment measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probes for measuring fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch

Several probes have been constructed to measure fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch (RFP). The magnetic probe is composed of six magnetic pickup coil triplets. The triplets are separated spatially, which allows for local measurements of the Maxwell stress. To measure the plasma flow components for evaluation of the Reynolds stress, we employ a combination of an optical probe [Kuritsyn et al., Rev. Sci. Indrum. 77, 10F112 (2006)] and a Mach probe. The optical probe measures the radial ion flow locally using Doppler spectroscopy. The Mach probe consists of four current collectors biased negatively with respect to a reference tip and allows for measurements of the poloidal and toroidal components of the bulk plasma flow. The stresses are observed to play an important role in the momentum balance in the RFP edge during internal reconnection events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Fields on the National Ignition Facility (MagNIF)

A magnetized target capability on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) has been investigated. Stakeholders’ needs and project feasibility analysis were considered in order to down-select from a wide variety of different potential magnetic field magnitudes and volumes. From the large range of different target platforms, laser configurations, and diagnostics configurations of interest to the stakeholders, the gas-pipe platform has been selected for the first round of magnetized target experiments. Gas pipe targets are routinely shot on the NIF and provide unique value for external collaborators. High-level project goals have been established including an experimentally relevant 20Tesla magnetic field magnitude. The field will be achieved using pulsed power-driven coils. A system architecture has been proposed. The pulsed power drive system will be located in the NIF target bay. This decision provides improved maintainability and mitigates equipment safety risks associated with explosive failure of the drive capacitor. High-level and first-level subsystem requirements have been established. Requirements have been included for two distinct coil designs – full solenoid and quasi-Helmholtz. A Failure Modes and Effects Analysis (FMEA) has been performed and documented. Additional requirements have been derived from the mitigations included in the FMEA document. A project plan is proposed. The plan includes a first phase of electromagnetic simulations to assess whether the design will meet performance requirements, then a second phase of risk mitigation projects to address the areas of highest technical risk. The duration from project kickoff to the first magnetized target shot is approximately 29 months.

42 ENGINEERING↗

Electromagnetic design, engineering development and magnetic qualification of a horizontal layered scaled magnet for physics experiments

Neutrino detectors around the world have shown evidence that these weakly interacting, little-understood particles are not really mass less, as was thought so far. Not only do they have non-zero masses, different species (or flavors) of neutrinos seem to mix and oscillate into one another as they traverse through the cosmos. If this is true, this is not only one of the first pieces of evidence for physics beyond the so-called Standard Model of Particle Physics, but would also have great impact on diverse fields such as nuclear and particle physics, astrophysics and cosmology. It is thus imperative to study the details of the interactions of these particles. These will be detected by means of an iron calorimeter (ICAL), comprising detectors sandwiched in alternate layers of soft magnetic iron. The iron core is magnetized to allow bending of the charged particles. The direction and the energy of the original incoming neutrino, that caused the interaction, can then be accurately determined. Racetrack coils through slots cut in the iron core create a uniform magnetic field in the iron core. A highly uniform magnetic field in the soft iron core is required to accurately determine the mass and energy of incident particle. The charged particles bend in this magnetic field; oppositely charged particles bending in opposite directions. The charge, energy and momentum of the emitted particle is thus determined. An electromagnet was designed as a laboratory facility for conducting experimental studies in particle physics. This paper discusses the electromagnetic design, development, fabrication, magnetic qualification and magnetic measurement issues of an electromagnet developed for physics studies. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FLORA Equilibrium and Stability Code Archive

FLORA solves, in a 2-D domain (radial and axial dimensions) with a specified azimuthal Fourier mode, for the linearized stability of a long, thin, axisymmetric plasma equilibrium in an applied magnetic field. Before the stability equation is solved, FLORA solves a set of simple equations for pressure balance that specify the equilibrium magnetic field and plasma pressure in the long-thin limit given a simplified description of the magnetic coils. It uses an initial-value method for the linear stability problem in which an equilibrium is given an initial perturbation to its magnetic field, and the temporal behavior of the perturbation is followed. The perturbation has been Fourier expanded in the azimuthal coordinate; each azimuthal mode must be examined separately. The complex partial differential equation of motion for the perturbed radial displacement of the field lines is solved as a coupled system of two real p.d.e.'s and the solution consists of two parts, the real part and the imaginary part. The system is solved by bringing the coupling terms in each equation to the right side and using an iterative technique.

Cohen, Bruce [Lawrence Livermore National Laborato↗

A novel design of iron dominated superconducting multipole magnets with circular coils

Linear accelerators based on superconducting magnet technology use a large number of relatively weak superconducting quadrupoles. In this case an iron dominated quadrupole is the most cost effective solution. The field quality in this magnet is defined by iron poles; the magnet air gap is minimal as are coil ampere-turns. Nevertheless, it has long racetrack type coils, which must be rigid and fixed by a mechanical structure to provide the needed mechanical stability. The novel concept of using circular superconducting coils in such a quadrupole type is described, with a discussion of quadrupole parameters, and results of 3D magnetic designs. Variants of short and long sectional quadrupoles and multipoles are presented.

43 PARTICLE ACCELERATORS↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗