Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHT SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Advanced X-ray Optics Metrology for Nanofocusing and Coherence Preservation

What is the point of developing new high-brightness light sources if beamline optics won't be available to realize the goals of nano-focusing and coherence preservation? That was one of the central questions raised during a workshop at the 2007 Advanced Light Source Users Meeting. Titled, 'Advanced X-Ray Optics Metrology for Nano-focusing and Coherence Preservation', the workshop was organized by Kenneth Goldberg and Valeriy Yashchuk (both of Lawrence Berkeley National Laboratory, LBNL), and it brought together industry representatives and researchers from Japan, Europe, and the US to discuss the state of the art and to outline the optics requirements of new light sources. Many of the presentations are viewable on the workshop website http://goldberg.lbl.gov/MetrologyWorkshop07/. Many speakers shared the same view of one of the most significant challenges facing the development of new high-brightness third and fourth generation x-ray, soft x-ray, and EUV light sources: these sources place extremely high demands on the surface quality of beamline optics. In many cases, the 1-2-nm surface error specs that define the outer bounds of 'diffraction-limited' quality are beyond the reach of leading facilities and optics vendors. To focus light to 50-nm focal spots, or smaller, from reflective optics and to preserve the high coherent flux that new sources make possible, the optical surface quality and alignment tolerances must be measured in nano-meters and nano-radians. Without a significant, well-supported research effort, including the development of new metrology techniques for use both on and off the beamline, these goals will likely not be met. The scant attention this issue has garnered is evident in the stretched budgets and limited manpower currently dedicated to metrology. With many of the world's leading groups represented at the workshop, it became clear that Japan and Europe are several steps ahead of the US in this critical area. But the situation isn't all dire: several leading groups are blazing a trail forward, and the recognition of this issue is increasing. The workshop featured eleven invited talks whose presenters came from Japan, Europe, and the US.

36 MATERIALS SCIENCE↗

Light Extinction Tomography for Measurement of Ice Crystals and Other Small Particles

A tomography duct for wind tunnels includes a plurality of light sources and sensors displaced around a support structure. The light sources are cycled and sensor measurements are made from sensors opposite the light sources. Tomographic algorithms are used to determine an extinction map from the sensor measurements. The extinction map provides details about particles in a cross-section of the air flow through the tomography duct.

Bencic, Timothy J.↗

Optical sedimentation recorder

A robotic optical sedimentation recorder is described for the recordation of carbon flux in the oceans wherein both POC and PIC particles are captured at the open end of a submersible sampling platform, the captured particles allowed to drift down onto a collection plate where they can be imaged over time. The particles are imaged using three separate light sources, activated in sequence, one source being a back light, a second source being a side light to provide dark field illumination, and a third source comprising a cross polarized light source to illuminate birefringent particles. The recorder in one embodiment is attached to a buoyancy unit which is capable upon command for bringing the sedimentation recorder to a programmed depth below the ocean surface during recordation mode, and on command returning the unit to the ocean surface for transmission of recorded data and receipt of new instructions. The combined unit is provided with its own power source and is designed to operate autonomously in the ocean for extended periods of time.

47 OTHER INSTRUMENTATION↗

Phosphors for near UV-Emitting LED's for Efficacious Generation of White Light

1) We studied phosphors for near-UV (nUV) LED application as an alternative to blue LEDs currently being used in SSL systems. We have shown that nUV light sources could be very efficient at high current and will have significantly less binning at both the chip and phosphor levels. We identified phosphor blends that could yield 4100K lamps with a CRI of approximately 80 and LPWnUV,opt equal to 179 for the best performing phosphor blend. Considering the fact that the lamps were not optimized for light coupling, the results are quite impressive. The main bottleneck is an optimum blue phosphor with a peak near 440 nm with a full width half maximum of about 25 nm and a quantum efficiency of >95%. Unfortunately, that may be a very difficult task when we want to excite a phosphor at ~400 nm with a very small margin for Stokes shift. Another way is to have all the phosphors in the blend having the excitation peak at 400 nm or slightly shorter wavelength. This could lead to a white light source with no body color and optimum efficacy due to no self-absorption effects by phosphors in the blend. This is even harder than finding an ideal blue phosphor, but not necessarily impossible. 2) With the phosphor blends identified, light sources using nUV LEDs at high current could be designed with comparable efficacy to those using blue LEDs. It will allow us to design light sources with multiple wattages using the same chips and phosphor blends simply by varying the input current. In the case of blue LEDs, this is not currently possible because varying the current will lower the efficacy at high current and alter the color point. With improvement of phosphor blends, control over CRI could improve. Less binning at the chip level and also at the phosphor blend level could reduce the cost of SSL light sources. 3) This study provided a deeper understanding of phosphor characteristics needed for LEDs in general and nUV LEDs in particular. Two students received Ph.D. degrees and three undergraduates participated in this work. Two of the undergraduate students are now in graduate school. The results were widely disseminated – 20 archival journal publications (published, accepted or in preparation) and three conference proceedings resulted. The students presented their work at 11 different national/international conferences (32 oral or poster presentations) and the PI’s delivered 12 invited, keynote or plenary lectures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attitude sensor

A device for controlling the attitude of a spacecraft is described. The device consists of two light sensors on a spacecraft that are mounted beneath a baffle which divides the light from a light source such as the sun or a star. The divided light reflects off of two reflective surfaces onto the two light sensors. When the spacecraft assumes its normal attitude, the baffle divides the light source into two equal parts, causing the two light sensors to produce equal outputs. When the light is equally detected, the stabilizing system is disconnected. Deviations from the normal attitude cause unequal distribution of the light source and energize the stabilizing system.

Newcomb, A. L., Jr.↗

Biosensors for EVA: Improved Instrumentation for Ground-based Studies

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared LED light source. The compact grating spectrometer was replaced with a chip-scale spectrometer. With this new design, the sensor is 4 in 2 in 0.5 in, weighs 60 g, and no fiber optic cables are needed. The sensor, which contains the light source and the spectrometer, is adhered directly to the skin with medical grade adhesive. The sensor can be powered via the USB port of the laptop computer that controls the sensor operation. Alternatively, for studies in the spacesuit, the sensor can be powered by a small battery pack and operated by an ultra-portable hand-held computer. Both the handheld computer and battery pack will easily fit within the PLSS of the test spacesuit. System automation was significantly improved, to add features suggested by our colleagues in the Cardiovascular Laboratory and the NASA JSC Exercise Physiology and Countermeasures Project. The functionality and portability of this system were demonstrated in our UMass laboratory.

Soller, B.↗

Out-of-Focus Alinement of Solar Concentrators

In new alinement technique, no attempt made to simulate infinitely distant light source, and all mirrors left uncovered throughout procedure. Light source placed at distance of 1,650 feet (503 m); other distances used. Alinement of approximately 250 mirror facets of paraboloidal solar concentrator simplified by precalculated images reflected from all facets. Developed for large solar concentrators, technique used with other multiplemirror or multiple-light-source systems for producing specified illuminance patterns.

Argoud, M. J.↗

Time-resolved spectroscopy using a chopper wheel as a fast shutter

Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LED lamp incorporating remote phosphor with heat dissipation features

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and a remote planar phosphor carrier having at least one conversion material. The phosphor carrier can be remote to the light sources and mounted to the heat sink so that heat from the phosphor carrier spreads into the heat sink. The phosphor carrier can comprise a thermally conductive transparent material and a phosphor layer, with an LED based light source mounted to the heat sink such that light from the light source passes through the phosphor carrier. At least some of the LED light is converted by the phosphor carrier, with some lamp embodiments emitting a white light combination of LED and phosphor light. The phosphor arranged according to the present invention can operate at lower temperature to thereby operate at greater phosphor conversion efficiency and with reduced heat related damage to the phosphor.

36 MATERIALS SCIENCE↗

Synchrotron Light Options at Super-B

Super-B is a planned asymmetric high luminosity e{sup +}e{sup -} collider at the {Upsilon}(4S) resonance as PEP-II and KEKB, to be built in Italy. The Super-B High (HER, 7 GeV) and Low (LER, 4 GeV) Energy beams characteristics are comparable to NSLS-II and other state of the art synchrotron light sources. This suggests the use of this facility, either parasitically or in dedicated runs, as light source. In this paper we compare the characteristics of the synchrotron light generated at Super-B with existing, in construction and proposed facilities. We investigate different schemes to incorporate the generation of synchrotron radiation in the collider lattice design and look at different beam line layouts for users. In the past high energy particle colliders were designed to collide as many particle as possible. This was done by maximizing the beam current, using relative large emittances and squeezing the beam at the interaction point. During the operation of PEP II the limits of both raising the beam currents and squeezing the beam were experienced. Therefore the optics was modified to lower emittance. The successful test of the 'large Piwinski angle' and crab waist scheme, with extremely low design emittances, at the DAPHNE collider at Frascati made it the design choice for Super-B. Both HER and LER have been designed to meet these requirements and the design parameters relevant to our study, are shown in Table 1. As comparison the design parameters from NSLS II and other state of the art synchrotron light sources have been added to this table. From these parameters it is obvious that synchrotron radiation generated from both HER and LER is comparable to this last generation sources.

43 PARTICLE ACCELERATORS↗

Spectral quality affects disease development of three pathogens on hydroponically grown plants

Plants were grown under light-emitting diode (LED) arrays with various spectra to determine the effects of light quality on the development of diseases caused by tomato mosaic virus (ToMV) on pepper (Capsicum annuum L.), powdery mildew [Sphaerotheca fuliginea (Schlectend:Fr.) Pollaci] on cucumber (Cucumis sativus L.), and bacterial wilt (Pseudomonas solanacearum Smith) on tomato (Lycopersicon esculentum Mill.). One LED (660) array supplied 99% red light at 660 nm (25 nm bandwidth at half-peak height) and 1% far-red light between 700 to 800 nm. A second LED (660/735) array supplied 83% red light at 660 nm and 17% far-red light at 735 nm (25 nm bandwidth at half-peak height). A third LED (660/BF) array supplied 98% red light at 660 nm, 1% blue light (BF) between 350 to 550 nm, and 1% far-red light between 700 to 800 nm. Control plants were grown under broad-spectrum metal halide (MH) lamps. Plants were grown at a mean photon flux (300 to 800 nm) of 330 micromoles m-2 s-1 under a 12-h day/night photoperiod. Spectral quality affected each pathosystem differently. In the ToMV/pepper pathosystem, disease symptoms developed slower and were less severe in plants grown under light sources that contained blue and UV-A wavelengths (MH and 660/BF treatments) compared to plants grown under light sources that lacked blue and UV-A wavelengths (660 and 660/735 LED arrays). In contrast, the number of colonies per leaf was highest and the mean colony diameters of S. fuliginea on cucumber plants were largest on leaves grown under the MH lamp (highest amount of blue and UV-A light) and least on leaves grown under the 660 LED array (no blue or UV-A light). The addition of far-red irradiation to the primary light source in the 660/735 LED array increased the colony counts per leaf in the S. fuliginea/cucumber pathosystem compared to the red-only (660) LED array. In the P. solanacearum/tomato pathosystem, disease symptoms were less severe in plants grown under the 660 LED array, but the effects of spectral quality on disease development when other wavelengths were included in the light source (MH-, 660/BF-, and 660/735-grown plants) were equivocal. These results demonstrate that spectral quality may be useful as a component of an integrated pest management program for future space-based controlled ecological life support systems.

NASA Center KSC↗

Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Glancing incidence telescopes for space astronomy

A technique for determining the state of polarization of a light source by evaluating its image at the focus of a glancing telescope is reported. An analysis of the central disc of the diffraction image reveals if the light source is polarized, the plane of polarization, and the degree of polarization. When polarized light is incident at the aperture of a diffraction limited glancing telescope, the central disc of the diffraction pattern takes on an elliptical configuration. This ellipticity is caused by the tendency of the electric vector component in the plane of incidence to be absorbed by the reflecting material. As the state of polarization goes from plane polarized to decreasing degrees of elliptically polarized light, the ellipticity of the central disc goes from a maximum at plane polarization to zero at circular polarization. These curves give a direct relationship between the degree of polarization of a light source and the ellipticity of the central disc for this particular telescope, independent of the light source wavelength.

Alonso, J., Jr.↗

Recent activities of National Synchrotron Light Source-II Insertion Device Group

Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.

47 OTHER INSTRUMENTATION↗

Compact imaging system using a co-linear, high-intensity LED illumination unit to minimize window reflections for background-oriented schlieren, shadowgraph, photogrammetry and machine vision measurements

One aspect of the present disclosure is an imaging system including an optical sensor defining an optical axis. The system further includes a light source. The system may include an optical beam splitter, and may also include an optional diffusing lens that may be configured to diffuse and/or collimate light from the light source and direct light exiting the diffusing lens to the optical beam splitter. The optical beam splitter is configured to direct light from the light source along the optical axis of the optical sensor.

Bathel, Brett F.↗

Synchrotron X-Ray Microprobe and Microspectroscopy Research in Low Temperature Geochemistry

The project focuses on low temperature geochemistry applications of X-ray fluorescence microprobes primarily at the National Synchrotron Light Source (NSLS-I) but also at National Synchrotron Light Source II (NSLS-II), Brookhaven National Laboratory (BNL), Upton, NY. The microprobes can be used to determine the composition, structure, oxidation state, and bonding characteristics of earth materials with trace element sensitivity and micrometer spatial resolution. Investigators on this project are members of the Center for Advanced Radiation Sources (CARS) at the University of Chicago, a team that developed and managed the highly-successful microprobe beamline X26A at the National Synchrotron Light Source I (NSLS-I) at BNL from the 1980s until the closing of NSLS-I in September 2014. The closing of NSLS-I coincided with the start-up of the newly-constructed, 3 rd -generation synchrotron NSLS-II, also at BNL. During the course of this project, a subaward was let to the University of Kentucky to partially support the efforts of a technician at the beamlines.

36 MATERIALS SCIENCE↗

Thumb-actuated two-axis controller

A two axis joystick controller is described. It produces at least one output signal in relation to pivotal displacement of a member with respect to an intersection of the two axes. The member is pivotally movable on a support with respect to the two axes. The support has a centrally disposed aperture. A light source is mounted on the pivotally movable member above the aperture to direct light through the aperture. A light sensor is mounted below the aperture in the support at the intersection of the two axes to receive the light from the light source directed through the aperture. The light sensor produces at least one output signal related to a location on the sensor at which the light from the light source strikes the sensor.

Hollow, R. H.↗

SHARP: a distributed GPU-based ptychographic solver

Ever brighter light sources, fast parallel detectors and advances in phase retrieval methods have made ptychography a practical and popular imaging technique. Compared to previous techniques, ptychography provides superior robustness and resolution at the expense of more advanced and time-consuming data analysis. Therefore, by taking advantage of massively parallel architectures, high-throughput processing can expedite this analysis and provide microscopists with immediate feedback. These advances allow real-time imaging at wavelength-limited resolution, coupled with a large field of view. This article describes a set of algorithmic and computational methodologies used at the Advanced Light Source and US Department of Energy light sources. These are packaged as a CUDA-based software environment named SHARP, aimed at providing state-of-the-art high-throughput ptychography reconstructions for the coming era of diffraction-limited light sources.

47 OTHER INSTRUMENTATION↗