Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam

We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. Here we studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6–10 μm position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.

47 OTHER INSTRUMENTATION↗

Pre-production results from ATLAS ITk Strip Sensors Quality Assurance Testchip

The production of strip sensors within the framework of the ATLAS Inner Tracker (ITk) development is a process which requires continuous evaluation during the full production period (about 4 years). Such an evaluation is divided into two different parts: Quality Control (QC), which focuses on the final product (the actual sensors) and tries to identify possible defects once the fabrication is completed, and Quality Assurance (QA), which aims to prevent deviations in the manufacturing process and uses specifically-designed test structures. The initial sensor pre-production consists of 5% (1041 sensors) of the total number of sensors expected during production. As part of pre-production, the collaboration has measured key parameters from miniature strip sensors (minis), monitor diodes (MD8), and the ATLAS Testchip, before and after irradiation. In this contribution we focus on the analysis of the results of the MD8 and the Testchip. All parameters have been obtained from the test structures (MD8, bias resistors, interdigitated structures, field oxide capacitors, coupling capacitors, punch-through protection structures and cross-bridge resistors) measured at the different test sites (KEK/Tsukuba, Birmingham, Toronto, Ljubljana, Valencia, Carleton, Prague, CNM-Barcelona). The results are compared to predefined pre- and post-irradiation specifications for each tested parameter.

47 OTHER INSTRUMENTATION↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

Enhanced tunable cavity development for axion dark matter searches using a piezoelectric motor in combination with gears

Most search experiments sensitive to quantum chromodynamics (QCD) axion dark matter benefit from microwave cavities, as electromagnetic resonators, that enhance the detectable axion signal power and thus the experimental sensitivity drastically. As the possible axion mass spans multiple orders of magnitude, microwave cavities must be tunable and it is desirable for the cavity to have a tunable frequency range that is as wide as possible. Since the tunable frequency range generally increases as the dimension of the conductor tuning rod increases for a given cylindrical conductor cavity system, we developed a cavity system with a large dimensional tuning rod in order to increase this. Here we, for the first time, employed not only a piezoelectric motor, but also gears to drive a large and accordingly heavy tuning rod, where such a combination to increase driving power can be adopted for extreme environments as is the case for axion dark matter experiments: cryogenic, high-magnetic-field, and high vacuum. Thanks to such higher power derived from the piezoelectric motor and gear combination, we realized a wideband tunable cavity whose frequency range is about 42% of the central resonant frequency of the cavity, without sacrificing the experimental sensitivity too much.

47 OTHER INSTRUMENTATION↗

Preliminary Experiences with the Rexon UL-320-FDR: An Automated Thermoluminescent Dosimeter Reader with Removable Contact Heating Planchets and an Infrared Temperature Feedback System

The Rexon UL-320 FDR is a novel resistive-heating thermoluminescent dosimeter reader with a unique temperature measurement system and an automated dosimeter processing mechanism. The removable contact heating planchets have black-body adhesives on the back for capturing temperature information with infrared sensors. A heating cycle feedback loop ensures accurate, precise, and reproducible heating sequences. Heating rates between 0.8 and 40°C s -1 for up to 1,000 s are possible. Photomultiplier tube sensitivity and drift, dark current counts, and planchet glow were measured experimentally. Additionally, 25 LiF:Mg,Ti dosimeters were calibrated to demonstrate reader performance. Sensitivity was optimized at 1,200 V, which produced the highest reference light count to dark current count ratio while extending photomultiplier tube life. Dark current counts measured with typical time-temperature profiles for LiF:Mg,Ti were below 10 counts per channel but increased by up to 2.5% for more extreme heating cycles. Reader sensitivity drifts of up to 10% were observed during extended automated operations with typical time-temperature profiles. Total counts resulting from planchet glow decreased with faster heating rates. Calibrations performed with LiF:Mg,Ti dosimeters yielded results comparable to more established reader designs. Spikes were observed in ~3% of the glow curves from planchet dust and oil burning off at elevated temperatures. The use of N 2 gas and sensitivity drift corrections are recommended to improve dosimetry performance for the UL-320 FDR reader.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations.

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/ATG.DB1001), the latest update (Agage_gcmd_gcms_data_2021_04_07_tar.gz) includes 6 months of new data through the end of March 2020. Two new compounds, HCFC-132b, and HCFC-133a, are also included in this version. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The Advanced Global Atmospheric Gases Experiment (AGAGE) Data

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/datasets/doi: doi:10.15485/1781803), the latest update (Agage_gcmd_gcms.data.2022_01_03.tar.gz) includes 6 months of new data through the end of September 2020. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the AGAGE and affiliated stations (2022R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments. Data from the AGAGE and affiliated stations (total of 9 sites) between August 1993 and March 2021 are provided in “Agage_gcmd_gcms_data_2022_05_26_tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2022_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the AGAGE and affiliated stations (2022R2)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 9 sites) between August 1993 and December 2021 are provided in “Agage_gcmd_gcms_data_2022_11_15.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2022_v2.pdf". Additional information such as the mission and scientific objectives of the ALE/GAGE/AGAGE program can be found on the AGAGE website (https://agage.mit.edu/about/our-mission).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2023R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and June 2022 are provided in “Agage_gcmd_gcms_data_2023_07_24.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2023_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2023R2)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and December 2022 are provided in “Agage_gcmd_gcms_data_2023_11_15.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2023_v2.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2024R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and June 2023 are provided in “Agage_gcmd_gcms_data_2024_07_11.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2024_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).Update: Dec. 4, 20241. The Cape Grim H2_PDD data are updated in this release ((H2_PDD values in previous release are wrong due to coding error). All other data in this release are the same as previous version ("Agage_gcmd_gcms.data.2024_07_11.tar.gz")2. The latest data are saved in "Agage_gcmd_gcms.data.2024_12_04.tar.gz"

54 ENVIRONMENTAL SCIENCES↗

Detector Related Uncertainties in ICARUS

Neutrinos are hard to study. Cosmic Rays are easier, so they can be used to understand the detector. The ratio of the Monte Carlo simulations and the experimental data gives insights into uncertainties stemming from the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurements with the CMS DAQ and Timing Hub prototype-1

The DAQ and Timing Hub is an ATCA hub board designed for the Phase-2 upgrade of the CMS experiment. In addition to providing high-speed Ethernet connectivity to all back-end boards, it forms the bridge between the sub-detector electronics and the central DAQ, timing, and trigger control systems. One important requirement is the distribution of several high-precision, phase-stable, and LHC synchronous clock signals for use by the timing detectors. The current paper presents first measurements performed on the initial prototype, with a focus on clock quality. It is demonstrated that the current design provides adequate clock quality to satisfy the requirements of the Phase-2 CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Detection System for DUNE Low-Energy Physics Study and the Demonstration of a Timing Resolution of a Few Nanoseconds Using ProtoDUNE-SP PDS

Photon detection systems (PDS) are an integral part of liquid-argon neutrino detectors. Besides providing the timing information for an event, which is necessary for reconstructing the drift coordinates of ionizing particle tracks, photon detectors can be effectively used for other purposes, including triggering events, background rejection, and calorimetric energy estimation. PDS in particular for the DUNE Far Detector Module 2 is designed to achieve a more extended optical coverage (→4 ) with new-generation large-size PD modules based on the ARAPUCA technology. This will provide enhanced opportunities for the study of low-energy neutrino physics using PDS. The ARAPUCA technology was extensively tested within the ProtoDUNE-SP detector operated at the CERN neutrino platform. Here, we present a study of the timing resolution of ARAPUCA detectors using light emitted from a sample of energetic cosmic ray muons traveling parallel to the PDS. An intrinsic timing resolution in the order of 3 ns is observed for the ARAPUCA detectors. The excellent timing resolution ability of PDS can be exploited for further enhancing physics studies using the DUNE far detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗