Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Informative Path Planning for Mapping Radiation

This project involves making measurements of contaminated areas using portable radiation detectors and small robots. Tasks involve operating detectors and small robots, combining data acquisition for the two systems, and automating the systems. The end result is a radiation map of contamination areas. Localization of radioactive sources and mapping of contamination distribution is essential when responding to emergencies, or when dealing with cleanup efforts. Radiation maps are used for situational awareness and for establishing a safe perimeter. However, it may be hazardous or impossible for humans to safely enter the site and survey the area. Informative Path Planning (IPP) is used to design a path for a robotic sensor platform to gather the most information about the radiation distribution while operating under the set of constraints given by the dynamics of the robot and other requirements such as minimizing the overall mission time. The key challenge for IPP is the tight coupling in multiple layers of decisions: Selection of locations to visit; Allocation of sensors to those locations; Processing of information gathered. Given a robot equipped with a basic gamma detector and Lidar sensor, how can we efficiently explore an unknown environment in such a way that we can satisfy the robot's constraints while simultaneously maximizing the accuracy of the map and minimizing the total runtime? This work presents a systematic procedure for IPP and environmental mapping that: Selects the best locations at which to sample; Finds the best path for robots; Estimates the measurement value at unknown locations using a Gaussian Process regression framework. Given a set of points where radiation measurements were taken, we are utilizing a Gaussian Process Regression with a Matern kernel to reconstruct the shape of the underlying ground truth. Mapping is done via the Robot Operating System's OpenSlam Gmapping package, which creates a 2D occupancy grid map. Simulated trials were run with a radiation source placed at random locations, and allowing the robot to select and move towards 20 samples at separate locations, as well as sampling along the path while moving. The simulated sensor model assumed an efficiency of 0.3, collection time of 1 second. Various weighting schemes were tested and compared. Quantitative evaluations often favored exploitation-heavy weighting schemes where μ was emphasized, with the Root Mean Squared Error (RMSE) quickly tending towards 2, whereas qualitative comparisons would favor exploration-biased schemes with greater weight on σ. The difference comes from operators often favoring knowing the general location of a source, rather than the exact properties of a source. Weighting of the path-length π often reduced the quality of the regression as less exploration occurred, however this may be deemed a worthwhile trade-off under certain circumstances, such as with sensitive robots. Successfully developed a methodology for informative path-planning for a robot to efficiently gather information and create a map of radiation. In the future, we would like to focus on: Hardware trials with integration of the robot platform and the IPP software; More refined sensor and environmental modeling; Multiple robot platforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supply Chain-Based Solution to Prevent Fuel Tax Evasion: Final Report

The primary source of funding for the United States transportation system is derived from motor fuel and other highway use taxes. Loss of revenue attributed to fuel-tax evasion has been assessed to be somewhere between 1 billion and 3 billion per year. Any solution that addresses this problem needs to include not only the tax-collection agencies and auditors, but also the carriers transporting oil products and the carriers customers. This report presents a system developed by the Oak Ridge National Laboratory (ORNL) for the Federal Highway Administration which has the potential to reduce or eliminate many fuel-tax evasion schemes. The solution balances the needs of tax-auditors and those of the fuel-hauling companies and their customers. The system has three main components. The on-board subsystem combined sensors, tracking and communication devices, and software (the on-board Evidential Reasoning System, or obERS) to detect, monitor, and geo-locate the transfer of fuel among different locations. The back office sub-system (boERS) used self-learning algorithms to determine the legitimacy of the fuel loading and offloading (important for tax auditors) and detect potential illicit operations such as fuel theft (important for carriers and their customers, and may justify the deployment costs). The third sub-system, the Fuel Distribution and Auditing System or FDAS, is a centralized database, which together with a user interface allows tax auditors to query the data submitted by the fuel-hauling companies and correlate different parameters to quickly identify any anomalies. Industry partners included Barger Transport of Weber City, Virginia (fleet); Air-Weigh, of Eugene, Oregon (and their wires and harnesses); Liquid Bulk Tank (LBT) of Omaha, Nebraska (three five-compartment trailers); and Innovative Software Engineering (ISE) of Coralville, Iowa(on-board telematics device and back-office system). ORNL conducted a pilot test with the three instrumented vehicles collecting real-world data during an eight-month period (October 2014 to June 2015). The vehicles logged a total of 375,000 miles and transported more than 7.5 million gallons of fuel. The drivers entered information on the telematics device about 77% of the time, with about 15% (10%) of the data showing at least one compartment with loading (offloading) valve activity, but not driver information entry for that compartment. Seven events (or about 0.7% of the trips) were identified by the boERS as having a missing fuel diversion number. The solution developed and tested in the pilot test had federal- and state-level tax auditors as its main audience. Nonetheless, the technology has to be adopted by the fuel carriers and therefore the solution had to address the needs of fuel-hauling companies and their customers (i.e., fuel theft and cocktailing). Sensors in the hatches allowed the obERS recognize when one of those were opened (always a suspicious activity, unless it happens at locations where maintenance is performed on the vehicle). The fuel-theft issue was addressed by a self-learning algorithm deployed on the boERS that continuously processed the data from the field to construct probability distributions of measures such as elapsed time of fuel loading and offloading by driver, vehicle, and compartment, valve actuation sequence, elapsed time between the first two valve actuations (by driver, compartment, and location), and other parameters. Probability thresholds, which can be set up by the carrier, determined how to classify the observed events. The boERS also kept track of valve sequencing at a given location and analyzed these actuations to help identify any suspicious activities. Technical and economic recommendations include: a) simplification of the driver data-entry task; b) reduction of system deployment cost; c) addition of capabilities that make the system more appealing to industry (i.e., identify and avoid fuel misdelivery); and d) incorporation of additional capabilities to the FDAS. Path to commercialization recommendations include: a) identify a company willing to further develop, test, and certify a hardened system with a price point the market will bear; b).transfer ERS to licensee; c) establish a fleet or fleets who want this technology for carrier benefits or trailer manufacturer who wants to offer it as optional technology; and d) identify a location for the deployment of FDAS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Maps of the Magellanic clouds from combined South Pole Telescope and Planck data

Here, we present maps of the Large and Small Magellanic Clouds from combined South Pole Telescope (SPT) and Planck data. Both instruments are designed to make measurements of the cosmic microwave background but are sensitive to any source of millimeter-wave (mm-wave) emission. The Planck satellite observes in nine mm-wave bands, while the SPT data used in this work were taken with the three-band SPT-SZ camera. The SPT-SZ bands correspond closely to three of the nine Planck bands, namely those centered at 1.4, 2.1, and 3.0 mm. The angular resolution of the Planck data in these bands ranges from 5 to 10 arcmin, while the SPT resolution in these bands ranges from 1.0 to 1.7 arcmin. The combined maps take advantage of the high resolution of the SPT data and the long-timescale stability of the space-based Planck observations to deliver high signal-to-noise and robust brightness measurements on scales from the size of the maps down to ~1 arcmin. In each of the three bands, we first calibrate and color-correct the SPT data to match the Planck data, then we use noise estimates from each instrument and knowledge of each instrument's beam, or point-spread function, to make the inverse-variance-weighted combination of the two instruments' data as a function of angular scale. Furthermore, we create maps assuming a range of underlying emission spectra (for the color correction) and at a range of final resolutions. We perform several consistency tests on the combined maps and estimate the expected noise in measurements of features in the maps. Finally, we compare the maps of the Large Magellanic Cloud (LMC) from this work to maps from the Herschel HERITAGE survey, finding general consistency between the datasets. Furthermore, the broad wavelength coverage provides evidence of different emission mechanisms at work in different environments in the LMC.

79 ASTRONOMY AND ASTROPHYSICS↗

Advancing a Framework to Enable Characterization and Evaluation of Data Streams Useful for Biosurveillance

In recent years, biosurveillance has become the buzzword under which a diverse set of ideas and activities regarding detecting and mitigating biological threats are incorporated depending on context and perspective. Increasingly, biosurveillance practice has become global and interdisciplinary, requiring information and resources across public health, One Health, and biothreat domains. Even within the scope of infectious disease surveillance, multiple systems, data sources, and tools are used with varying and often unknown effectiveness. Evaluating the impact and utility of state-of-the-art biosurveillance is, in part, confounded by the complexity of the systems and the information derived from them. We present a novel approach conceptualizing biosurveillance from the perspective of the fundamental data streams that have been or could be used for biosurveillance and to systematically structure a framework that can be universally applicable for use in evaluating and understanding a wide range of biosurveillance activities. Moreover, the Biosurveillance Data Stream Framework and associated definitions are proposed as a starting point to facilitate the development of a standardized lexicon for biosurveillance and characterization of currently used and newly emerging data streams. Criteria for building the data stream framework were developed from an examination of the literature, analysis of information on operational infectious disease biosurveillance systems, and consultation with experts in the area of biosurveillance. To demonstrate utility, the framework and definitions were used as the basis for a schema of a relational database for biosurveillance resources and in the development and use of a decision support tool for data stream evaluation.

47 OTHER INSTRUMENTATION↗

A photostationary state analysis of the NO2-NO system based on airborne observations from the subtropical/tropical North and South Atlantic

The Chemical Instrumentation Test and Evaluation 3 (CITE 3) NO-NO2 database has provided a unique opportunity to examine important aspects of tropospheric photochemistry as related to the rapid cycling between NO and NO2. Our results suggest that when quantitative testing of this photochemical system is based on airborne field data, extra precautions may need to be taken in the analysis. This was particularly true in the CITE 3 data analysis where different regional environments produced quite different results when evaluating the photochemical test ratio (NO2)(sub expt)/(NO2)(sub calc), designated here as R(sub E)/R(sub C). The quantity (NO2)(sub Calc) was evaluated using the following photostationary state expression: (NO2)(sub Calc) = k(sub 1)(O3) + k(sub 4)(HO2) + k(sub 5)(CH3O2) + k(sub 6)(RO2))(NO)(sub Expt)/J(sub 2). The four most prominent regional environmental data sets identified in this analysis were those labeled here as free-tropospheric northern hemisphere (FTNH), free-tropospheric tropical northern hemisphere (FTTNH), free-tropospheric southern hemisphere (FTSH), and tropical-marine boundary layer (plume) (TMBL(P)). The respective R(sub E)/R(sub C) mean and median values for these four data subsets were 1.74, 1.69; 3.00, 2.79; 1.01, 0.97; and 0.99, 0.94. Of the four data subsets listed, the two that were statistically the most robust were FTNH and FTSH; for these the respective R(sub E)/R(sub C) mean and standard deviation of the mean values were 1.74 +/- 0.07 and 1.01 +/- 0.04. The FTSH observations were in good agreement with theory, whereas those from the FTNH data set were in significant disagreement. An examination of the critical photochemical parameters O3, UV(zenith), NO, NO2, and non-methane hydrocarbons (NMHCs) for these two databases indicated that the most likely source of the R(sub E)/R(sub C) bias in the FTNH results was the presence of a systematic error in the observational data rather than a shortening in our understanding of fundamental photochemical processes. Although neither a chemical nor meteorological analyses of these data identified this error with complete certainty, they did point to the three most likely possibilities: (1) an NO2 interference from a yet unidentified NO(y) species: (2) the presence of unmeasured hydrocarbons, the integrated reactivity of which would be equivalent to approximately 2.7 parts per billion by volume (ppbv) of toluene; or (3) some combination of points (1) and (2). Details concerning hypotheses (1) and (2) as well as possible ways to minimize these problems in future airborne missions are discussed.

Davis, D. D.↗

Remote Sensing and Geology of Glass Buttes, Oregon

This data set includes Light Detection and Ranging (LiDAR) data, a remote sensing processing report, and a geologic map of the Glass Buttes study area for ORMAT. The total area flown for the LiDAR remote sensing was 86,631 acres to fully encompass the area of interest (84,849 acres). The "LiDAR Remote Sensing Report" reflects statistics for the overall LiDAR survey. An airborne hyperspectral scanner imagery survey over an area in Glass Buttes, Oregon. The "HyMap Survey Processing Report" describes the processing that has been applied to the HyMap data to produce a number of image products including overview colour composites, decorrelation colour composites, minimum noise fraction (MNF) colour composites, and unmixed end-member mineral map. To produce these products the data first has various processes applied to it that converts the raw data into reflectance imagery which is then geometrically corrected and radiometrically leveled so that seamless image mosaics are produced. A detailed geologic map with cross sections of the Glass Buttes Volcanic Complex, Oregon is also included.

15 GEOTHERMAL ENERGY↗

Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic measurements during hardware motion and contact. While performing dynamic testing of an active docking system, researchers found that the data from the motion platform, test hardware and two external measurement systems exhibited frame offsets and rotational errors. While the errors were relatively small when considering the motion scale overall, they substantially exceeded the individual accuracies for each component. After evaluating both the static and dynamic measurements, researchers found that the static measurements introduced significantly more error into the system than the dynamic measurements even though, in theory, the static measurement errors should be smaller than the dynamic. In several cases, the magnitude of the errors varied widely for the static measurements. Upon further investigation, researchers found the larger errors to be a consequence of hardware alignment issues, frame location and measurement technique whereas the smaller errors were dependent on the number of measurement points. This paper details and quantifies the individual and cumulative errors of the docking system and describes methods for reducing the overall measurement error. The overall quality of the dynamic docking tests for flight hardware verification was improved by implementing these error reductions.

Winnitoy, Susan↗

SU-E-T-54: A New Method for Optimizing Radiation Isocenter for Linac-Based SRS

Purpose: To develop a new method to minimize deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter for all combinations of gantry and table angle. Methods: A set of ball-bearing (Winston-Lutz) images was used to determine the gantry radiation isocenter as the midrange of deviation values. Deviations in the cross-plane direction were minimized by calibration of MLC leaf position offset, and by adjusting beam position steering for each energy. Special attention was also paid to matching the absolute position of isocenter across all energies by adjusting position steering in the gun-target axis. Displacement of table axis from the gantry isocenter, and recommended table axis adjustment for contemporary Elekta linacs, was also determined. Eight images were used to characterize the volumetric isocenter for the full range of gantry and table rotations available. Tabulation of deviation for each beam was used to test compliance with isocenter tolerance. Results: Four contemporary Elekta linacs were evaluated and the radius in the gun-target axis of the radiation isocenter was 0.5 to 0.7 mm. After beam steering adjustment, the radius in the cross-plane direction was typically 0.2 to 0.4 mm. Position matching between energies can be reduced to 0.28 mm. Maximum total deviation was 0.68 to 1.07 mm, depending primarily on the effect of systematic table axis wobble with rotation. Conclusion: This new method effectively facilitates minimization of deviation between beam center and target position. The test, which requires a few minutes to perform, can be easily incorporated into a routine machine QA program. A tighter radiation isocenter for contemporary Elekta linacs would require reducing the effect of gantry arm flex and/or table axis wobble that are the two main components of deviation from the designated isocenter point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distillation Column Flooding Predictor

The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid/vapor traffic that produce increased contact area and lead to substantial increases in separation efficiency – which translates to a 10% increase in energy efficiency on a BTU/bbl basis. The Flooding Predictor™ operates on the principle that between five to sixty minutes in advance of a flooding event, certain column variables experience an oscillation, a pre-flood pattern. The pattern recognition system of the Flooding Predictor™ utilizes the mathematical first derivative of certain column variables to identify the column’s pre-flood pattern(s). This pattern is a very brief, highly repeatable, simultaneous movement among the derivative values of certain column variables. While all column variables experience negligible random noise generated from the natural frequency of the process, subtle pre-flood patterns are revealed among sub-sets of the derivative values of column variables as the column approaches its hydraulic limit. The sub-set of column variables that comprise the pre-flood pattern is identified empirically through in a two-step process. First, 2ndpoint’s proprietary off-line analysis tool is used to mine historical data for pre-flood patterns. Second, the column is flood-tested to fine-tune the pattern recognition for commissioning. Then the Flooding Predictor™ is implemented as closed-loop advanced control strategy on the plant’s distributed control system (DCS), thus automating control of the column at its hydraulic limit.

02 PETROLEUM↗

Search for Pauli exclusion principle violating atomic transitions and electron decay with a p-type point contact germanium detector

Here, a search for Pauli-exclusion-principle-violating K α electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8 × 10 30 s at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the X-ray and Auger electrons present following the transition. A similar analysis was done to look for the decay of atomic K-shell electrons into neutrinos, resulting in a lower limit of 6.8 × 10 30 s at 90% C.L. It is estimated that the Majorana Demonstrator, a 44 kg array of p-type point contact detectors that will search for the neutrinoless double-beta decay of 76 Ge, could improve upon these exclusion limits by an order of magnitude after three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-406: Use of TrueBeam Developer Mode and API to Increase the Efficiency and Accuracy of Commissioning Measurements for the Varian EDGE Stereotactic Linac

Purpose: The Varian EDGE machine is a new stereotactic platform, combining Calypso and VisionRT localization systems with a stereotactic linac. The system includes TrueBeam DeveloperMode, making possible the use of XML-scripting for automation of linac-related tasks. This study details the use of DeveloperMode to automate commissioning tasks for Varian EDGE, thereby improving efficiency and measurement consistency. Methods: XML-scripting was used for various commissioning tasks,including couch model verification,beam-scanning,and isocenter verification. For couch measurements, point measurements were acquired for several field sizes (2×2,4×4,10×10cm{sup 2}) at 42 gantry angles for two couch-models. Measurements were acquired with variations in couch position(rails in/out,couch shifted in each of motion axes) compared to treatment planning system(TPS)-calculated values,which were logged automatically through advanced planning interface(API) scripting functionality. For beam scanning, XML-scripts were used to create custom MLC-apertures. For isocenter verification, XML-scripts were used to automate various Winston-Lutz-type tests. Results: For couch measurements, the time required for each set of angles was approximately 9 minutes. Without scripting, each set required approximately 12 minutes. Automated measurements required only one physicist, while manual measurements required at least two physicists to handle linac positions/beams and data recording. MLC apertures were generated outside of the TPS,and with the .xml file format, double-checking without use of TPS/operator console was possible. Similar time efficiency gains were found for isocenter verification measurements Conclusion: The use of XML scripting in TrueBeam DeveloperMode allows for efficient and accurate data acquisition during commissioning. The efficiency improvement is most pronounced for iterative measurements, exemplified by the time savings for couch modeling measurements(approximately 10 hours). The scripting also allowed for creation of the files in advance without requiring access to TPS. The API scripting functionality enabled efficient creation/mining of TPS data. Finally, automation reduces the potential for human error in entering linac values at the machine console,and the script provides a log of measurements acquired for each session. This research was supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opportunistic Short‐Term Water Uptake Dynamics by Subalpine Trees Observed via In Situ Water Isotope Measurements

Abstract Variations in tree water sources are important to understand in semi‐arid ecosystems because climatic shifts towards lower snowpack and increased drought affect water availability in subalpine forests of the western US. Here, we use daily in situ measurements of stable isotopes ( 2 H & 18 O) in soil and tree stem water, soil matric potential and sap flow to study tree water uptake dynamics. We instrumented three soil profiles down to 90 cm, as well as three aspen and engelmann spruce trees near Gothic, Colorado, in the East River watershed. We observed the fate of natural isotopic variations in rainfall, soil, and plants from June to October 2022, and in August 2023 we conducted a 2 H labeled irrigation experiment. Our observations showed that all studied aspen trees compensated for water scarcity in the shallow soil by shifting the dominant water source at 60(±20) cm to ⅔ of uptake from 90 cm within a few days of a dry period. Both species relied on snowmelt stored in the subsoil to sustain transpiration. Intense rainfall caused the plant water uptake to shift partially to top soil layers within 2 days. Spruce transpiration was lower and relied more on snowmelt, because rainfall infiltration was low in the spruce stand due to high canopy interception. Our findings highlight the important role of snowmelt stored in the deep soil layers for subalpine forest drought response and the dominant fate of monsoonal rainfall to become transpiration rather than recharging groundwater and streams in the Upper Colorado River. Plain Language Summary There is a need to understand how trees in mountainous regions respond to dry conditions that lead to water scarcity, because climate projections suggest that such conditions will become more frequent in the future. Here we present a novel data set of measurements of daily stable isotopes of water across soil profiles and in tree stems of aspen and spruce. Our data show that when the upper soil dried out, aspen trees shifted to using water from deeper layers (beneath 60 cm) to keep transpiring. For spruce trees the uptake pattern is less clear, but both types of trees mainly used snowmelt stored in the deeper soil layers to survive the dry summer. After heavy rain, aspen and spruce trees switched to using water from the top 20 cm of soil. However, for spruce, only some rain reached the soil because the dense tree canopy intercepted it, so spruce trees stayed more dependent on snowmelt and used less water overall. This study shows how important deep snowmelt water is for helping forests survive dry periods and suggests that most summer rain is quickly used by trees rather than replenishing streams and groundwater in the headwaters of the Colorado River. Key Points Tree water resources changed within a few days from snow dominated to higher share of rainfall as soils wetted up after a dry period Compensatory plant water uptake by aspen from the deep layer (90 cm), while uptake from soil depths that became drier (60 cm) declined Strong differences between water sources and availability beneath aspen and spruce, respectively

Sprenger, Matthias↗

THE CHANDRA SOURCE CATALOG

The Chandra Source Catalog (CSC) is a general purpose virtual X-ray astrophysics facility that provides access to a carefully selected set of generally useful quantities for individual X-ray sources, and is designed to satisfy the needs of a broad-based group of scientists, including those who may be less familiar with astronomical data analysis in the X-ray regime. The first release of the CSC includes information about 94,676 distinct X-ray sources detected in a subset of public Advanced CCD Imaging Spectrometer imaging observations from roughly the first eight years of the Chandra mission. This release of the catalog includes point and compact sources with observed spatial extents {approx}<30''. The catalog (1) provides access to the best estimates of the X-ray source properties for detected sources, with good scientific fidelity, and directly supports scientific analysis using the individual source data; (2) facilitates analysis of a wide range of statistical properties for classes of X-ray sources; and (3) provides efficient access to calibrated observational data and ancillary data products for individual X-ray sources, so that users can perform detailed further analysis using existing tools. The catalog includes real X-ray sources detected with flux estimates that are at least 3 times their estimated 1{sigma} uncertainties in at least one energy band, while maintaining the number of spurious sources at a level of {approx}<1 false source per field for a 100 ks observation. For each detected source, the CSC provides commonly tabulated quantities, including source position, extent, multi-band fluxes, hardness ratios, and variability statistics, derived from the observations in which the source is detected. In addition to these traditional catalog elements, for each X-ray source the CSC includes an extensive set of file-based data products that can be manipulated interactively, including source images, event lists, light curves, and spectra from each observation in which a source is detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Encealdus Orbilander: A Flagship Mission Concept for Astrobiology

"Whether life exists beyond Earth remains a fundamental question driving our exploration of the Solar System. At Saturn’s moon Enceladus, plumes of oceanic material vented into space allow the investigation of the astrobiological potential of an ocean world, hinted at by Cassini, without the necessity of drilling through kilometers of ice crust. The Enceladus Orbilander is a flagship ($2.56B in fiscal year 2025 dollars) mission concept created for the 2023–2033 Planetary Science Decadal Survey. Orbilander takes full advantage of the opportunity provided by Enceladus’ plumes to search for signs of life. A single spacecraft both orbits and lands, capturing samples from four distinct reservoirs offered by the plumes. These samples, both particulate and vapor, are then analyzed by the Life Detection Suite (LDS), a set of five instruments conducting complementary and orthogonal biosignature-seeking measurements. To provide the context that specifically enhances interpretation of LDS measurements, geochemical and geophysical investigations are conducted both in orbit and on the surface. These reveal the physio-chemical state of the ocean and core as well as the processes involved in ejection of plume material and how these affect the ocean material analyzed by the LDS. The Orbilander can be delivered to the Saturn system via several launch vehicle and trajectory options, including a direct trajectory (7-year cruise), a ∆V-EGA trajectory (9-year cruise) and several options using an inner cruise with Venus and Earth flybys (10-year cruise). Upon Saturn Orbit Insertion, a 4-year moon tour pumps down the Orbilander’s orbit to intercept Enceladus. The most optimal arrival times balance the Jupiter flyby opportunities of the late 2030s and solar illumination at the Enceladus high southern latitudes where plume material is most abundant. This mission concept therefore targets project start in 2030. Upon Enceladus Orbit Insertion, the Orbilander begins a 1.5-year-long campaign of landing site reconnaissance, remote sensing science, and collecting sufficient plume sample to run all but one of the LDS measurements. After successful landing, the Orbilander spends 2 years on the surface conducting multiple LDS measurements with all five instruments on actively and passively collected plume material, as well as seismic investigations. The schedule laid out here is well-defined, but the mission also has operational and resource flexibility should additional reconnaissance be needed. As part of the design study, mission and development risks were identified and mitigation strategies proposed. Technologies key to achieving the life detection science objectives include instrumentation matured under programs like COLDTech and ICEE-2, such as aspects of the sampling system and microfluidic devices, as well as well-known techniques like high-resolution and separation-capable mass spectrometers. Autonomous onboard navigation is planned to maintain a halo orbit around Enceladus to enable passive sampling from orbit as well as reconnaissance measurements for use in site selection and landing. Terrain relative navigation is included to ensure safe landing, given that targeted areas may contain landing hazards. Continued development of radioisotope thermoelectric generator (RTG) technology and long-life batteries is essential for this long duration mission. The Enceladus Orbilander represents an optimal point in the trade space of science value versus cost, taking advantage of the extensive knowledge of Enceladus provided by Cassini, how well Enceladus lends itself to a search for life in material from its ocean, and the flexibility afforded by the innovative design developed by the APL team. By taking full advantage of Enceladus’ plumes both in orbit and on the surface, Orbilander represents a robust search for life with complementary and orthogonal biosignatures as well as contextual geophysical and geochemical measurements, determining not only whether Enceladus is inhabited (at levels up to 500,000× scarcer than in Earth’s oceans) but also why. "

Exobiology↗

SU-E-J-113: The Influence of Optimizing Pediatric CT Simulator Protocols On the Treatment Dose Calculation in Radiotherapy

Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with interval of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Multiplicity Counting Moments for Fissile Mass Estimation in Scatter-Based Neutron Detection Systems

Neutron multiplicity counting (NMC) techniques are widely used for nuclear materials accountability and international safeguards applications to quantitatively evaluate characteristic properties pertaining to fissile material. Mathematical models for NMC moments have been previously derived for systems that use capture-based detectors; however, these models are not applicable when scatter-based detectors are used because of “neutron cross talk.” Neutron cross talk occurs when a single neutron scatters and deposits energy above threshold into multiple detectors causing spurious increase in multiplicity counts; this, in turn, has caused fissile mass to be overestimated when not treated. In this paper, we propose new mathematical models derived from point kinetics to correct for neutron cross-talk effects up to any arbitrary order N, where N denotes the maximum number of counts a single neutron can cause. The new models were used to estimate the fissile mass of plutonium metal and oxide samples with effective 240 Pu mass ranging from 2.5 to 250 g. The adequacy of the models was confirmed using simulations of a conceptual scatter-based neutron multiplicity counter (e.g., organic scintillators) using MCNPX v2.7e with the PoliMi fission event generating extension. The fissile mass estimates with no correction for neutron cross-talk events yielded an average relative deviation from the true 240 Pu eff mass of 55.94% and 84.56% for metal and oxide samples, respectively. When neutron cross-talk events of order N = 2 are included in the model, the fissile mass estimates yielded an average relative deviation of 11.89% for metal and 13.21% for oxide samples. Accounting for neutron cross-talk events of order N = 3 resulted in fissile mass estimates with an average relative deviation of 9.58% and 10.51% for metal and oxide samples, respectively. These mass estimates were compared to a reference case (i.e., no neutron crosstalk effects) that yielded an average relative deviation of 6.81% and 4.77% for metal and oxide samples, respectively. In conclusion, the discrepancy between the estimates from the proposed model and the reference case is attributed to the assumed value of N, which sets a finite upper bound on the order of cross-talk events the model treats (i.e., the model for N = 3 assumes that a neutron will never cause more than three counts).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HarDWR - Harmonized Water Rights Records

For a detailed description of the database of which this record is only one part, please see the HarDWR meta-record. Here we present a new dataset of western U.S. water rights records. This dataset provides consistent unique identifiers for each spatial unit of water management across the domain, unique identifiers for each water right record, and a consistent categorization scheme that puts each water right record into one of 7 broad use categories. These data were instrumental in conducting a study of the multi-sector dynamics of intersectoral water allocation changes through water markets (Grogan et al., in review). Specifically, the data were formatted for use as input to a process-based hydrologic model, WBM, with a water rights module (Grogan et al., in review). While this specific study motivated the development of the database presented here, U.S. west water management is a rich area of study (e.g., Anderson and Woosly, 2005; Tidwell, 2014; Null and Prudencio, 2016; Carney et al, 2021) so releasing this database publicly with documentation and usage notes will enable other researchers to do further work on water management in the U.S. west. The raw downloaded data for each state is described in Lisk et al. (in review), as well as here. The dataset is a series of various files organized by state sub-directories. The first two characters of each file name is the abbreviation for the state the in which the file contains data for. After the abbreviation is the text which describes the contents of the file. Here is each file type described in detail: XXFullHarmonizedRights.csv: A file of the combined groundwater and surface water records for each state. Essentially, this file is the merging of XXGroundwaterHarmonizedRights.csv and XXSurfaceWaterHarmonizedRights.csv by state. The column headers for each of this type of file are: state - The name of the state the data comes from. FIPS - The two digit numeric state ID code. waterRightID - The unique identifying ID of the water right, the same identifier as its state uses. priorityDate - The priority date associated with the right. origWaterUse - The original stated water use from the state. waterUse - The water use category under the unified use categories established here. source - Whether the right is for surface water or groundwater. basinNum - The alpha-numeric identifier of the WMA the record belongs to. CFS - The maximum flow of the allocation in cubic feet per second (ft3s-1). Arizona is unique among the states, as its surface and groundwater resources are managed with two different sets of boundaries. So, for Arizona, the basinNum column is missing and instead there are two columns: surBasinNum - The alpha-numeric identifier of the surface water WMA the record belongs to. grdBasinNum - The alpha-numeric identifier of the groundwater WMA the record belongs to. XXStatePOD.shp: A shapefile which identifies the location of the Points of Diversion for the state's water rights. It should be noted that not all water right records in XXFullHarmonizedRights.csv have coordinates, and therefore may be missing from this file. XXStatePOU.shp: A shapefile which contains the area(s) in which each water right is claimed to be used. Currently, only Idaho and Washington provided valid data to included within this file. XXGroundwaterHarmonizedRights.csv: A file which contains only harmonized groundwater rights collected from each state. See XXFullHarmonizedRights.csv for more details on how the data is formatted. XXSurfaceWaterHarmonizedRights.csv: A file which contains only harmonized surface water rights collected from each state. See XXFullHarmonizedRights.csv for more details on how the data is formatted. Additionally, one file, stateWMALabels.csv, is not stored within a sub-directory. While we have referred to the spatial boundaries that each state uses to manage its water resources as WMAs, this term is not shared across all states. This file lists the proper name for each boundary set, by state.

Economics↗