Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Microreactor Program Technology Maturation MACS system reports

This submission contains several reports associated with the DOE Microreactor Program Technology Maturation MACS system. These include milestone reports: M3AT-24IN0804031-Optimized MACS architecture M3AT-24IN0804033-Light and temp sensor integration M4AT-23IN0804055-Update Microreactor Automated Control System (MACS) hardware based on input from demonstration M2AT-23IN0804054-Demonstrate actuation of control system using Microreactor Automated Control System (MACS)

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

BEACON—automated aberration correction for scanning transmission electron microscopy using Bayesian optimization

Aberration correction is an important aspect of modern high-resolution scanning transmission electron microscopy. Most methods of aligning aberration correctors require specialized sample regions and are unsuitable for fine-tuning aberrations without interrupting on-going experiments. Here, we present an automated method of correcting first- and second-order aberrations called BEACON, which uses Bayesian optimization of the normalized image variance to efficiently determine the optimal corrector settings. We demonstrate its use on gold nanoparticles and a hafnium dioxide thin film showing its versatility in nano- and atomic-scale experiments. BEACON can correct all first- and second-order aberrations simultaneously to achieve an initial alignment and first- and second-order aberrations independently for fine alignment. Ptychographic reconstructions are used to demonstrate an improvement in probe shape and a reduction in the target aberration.

techniques and instrumentation↗

Spatio-temporal evolution of femtosecond laser pulses in dielectric multi-layers controlling the damage behavior

When designing femtosecond laser mirrors, one tries to minimize the peak intensity within the high-index layers to increase the laser-induced damage threshold. Typically, the optimization procedure utilizes the electric field distribution in the layer stack generated by monochromatic irradiation. Furthermore, this approach is sufficient for certain structures like high-reflectors based on quarter-wave films. More complex structures require to take into account the exact evolution of the pulse parameters such as peak intensity and duration within the multi-layer system. We exemplify this by discussing a merit function that can be included in femtosecond optics design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iterative wavefront optimization of ultrafast laser beams carrying orbital angular momentum

Structured intense laser beams offer degrees of freedom that are highly attractive for high-field science applications. However, the performance of high-power laser beams in these applications is often hindered by deviations from the desired spatiotemporal profile. This study reports the wavefront optimization of ultrafast Laguerre-Gaussian beams through the synergy of adaptive optics and genetic algorithm-guided feedback. The results indicate that the intensity fluctuations along the perimeter of the target ring-shaped profile can be reduced up to ~15%. Furthermore, the radius of the ring beam profile can be tailored to a certain extent by establishing threshold fitting criteria. The versatility of this approach is experimentally demonstrated in conjunction with different focusing geometries.

47 OTHER INSTRUMENTATION↗

Unsupervised Process Anomaly Detection and Identification Using the Leave-One-Variable-Out Approach

Automated anomaly detection and identification can signal equipment issues and pinpoint causes in large-scale industrial systems. For systems with limited failure history, unsupervised machine learning methods can be utilized as they do not require past failures. This study introduces the leave-one-variable-out (LOVO) model, which masks one variable at a time to predict the others, learning underlying process correlations. Detection performance was assessed with synthetic and experimental data, while identification performance used only synthetic data due to its ability to generate labeled anomaly types. For detection using synthetic data, the LOVO model generally outperformed comparative models; while using experimental data, the comparative methods outperformed the LOVO model. However, the comparative methods required selecting a latent size, and these conclusions pertain to using the optimal size. In practice, it would not be feasible to always select the optimal value, and incorrect selections impacted performance. In contrast, the LOVO model does not require a latent space. For identification using synthetic data, the LOVO model was slightly outperformed in interpretability and repeatability but still demonstrated impressive results. These outcomes suggest that the LOVO model is an effective model and may be more easily implemented without the challenging tuning process of selecting a latent size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonuclear Production of Radioxenon for Air Samples

Radioxenon plays an important role in ensuring compliance with the Comprehensive Nuclear-Test-Ban Treaty due to its ability to be transported through the atmosphere, as well as the fact that the half-lives of its isotopes provide a window long enough to be detected but not long enough that it could become background radiation. This allows it to be correlated with specific events that indicate the testing of nuclear weapons. Idaho National Laboratory supports this mission by providing spiked air samples for monitoring stations to enable instrument calibration and ensure measurement accuracy. We tested a photonuclear method of producing one of the main isotopes of radioxenon, Xe-135. We also tested the separation of Xe-135 from the parent isotope Xe-136 using the method of kinematic recoil. Aluminum coils were placed in quartz ampoules filled with enriched Xe-136 and were irradiated by a bremsstrahlung beam with an endpoint energy of 21 MeV. The results showed that we were not only successful in producing Xe-135 but also that the Xe-135 was deposited into the coil allowing it to be removed from the Xe-136 gas. The coil and the Xe-135 can then be chemically separated. At the time of counting the coil, it was calculated that there was about 18 Bq of activity from Xe-135 remaining in the coil. Future work includes determining the optimal material and geometry of the catcher to maximize the amount of Xe-135 captured.

07 ISOTOPE AND RADIATION SOURCES↗

Rare earth element separations by high-speed counter-current chromatography

We report that following the initial development of High-Speed Counter-Current Chromatography (HSCCC) in the 1960s, several studies have explored its applicability in the separation of rare earth elements (REEs). More recently, however, HSCCC publications have transitioned towards the separation of natural products or pharmaceuticals, leaving the application for REEs largely unexplored from a practical standpoint. Herein, we expand upon prior work in this field by evaluating the suitability of HSCCC to separation of a subset of non-radioactive REEs (Nd, Sm, Eu, Tb, and Y) at 10 -4 mol levels using di-(2-ethylhexyl)phosphoric acid (HDEHP) in n-heptane as the stationary phase and hydrochloric acid as the mobile phase. First, the effect of flow rate on the stationary phase volume retention ratio and resolution of Nd/Sm/Eu subgroup was evaluated followed by optimization of step-gradient elution profiles resulting in additional recovery of Tb and Y within a seven-hour window. The five REEs were separated at the baseline resolution level or above. Elution profiles obtained from multiple runs across two independently operated columns and across independent runs were cross analyzed. Reproducibility in elution profiles point to future applications in radioelement separation chemistry, where both chemical and radiochemical purity are of importance.

47 OTHER INSTRUMENTATION↗

Linewidth narrowing in self-injection-locked on-chip lasers

Abstract Stable laser emission with narrow linewidth is of critical importance in many applications, including coherent communications, LIDAR, and remote sensing. In this work, the physics underlying spectral narrowing of self-injection-locked on-chip lasers to Hz-level lasing linewidth is investigated using a composite-cavity structure. Heterogeneously integrated III–V/SiN lasers operating with quantum-dot and quantum-well active regions are analyzed with a focus on the effects of carrier quantum confinement. The intrinsic differences are associated with gain saturation and carrier-induced refractive index, which are directly connected with 0- and 2-dimensional carrier densities of states. Results from parametric studies are presented for tradeoffs involved with tailoring the linewidth, output power, and injection current for different device configurations. Though both quantum-well and quantum-dot devices show similar linewidth-narrowing capabilities, the former emits at a higher optical power in the self-injection-locked state, while the latter is more energy-efficient. Lastly, a multi-objective optimization analysis is provided to optimize the operation and design parameters. For the quantum-well laser, minimizing the number of quantum-well layers is found to decrease the threshold current without significantly reducing the output power. For the quantum-dot laser, increasing the quantum-dot layers or density in each layer increases the output power without significantly increasing the threshold current. These findings serve to guide more detailed parametric studies to produce timely results for engineering design.

47 OTHER INSTRUMENTATION↗

A stretchable and strain-unperturbed pressure sensor for motion interference–free tactile monitoring on skins

A stretchable pressure sensor is a necessary tool for perceiving physical interactions that take place on soft/deformable skins present in human bodies, prosthetic limbs, or soft robots. However, all existing types of stretchable pressure sensors have an inherent limitation, which is the interference of stretching with pressure sensing accuracy. Here, we present a design for a highly stretchable and highly sensitive pressure sensor that can provide unaltered sensing performance under stretching, which is realized through the synergistic creations of an ionic capacitive sensing mechanism and a mechanically hierarchical microstructure. Via this optimized structure, our sensor exhibits 98% strain insensitivity up to 50% strain and a low pressure detection limit of 0.2 Pa. With the capability to provide all the desired characteristics for quantitative pressure sensing on a deformable surface, this sensor has been used to realize the accurate sensation of physical interactions on human or soft robotic skin.

47 OTHER INSTRUMENTATION↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

The Manufacturing Data and Machine Learning Platform: Enabling Real-time Monitoring and Control of Scientific Experiments via IoT

IoT devices and sensor networks present new opportunities for measuring, monitoring, and guiding scientific experiments. Sensors, cameras, and instruments can be combined to provide previously unachievable insights into the state of ongoing experiments. However, IoT devices can vary greatly in the type, volume, and velocity of data they generate, making it challenging to fully realize this potential. Indeed, synergizing diverse IoT data streams in near-real time can require the use of machine learning (ML). In addition, new tools and technologies are required to facilitate the collection, aggregation, and manipulation of sensor data in order to simplify the application of ML models and in turn, fully realize the utility of IoT devices in laboratories. Here we will demonstrate how the use of the Argonne-developed Manufacturing Data and Machine Learning (MDML) platform can analyze and use IoT devices in a manufacturing experiment. MDML is designed to standardize the research and operational environment for advanced data analytics and AI-enabled automated process optimization by providing the infrastructure to integrate AI in cyber-physical systems for in situ analysis. We will show that MDML is capable of processing diverse IoT data streams, using multiple computing resources, and integrating ML models to guide an experiment.

Machine Learning↗

Isotopic analysis of plutonium measured with very thick absorbers and high-granularity spectra

FRAM is LANL-designed software designed to extract plutonium and uranium isotopic information from gamma ray spectra. This is an important capability for NEST and STAB; however, FRAM performance has been poor when applied to field data collected in these programs. FRAM Version 5 (commercially available) was fine-tuned and validated for laboratory quality measurements but not for measurements of the high-mass and heavily shielded SNM items encountered in NEST. FRAM is untested for spectra collected with high-granularity lower resolution instruments such as the new 8-MeV Detective-X favored by STAB or the new custom electrocooled systems coming into use for NEST. FRAM Version 6.1 (unreleased) has improvements in physics capabilities, and parameter sets may be adapted that are more specific to NEST and STAB, which is what we have attempted for this assignment. Thick shielding attenuates gamma rays profoundly, especially those at low energy, making them too weak to be measured. The missing low-energy peaks force the analysis to employ only the highest-energy peaks. We adapted FRAM 6.1 for analysis of plutonium spectra obtained with very thick Pb filters (a surrogate for NEST-type configurations). New parameter sets employing only very high energy peaks were created for the analysis. High granularity and low resolution make deconvolution of the 600-keV region particularly challenging, and we have worked to optimally extract information from this region. The results shown in this paper give high confidence that we are on the right track. We used a combination of real and synthetically-modified data. Remaining work includes testing the new software and parameters against genuine data collected with Detective-X and new NEST systems, but such datasets at the moment are unavailable. It also remains to develop and test parameter sets specific to uranium and the new detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a bi-solvent liquid scintillator with slow light emission

One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid scintillator chemistry. The development of a potentially suitable future detector liquid with particularly slow light emission is discussed in the present publication. This cocktail is compared with respect to its fundamental characteristics (scintillation efficiency, transparency, and time profile of light emission) with liquid scintillators currently used in large-scale neutrino detectors. In addition, the optimization of the admixture of wavelength shifters for a scintillator with particularly high light emission is presented. Furthermore, the pulse-shape discrimination capabilities of the novel medium was studied using a pulsed particle accelerator driven neutron source. Beyond that, purification methods based on column chromatography and fractional vacuum distillation for the co-solvent DIN (Diisopropylnaphthalene) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2020 Transportation Research Board Workshop: Infrastructure Spatial Sensing at Intersections: The Potential to Enhance Safety and Enable Automation

The sensing technology that is enabling vehicle automation also can revolutionize traffic intersection safety, control, and efficiency. Infrastructure spatial sensing technology refers to the deployment of sensors that can detect and track all objects in the field of view - for example, mounting lidar sensors, radar, and video imaging at an intersection and fusing the data to produce a three-dimensional dynamic operational awareness. Combining such sensing capability with fail-safe vehicle communications can facilitate applications such as eco-approach and departure, optimizing efficient vehicle-signal coordination, and reducing traffic accidents through increasing safety. Furthermore, evidence is mounting suggesting that infrastructure-based sensing is needed in order to safely deploy automated public mobility alongside the normal vehicle and pedestrian traffic in our cities. Six speakers were invited to present their work from various aspects (safety, efficiency, and automation) addressing infrastructure-based sensing at the workshop on Infrastructure Spatial Sensing hosted in Washington DC as part of the Transportation Research Board Annual Meeting in January 12, 2019. A summary of the presentation are included herein.

47 OTHER INSTRUMENTATION↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗