Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Ion Exchange Temperature Testing with SRF Resin

Ion exchange using the Spherical Resorcinol-Formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection for use in the Pretreatment Facility of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in an at-tank deployment for removing 137Cs. Recent proposed changes to the WTP ion exchange process baseline indicate that higher temperatures (50°C) to alleviate post-filtration precipitation issues prior to reaching the ion exchange columns may be required. Therefore, it is important to understand the behavior of SRF resin performance under the conditions expected with the new equipment and process changes. This research examined the impact of elevated temperature on resin loading and resin degradation during extended solution flow using elevated temperature (45°, 50°, 55°, 60°, 65°, 75°C). Testing for extended times at elevated temperatures showed that the resin does degrade and loading capacity is reduced at and above 45°C. Above 60°C the resin appears to not load at all.

Hanford Tank Waste Treatment and Immobilization Pl↗

Role of Design Standards in Wind Plant Optimization (Presentation)

When a turbine is optimized, it is done within the design constraints established by the objective criteria in the international design standards used to certify a design. Since these criteria are multifaceted, it is a challenging task to conduct the optimization, but it can be done. The optimization is facilitated by the fact that a standard turbine model is subjected to standard inflow conditions that are well characterized in the standard. Examples of applying these conditions to rotor optimization are examined. In other cases, an innovation may provide substantial improvement in one area, but be challenged to impact all of the myriad design load cases. When a turbine is placed in a wind plant, the challenge is magnified. Typical design practice optimizes the turbine for stand-alone operation, and then runs a check on the actual site conditions, including wakes from all nearby turbines. Thus, each turbine in a plant has unique inflow conditions. The possibility of creating objective and consistent inflow conditions for turbines within a plant, for used in optimization of the turbine and the plant, are examined with examples taken from LES simulation.

17 WIND ENERGY↗

Risk-Informed Safety Margin Characterization Case Study: Selection of Electrical Equipment to Be Subjected to Environmental Qualification

The Risk-Informed Safety Margin Characterization (RISMC) pathway of the DOE’s Light Water Reactor Sustainability (LWRS) program focuses on advancing the state of the art in safety analysis and risk assessment to support decision-making on nuclear power plant operation well beyond the originally designed lifetime of the plants (i.e., beyond 60 years). Among the issues being addressed in RISMC is the significance of SSC aging and how confident we are about our understanding of its impact on the margin between the loads SSCs are expected to see during normal operation and accident conditions, and the SSC capacities (their ability to resist those loads) as the SSCs age. In this paper, a summary is provided of a case study that examines SSC aging from an environmental qualification (EQ) perspective. The case study illustrates how the state of knowledge regarding SSC margin can be characterized given the overall integrated plant design, and was developed to demonstrate a method for deciding on which cables to focus, which cables are not so important from an environmental qualification margin standpoint, and what plant design features or operating characteristics determine the role that environmental qualification plays in establishing a safety case on which decisions regarding margin can be made. The selection of cables for which demonstration of margin with respect to aging and environmental challenges uses a technique known as Prevention Analysis. Prevention Analysis is a Boolean method for optimal selection of SSCs (that is, those combinations of SSCs both necessary and sufficient to meet a predetermined selection criterion) in a manner that allows demonstration that plant-level safety can be demonstrated by the collection of selected SSCs alone. Choosing the set of SSCs that is necessary and sufficient to satisfy the safety objectives, and demonstrating that the safety objectives can be met effectively, determines where resources are best allocated to assure SSC performance margin. The paper describes the resulting component types that were selected by Prevention Analysis and identifies the accident sequence characteristics that cause these component types to be important from an EQ and aging perspective (and, hence, worthwhile evaluating the extent of safety margin). In addition, component types not selected as needing significant margin from an EQ and aging perspective are discussed and an engineering rationale is developed justifying the lack of need to apply resources to demonstrating margin for these component types. This rationale is in terms of design features of the plant and operating characteristics that make these component types less important from an EQ and aging perspective. While the case study focuses on EQ and aging of equipment and cables located inside the containment of this PWR, the prevention analysis method is demonstrated to be an effective technique for identification of minimal collections of components that would be effective in managing safety for a variety of issues associated with aging and long-term operation of the fleet of plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Distributed Wind Aeroelastic Modeling (dWAM)

Aeroelastic modeling is the primary method for the structural and performance assessment of any wind turbine. These tools provide an understanding of the impact of design parameters on turbine loading and power response before operating in the field. Despite these advantages, the use of aeroelastic modeling in the distributed wind energy industry is limited. This project aims to improve the aeroelastic modeling tools for distributed wind turbines to enable the design and certification of optimized turbine technology with a competitive cost of energy.

aeroelastic modeling tools↗

Ion Exchange Temperature Testing with SRF Resin - 12088

Ion exchange using the Spherical Resorcinol-Formaldehyde (SRF) resin has been selected by the U.S. Department of Energy's Office of River Protection for use in the Pretreatment Facility of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in an at-tank deployment for removing Cs-137. Recent proposed changes to the WTP ion exchange process baseline indicate that higher temperatures (50 deg. C) to alleviate post-filtration precipitation issues prior to reaching the ion exchange columns may be required. Therefore, it is important to understand the behavior of SRF resin performance under the conditions expected with the new equipment and process changes. This research examined the impact of elevated temperature on resin loading and resin degradation during extended solution flow at elevated temperature (45 deg., 50 deg., 55 deg., 60 deg., 65 deg., 75 deg. C). Testing for extended times at elevated temperatures showed that the resin does degrade and loading capacity is reduced at and above 45 deg. C. Above 60 deg. C the resin appears to not load at all. It was observed that the resin disintegrated at 75 deg. C until not much was left and partially disintegrated at 65 deg. C, which caused the column to plug in both tests after ∼336 hours. The results indicate that WTP will lose resin loading capacity if the ion exchange process is performed above 25 deg. C, and the resin will disintegrate above 65 deg. C. Therefore, WTP will have a restricted operating range of temperatures to perform the ion exchange process with this resin. PNNL and WTP are currently evaluating the operating limits of the resin in further detail. Aging in 0.5 M HNO{sub 3} also caused the resin to lose capacity above 25 deg. C and to completely dissolve at 55 deg. C. Again, WTP will have a restricted operating range of temperatures when eluting the resin with nitric acid in order to maintain resin loading capacity and avoid disintegration of the resin. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗

Ducts in the Attic? What Were They Thinking? Preprint

As energy-efficiency efforts focus increasingly on existing homes, we scratch our heads about construction decisions made 30, 40, 50-years ago and ask: 'What were they thinking?' A logical follow-on question is: 'What will folks think in 2050 about the homes we're building today?' This question can lead to a lively discussion, but the current practice that we find most alarming is placing ductsin the attic. In this paper, we explore through literature and analysis the impact duct location has on cooling load, peak demand, and energy cost in hot climates. For a typical new home in these climates, we estimate that locating ducts in attics rather than inside conditioned space increases the cooling load 0.5 to 1 ton, increases cooling costs 15% and increases demand by 0.75 kW. Theaggregate demand to service duct loss in homes built in Houston, Las Vegas, and Phoenix during the period 2000 through 2009 is estimated to be 700 MW. We present options for building homes with ducts in conditioned space and demonstrate that these options compare favorably with other common approaches to achieving electricity peak demand and consumption savings in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Transmission Line Switching under Geomagnetic Disturbances

Recently, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically-induced currents (GICs) can saturate transformers, induce hot spot heating and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal Alternating Current (AC) and 2) reactive power losses as a function of GIC. We also use this model to derive an optimization problem that protects power systems from GIC impacts through line switching, generator dispatch, and load shedding. We then employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of decisions with respect to GMD direction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence↗

High Cycle Fatigue Performance in Laser Shock Peened TC4 Titanium Alloys Subjected to Foreign Object Damage

During their service, titanium alloys are likely to suffer from the foreign object damage (FOD), resulting in a decrease in their fatigue strength. Laser shock peening (LSP) has been proved to effectively increase the damage tolerance of military engine components by introducing a magnitude compressive residual stress in the near-surface layer of alloys. In this paper, smooth specimens of a TC4 titanium alloy were used and treated by LSP and subsequently exposed to FOD, which was simulated by firing a steel sphere with a nominal velocity of 300 m/s, at 90° with the leading edge of the LSP-treated region using a light gas gun. All impacted specimens were then subjected to fatigue loading. The results showed that LSP could effectively improve the fatigue strength of the damaged specimens. The effect of LSP on the fatigue strength was assessed through fracture observations, microhardness tests and residual stress analyses. The residual stresses due to the plastic deformation caused by LSP and the FOD impact, which were found to play a crucial role on the fatigue strength, were determined using the commercial software ABAQUS.

36 MATERIALS SCIENCE↗

Wind farm response to mesoscale-driven coastal low level jets: a multiscale large eddy simulation study

Realistic atmospheric turbulence–wind farm interactions during coastal low-level jet (LLJ) events are captured using high-fidelity, mesoscale-driven large eddy simulations (LES) to understand wind turbine loads, wakes and overall performance. The simulation has been carried out using the ExaWind aeroelastic solver, AMR-Wind. The simulations have been compared against a baseline unstable case matching the wind speed, wind direction and TI at hub-height location. Results indicate that the LLJ has negative impacts on the turbine hub and tower loads, and opens up potential avenues for design load mitigation strategies.

17 WIND ENERGY↗

Demand or Request: Will Load Behave?

Power planning engineers are trained to design an electric system that satisfies predicted electrical demand under stringent conditions of availability and power quality. Like responsible custodians, we plan for the provision of electrical sustenance and shelter to those in whose care regulators have given us the responsibility to serve. Though most customers accept this nurturing gladly, a growing number are concerned with the economic costs and environmental impacts of service at a time when technology (particularly distributed generation, storage, automation, and information networks) offers alternatives for localized control and competitive service. As customers’ and their systems mature, a new relationship with the electricity provider is emerging. Demand response is perhaps the first unsteady step where the customer participates as a partner in system operations. This paper explores issues system planners need to consider as demand response matures to significant levels beyond direct load control and toward a situation where service is requested and bargains are reached with the electricity provider based on desired load behavior. On one hand, predicting load growth and behavior appears more daunting than ever. On the other, for the first time load becomes a new resource whose behavior can be influenced during system operations to balance system conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Propagation of rarefaction pulses in particulate materials with strain-softening behavior

We investigate rarefaction waves in nonlinear periodic systems with a 'softening' power-law relationship between force and displacement to understand the dynamic behavior of this class of materials. A closed form expression describing the shape of the strongly nonlinear rarefaction wave is exact for n = 1/2 and agrees well with the shape and width of the pulses resulting from discrete simulations. A chain of particles under impact was shown to propagate a rarefaction pulse as the leading pulse in initially compressive impulsive loading in the absence of dissipation. Compression pulses generated by impact quickly disintegrated into a leading rarefaction solitary wave followed by an oscillatory train. Such behavior is favorable for metamaterials design of shock absorption layers as well as tunable information transmission lines for scrambling of acoustic information.

42 ENGINEERING↗

Layout-aware I/O Scheduling for terabits data movement

Many science facilities, such as the Department of Energy's Leadership Computing Facilities and experimental facilities including the Spallation Neutron Source, Stanford Linear Accelerator Center, and Advanced Photon Source, produce massive amounts of experimental and simulation data. These data are often shared among the facilities and with collaborating institutions. Moving large datasets over the wide-area network (WAN) is a major problem inhibiting collaboration. Next-generation, terabit-networks will help alleviate the problem, however, the parallel storage systems on the endsystem hosts at these institutions can become a bottleneck for terabit data movement. The parallel storage system (PFS) is shared by simulation systems, experimental systems, analysis and visualization clusters, in addition to wide-area data movers. These competing uses often induce temporary, but significant, I/O load imbalances on the storage system, which impact the performance of all the users. The problem is a serious concern because some resources are more expensive (e.g. super computers) or have time-critical deadlines (e.g. experimental data from a light source), but parallel file systems handle all requests fairly even if some storage servers are under heavy load. This paper investigates the problem of competing workloads accessing the parallel file system and how the performance of wide-area data movement can be improved in these environments. First, we study the I/O load imbalance problems using actual I/O performance data collected from the Spider storage system at the Oak Ridge Leadership Computing Facility. Second, we present I/O optimization solutions with layout-awareness on end-system hosts for bulk data movement. With our evaluation, we show that our I/O optimization techniques can avoid the I/O congested disk groups, improving storage I/O times on parallel storage systems for terabit data movement.

Kim, Youngjae↗

Layout-Aware I/O Scheduling for Terabits Data Movement

Many science facilities, such as the Department of Energy s Leadership Computing Facilities and experimental facilities including the Spallation Neutron Source, Stanford Linear Accelerator Center, and Advanced Photon Source, produce massive amounts of experimental and simulation data. These data are often shared among the facilities and with collaborating institutions. Moving large datasets over the wide- area network (WAN) is a major problem inhibiting collaboration. Next- generation, terabit-networks will help alleviate the problem, however, the parallel storage systems on the end-system hosts at these institutions can become a bottleneck for terabit data movement. The parallel storage system (PFS) is shared by simulation systems, experimental systems, analysis and visualization clusters, in addition to wide-area data movers. These competing uses often induce temporary, but significant, I/O load imbalances on the storage system, which impact the performance of all the users. The problem is a serious concern because some resources are more expensive (e.g. super computers) or have time-critical deadlines (e.g. experimental data from a light source), but parallel file systems handle all requests fairly even if some storage servers are under heavy load. This paper investigates the problem of competing workloads accessing the parallel file system and how the performance of wide-area data movement can be improved in these environments. First, we study the I/O load imbalance problems using actual I/O performance data collected from the Spider storage system at the Oak Ridge Leadership Computing Facility. Second, we present I/O optimization solutions with layout-awareness on end-system hosts for bulk data movement. With our evaluation, we show that our I/O optimization techniques can avoid the I/O congested disk groups, improving storage I/O times on parallel storage systems for terabit data movement.

I/O and Storage↗

ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of multimode range and location on urban fuel economy on a light-duty spark-ignition based powertrain using vehicle system simulations

Multimode engine operation uses two or more combustion modes to maximize engine efficiency across the operational range of a vehicle to achieve higher overall vehicle fuel economy than is possible with a single combustion mode. More specifically for this study, multimode solutions are explored that make use of boosted SI under high load operation and other advanced combustion modes such as advanced compression ignition (ACI) under part-load conditions to enable additional engine efficiency improvements across a broader range of the engine operating map. ACI combustion has well-documented potential to improve efficiency and emissions under part-load operation but poses challenges that limit full engine speed-load range. This study investigates the potential impact of ACI operational range on simulated fuel economy to help focus research on areas with the most opportunity for improving fuel economy. These simulations make use of a vehicle model, discretized engine data, and employ a systematic exploration of ACI operational range to estimate multimode fuel economy for a mid-size passenger vehicle over U.S. Environmental Protection Agency’s Urban Dynamometer Driving Schedule. The results of this study highlight operational ranges with the highest potential fuel economy and correspondingly areas of focus for multimode research and ACI engine operation1.

Curran, Scott↗

Customer enrollment and participation in building demand management programs: A review of key factors

Increasing the efficiency and flexibility of electricity demand is necessary for ensuring a cost-effective and reliable transition to zero-carbon electricity systems. Such demand-side management (DSM) resources have been procured by utilities for decades via energy efficiency and demand response programs; however, the key drivers of program enrollment and customer participation levels remain poorly understood — even as governments and grid planners seek to scale up the deployment of DSM assets to meet climate targets. Here we systematically review the evidence on multiple factors that may influence customer enrollment and participation in building DSM programs, focusing primarily on residential and commercial buildings. We examine the contexts in which relationships between DSM factors and outcomes are most often explored and with which methods; we also score the strength, direction, and internal consistency of each factor's reported impact on the enrollment and participation outcomes. We find that studies most commonly assess the effects of economic incentives for load flexibility on program participation levels, often using simulation-based methods in lieu of measured data. Few studies focus on program enrollment outcomes or regulatory drivers of either enrollment or participation, and gaps are also evident in the coverage of emerging DSM opportunities like load electrification. Removal of structural barriers (e.g., the lack of controls infrastructure) and the use of third party services (e.g., load aggregators) are the factors with the largest positive impacts on DSM outcomes, but no single factor emerges as clearly most impactful. For a given factor, the range of reported impacts typically varies widely across the relevant studies reviewed. Our findings provide a snapshot of the state of knowledge about building DSM and customer decision-making, and they expose key gaps in understanding that must be filled if building DSM is to expand as a critical resource for operating clean power grids.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗