Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Detecting wetland changes in Shanghai, China using FORMOSAT and Landsat TM imagery

Understanding the state of wetland ecosystems and their changes at the national and local levels is critical for wetland conservation, management, decision-making, and policy development practices. This study analyzed the wetlands in Shanghai, a province-level city, using remote sensing, image processing, and geographic information systems (GIS) techniques based on the Chinese national wetland inventory procedure and standards. FORMOSAT imagery acquired in 2012 and Navy nautical charts of the Yangtze estuarine area were used in conjunction with object-oriented segmentation, expert interpretation, and field validation to determine wetland status. Landsat imagery from 1985, 1995, 2000, 2003 and 2013 as well as social-economic data collected from 1985 to 2013 were used to further assess wetland changes. In 2013, Shanghai contained 376,970.6 ha of wetlands, and 78.8% of all wetlands were in marine or estuarine systems. Estuarine waters comprised the single largest wetland category. Between the first national wetland inventory in 2003 and the second national wetland inventory in 2013, Shanghai lost 50,519.13 ha of wetlands, amounting to a mean annual loss rate of 1.2% or an 11.8% loss over the decade. Declines were proportionately higher in marine and estuarine wetlands, with an annual loss of 1.8%, while there was a sharp increase of 1882.6% in constructed water storage areas for human uses. Diking, filling, impoundment and reclamation, which are all attributable to the economic development and urbanization associated with population increases, were the major factors that explained the gain and loss of wetlands. Additional factors affecting wetland losses and gains include sediment trapping by the hydropower system, which reduces supply to the estuary and erodes wetlands, and sediment trapping by the jetties, spur dikes, and diversion bulwark associated with a navigation channel deepening project, which has the converse effect, increasing saltmarsh wetland area at Jiuduansha shoal by three times between 2000 and 2013.

Tian, Bo↗

Low-Contrast Detail Phantom: Proof of Concept

To investigate the concept of filling the air gaps of the conventional contrast detail phantom (CDP) with various concentrations of contrast media, and to develop a variable level of attenuation-level differential phantoms that could be more appropriate for contrast measurements in some radiology cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Implementation of an Electronic Learning Module for Volumetric Image-Guided Radiation Therapy

Image-guided radiation therapy (IGRT) through daily cone-beam computed tomography (CBCT) has significantly impacted the role of the radiation therapist at our institution; continuing education is crucial to ensure safe practice of technology in the clinical environment. The purpose of this work was to develop and implement an electronic learning (eLearning) module as a yearly refresher for CBCT-practicing radiation therapists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DINO: Divergent node cloning for sustained redundancy in HPC

Complexity and scale of next generation HPC systems pose significant challenges in fault resilience methods such that contemporary checkpoint/restart (C/R) methods that address fail-stop behavior may be insufficient. Redundant computing has been proposed as an alternative at extreme scale. Triple redundancy has an advantage over C/R in that it can also detect silent data corruption (SDC) and then correct results via voting. However, current redundant computing approaches do not repair failed or corrupted replicas. Consequently, SDCs can no longer be detected after a replica failure since the system has been degraded to dual redundancy without voting capability. Hence, a job may have to be aborted if voting uncovers mismatching results between the remaining two replicas. And while replicas are logically equivalent, they may have divergent runtime states during job execution, which presents a challenge to simply creating new replicas dynamically. This problem is addressed by, DIvergent NOde cloning (DINO), a redundant execution environment that quickly recovers from hard failures. DINO consists of a novel node cloning service integrated into the MPI runtime system that solves the problem of consolidating divergent states among replicas on-the-fly. With DINO, after degradation to dual redundancy, a good replica can be quickly cloned so that triple redundancy is restored. We present experimental results over 9 NAS Parallel Benchmarks (NPB), Sweep3D and LULESH. Results confirm the applicability of the approach and the correctness of the recovery process and indicate that DINO can recover from failures nearly instantly. The cloning overhead depends on the process image size that needs to be transferred between source and destination of the clone operation and varies between 5.60 to 90.48 s. Here, simulation results with our model show that dual redundancy with DINO recovery always outperforms 2x and surpasses 3x redundancy on up to 1 million nodes. To the best of our knowledge, the design and implementation for repairing failed replicas in redundant MPI computing is unprecedented.

97 MATHEMATICS AND COMPUTING↗

Structural properties of ultrafine Ba-hexaferrite nanoparticles

Crystal structure of ultrafine Ba-hexaferrite (BaFe{sub 12}O{sub 19}) nanoparticles was studied using X-ray diffractometry (XRD), high-resolution transmission electron microscopy (HRTEM), energy-dispersive X-ray spectroscopy (EDXS), X-ray absorption fine structure (XAFS), and Moessbauer spectroscopy (MS), to be compared to the structure of larger nanoparticles and the bulk. The nanoparticles were synthesized with hydrothermal treatment of an appropriate suspension of Ba and Fe hydroxides in the presence of a large excess of OH{sup -}. The ultrafine nanoparticles were formed in a discoid shape, {approx}10 nm wide and only {approx}3 nm thick, comparable to the size of the hexagonal unit cell in the c-direction. The HRTEM image analysis confirmed the hexaferrite structure, whereas EDXS showed the composition matching the BaFe{sub 12}O{sub 19} formula. XAFS and MS analyses showed considerable disorder of the structure, most probably responsible for the low magnetization. - Graphical abstract: Left: HREM image of an ultrafine Ba-hexaferrite nanoparticle (inset: TEM image of the nanoparticles); Right: the experimental HRTEM image is compared with calculated image and corresponding atomic model. Highlights: Black-Right-Pointing-Pointer Crystal structure of ultrafine Ba-hexaferrite (BaFe{sub 12}O{sub 19}) nanoparticles was compared to the structure of the bulk. Black-Right-Pointing-Pointer Thickness the discoid nanoparticles was comparable to the size of the hexagonal unit cell in the c-direction. Black-Right-Pointing-Pointer Considerable disorder of the nanoparticles' structure is most probably responsible for their low magnetization.

36 MATERIALS SCIENCE↗

Comparative determination of the {alpha}/{beta} phase fraction in {alpha}+{beta}-titanium alloys using X-ray diffraction and electron microscopy

A comparison is made between the measured {alpha}/{beta} phase fractions in Ti-6246 using X-ray diffraction (XRD) and electron microscopy. Image analysis of SEM and TEM images was compared to the phase fraction estimate obtained using electron backscattered diffraction, lab and high-energy synchrotron XRD. There was a good agreement between the electron microscopic and diffraction techniques, provided that the microstructural parameters of grain size and texture are estimated correctly when using quantitative Rietveld refinement.

36 MATERIALS SCIENCE↗

Geometrical characterization of perlite-metal syntactic foam

This paper introduces an improved method for the detailed geometrical characterization of perlite-metal syntactic foam. This novel metallic foam is created by infiltrating a packed bed of expanded perlite particles with liquid aluminium alloy. The geometry of the solidified metal is thus defined by the perlite particle shape, size and morphology. The method is based on a segmented micro-computed tomography data and allows for automated determination of the distributions of pore size, sphericity, orientation and location. The pore (i.e. particle) size distribution and pore orientation is determined by a multi-criteria k-nearest neighbour algorithm for pore identification. The results indicate a weak density gradient parallel to the casting direction and a slight preference of particle orientation perpendicular to the casting direction. - Highlights: •A new method for identification of pores in porous materials was developed. •It was applied on perlite-metal syntactic foam samples. •A porosity decrease in the axial direction of the samples was determined. •Pore shape analysis showed a high percentage of spherical pores. •Orientation analysis showed that more pores are oriented in the radial direction.

36 MATERIALS SCIENCE↗

Combined multi-analytical approach for study of pore system in bricks: How much porosity is there?

During the firing of bricks, mineralogical and textural transformations produce an artificial aggregate characterised by significant porosity. Particularly as regards pore-size distribution and the interconnection model, porosity is an important parameter to evaluate and predict the durability of bricks. The pore system is in fact the main element, which correlates building materials and their environment (especially in cases of aggressive weathering, e.g., salt crystallisation and freeze-thaw cycles) and determines their durability. Four industrial bricks with differing compositions and firing temperatures were analysed with “direct” and “indirect” techniques, traditional methods (mercury intrusion porosimetry, hydric tests, nitrogen adsorption) and new analytical approaches based on digital image reconstruction of 2D and 3D models (back-scattered electrons and computerised X-ray micro-Tomography, respectively). The comparison of results from different analytical methods in the “overlapping ranges” of porosity and the careful reconstruction of a cumulative curve, allowed overcoming their specific limitations and achieving better knowledge on the pore system of bricks. - Highlights: •Pore-size distribution and structure of the pore system in four commercial bricks •A multi-analytical approach combining “direct” and “indirect” techniques •Traditional methods vs. new approaches based on 2D/3D digital image reconstruction •The use of “overlapping ranges” to overcome the limitations of various techniques.

36 MATERIALS SCIENCE↗

Characterization of the porous structures of the green body and sintered biomedical titanium scaffolds with micro-computed tomography

The present research was aimed at gaining an understanding of the porous structure changes from the green body through water leaching and sintering to titanium scaffolds. Micro-computed tomography (micro-CT) was performed to generate 3D models of titanium scaffold preforms containing carbamide space-holding particles and sintered scaffolds containing macro- and micro-pores. The porosity values and structural parameters were determined by means of image analysis. The result showed that the porosity values, macro-pore sizes, connectivity densities and specific surface areas of the titanium scaffolds sintered at 1200 °C for 3 h did not significantly deviate from those of the green structures with various volume fractions of the space holder. Titanium scaffolds with a maximum specific surface area could be produced with an addition of 60–65 vol% carbamide particles to the matrix powder. The connectivity of pores inside the scaffold increased with rising volume fraction of the space holder. The shrinkage of the scaffolds prepared with > 50 vol% carbamide space holder, occurring during sintering, was caused by the reductions of macro-pore sizes and micro-pore sizes as well as the thickness of struts. In conclusion, the final porous structural characteristics of titanium scaffolds could be estimated from those of the green body. - Highlights: •Porous structures of green body and sintered titanium scaffolds was studied. •Porous structures of both samples were quantitatively characterized with micro-CT. •Porous structures of scaffolds could be controlled from the green body. •Shrinkage mechanisms of titanium scaffolds during sintering was established.

36 MATERIALS SCIENCE↗

Effective Doses in Four-Dimensional Computed Tomography for Lung Radiotherapy Planning

The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using injectable hydrogel markers to assess resimulation for boost target volume definition in a patient undergoing whole-breast radiotherapy

Several publications have recommended that patients undergoing whole-breast radiotherapy be resimulated for boost planning. The rationale for this is that the seroma may be smaller when compared with the initial simulation. However, the decision remains whether to use the earlier or later images to define an appropriate boost target volume. A patient undergoing whole-breast radiotherapy had new, injectable, temporary hydrogel fiducial markers placed 1 to 3 cm from the seroma at the time of initial simulation. The patient was resimulated 4.5 weeks later for conformal photon boost planning. Computed tomography (CT) scans acquired at the beginning and the end of whole-breast radiotherapy showed that shrinkage of the lumpectomy cavity was not matched by a corresponding reduction in the surrounding tissue volume, as demarcated by hydrogel markers. This observation called into question the usual interpretation of cavity shrinkage for boost target definition. For this patient, it was decided to define the boost target volume on the initial planning CT instead of the new CT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans generated from deformable image registration displacement vectors

There is a reduction in cardiac dose for left-sided breast radiotherapy during treatment with deep inspiration breath-hold (DIBH) when compared with treatment with free breathing (FB). Various levels of DIBH may occur for different treatment fractions. Dosimetric effects due to this and other motions are a major component of uncertainty in radiotherapy in this setting. Recent developments in deformable registration techniques allow displacement vectors between various temporal and spatial patient representations to be digitally quantified. We propose a method to evaluate the dosimetric effect to the heart from variable reproducibility of DIBH by using deformable registration to create new anatomical computed tomography (CT) scans. From deformable registration, 3-dimensional deformation vectors are generated with FB and DIBH. The obtained deformation vectors are scaled to 75%, 90%, and 110% and are applied to the reference image to create new CT scans at these inspirational levels. The scans are then imported into the treatment planning system and dose calculations are performed. The average mean dose to the heart was 2.5 Gy (0.7 to 9.6 Gy) at FB, 1.2 Gy (0.6 to 3.8 Gy, p < 0.001) at 75% inspiration, 1.1 Gy (0.6 to 3.1 Gy, p = 0.004) at 90% inspiration, 1.0 Gy (0.6 to 3.0 Gy) at 100% inspiration or DIBH, and 1.0 Gy (0.6 to 2.8 Gy, p = 0.019) at 110% inspiration. The average mean dose to the left anterior descending artery (LAD) was 19.9 Gy (2.4 to 46.4 Gy), 8.6 Gy (2.0 to 43.8 Gy, p < 0.001), 7.2 Gy (1.9 to 40.1 Gy, p = 0.035), 6.5 Gy (1.8 to 34.7 Gy), and 5.3 Gy (1.5 to 31.5 Gy, p < 0.001), correspondingly. This novel method enables numerous anatomical situations to be mimicked and quantifies the dosimetric effect they have on a treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Couch height–based patient setup for abdominal radiation therapy

There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of setup error in supine breast radiotherapy using cone-beam computed tomography

Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rotation invariants of vector fields from orthogonal moments

Vector field images are a type of new multidimensional data that appear in many engineering areas. Although the vector fields can be visualized as images, they differ from graylevel and color images in several aspects. In order to analyze them, special methods and algorithms must be originally developed or substantially adapted from the traditional image processing area. Here, we propose a method for the description and matching of vector field patterns under an unknown rotation of the field. Rotation of a vector field is so-called total rotation, where the action is applied not only on the spatial coordinates but also on the field values. Invariants of vector fields with respect to total rotation constructed from orthogonal Gaussian–Hermite moments and Zernike moments are introduced. Their numerical stability is shown to be better than that of the invariants published so far. We demonstrate their usefulness in a real world template matching application of rotated vector fields.

97 MATHEMATICS AND COMPUTING↗

Advanced detector signal acquisition and electron beam scanning for high resolution SEM imaging

We report the advancement of materials science at the mesoscale requires improvements in both sampling volumes/areas and spatial resolution in order to make statistically significant measurements of microstructures that influence higher-order material properties, such as fatigue and fracture. Therefore, SEM-based techniques have become desirable due to improvements in imaging resolution, large sample handling capability, and flexibility for in-situ instrumentation. By using fast sampling of SEM electron detector signals, intrinsic beam scanning defects have been identified that are related to the response time of the SEM electron beam deflectors and electron detectors. Mitigation of these beam scanning defects using detector sampling approaches and an adaptive model for settling time is shown to produce higher resolution SEM images, at faster image acquisition times, with a means to quantify the different response functions for various beam deflectors and detectors including those for electrons and ions.

47 OTHER INSTRUMENTATION↗

Correlation between cationic lipid-based transfection and cell division

We evaluate the temporal relation between protein expression by cationic lipid-mediated transfection and cell division using time lapse fluorescence microscopy. Detailed image analysis provides new insights on the single cell level while simultaneously achieving appropriate statistics. Earlier evidence by less direct methods such as flow cytometry indicates a primary route for transfection involving nuclear envelope breakdown, but also suggests the existence of a pathway independent of mitosis. We confirm and quantify both mechanisms. We found the timing for successful transfection to be unexpectedly flexible, contrary to assertions of a narrow time window. Specifically, cells dividing more than 24 h after exposure to the transfection medium express the probed protein at a comparable level to cells in a mitotic state during or shortly after transfection. This finding can have a profound impact on the guidance and development of non-viral gene delivery materials. - Highlights: • Cationic lipid-based transfection supports protein expression without cell division. • Protein expression is unrelated to cell cycle status at the time of transfection. • Time-lapse imaging provides direct evaluation without statistical averaging. • Lipoplex dissociation is a likely target for improvement of transfection efficiency.

60 APPLIED LIFE SCIENCES↗