Disparate quasiballistic heat conduction regimes from periodic heat sources on a substrate
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Experimental and modeling investigations of the high βp scenarios on the DIII-D and EAST tokamaks show advantages in high energy confinement, avoidance of n = 1 MHD, and core-edge integration with reduced heat flux, making this scenario an attractive option for CFETR steady-state operation. Experiments show that plasmas with high confinement and high density can be achieved with neutral beam injection on DIII-D (β p ~ 2.2, β N ~ 3.5, f BS ~ 50%, f Gw ~ 1.0, H 98y2 ~ 1.5) and pure RF power on EAST (β P ~ 2.0, β N ~ 1.6, f BS ~ 50%, f Gw ~ 0.8, H 98y2 > 1.3). By tailoring the current density profile, a q-profile with local (off-axis) negative shear is achieved that yields improved confinement and MHD stability. Transport analysis and simulation suggest that the combination of high density gradient and high Shafranov shift allows turbulence stabilization and higher confinement. Using on-axis ECH injection, tungsten accumulation is avoided on EAST, and this is reproduced in modeling. Reduced heat flux (by >40%) and maintenance of high core confinement is achieved with active feedback control of the radiated divertor, an important result for long pulse operation in tokamaks. In conclusion, the improved physics understanding and validated modeling tools are used to design a 1GW steady-state scenario for CFETR.
Boilers are combustion devices that provide process heat and are integral to many industrial facilities. Historically, outside of the pulp and paper industry, most boilers burned fossil fuels, although interest in decarbonization has been leading to an increased use of renewable fuels in boilers. These boilers, including those in the biorefineries, are often large sources of air pollutant emissions, and the characterization of these emissions is critical to obtaining air permits and ensuring protection of the surrounding air quality. Several industrial boilers and new biorefineries allow utilization of biomass-derived fuels (e.g. wastewater sludge, lignin, etc.) produced during their operation as a fuel for the boiler to meet process energy needs. However, there is limited empirical data on emission factors for the burning of unconventional fuels, such as solid-gas mixtures containing biomass residues. To fill this gap, we carry out a comprehensive data survey, collecting information on emission factors for boilers burning either a single or a mixture of solid and gaseous biomass-derived fuels. We review multiple hard-to-obtain and unconventional data sources, such as air permit applications, stack test data, and industry-sponsored data collection efforts, to compile emission factors for biomass-derived fuels. We then compare this data with wood residue emission factors from the U.S. Environmental Protection Agency’s AP-42 emission factor database. Our results indicate that the emission factors for boilers burning unconventional fuels vary widely depending on the fuel composition, boiler type, and fuel characteristics. Overall, we find that median emission factors of selected biomass-derived fuels are typically lower than those of wood residue boilers in AP-42. The information collected herein could be useful to permitting agencies and industries utilizing boilers who may want to reduce the carbon impact of their facilities by combusting biomass-derived wastes for process energy needs, for more accurate emission estimation for permitting.
With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.
Work space for in development Economic Dispatch Application. Multi-purpose open-source control algorithms that will ensure real-time optimal operation, increase electric grid reliability, and lead to the goal of clean, efficient, reliable and affordable next generation building-integrated combine cooling, heating and power (CHP) system.The CHP system could include conventional heating, ventilation, air conditioning (HVAC) systems, distributed generation (DG), local storage (both thermal and electric) and local solar photovoltaic (PV) systems.
This study conducts an intercomparison of the column-integrated moist static energy (MSE) and water vapor budget of the Madden–Julian oscillation (MJO) among six modern global reanalysis products (RAs). Inter-RA differences in the mean MSE, MJO MSE anomalies, individual MSE budget terms, and their relative contributions to the propagation and maintenance of MJO MSE anomalies are examined. Also investigated is the relationship between the MJO column water vapor (CWV) budget residuals with the other CWV budget terms as well as with the two parameters that characterize cloud–radiation feedback and moisture–convection coupling. Results show a noticeable inter-RA spread in the mean-state MSE, especially its vertical structure. In all RAs, horizontal MSE advection dominates the propagation of the MJO MSE while column-integrated longwave radiative heating and vertical MSE advection are found to be the key processes for MJO maintenance. The MSE budget terms directly affected by the model parameterization schemes exhibit high uncertainty. The differences in anomalous vertical velocity mainly contribute to the large differences in vertical MSE advection among the RAs. The budget residuals show large inter-RA differences and have nonnegligible contributions to MJO maintenance and propagation in most RAs. RAs that underestimate (overestimate) the strength of cloud–radiation feedback and the convective moisture adjustment time scale tend to have positive (negative) MJO CWV budget residual, indicating the critical role of these processes in the maintenance of MJO CWV anomalies. Our results emphasize that a correct representation of the interactions among moisture, convection, cloud, and radiation is the key for an accurate depiction of the MJO MSE and CWV budget in RAs.
PRESENTATION for CONFERENCE PAPER: The Microreactor Applications, Research, Validation, and Evaluation (MARVEL) Reactor is a small liquid-metal thermal reactor that will be built at the Idaho National Laboratory to demonstrate design and operating processes for microreactors, microgrid integration, and process heat applications. Power conversion in the MARVEL design is provided by Stirling engines, which have disadvantages in nuclear environments. Compared to Stirling engine performance, some alternative power cycles can increase power production when coupled to a liquid-metal thermal reactor. In this paper, the thermal efficiency of MARVEL’s power production with Stirling engines is compared to the thermal efficiency of power production with MARVEL and alternative power cycles. Those cycles include a superheated Rankine cycle, open and closed Brayton cycles, and a supercritical carbon dioxide cycle. All cycles (except the Stirling engines) were modeled with an intermediate helium loop to meet MARVEL’s principal design criteria. All models are simple designs with conservative assumptions for consistent comparison. Detailed optimization will depend largely on reactor location and application, and the relative merit of each cycle is discussed for different environmental conditions. The study informs significant early decisions on power cycle design and economics for deployment of advanced microreactors as they move from theory and concept to execution.
The project goal is to enable multijunction cells to operate at greater than 2000× suns intensity with efficiency above forty percent. To achieve this goal the recipients have developed a robust high-bandgap tunnel junction, reduce series resistance, and integrated a practical heat dissipation scheme.
Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies amongst regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.
Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies among regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.
This report summarizes the available data for fuel pins available to the project and selects samples for integral LOCA tests, heating tests, and irradiation in the Advanced Test Reactor.
This project assessed technology strategies for nuclear power plants that could improve economic competitiveness in uncertain future electricity markets. Heat storage is a promising class of technologies that would allow reactors to produce steam at maximum power while giving the plant operator the flexibility to sell more electricity at higher prices. We used the Texas (ERCOT) and New England (ISO-NE) electricity markets to evaluate future market scenarios for heat storage. Hourly unit commitment and capacity change models were used to model short- and long-term market dynamics. Three heat storage technologies were identified as the most promising for nearterm deployment with existing light-water reactors: steam accumulators, twotank molten salt storage, and high-temperature-compatible concrete. We developed technoeconomic models for each of these technologies to estimate direct, overnight capital costs based on the output power [MW], energy storage capacity [MWh or GJ th ], and heat loss rate [%/hr]. Our modeling results found that adding heat storage to a nuclear power plant could increase net revenue in some cases. The greatest improvements were seen when increasing the heat storage power output with a separate steam turbine. Increasing energy storage capacity was beneficial through 12 hours of full-output storage time, but there was little to no benefit for higher energy/ power ratios. High natural gas prices as well as increasing amounts of solar PV and wind were both beneficial to storage economics, while high demand and load growth and a carbon tax were helpful in some scenarios. We recommend that heat storage systems for nuclear power plants be developed with multiple future markets in mind, namely electricity generation, operating reserves, long-term capacity, and industrial heat. Heat storage system Integration risk should be mitigated early in the development process to accelerate deployments.
GE Power (GEP), a division of General Electric Company, performed a gas turbine technology development program that integrated Aerodynamic and Heat Transfer advances as an important and innovative step towards the DOE goal of 65% combined cycle efficiency. Improved efficiency will also contribute towards the reduction in the cost of electricity identified by the DOE for the US through reduced fuel consumption, and through lowering the capital cost of the generating equipment. It is currently predicted that the result of this project will enable 0.40~0.65 pt in combined cycle efficiency improvement. This technology will be directly applicable to gas turbines utilizing coal gasification processes where hydrogen-rich coal-derived synthesis gas is produced with natural gas being the developmental fuel.
Kairos Power, LLC, is developing its version of the Fluoride-cooled High-temperature Reactor, the KP-FHR. The design uses a pebble bed core with fluoride salt as a coolant. The pebbles used in the KP-FHR have a diameter of 4 cm, with a shell fuel region where TRISO particles are embedded. A Pebble bed core design is adopted by several Gen IV reactors, They boast many benefits, such as fuel integrity, highly efficient heat transfer, and passive safety. However, it is challenging to accurately predict temperature and flow inside a pebble bed. Traditional approaches use the porous media model, which regards the pebble bed as a continuous medium, but with different temperature fields representing different levels, such as the fluid temperature, pebble surface temperature, and pebble center temperature. Empirical heat transfer correlations are adopted to calculate the heat transfer coefficient between different phases. However, empirical correlations are usually validated with experimental data, which usually lacks detail inside the pebble bed. The available experimental data is also generally at a high Reynolds number, which falls outside of the conditions of KP-FHR. Explicit computational fluid dynamics (CFD) simulations of randomly packed pebble beds have only become feasible recently. This is thanks to the rapid development of computational power and scalable algorithms. In this work, we used the Spectral Element Method (SEM) CFD code NekRS to simulate the randomly packed pebble bed in a cylindrical container. NekRS, which is the GPU variant of Nek5000, but refactored to utilize the computational power of GPUs using the OCCA library to run on hybrid architecture high performance computing systems. It was initially developed with the libParamunal library, but truncated and tuned for large-scale turbulence simulation. As a result, the SEM reaches higher precision with the same degrees of freedom by using a high-order Lagrange polynomial basis distributed on Gauss-Lobatto-Legendre quadrature inside each element, compared to lower-order methods, such the Finite Volume Method and Finite Element Method. The report is divided into five parts. We start with a general discussion of the pebble bed reactor, along with a specific investigation into the KP-FHR. The second part presents the numerical methodology. In the third part, we study a modular pebble bed with 1741 pebbles in a container of 7 pebble-diameter radius. Beyond LES simulations done by NekRS, we also leveraged the thermal radiation model in OpenFOAM to study heat transfer under no-forced-flow scenarios. Then, in the fourth part we simulated a pebble bed similar to the size of the Hermes Test Reactor. The total number of pebbles is in these simulations is 34,374. The container radius is 14 pebble-diameters. Finally, the report concludes in part five, with a discussion of future work.
Carbon Collect Inc., along with Arizona State University, the Electric Power Research Institute (EPRI), PM Group, and Trimeric Corporation, completed an initial design of a commercial-scale, passive direct air capture (DAC) system termed “carbon trees” that will capture, separate, and store at least 100,000 tonnes/year of carbon dioxide (CO2) from air (net basis). Passive DAC is unique among DAC technologies in that passive air delivery by wind avoids the energy penalty of forced convection. Carbon Collect Inc.’s sorbent-agnostic approach offers the flexibility to choose sorbents for a wide range of climates. A combination of steam, low-grade heat, and vacuum releases the CO2 from the sorbent, which is extracted from the chamber and purified and compressed for geological storage. A commercial carbon tree forest combines the output of several thousand trees for compression and purification with high heat and energy integration. The project team prepared an initial engineering design package for each of three geographically diverse host sites throughout the United States to better understand the effect of local/regional ambient conditions on DAC system performance and project costs. A techno-economic analysis, life cycle analysis, business case analysis, and an environmental, health, and safety risks assessment were also completed for each of the three geographically diverse host sites.
Design optimization of out-of-core cylindrical thermionic converter module with heat pipes and integral finned radiator
The design of a convective cooling system for an aluminum alloy airframe was established to verify preliminary weight estimates and to define future development requirements. A water glycol coolant was circulated through a closed loop network of supply and return lines to absorb incident aerodynamic heating from structural skin panels with integral passages and to transfer this heat input to a heat exchanger where it is rejected to the hydrogen fuel. Partial shielding of the aluminum alloy structure reduced heat loads to levels compatible with engine fuel flow requirements.
The results are reported of the advanced hydrogen/oxygen thrust chamber design analysis program. The primary objectives of this program were to: (1) provide an in-depth analytical investigation to develop thrust chamber cooling and fatigue life limitations of an advanced, high pressure, high performance H2/O2 engine design of 20,000-pounds (88960.0 N) thrust; and (2) integrate the existing heat transfer analysis, thermal fatigue and stress aspects for advanced chambers into a comprehensive computer program. Thrust chamber designs and analyses were performed to evaluate various combustor materials, coolant passage configurations (tubes and channels), and cooling circuits to define the nominal 1900 psia (1.31 x 10 to the 7th power N/sq m) chamber pressure, 300-cycle life thrust chamber. The cycle life capability of the selected configuration was then determined for three duty cycles. Also the influence of cycle life and chamber pressure on thrust chamber design was investigated by varying in cycle life requirements at the nominal chamber pressure and by varying the chamber pressure at the nominal cycle life requirement.