Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Error field impact on mode locking and divertor heat flux in NSTX-U

During the 2016 NSTX-U experimental campaign, locked modes in the plasma edge presented clear evidence of the presence of error fields. Extensive metrology and plasma response modeling with IPEC and M3D-C1 have been conducted to understand the various sources of error fields in NSTX-U as built in 2016, and to determine which of these sources have the greatest effect on the plasma. In particular, modeling finds that the error field from misalignment of the toroidal field (TF) coils may have a significant effect on the plasma. The response to the TF error field is shown to depend on the presence of a q = 1 surface, in qualitative agreement with experimental observations. It is found that certain characteristics of the TF error field present new challenges for error field correction. Specifically, the error field spectrum differs significantly from that of coils on the low-field side (such as the NSTX-U error field correction coils), and does not resonate strongly with the dominant kink mode, thus potentially requiring a multi-mode correction. Moreover, to mitigate heat fluxes using poloidal flux expansion, the pitch angle at the divertor plates must be small (~1°). It is shown that uncorrected error fields may result in potentially significant local perturbation to the pitch angle. Estimates for coil alignment tolerances in NSTX-U are derived based on consideration of both heat flux and core resonant fields independently.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specific heat to H c⁢2 : Evidence for nodes or deep minima in the superconducting gap of underdoped and overdoped Ba(Fe 1–$x$ Co $x$ ) 2 As 2

Low-temperature specific heat, C, in magnetic fields up to Hc2 is reported for underdoped Ba(Fe 0.955 Co 0.045 ) 2 As 2 (T c = 8 K) and for three overdoped samples Ba(Fe 1–x Co x ) 2 As 2 (x = 0.103, 0.13, and 0.15; T c = 17.2, 16.5, and 11.7 K, respectively). Previous measurements of thermal conductivity (as a function of temperature and field) and penetration depth on comparable-composition samples gave some disagreement as to whether there was fully gapped/nodal behavior in the under-/overdoped materials, respectively. The present work shows that the measured behavior of the specific heat γ (∝C/T as T → 0, i.e., a measure of the electronic density of states at the Fermi energy) as a function of field approximately obeys γ ∝ H 0.5±0.1 , similar to the Volovik effect for nodal superconductors, for both the underdoped and the most overdoped Co samples. However, for the two overdoped compositions x = 0.103 and 0.13, the low-field (H ≤ 10 T) data show a Volovik-like behavior of γ ∝ H 0.3–0.4 , followed by an inflection point, followed at higher fields by γ ∝ H 1 . Here, we argue that, within the two-band theory of superconductivity, an inflection point may occur if the interband coupling is dominant.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopic parameters from high-resolution specific heat measurements on superoptimally substituted BaFe 2 ( As 1 - x P x ) 2 single crystals

We investigate the electronic specific heat of superoptimally substituted BaFe 2 (As 1-x P x ) 2 single crystals in the superconducting state using high-resolution nanocalorimetry. From the measurements, we extract the substitution dependence of the condensation energy, superconducting gap Δ, and related microscopic parameters. We find that the anomalous scaling of the specific heat jump ΔC ∝ to T$3\atop{c}$ , found in many iron-based superconductors, in this system originates from a T c -dependent ratio Delta/k B T c in combination with a substitution-dependent density of states N(epsilon(F)). A clear enhancement is seen in the effective mass m* as the composition approaches the value that has been associated with a quantum critical point at optimum substitution. However, a simultaneous increase in the superconducting carrier concentration n s yields a penetration depth lambda that decreases with increasing T c without sharp divergence at the quantum critical point. Uemura scaling indicates that T c is governed by the Fermi temperature T F for this multiband system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Overview of recent SCALE activities for Non-LWR inventory and decay heat analysis

In 2019, the US Nuclear Regulatory Commission initiated a project for the development and assessments of non-light-water reactor (non-LWR) accident progression using the SCALE and MELCOR simulation tools. SCALE simulations are used to generate nuclide inventories, full-core power distributions, decay heat, and kinetics parameters to initialize MELCOR simulations of severe accident scenarios. Five non-LWR concepts were studied: high-temperature gas-cooled reactor (HTGR), heat pipe reactor (HPR), high-temperature fluoride salt-cooled reactor (FHR), molten salt-fueled reactor (MSR), and sodium-cooled fast reactor (SFR). This paper summarizes the SCALE results obtained in 2021 for the first three non-LWR concepts, compares characteristics and results to common LWRs, and provides the strategy for the analysis of the remaining two non-LWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Supercritical CO2 studies: micro-channel heat transfer for reactor heat exchangers & cycle design

An experimental facility was built to perform heat transfer and pressure drop measurements in supercritical carbon dioxide. Inlet temperatures ranged from 30-125 degress C with mass velocities ranging from 118-1050 kg/m 2 s and system pressures of 7.5-10.2 MPa. Tests were performed in horizontal, upward, and downward flow conditions to test the influence of buoyance foreces on the heat transfer. The majority of experiments were performed in the cooling mode, where the fluid decreases in temperature over the test section length.

Corradini, Michael↗

Energy Savings and Peak Demand Reduction of a SEER 21 Heat Pump vs. a SEER 13 Heat Pump with Attic and Indoor Duct Systems

This report describes results of experiments that were conducted in an unoccupied 1600 square foot house--the Manufactured Housing (MH Lab) at the Florida Solar Energy Center (FSEC)--to evaluate the delivered performance as well as the relative performance of a SEER 21 variable capacity heat pump versus a SEER 13 heat pump. The performance was evaluated with two different duct systems: a standard attic duct system and an indoor duct system located in a dropped-ceiling space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency Water Heating Technology Development Final Report. Part I, Lab/Field Performance Evaluation and Accelerated Life Testing of a Hybrid Electric Heat Pump Water Heater (HPWH)

DOE has supported efforts for many years with the objective of getting a water heater that uses heat pump technology (aka a heat pump water heater or HPWH) successfully on the residential equipment market. The most recent previous effort (1999-2002) produced a product that performed very well in ORNL-led accelerated durability and field tests. The commercial partner for this effort, Enviromaster International (EMI), introduced the product to the market under the trade name Watter$aver in 2002 but ceased production in 2005 due to low sales. A combination of high sales price and lack of any significant infrastructure for service after the sale were the principal reasons for the failure of this effort. What was needed for market success was a commercial partner with the manufacturing and market distribution capability necessary to allow economies of scale to lead to a viable unit price together with a strong customer service infrastructure. General Electric certainly meets these requirements, and knowing of ORNL s expertise in this area, approached ORNL with the proposal to partner in a CRADA to produce a high efficiency electric water heater. A CRADA with GE was initiated early in Fiscal Year, 2008. GE initially named its product the Hybrid Electric Water Heater (HEWH).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency Water Heating Technology Development Final Report, Part II: CO 2 and Absorption-Based Residential Heat Pump Water Heater Development

The two objectives of this project were to 1.demonstrate an affordable path to an ENERGY STAR qualified electric heat pump water heater (HPWH) based on low-global warming potential (GWP) CO 2 refrigerant, and 2.demonstrate an affordable path to a gas-fired absorption-based heat pump water heater with a gas energy factor (EF) greater than 1.0. The first objective has been met, and the project has identified a promising low-cost option capable of meeting the second objective. This report documents the process followed and results obtained in addressing these objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Guidance to Address Barriers to Combined Heat and Power and Waste Heat to Power

Congress directed that the US Department of Energy (DOE) initiate a review of interconnection rules to identify barriers to interconnection and ways to better integrate combined heat and power (CHP) and waste heat to power (WHP) in the electric grid. Oak Ridge National Laboratory (ORNL) supports DOE by providing technical assistance for CHP. DOE tasked ORNL with the interconnection review and development of model guidance to enable developers and CHP owners to interconnect more CHP. This report summarizes the work that DOE initiated in response to the congressional request.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Precipitation-Strengthening Heat-Resistant Austenitic Stainless Steels for Life-Prediction Modeling

In this study, the role of minor alloying additions in 347H stainless steels (UNS34709, ASTM A240/240M) on creep-rupture properties at 650-750°C and microstructure evolution during isothermal exposure at 750°C has been investigated, aiming to provide the experimental dataset as boundary conditions of physics-based modeling for material/component life prediction. Four different 347H heats containing various amounts of boron and nitrogen additions were prepared and evaluated. The combined additions of B and N are found to stabilize the strengthening secondary M23C6 carbides and retarding the transition from M23C6 to sigma phase precipitates during thermal exposure. The observed kinetics of microstructure evolution reasonably explains the improvement of creep-rupture properties of 347H stainless steels with the B and N additions.

Yamamoto, Yukinori↗

ENTROPY VS. ENERGY WAVEFORM PROCESSING: A COMPARISON ON THE HEAT EQUATION

Virtually all modern imaging devices function by collecting either electromagnetic or acoustic backscattered waves and using the energy carried by these waves to determine pixel values that build up what is basically an ”energy” picture. However, waves also carry ”informa- tion” that also may be used to compute the pixel values in an image. We have employed several measures of information, all of which are based on different forms of entropy. Numerous published studies have demonstrated the advantages of entropy, or “information imaging”, over conventional methods for materials characterization and medical imaging. Similar results also have been obtained with microwaves. The most sensitive information measure appears to be the joint entropy of the backscattered wave and a reference signal. A typical study is comprised of repeated acquisition of backscattered waves from a specimen that is changing slowing with acquisition time or location. The sensitivity of repeated experimental observations of such a slowly changing quantity may be defined as the mean variation (i.e., observed change) divided by mean variance (i.e., observed noise). We compute the sensitivity for joint entropy and signal energy measurements assuming that noise is Gaussian and using Wiener integration to compute the required mean values and variances. These can be written as solutions to the Heat equation, which permits estimation of their magnitudes. There always exists a reference such that joint entropy has larger variation and smaller variance than the corresponding quantities for signal energy, matching observations of several studies. Moreover, a general prescription for finding an “optimal” reference for the joint entropy emerges, which also has been validated in several studies.

Entropy↗