Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Head related transfer function pseudo-stereophony

An apparatus for producing pseudo-stereophonic sound from a monaural signal is discussed. The apparatus includes a monaural source that has a speaker placed in an anechoic room and has a sound output generated by the monaural signal. The second, third, fourth, and fifth speakers are placed in the anechoic room symmetrically about a listener. The monaural signal from the source is processed to output processed signals to each of the second, third, fourth, and fifth speakers, each speaker producing a sound output corresponding to the received processed signal. A pair of microphones is placed in the ears of the listener for receiving the sound outputs of the first, second, third, fourth, and fifth speakers and producing two differentiated audio channels.

Begault, Durand R.↗

Knee-Joint Proprioception During 30-Day 6 deg Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

To determine if daily isotonic exercise or isokinetic exercise training coupled with daily log proprioceptive training, would influence log proprioceptive tracking responses during Bed Rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a NO-Exercise (NOE) training control group (n = 5), and IsoTanic Exercise (ITE, n = 7) and IsoKinetic Exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min period / d, 5 d /week. Only the IKE group performed proprioceptive training using a now isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pro-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p less than 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9 +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.50, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both lsotonic exercise training (without additional propriaceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

Bernauer, E. M.↗

Lower Extremity Muscle Thickness During 30-Day 6 degrees Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

Muscle thickness was measured in 19 Bed-Rested (BR) men (32-42 year) subjected to IsoTonic (ITE, cycle orgometer) and IsoKi- netic (IKE, torque orgometer) lower extremity exercise training, and NO Exercise (NOE) training. Thickness was measured with ultrasonography in anterior thigh-Rectus Femoris (RF) and Vastus Intermadius (VI), and combined posterior log-soleus, flexor ballucis longus, and tibialis posterior (S + FHL +TP) - muscles. Compared with ambulatory control values, thickness of the (S + FHL + TP) decreased by 90%-12% (p less than 0.05) In all three test groups. The (RF) thickness was unchanged in the two exercise groups, but decreased by 10% (p less than 0.05) in the NOE. The (VI) thickness was unchanged In the ITE group, but decreased by 12%-l6% (p less than 0.05) in the IKE and NOE groups. Thus, intensive, alternating, isotonic cycle ergometer exercise training is as effective as intensive, intermittent, isokinetic exercise training for maintaining thicknesses of rectus femoris and vastus lntermedius anterior thigh muscles, but not posterior log muscles, during prolonged BR deconditioning.

Ellis, S.↗

Isokinetic Strength and Endurance During 30-day 6 deg Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle orgometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.

Greenleaf, J. E.↗

Mars Rover Navigation Results Using Sun Sensor Heading Determination

Upcoming missions to the surface of Mars will use mobile robots to traverse long distances from the landing site. To prepare for these missions, the prototype rover, Rocky 7, has been tested in desert field trials conducted with a team of planetary scientists. While several new capabilities have been demonstrated, foremost among these was sun-sensor based traversal of natural terrain totaling a distance of one kilometer. This paper describes navigation results obtained in the field tests, where cross-track error was only 6% of distance traveled. Comparison with previous results of other planetary rover systems shows this to be a significant improvement.

Volpe, Richard↗

Submaximal Exercise VO2 and Q During 30-Day 6 degree Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

Submaximal exercise (61+3% peak VO2) metabolism was measured before (AC day-2) and on bed rest day 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N=5) control, and isotonic exercise (ITE, N=7)and isokinetic exercise (IKE, N=7) training groups. Training was conducting supine for two 30-min periods/d for 6 d/wk: ITE was 60-90% peak VO2: IKE was peak knee flexion-extension at 100 deg/s. Supine submaximal exercise 102 decreased significantly (*p<0.05) by 10.3%, with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output (Q) change of -14.5%* (ITE) and -203%* (IKE), but different from change in peak VO2 (+1.4% with ITE and - 10.2%, with IKE) and plasma volume of -3.7% (ITE) and - 18.0% * (IKE). Thus, reduction of submaximal V02 during prolonged bed rest appears to respond to submaximal Q but is not related to change in peak VO2 or plasma volume.

Greenleaf, J. E.↗

Long-Term Durability Analysis of a 100,000+ Hr Stirling Power Convertor Heater Head

DOE and NASA have identified Stirling Radioisotope Power Systems (SRPS) as the power supply for deep space exploration missions the Europa Orbiter and Solar Probe. As a part of this effort, NASA has initiated a long-term durability project for critical hot section components of the Stirling power convertor to qualify flight hardware. This project will develop a life prediction methodology that utilizes short-term (t < 20,000 hr) test data to verify long-term (t > 100,000 hr) design life. The project consists of generating a materials database for the specific heat of alloy, evaluation of critical hermetic sealed joints, life model characterization, and model verification. This paper will describe the qualification methodology being developed and provide a status for this effort.

Bartolotta, Paul A.↗

High Head Unshrouded Impeller Pump Stage Technology

A team of engineers at NASA/MSFC and Boeing, Rocketdyne division, are developing unshrouded impeller technologies that will increase payload and decrease cost of future reusable launch vehicles. Using the latest analytical techniques and experimental data, a two-stage unshrouded fuel pump is being designed that will meet the performance requirements of a three-stage shrouded pump. Benefits of the new pump include lower manufacturing costs, reduced weight, and increased payload to orbit.

Williams, Robert W.↗

Distance Perception of Stereoscopically Presented Virtual Objects Optically Superimposed on Physical Objects by a Head-Mounted See-Through Display

The influence of physically presented background stimuli on the perceived depth of optically overlaid, stereoscopic virtual images has been studied using headmounted stereoscopic, virtual image displays. These displays allow presentation of physically unrealizable stimulus combinations. Positioning of an opaque physical object either at the initial perceived depth of the virtual image or at a position substantially in front of the virtual image, causes the virtual image to perceptually move closer to the observer. In the case of objects positioned substantially in front of the virtual image, subjects often perceive the opaque object to become transparent. Evidence is presented that the apparent change of position caused by interposition of the physical object is not due to occlusion cues. According, it may have an alternative cause such as variation in the binocular vengeance position of the eyes caused by introduction of the physical object. This effect may complicate design of overlaid virtual image displays for near objects and appears to be related to the relative conspicuousness of the overlaid virtual image and the background. Consequently, it may be related to earlier analyses of John Foley which modeled open-loop pointing errors to stereoscopically presented points of light in terms of errors in determination of a reference point for interpretation of observed retinal disparities. Implications for the design of see-through displays for manufacturing will be discussed.

Ellis, Stephen R.↗

The Second Generation High Speed Rotor Head Mounted Instrumentation System

NASA Ames Research Center has been investigating the air pressure flow of a rotor blade on a UH-60 Black Hawk helicopter in-flight. This paper will address the changes and improvements due to additional restrictions and requirements for the instrumentation system. The second generation instrumentation system was substantially larger and this allowed greatly improved accessibility to the components for ease of maintenance as well as improved gain and offset adjustment capabilities and better filtering.

Lewis, John↗

Headphone and Head-Mounted Visual Displays for Virtual Environments

A realistic auditory environment can contribute to both the overall subjective sense of presence in a virtual display, and to a quantitative metric predicting human performance. Here, the role of audio in a virtual display and the importance of auditory-visual interaction are examined. Conjectures are proposed regarding the effectiveness of audio compared to visual information for creating a sensation of immersion, the frame of reference within a virtual display, and the compensation of visual fidelity by supplying auditory information. Future areas of research are outlined for improving simulations of virtual visual and acoustic spaces. This paper will describe some of the intersensory phenomena that arise during operator interaction within combined visual and auditory virtual environments. Conjectures regarding audio-visual interaction will be proposed.

Begault, Duran R.↗

Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt

Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.

Ertl, A. C.↗

A Head Start to a Healthy Heart

Cambridge Heart, Inc., has licensed the only U.S. Food and Drug Administration-cleared tool to identify those at risk for sudden cardiac death (SCD). The Microvolt T-Wave Alternans Test(TM) was invented by Dr. Richard J. Cohen, a professor at the Harvard-Massachusetts Institute of Technology (MIT) Division of Health Sciences and Technology, with developmental support and funding from NASA's Johnson Space Center and the National Space Biomedical Research Institute (NSBRI) in Houston, Texas. In 1993, MIT licensed the technology to Cambridge Heart, Inc., a start-up company that Dr. Cohen helped to establish. Cambridge Heart's non-invasive technology measures T-wave alternans, a change from one heartbeat to the next that is too minute to be detected by a standard electrocardiogram. Cardiac patients with such a change in heartbeat regulation are faced with a much greater risk of ventricular arrhythmia and SCD than those without it. The company's ability to measure electrical alternans on a microvolt level has been clinically proven to be just as accurate as - and in some studies, more accurate than - more costly and somewhat risky, invasive procedures, such as electrophysiological testing.

Source record↗

Neural crest contributions to the lamprey head

The neural crest is a vertebrate-specific cell population that contributes to the facial skeleton and other derivatives. We have performed focal DiI injection into the cranial neural tube of the developing lamprey in order to follow the migratory pathways of discrete groups of cells from origin to destination and to compare neural crest migratory pathways in a basal vertebrate to those of gnathostomes. The results show that the general pathways of cranial neural crest migration are conserved throughout the vertebrates, with cells migrating in streams analogous to the mandibular and hyoid streams. Caudal branchial neural crest cells migrate ventrally as a sheet of cells from the hindbrain and super-pharyngeal region of the neural tube and form a cylinder surrounding a core of mesoderm in each pharyngeal arch, similar to that seen in zebrafish and axolotl. In addition to these similarities, we also uncovered important differences. Migration into the presumptive caudal branchial arches of the lamprey involves both rostral and caudal movements of neural crest cells that have not been described in gnathostomes, suggesting that barriers that constrain rostrocaudal movement of cranial neural crest cells may have arisen after the agnathan/gnathostome split. Accordingly, neural crest cells from a single axial level contributed to multiple arches and there was extensive mixing between populations. There was no apparent filling of neural crest derivatives in a ventral-to-dorsal order, as has been observed in higher vertebrates, nor did we find evidence of a neural crest contribution to cranial sensory ganglia. These results suggest that migratory constraints and additional neural crest derivatives arose later in gnathostome evolution.

Non-NASA Center↗

Contribution of perfusion pressure to vascular resistance response during head-up tilt

We measured brachial and femoral artery flow velocity in eight subjects and peroneal and median muscle sympathetic nerve activity (MSNA) in five subjects during tilt testing to 40 degrees. Tilt caused similar increases in MSNA in the peroneal and median nerves. Tilt caused a fall in femoral artery flow velocity, whereas no changes in flow velocity were seen in the brachial artery. Moreover, with tilt, the increase in the vascular resistance employed (blood pressure/flow velocity) was greater and more sustained in the leg than in the arm. The ratio of the percent increase in vascular resistance in leg to arm was 2.5:1. We suggest that the greater vascular resistance effects in the leg were due to an interaction between sympathetic nerve activity and the myogenic response.

NASA Discipline Cardiopulmonary↗

Effect of field size, head motion, and rotational velocity on roll vection and illusory self-tilt in a tumbling room

The effect of field size, velocity, and visual fixation upon the perception of self-body rotation and tilt was examined in a rotating furnished room. Subjects sat in a stationary chair in the furnished room which could be rotated about the body roll axis. For full-field conditions, complete 360 degrees body rotation (tumbling) was the most common sensation (felt by 80% of subjects). Constant tilt or partial tumbling (less than 360 degrees rotation) occurred more frequently with a small field of view (20 deg). The number of subjects who experienced complete tumbling increased with increases in field of view and room velocity (for velocities between 15 and 30 degrees s-1). The speed of perceived self-rotation relative to room rotation also increased with increasing field of view.

Non-NASA Center↗

Isokinetic strength and endurance during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training

The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle ergometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.

Bed Rest↗