A high resolution echelle spectrometer for soft X-ray and EUV astronomy

A new design is presented for high resolution spectroscopy from 80 to 400 A. This design employs grazing incidence optics and variable line-spaced gratings to achieve high resolution. Unlike some previously proposed EUV echelles, this design employs straight groove planar gratings, which are a well-proven, easily manufactured design. The instrument delivers a peak resolution of 7500 and a peak effective area of 3 sq cm.

Green, James↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

A Cassegrain echelle spectrograph

The 'LPL echelle' is a CCD spectrograph with a resolving power of 160,000 and enough sensitivity to detect the brighter airglow emissions in a few minutes. It uses an R3.2 grating in a novel out-of-plane mounting that permits any wavelength to be placed on the blaze. A single order is selected by a medium-band interference filter. Lower dispersions and broader wavelength coverage are obtained by replacing the echelle by a 600 line/mm grating or a Littrow prism.

Hunten, D. M.↗

Reconfigurable optical interconnection network for multimode optical fiber sensor arrays

A single-source, single-detector architecture has been developed to implement a reconfigurable optical interconnection network multimode optical fiber sensor arrays. The network was realized by integrating LiNbO3 electrooptic (EO) gratings working at the Raman Na regime and a massive fan-out waveguide hologram (WH) working at the Bragg regime onto a multimode glass waveguide. The glass waveguide utilized the whole substrate as a guiding medium. A 1-to-59 massive waveguide fan-out was demonstrated using a WH operating at 514 nm. Measured diffraction efficiency of 59 percent was experimentally confirmed. Reconfigurability of the interconnection was carried out by generating an EO grating through an externally applied electric field. Unlike conventional single-mode integrated optical devices, the guided mode demonstrated has an azimuthal symmetry in mode profile which is the same as that of a fiber mode.

Chen, R. T.↗

The MIT high resolution X-ray spectroscopy instruments on AXAF

The general design and performance characteristics of MIT's two dispersive spectrometers, the Bragg Crystal Spectrometer (BCS) and the High Energy Transmission Grating Spectrometer (HETG), now being developed for the Advanced X-ray Astrophysics Facility (AXAF), are described. Particular attention is given to the development of the critical technologies incorporated into these instruments, including BCS diffractors, imaging gas flow proportional counters, and grating elements for the HETG. The principal stages and the current status of the developments are reviewed.

Canizares, C. R.↗

The potential for plasma diagnostics from stellar extreme-ultraviolet observations

A description of the lines from the most abundant ions in the EUV spectrum in the range 50-500 A that have special diagnostic significance is presented. These lines are from plasmas in the temperature range from 10 exp 5 to 10 exp 7 K. Their utility for determining temperature, density, and abundances is demonstrated. An objective grating spectrometer, based on the Skylab slitless spectrograph, for making celestial observations in the EUV spectral region with high spectral resolution is also described. Such an instrument, if equipped with a multilayer grating, can achieve efficiencies over limited EUV wavelength ranges that rival much larger telescope-spectrometer instruments for the observation of stars and other celestial objects.

Feldman, U.↗

Design concept for an IR mapping spectrometer for the Pluto fast flyby mission

The design of an IR mapping spectrometer that exceeds all the criteria of the Pluto Fast Flyby Mission will be presented. The instrument has a mass of approximately 1700 g and uses less than 4 W of power. The design concept is based on an f/3 spectrograph using an aberration-corrected concave holographic grating. Up to four spectral regions can be covered simultaneously by dividing the grating into two to four sections, each imaging the entrance slit on a different area of the array. The spectrography will be fed by a lightweight 5 in. f/3 telescope based on SDIO precepts. In order to provide spectroscopic access to the fundamental molecule frequencies, an extended-range NICMOS array to approximately 3.5 microns and an InSb array going to 5.8 microns will be considered.

Fink, U.↗

Variable sensitivity moire interferometry

This paper demonstrates that optical microlithography can be used to produce a crossed grating which diffracts light into multiple orders sufficient to record moire interferograms with sensitivities ranging from 2.0 to 0.285 micron/fringe. The grating profile produced by the method is analyzed to establish the diffraction efficiency in each diffraction order, and generalized expressions are given for variable sensitivity moire interferometry. Experimental tests are conducted to verify analytical arguments. In one of these tests, two different diffraction order pairs are used simultaneously to verify that surface displacement can be measured at different sensitivities.

Johnson-Cole, Helen↗

Multiple frequency interference in photorefractive media

The paper describes the use of a numerical simulation to predict the dynamic behavior of a photorefractive crystal exposed to interfering light waves at two different frequencies. Unlike static recording media, photorefractive materials allow for the simultaneous diffraction from and generation of refractive index gratings. The grating properties are evaluated in terms of their effect on the performance of a dynamic distributed sensor which uses the crystal as a holographic recording medium. Experimental results are presented which support the behavior predicted by simulation.

Cox, David E.↗

Monochromatic imaging instrumentation for applications in aeronomy of the earth and planets

Monochromatic imaging instrumentation has been developed that uses narrow-band (12 A FWHP) interference filters or plane reflection gratings for 2D imaging and imaging spectrograph applications. By changing the optics in front of the filter or grating, the field of view of the instruments can be varied from 180 deg to 6 deg. In the case of the 2D monochromatic imager, the 12 mm-diameter filtered image is formed at about f/1 on the input photocathode of an intensified CCD camera (380 x 488 pixels). The sensitivities of the systems are about 50-100 R s (S/N about 2). Examples of data taken with both of these instruments include detection and mapping of Jupiter's sodium magnetonebula and stable auroral red arcs in the terrestrial ionosphere.

Baumgardner, Jeffrey↗

Instrument design and test results of the new all-reflection spatial heterodyne spectrometer

An all-reflection spatial heterodyne spectrometer (SHS) has been recently developed. The advantages over conventional high-resolution grating spectrometers are that the SHS requires no mechanical scanning, a self-compensating optical design permits easy alignment, and it is much smaller than other spectrometers of comparable resolution. Since all beam-splits and recombinations occur by reflection off of a diffraction grating, the interferometer is capable of operating well into the extreme ultraviolet (EUV) and possibly into the soft X-ray region. A description of the design and the characteristics of the instrument is presented. Also, test results, including sample interferograms as well as their Fourier-transformed spectra, at both visible and UV wavelengths are shown. Finally, we report on future developments and possible applications.

Bush, Brett C.↗

Directivity versus element spacing for a scanning array

The results of the present examination of the relationship of directivity with element spacings of linear, rectangular, and hexagonal arrays indicate that element spacings for optimal directivity vary with scan angles; this is especially true in the case of changes in aperture sizes and the appearance of grating lobes in the visible space. Grating lobe effects are more pronounced for isotropic than for directive element arrays. Directivity decreases as the beam scans off from boresight, and rapidly diminishes for scans over 30 deg. The hexagonal array has higher directivity for scans of less than 20 deg, and the linear array for those over 30 deg.

Zimmerman, M.↗

Scattered light in the echelle modes of the Goddard High Resolution Spectrograph aboard the Hubble Space Telescope. II - Analysis of in-flight spectroscopic observations

We report on an analysis of observations made with the GHRS aboard the HST for the purpose of calibrating the effects of scattered light. The data were obtained during the first 2 years of flight operations as part of the Science Verification, Science Assessment Observations, and Guaranteed Time Observations programs. Both the general level of background light near the spectra and the filling-in of the cores of saturated interstellar absorption lines have been determined as functions of grating, order, wavelength, and aperture. The behavior is in accordance with our detailed analysis of prelaunch laboratory data and validates both the observing procedures and the data reduction developed on the basis of that experience. We present and discuss the use of a background (scattered light) removal algorithm designed to produce net spectra properly corrected for the effects of grating scattered light. The coefficients of the scattered light removal algorithm have been determined, and recommended numerical values are presented.

Cardelli, Jason A.↗

A comparative evaluation of in-plane shear test methods for laminated graphite-epoxy composites

The objectives were to evaluate popular shear test methods for various forms of graphite-epoxy composite materials and to determine the shear response of graphite-epoxy composites with various forms of fiber architecture. Numerical and full-field experimental stress analyses were performed on four shear test configurations for unidirectional and bidirectional graphite-epoxy laminates to assess the uniformity and purity of the shear stress (strain) fields produced in the specimen test section and to determine the material in-plane shear modulus and shear response. The test methods were the 10 deg off-axis, the +/- 45 deg tension, the Iosipescu V-notch, and a compact U-notch specimen. Specimens were prepared from AS4/3501-6 graphite-epoxy panels, instrumented with conventional strain gage rosettes and with a cross-line moire grating, and loaded in a convenient testing machine. The shear responses obtained for each test method and the two methods of specimen instrumentation were compared. In a second phase of the program the shear responses obtained from Iosipescu V-notch beam specimens were determined for woven fabric geometries of different weave and fiber architectures. Again the responses of specimens obtained from strain gage rosettes and moire interferometry were compared. Additional experiments were performed on a bidirectional cruciform specimen which was also instrumented with strain gages and a moire grating.

Morton, John↗

The ISO SWS on-line system

The software which is currently being developed for the Short Wavelength Spectrometer (SWS) of the Infrared Space Observatory (ISO) is described. The spectrometer has a wide range of capabilities in the 2-45 micron infrared band. SWS contains two independent gratings, one for the long and one for the short wavelength section of the band. With the gratings a spectral resolution of approximately 1000 to approximately 2500 can be obtained. The instrument also contains two Fabry-Perault's yielding a resolution between approximately 1000 and approximately 20000. Software is currently being developed for the acquisition, calibration, and analysis of SWS data. The software is firstly required to run in a pipeline mode without human interaction, to process data as they are received from the telescope. However, both for testing and calibration of the instrument as well as for evaluation of the planned operating procedures the software should also be suitable for interactive use. Thirdly the same software will be used for long term characterization of the instrument. The software must work properly within the environment designed by the European Space Agency (ESA) for the spacecraft operations. As a result strict constraints are put on I/O devices, throughput etc.

Roelfsema, P. R.↗

Planetary Instrument Definition and Development Program (PIDDP). Instrument for future planetary flight missions: A visible-infrared imaging spectrometer for planetary missions

The objective of this project is to develop and prove a small, light-weight, efficient imaging spectrometer design to cover the VIS/NIR spectral range for applications particularly but not exclusively to NASA inner solar system space missions. A design and a brassboard prototype will be developed and tested. Progress over the first year of this project includes design specification, optical design layout, grating specifications, infrared detector selection, and mechanical design. Mechanical and grating manufacturing drawings were begun. We developed an agreement in principle to cooperate with the German space group, DLR, to apply some of their electronics microminiaturization technology to this imaging spectrometer project, mostly or entirely at their expense. Funds from NASA for the second year of this effort have been received and the effort is on track. Release of funds for the third year of this award will be requested later this year in order to accelerate this work and bring it to a conclusion in time for new NASA missions considerations as well as to make effective use of the DLR contributions.

Mccord, Thomas B.↗

Inter-comparison of Wildfire and High-resolution Interferometer Sounder (HIS) data from STORM-FEST: An investigation of wildfire spectral channel discrepancies

This simultaneous collection of HIS spectral measurements aboard the ER-2 during STORM-FEST provided a means to explore calibration problems in the infrared bands of the Wildfire instrument. Large discrepancies in brightness temperatures were noted in Wildfire bands designed to sample the 'wings' of the strong ozone absorption band centered at 9.6 microns, where the atmospheric transmittance changes rapidly with wavelength. Examination of interchannel relationships in Wildfire data and subsequent comparison to Wildfire data synthesized from the HIS measurements suggests that a wavelength shift in the channel spectral response from those determined in the laboratory may have occurred. Based on comparisons from several flights, this spectral shift has been empirically determined to be about 0.15 micron. It is speculated that this problem resulted from a slight misalignment of the spectrometer grating or other optical elements, or was a result of extreme range in temperatures experienced by the instrument throughout the course of an ER-2 flight. A consequence of this temperature fluctuation may be a change in a position of the grating in the optical path and could result in the variations in channel spectral response during flight. These findings for Wildfire may have significant bearing on future use of the MAS because of the similarities to the original Wildfire configuration.

Jedlovec, G. J.↗

High resolution visible to short-wave near-infrared CCD spectra of Mars during 1990

The 0.4 to 1.0 micron spectrum of Mars is dominated by a steep red, relatively featureless spectral slope. Earlier lower spectral observations interpreted the red color and the lack of absorption features in the spectra as evidence of poorly crystalline ferric oxide minerals. More recent higher spectral resolution observations and reinterpretations of older data sets have revealed measureable spectral structure, however. For example, absorption features near 0.65 and 0.86 micron were detected and spatially mapped in data obtained during the 1988 opposition. These absorptions were interpreted as evidence for crystalline hematite on Mars, occuring as an accessory phase in abundances of 3 to 6 percent in the soil. We are attempting to verify the existence of these subtle crystalline Fe(3+) absorption features and to map their spatial distribution in regions of the planet not imaged in 1988. During the 1990 opposition, we obtained imaging spectroscopic data of Mars from the University of Hawaii 2.24 m telescope at Mauna Kea Observatory. The data were obtained with the Wide Field Grism Spectrograph (WFGS), which uses an 800 x 800 CCD and a transmission grating ruled on a prism. We used a grating blazed at 4800 A in first order to obtain data from 0.50 to 0.94 micron at a spectral resolution of R = 200 to 350. The moon/Mars slit design used had projected dimensions of 0.29 x 153 inches, allowing for high spectral resolution and adequate cross-slit spatial sampling of the Martian disk.

Bell, James F., III↗