Exploration of Failure and Potential Damage Markers in Ti-6Al-4V

To improve prognostics for predicting component life, coupon tests were conducted on Ti-6Al-4V to investigate the development of damage. Various test types were employed (tension, creep, stress relaxation, and fatigue) under a wide range of temperatures and loading rates to engage various amounts of time-dependent and damage behavior. Both stiffness degradation and Poisson’s ratio were monitored to see if they were useful in indicating the initiation and accumulation of damage and subsequently the onset of failure. Stiffness exhibited large decreases with increasing strain when calculated using engineering stress and strain. However, minimal stiffness change was observed when using the true-stress and true- strain values. Detailed microscopy and image analysis were performed to document the actual physical damage that occurred within the various specimens. Two types of damage were observed: shallow surface cracks and internal pores. The severity of damage was greater in the region of localized necking and diminished further away from the neck. The area fraction of pores was higher in the necked region, yet even there it did not exceed more than a few percent and, in most cases, was significantly lower. It was observed that conditions that induced more time-dependent deformation (e.g., slower strain rate testing) resulted in a larger number of pores and larger pore sizes. The pores were always found to occur in the softer β-phase. The severity of observed damage was inconsistent with the large drop in engineering stiffness, but was more aligned with stiffness changes from the true-stress and -strain values. Poisson’s ratio was monitored on every test and showed promise as a damage indicator. It was found to be more sensitive than either the ultimate tensile strength or the inception of tertiary creep. However, calculation of Poisson’s ratio was found to be more involved than expected because of anisotropy and the presence of strain gradients along the specimen at large applied strains. First, the material had a moderate texture and resulted in anisotropy of the strains. Second, the evolution of Poisson’s ratio as a function of axial strain showed strange and unexpected behaviors, which necessitated more extensive analyses of its development. This led to an investigation on the use of small versus large strain approaches and the importance of making consistent measurements; that is, axial and transverse strain measurements over the same volume of material. Additionally, finite element analysis of a tensile sample indicated that non- uniform strain occurred in the sample prior to attaining the maximum strength. This, along with the location at which transverse strain was measured, had a significant influence on the resulting values of Poisson’s ratio. Based on this, lessons learned are offered for future testing.

Ti-6Al-4V↗

Damage mechanisms in bithermal and thermomechanical fatigue of Haynes 188

Post failure fractographic and metallographic studies were conducted on Haynes 188 specimens fatigued under bithermal and thermomechanical loading conditions between 316 and 760 C. Bithermal fatigue specimens examined included those tested under high strain rate in-phase and out-phase, tensile creep in-phase, and compressive creep out-of-phase loading conditions. Specimens tested under in-phase and out-of-phase thermomechanical fatigue were also examined. The nature of failure mode (transgrandular versus intergranular), the topography of the fracture surface, and the roles of oxidation and metallurgical changes were studied for each type of bithermal and thermomechanical test.

Kalluri, Sreeramesh↗

Assessing photovoltaic module degradation and lifetime from long term environmental tests

The photovoltaic module failure mechanisms related to temperature, humidity, and electrical bias are analyzed using the data collected over a period of 20 years from various sites in the U.S. The approach is based on measuring the rate dependence of the mechanisms on site stress levels, and then using the rate data to analytically estimate the field life by means of computer models of the site environment. A correlation is established between the accelerated constant-stress testing and the time-varying field exposures. Test results are presented for two failure mechanisms for a module design featuring polyvinyl butyral encapsulant for the temperature range of 85 to 100 C and 85-percent relative humidity.

Otth, D. H.↗

Space Shuttle reaction control system thruster metal nitrate removal and characterization

The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.

Saulsberry, R. L.↗

Patterns of brittle deformation under extension on Venus

The development of fractures at regular length scales is a widespread feature of Venusian tectonics. Models of lithospheric deformation under extension based on non-Newtonian viscous flow and brittle-plastic flow develop localized failure at preferred wavelengths that depend on lithospheric thickness and stratification. The characteristic wavelengths seen in rift zones and tessera can therefore provide constraints on crustal and thermal structure. Analytic solutions were obtained for growth rates in infinitesimal perturbations imposed on a one-dimensional, layered rheology. Brittle layers were approximated by perfectly-plastic, uniform strength, overlying ductile layers exhibiting thermally-activated power-law creep. This study investigates the formation of faults under finite amounts of extension, employing a finite-element approach. Our model incorporates non-linear viscous rheology and a Coulomb failure envelope. An initial perturbation in crustal thickness gives rise to necking instabilities. A small amount of velocity weakening serves to localize deformation into planar regions of high strain rate. Such planes are analogous to normal faults seen in terrestrial rift zones. These 'faults' evolve to low angle under finite extension. Fault spacing, orientation and location, and the depth to the brittle-ductile transition, depend in a complex way on lateral variations in crustal thickness. In general, we find that multiple wavelengths of deformation can arise from the interaction of crustal and mantle lithosphere.

Neumann, G. A.↗

Identification and Reconfigurable Control of Impaired Multi-Rotor Drones

The paper presents an algorithm for control and safe landing of impaired multi-rotor drones when one or more motors fail simultaneously or in any sequence. It includes three main components: an identification block, a reconfigurable control block, and a decisions making block. The identification block monitors each motor load characteristics and the current drawn, based on which the failures are detected. The control block generates the required total thrust and three axis torques for the altitude, horizontal position and/or orientation control of the drone based on the time scale separation and nonlinear dynamic inversion. The horizontal displacement is controlled by modulating the roll and pitch angles. The decision making algorithm maps the total thrust and three torques into the individual motor thrusts based on the information provided by the identification block. The drone continues the mission execution as long as the number of functioning motors provide controllability of it. Otherwise, the controller is switched to the safe mode, which gives up the yaw control, commands a safe landing spot and descent rate while maintaining the horizontal attitude.

Unmanned aerial system↗

High strain rate properties of angle-ply composite laminates, part 3

Angle-ply graphite/epoxy and graphite/S-glass/epoxy laminates were characterized in uniaxial tension at strain rates ranging from quasi-static to over 500 s(sup -1). Laminate ring specimens of +/-15(sub 2s), +/-22.5(sub 2s), +/-30(sub 2s), +/-45(sub 2s), +/-60(sub 2s), +/-67.5(sub 2s), and +/-75(sub 2s) degree layups were loaded under internal pressure. Results were presented in the form of stress-strain curves to failure. Properties determined included moduli, Poisson's ratios, strength, and ultimate strain. In all seven laminates for the two materials tested the modulus and strength increase with strain rate. The effect of strain rate varies with layup, being lowest for the fiber dominated +/-15(sub 2s) degree laminates and highest for the matrix dominated +/-75(sub 2s) degree laminates. The highest increments over the static values are 10 to 25 percent for the +/-15(sub 2s) degree layup and 200 to 275 percent for the +/-75(sub 2s) degree layup. Ultimate strains do not show any significant trends with strain rate. In almost all cases the ultimate strain values are within +/-20 percent of the mean value and in half of the cases the deviation from the mean are less than 10 percent.

Daniel, I. M.↗

Current Emergency Locator Transmitter (ELT) deficiencies and potential improvements utilizing TSO-C91a ELTs

An analysis was conducted of current ELT problems and potential improvements that could be made by employing the TSO-C91a ELTs to replace the current TSO-C91 ELTs. The scope of the study included the following: (1) validate the problems; (2) determine specific failure causes; (3) determine false alarm causes; (4) estimate improvements from TSO-C91a; (5) estimate benefits from replacement of the current ELTs; and (6) determine need and benefits for improved ELT inspection and maintenance. A detailed comparison between the two requirements documents (TSO-C91 and -91a) was made to assess improved performance of the ELT in each category of failure cause and each cause of false alarms. The comparison and analysis resulted in projecting a success of operation rate approximately 3 times the current rate and a reduction in false alarms to 0.25 of those generated by TSO-C91 ELTs. These improvements led to a projection of benefits of approximately 25 additional lives to be saved each year with TSO-C91a ELTs and an improved inspection and maintenance program.

Trudell, Bernard J.↗

Reliable magnetic tape recording for real-time data acquisition systems

The design of a real-time magnetic tape I/O system using automatic error recovery and data spooling is discussed. Real time requirements (data acquired at one rate and recorded at another by queing) must be met and data integrity must be provided regardless of tape failures or I/O errors. Automatic blocking services should be used for multiple local records storage. Avoidance of operational delays and loss of data is essential, noting the problems of the tape drives of the NASA Langley cryogenic wind tunnel. A series of block diagrames and flow charts are included.

Richard W Ross↗

A creep cavity growth model for creep-fatigue life prediction of a unidirectional W/Cu composite

A microstructural model was developed to predict creep-fatigue life in a (0)(sub 4), 9 volume percent tungsten fiber-reinforced copper matrix composite at the temperature of 833 K. The mechanism of failure of the composite is assumed to be governed by the growth of quasi-equilibrium cavities in the copper matrix of the composite, based on the microscopically observed failure mechanisms. The methodology uses a cavity growth model developed for prediction of creep fracture. Instantaneous values of strain rate and stress in the copper matrix during fatigue cycles were calculated and incorporated in the model to predict cyclic life. The stress in the copper matrix was determined by use of a simple two-bar model for the fiber and matrix during cyclic loading. The model successfully predicted the composite creep-fatigue life under tension-tension cyclic loading through the use of this instantaneous matrix stress level. Inclusion of additional mechanisms such as cavity nucleation, grain boundary sliding, and the effect of fibers on matrix-stress level would result in more generalized predictions of creep-fatigue life.

Kim, Young-Suk↗

Motor Brush Testing for Mars and Vacuum

Brush motors have been qualified and flown successfully on Mars missions, but upcoming missions require longer life and higher power. A test program was therefore undertaken to identify the best brush material for operation in the Mars atmosphere. Six different brush materials were used in 18 identical motors and operated under various load conditions for a period of four weeks in low-pressure CO2. All motors performed acceptably, with accumulated motor revolutions between 98 and 144 million revolutions, depending on load. A proprietary silver-graphite material from Superior Carbon (SG54-27) appears to be the best choice for long life, but even the stock copper-graphite brushes performed reliably with acceptable wear. The motors from the CO2 test were then cleaned and run in vacuum for 2 weeks. The difference in results was dramatic, with 5 motors failing catastrophically and wear rates increasing by orders of magnitude for the SG54-27 material. Three brush materials survived the test with no failures: SG54-27 with a proprietary Ball Aerospace impregnation, a silver-graphite-molybdenum disulfide material from Superior Carbon (SG59), and a copper sulfide-graphite material also from Superior Carbon (BG91).

Noon, Don E.↗

SRAM Based Re-programmable FPGA for Space Applications

An SRAM (static random access memory)-based reprogrammable FPGA (field programmable gate array) is investigated for space applications. A new commercial prototype, named the RS family, was used as an example for the investigation. The device is fabricated in a 0.25 micrometers CMOS technology. Its architecture is reviewed to provide a better understanding of the impact of single event upset (SEU) on the device during operation. The SEU effect of different memories available on the device is evaluated. Heavy ion test data and SPICE simulations are used integrally to extract the threshold LET (linear energy transfer). Together with the saturation cross-section measurement from the layout, a rate prediction is done on each memory type. The SEU in the configuration SRAM is identified as the dominant failure mode and is discussed in detail. The single event transient error in combinational logic is also investigated and simulated by SPICE. SEU mitigation by hardening the memories and employing EDAC (error detection and correction) at the device level are presented. For the configuration SRAM (CSRAM) cell, the trade-off between resistor de-coupling and redundancy hardening techniques are investigated with interesting results. Preliminary heavy ion test data show no sign of SEL (single event latch-up). With regard to ionizing radiation effects, the increase in static leakage current (static I(sub CC)) measured indicates a device tolerance of approximately 50krad(Si).

Wang, J. J.↗

Analysis of Aircraft Control Performance using a Fuzzy Rule Base Representation of the Cooper-Harper Aircraft Handling Quality Rating

The Cooper-Harper rating of Aircraft Handling Qualities has been adopted as a standard for measuring the performance of aircraft since it was introduced in 1966. Aircraft performance, ability to control the aircraft, and the degree of pilot compensation needed are three major key factors used in deciding the aircraft handling qualities in the Cooper- Harper rating. We formulate the Cooper-Harper rating scheme as a fuzzy rule-based system and use it to analyze the effectiveness of the aircraft controller. The automatic estimate of the system-level handling quality provides valuable up-to-date information for diagnostics and vehicle health management. Analyzing the performance of a controller requires a set of concise design requirements and performance criteria. Ir, the case of control systems fm a piloted aircraft, generally applicable quantitative design criteria are difficult to obtain. The reason for this is that the ultimate evaluation of a human-operated control system is necessarily subjective and, with aircraft, the pilot evaluates the aircraft in different ways depending on the type of the aircraft and the phase of flight. In most aerospace applications (e.g., for flight control systems), performance assessment is carried out in terms of handling qualities. Handling qualities may be defined as those dynamic and static properties of a vehicle that permit the pilot to fully exploit its performance in a variety of missions and roles. Traditionally, handling quality is measured using the Cooper-Harper rating and done subjectively by the human pilot. In this work, we have formulated the rules of the Cooper-Harper rating scheme as fuzzy rules with performance, control, and compensation as the antecedents, and pilot rating as the consequent. Appropriate direct measurements on the controller are related to the fuzzy Cooper-Harper rating system: a stability measurement like the rate of change of the cost function can be used as an indicator if the aircraft is under control; the tracking error is a good measurement for performance needed in the rating scheme. Finally, the change of the control amount or the output of a confidence tool, which has been developed by the authors, can be used as an indication of pilot compensation. We use a number of known aircraft flight scenarios with known pilot ratings to calibrate our fuzzy membership functions. These include normal flight conditions and situations in which partial or complete failure of tail, aileron, engine, or throttle occurs.

Tseng, Chris↗

Design and Simulation of a MEMS Structure for Electrophoretic and Dielectrophoretic Separation of Particles by Contactless Electrodes

Rapid identification of pathogenic bacterial species is an important factor in combating public health problems such as E. coli contamination. Food and waterborne pathogens account for sickness in 76 million people annually (CDC). Diarrheagenic E. coli is a major source of gastrointestinal illness. Severe sepsis and Septicemia within the hospital environment are also major problems. 75 1,000 cases annually with a 30-50% mortality rate (Crit Care Med, July '01, Vol. 29, 1303-10). Patient risks run the continuum from fever to organ failure and death. Misdiagnosis or inappropriate treatment increases mortality. There exists a need for rapid screening of samples for identification of pathogenic species (Certain E. coli strains are essential for health). Critical to the identification process is the ability to isolate analytes of interest rapidly. This poster discusses novel devices for the separation of particles on the basis of the dielectric properties, mass and surface charge characteristics is presented. Existing designs involve contact between electrode surfaces and analyte medium resulting in contamination of the electrode bearing elements Two different device designs using different bulk micromachining MEMS processes (PolyMUMPS and a PyrexBIGold electrode design) are presented. These designs cover a range of particle sizes from small molecules through eucaryotic cells. The application of separation of bacteria is discussed in detail. Simulation data for electrostatic and microfluidic characteristics are provided. Detailed design characteristics and physical features of the as fabricated PolyMUMPS design are provided. Analysis of the simulation data relative to the expected performance of the devices will be provided and subsequent conclusions discussed.

Shaw, Harry C.↗

Revisiting the Soyuz-1 Parachute Failure in the Context of Safety in the Modern Era

The Soyuz‑1 accident remains one of the most consequential parachute related failures in human spaceflight history and provides enduring lessons for modern Entry, Descent, and Landing (EDL) system design. Occurring during the height of the Cold War and the Space Race, the mission unfolded under extraordinary political and schedule pressure as the Soviet Union sought to maintain its early leadership in space achievements following the death of chief designer Sergei Korolev. Despite unresolved propulsion, electrical, and parachute system deficiencies, Soyuz‑1 proceeded to launch and immediately encountered critical inflight anomalies, including a failed solar panel deployment, attitude control issues, and communication dropouts. Upon reentry, a malfunction in the parachute system, driven by a primary main canopy that failed to deploy, and subsequent entanglement of the reserve main canopy with the primary drogue parachute, resulted in insufficient deceleration and the fatal crash of cosmonaut Vladimir Komarov. Subsequent investigations revealed deep rooted cultural and organizational issues within the Soviet space program, including inadequate testing, suppression of dissent, undocumented last minute design changes, and the absence of integrated parachute system verification. More than 200 design flaws were identified after the accident, and firsthand accounts, including those from Yuri Gagarin, highlighted widespread concern prior to launch. Over time, the Soviet program implemented substantial reforms: systematic design corrections, rigorous process documentation, and an extensive series of drop tests that ultimately transformed the Soyuz system into one of the world’s most reliable human-rated return vehicles. This paper examines the technical architecture of the Soyuz‑1 parachute system, reconstructs the likely deployment sequence and failure mechanism, and analyzes the cultural contributors that shaped the accident. The study draws parallels to modern spacecraft parachute development, emphasizing the critical importance of integrated system testing, transparent engineering culture, and continuous hardware surveillance. These lessons remain directly relevant to today’s NASA and Commercial Crew Programs (CCP), where the Government continues to refine its understanding of aggregate risk and strengthen overall astronaut safety in the face of increasingly complex parachute systems.

Aaron L Morris↗

A real-time diagnostic and performance monitor for UNIX

There are now over one million UNIX sites and the pace at which new installations are added is steadily increasing. Along with this increase, comes a need to develop simple efficient, effective and adaptable ways of simultaneously collecting real-time diagnostic and performance data. This need exists because distributed systems can give rise to complex failure situations that are often un-identifiable with single-machine diagnostic software. The simultaneous collection of error and performance data is also important for research in failure prediction and error/performance studies. This paper introduces a portable method to concurrently collect real-time diagnostic and performance data on a distributed UNIX system. The combined diagnostic/performance data collection is implemented on a distributed multi-computer system using SUN4's as servers. The approach uses existing UNIX system facilities to gather system dependability information such as error and crash reports. In addition, performance data such as CPU utilization, disk usage, I/O transfer rate and network contention is also collected. In the future, the collected data will be used to identify dependability bottlenecks and to analyze the impact of failures on system performance.

Dong, Hongchao↗

Creep of Uncoated and Cu-Cr Coated NARloy-Z

Stress rupture creep tests were performed on uncoated and Cu-30vol%Cr coated NARloy-Z copper alloy specimens exposed to air at 482 C to 704 C. The results showed that creep failure in air of unprotected NARloy-Z was precipitated by brittle intergranular surface cracking produced by strain assisted grain boundary oxidation (SAGBO) which in turn caused early onset of tertiary creep. For the protected specimens, the Cu-Cr coating remained adherent throughout the tests and was effective in slowing down the rate of oxygen absorption, particularly at the higher temperatures, by formation of a continuous chromium oxide scale. As the result of reducing oxygen ingress, the coating prevented SAGBO initiated early creep failure, extended creep deformation and increased the creep rupture life of NARloy-Z over the entire 482 C to 704 C test temperature range.

Walter, R. J.↗

Usability Evaluation Technical Report: A Usability Evaluation of the Communication Tool Prototype Prepared in Adobe XD for High Density Vertiplex (HDV) Team

Purpose: As cities get more crowded, the roadway infrastructure cannot keep up with the travel demands. Aviation can be a solution. Organizations supporting NASA’s Urban Air Mobility (UAM) concept are conducting studies on feasible concepts of operations for the new air traffic management system required to implement UAM. NASA’s High Density Vertiplex (HDV) team conducts studies using both live flights and simulations. Significance: The goal of this study is to evaluate the effectiveness of a communication tool developed for this team to enhance team situation awareness. Specifically, the study aims to determine if the communication tool is effective in allowing NASA-Langley and NASA-Ames team members playing different roles to understand what others are doing so that completed steps can be communicated to the whole team. Methods: This study asks participants to conduct four distinct scenarios using an Adobe XD prototype. Participants included five members of the target audience, who each received up to 15 minutes of training on how to use the Adobe XD prototype. The participants were NASA-Ames or NASA-Langley researchers, developers or tech leads who had 0 to 15 years of experience. Their ages ranged from 20 to 40 years old, and they were of both genders. After training, each participant was asked to do 4 tasks of varying difficulty, using the prototype testbed. After each task they reported on task difficulty and after all tasks were completed they were asked to fill out the System Usability Survey (SUS). Performance will be assessed through task completion time and accuracy rating. Results: User perception was evaluated by the SUS which showed a mean score over the six participants of 84. All the participants were above the acceptable range which was 70 and nobody was in the marginal usability zone between 50 and 70. In addition, most of the participants did well in terms of time on task, success rate and task difficulty on all the tasks except for Task 3. Participants had two minutes to do the task correctly to succeed at the task, otherwise it was marked as a failure. The geomean for Task 1 for completion time was 22.20; Task 2 was 58.28; Task 3 was 84.68 and Task 4 was 19.61. In Task 3, three out of six people failed this task but all five scored this with an average score 4.2 out of 5 for self-rating on task difficulty.

human factors↗