Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Optical Spectroscopy of a Mega-Ampere Dense Plasma Focus

Exhibit describes an optical streaked spectroscopy system that was developed to evaluate the spectral emission of the run-down, run-in, and pinch phases on the Gemini Dense Plasma Focus. Time-resolved emission spectra were captured for Hydrogen, Deuterium, Krypton, and Argon gases from these phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion generator is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to understand and be able to fully characterize the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic – and there can often be several fusion pinches creating neutrons – a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using detector pairs designed to reduce the scatter background and with an additional measurement of the time profile of the fusion pinch near its source. The detector pairs enhance the quality of the time of flight measurements and the additional constraint posed by the measured time profile allows for temporal resolution in the spectrum reconstruction that is equal to the measurement resolution, which can be subnanosecond, and energy resolution in the 10’s of keV, without the problem being underconstrained. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy’s Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Nanoscale Editing of Multi and Single Layer Tungsten Disulfide via Gas‐Assisted Focused Electron Beam Induced Etching for Device Prototyping

Focused electron beam induced etching (FEBIE) with XeF 2 (xenon difluoride) precursor is conducted on multi-layer exfoliated WS 2 (tungsten disulfide) and monolayer WS 2 grown by chemical vapor deposition (CVD). The films are characterized by atomic force microscopy (AFM) and Raman and photoluminescence (PL) spectroscopy post-etching. The etch rates/efficiencies are reported as a function of electron beam energy, current, dwell time, and XeF 2 pressure. Bulk film Raman spectra are unchanged post-FEBIE, indicating minimal subsurface damage. Monolayer WS 2 shows a decrease in Raman and PL intensity post-FEBIE, with a dose-to-clear of ≈2 nC µm −2 . The study reveals regimes affected by the various mass transport contributions such as refresh time and the ratio of electrons/XeF 2 . Spontaneous etching was discovered during FEBIE of large patterned areas due to the long frame/refresh times. Density functional theory and ab initio molecular dynamics simulations compares desorption of SF x and WF x molecules from pristine WS 2 basal planes and pore edges, revealing the spontaneous etching is consistent with etching of partially etched monolayers during each frame. Single-line etching width of 21 nm, and patterning flakes into 100 nm wide channels are demonstrated. In conclusion, this work demonstrates the possibility of editing WS 2 flakes into electronic devices of arbitrary dimensions for semiconductor applications.

2D materials↗

Focused Helium Ion Beam for Direct Patterning of Monolayer MoS 2 Nanoribbon Field Effect Devices

The helium ion microscope (HIM) focused ion beam (FIB) has emerged as a powerful tool to directly pattern nanostructures below 10 nm due to its high-resolution capabilities and the inert nature of the ion source. These attributes make HIM FIB particularly interesting for patterning 2D materials such as transition metal dichalcogenides (TMDs) to investigate transport phenomena at the nanoscale. Reported here is the fabrication of MoS 2 nanoribbon devices using HIM FIB-induced etching (FIBIE) with XeF 2 , allowing for reduced ion dose compared to direct sputtering. While patterning is efficacious, the devices exhibit performance degradation with decreasing nanoribbon width due to damage up to 150 nm beyond the patterned edge. Incorporating an hBN encapsulation improves device performance by one order of magnitude, although the lateral extent of damage remains unchanged. The spatial distribution of damage is shown to be determined by the forward- and backscattered ions and electrons, while the hBN encapsulation layer substantially reduces damage from XeF 2 interactions in unexposed regions. Raman and photoluminescence (PL) measurements corroborate these findings, while ion/solid interaction simulations further elucidate the resolution limits imposed by substrate interactions. In conclusion, this work provides critical insights and a practical pathway for utilizing HIM FIBIE in 2D TMD functional device patterning.

MoS 2↗

Radiation Response of Ga 2 O 3 MOSFETs Probed via Focused Particle Beams

Gallium Oxide (Ga 2 O 3 ), particularly in its β-phase, is attracting lots of interest for high-power and high-voltage electronics due to its wide bandgap, high breakdown field, and thermal stability. This study investigates the radiation response of Ga 2 O 3 Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) under Total Ionizing Dose (TID) and Displacement Damage (DD) conditions, which are critical for applications in radiation environments. Utilizing a dual-beam Focused Ion Beam and Scanning Electron Microscope setup, microscale analysis of radiation effects on individual devices is performed. The findings reveal distinct behaviors under TID and DD + TID conditions, with TID leading to threshold voltage shifts due to trapped charges, while DD results in decreased drive current attributed to increased carrier scattering from lattice defects. Notably, it is demonstrated that the TID effect can be mitigated through dynamic threshold voltage adjustments and that the predicted TID from ions calculated by Monte Carlo simulations overestimates actual TID due to unaccounted charge yield effects. In conclusion, this research enhances the understanding of Ga2O3 MOSFETs' performance in harsh radiation environments, providing insights for the design of robust electronic devices for space and nuclear applications.

MOSFET↗

Three-Dimensional Reconstruction and Microstructure Modeling of Porosity-Graded Cathode Using Focused Ion Beam and Homogenization Techniques

In this study, microstructure of a porosity-graded lanthanum strontium manganite (LSM) cathode of solid oxide fuel cells (SOFCs) has been characterized using focused ion beam (FIB) and scanning electron microscopy(SEM) combined with image processing. Two-point correlation functions of the two-dimensional (2D) images taken along the direction of porosity gradient are used to reconstruct a three-dimensional (3D) microstructure. The effective elastic modulus of the two-phase porosity-graded cathode is predicted using strong contrast (SC) and composite inclusion (CI) homogenization techniques. The effectiveness of the two methods in predicting the effective elastic properties of the porositygraded LSM cathode is investigated in comparison with the results obtained from the finite element model (FEM).

25 ENERGY STORAGE↗

TATB thermal decomposition: Expanding the molecular profile with cryo-focused pyrolysis GC-MS

Understanding the molecular composition of high explosives during thermal decomposition is vital for predicting the sensitivity, safety, and performance of explosive materials. The thermal decomposition of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) has been linked to the formation of furazans through a series of dehydration reactions of the NO2 and NH2 groups on the phenyl ring, along with breakdown into small molecules (≤120 amu). Molecular identification of compounds formed in this transformation of the furazans to light gases has been lacking. To address this, we have applied a pseudo-confined sampling system in a cryo-focused pyrolysis gas chromatography-mass spectrometry (pyGC-MS) system to molecularly identify these intermediates. By design, sublimation of TATB, which has complicated MS analyses of thermal degradation, was significantly reduced and additional compounds were identified with potential structural information. In addition to the known furazan compounds, one of these compounds forms from the loss of oxygen from benzo-trifurazan (F3) and produces an open ring structure that may be the first step in the formation of lower molecular weight furazan breakdown products. The loss of a nitro group from benzo-monofurazan (F1) was also discovered and implicates the formation of oxidizing NO2 gas in the thermal decomposition mechanism. So these findings are vital for understanding the proper heat flow from energetic materials on a molecular level, necessary when measuring enthalpy and developing decomposition models based on kinetic parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tungsten Diselenide Patterning and Nanoribbon Formation by Gas‐Assisted Focused‐Helium‐Ion‐Beam‐Induced Etching

A gas‐assisted focused‐helium‐ion beam‐induced etching (FIBIE) process is introduced, which accelerates direct‐write patterning of WSe 2 relative to standard ion milling. The etching process utilizes the XeF 2 precursor molecule to provide a chemical assist for enhanced material removal relative to ion sputtering. The FIBIE process enables high‐fidelity patterning of WSe 2 with doses 5× lower than standard He + milling. This enables the formation of high‐resolution WSe 2 nanoribbons with dimensions less than 10 nm. The WSe 2 nanoribbons demonstrate high Raman anisotropy and nanoribbon electrical measurements are reported for the first time. The normalized on‐currents of field‐effect transistors reveal that the electron and hole currents are both suppressed and scale with the nanoribbon width, with the electron transport experiencing more degradation. However, on‐currents of nanoribbons created by the FIBIE process remain orders of magnitude greater than nanoribbons formed by standard He + milling. Scanning transmission electron microscopy and complementary Monte Carlo ion–solid simulations reveal that the reduced currents are partially due to ion‐induced damage in the WSe 2 .

Stanford, Michael G.↗

Discrete Max-Focusing

The Quantum Focusing Conjecture (QFC) lies at the foundation of holography and semiclassical gravity. The QFC implies the Bousso bound and the Quantum Null Energy Condition (QNEC). The QFC also ensures the consistency of the quantum extremal surface prescription and bulk reconstruction in AdS/CFT. However, the central object in the QFC — the expansion of lightrays — is not defined at points where geodesics enter or leave a null congruence. Moreover, the expansion admits three inequivalent quantum extensions in terms of the conditional max, min, and von Neumann entropies.

AdS-CFT Correspondence↗

Standardized report template for indeterminate renal masses at CT and MRI: a collaborative product of the SAR Disease-Focused Panel on Renal Cell Carcinoma

Purpose: To create a succinct yet comprehensive evidence-based structured report template for indeterminate renal masses characterized at CT and MRI. Methods: This IRB-exempt, iterative, multi-institutional quality improvement project was informed by published data derived from a multi-institutional survey and a multi-institutional review of CT and MRI radiology reports. A two-stage blinded Delphi process by the 16-member 12-institution Society of Abdominal Radiology Disease-Focused Panel on Renal Cell Carcinoma was conducted to create a structured report template for indeterminate renal masses evaluated at CT and MRI. Individual reporting characteristics were scored by members as ‘core,’ ‘optional,’ or ‘exclude.’ Threshold for inclusion was ≥ 80% support. If < 80% members considered a characteristic a ‘core’ feature, but ≥ 80% considered it either ‘core’ or ‘optional,’ it was considered an ‘optional’ feature. If neither was the case, the characteristic was excluded. Free-text comments were permitted. Characteristics considered ‘core’ by 50–99% of respondents in Round 1 (i.e., nonunanimous support) and uninvestigated free-text comments were assessed in Round 2. Core and optional structured reporting templates were derived. Results: The response rate was 100% in Round 1 (16/16) and Round 2 (16/16). In Round 1, 5 characteristics had unanimous support as ‘core’ features. Following Round 2, 13 characteristics had ≥ 80% support as ‘core’ features, and 10 characteristics had ≥ 80% support as ‘optional’ features. Structured report templates were derived. Discussion: Structured ‘core’ and ‘optional’ templates for indeterminate renal masses at CT and MRI were derived, which may improve compliance with reporting preferred and essential imaging characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of multimodal imaging in guiding resectability and cytoreduction in pancreatic neuroendocrine tumors: focus on PET and MRI

Pancreatic neuroendocrine tumors (pNETs) are rare neoplasms that secrete peptides and neuro-amines. pNETs can be sporadic or hereditary, syndromic or non-syndromic with different clinical presentations and prognoses. The role of medical imaging includes locating the tumor, assessing its extent, and evaluating the feasibility of curative surgery or cytoreduction. Pancreatic NETs have very distinctive phenotypes on CT, MRI, and PET. PET have been demonstrated to be very sensitive to detect either well-differentiated pNETs using {sup 68}Gallium somatostatin receptor (SSTR) radiotracers, or more aggressive undifferentiated pNETS using {sup 18}F-FDG. A comprehensive interpretation of multimodal imaging guides resectability and cytoreduction in pNETs. The imaging phenotype provides information on the differentiation and proliferation of pNETs, as well as the spatial and temporal heterogeneity of tumors with prognostic and therapeutic implications. This review provides a structured approach for standardized reading and reporting of medical imaging studies with a focus on PET and MR techniques. It explains which imaging approach should be used for different subtypes of pNET and what a radiologist should be looking for and reporting when interpreting these studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Society of abdominal radiology gastrointestinal bleeding disease-focused panel consensus recommendations for CTA technical parameters in the evaluation of acute overt gastrointestinal bleeding

Purpose: To formulate consensus recommendations for CT angiography technical parameters used to evaluate overt gastrointestinal (GI) bleeding. Methods: An electronic questionnaire consisting of 17 questions was sent to a panel of 16 radiologists with expertise on the imaging of GI bleeding from the Society of Abdominal Radiology GI Bleeding disease-focused panel to obtain consensus agreement on issues related to CTA technical parameters for imaging overt GI bleeding. A multi-round Delphi method of voting was performed to obtain consensus which was defined as ≥ 80% agreement. Results: Consensus agreement was reached in 15/17 (89%) of the questions including the technique for the administration of IV contrast, the number of phases, scan timing, and image reconstruction. Conclusions: A panel of experts on the imaging of GI bleeding from the Society of Abdominal Radiology was able to reach consensus on the majority of technical parameters used for CTA of overt GI bleeding. These recommendations should improve the quality of patient care by adopting these minimal technical requirements for optimal exam performance and lead to less variation in the performance of these exams which will facilitate collecting and comparing published data from different centers. These recommendations will need revisions as additional scientific data become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal cancer lexicon: consensus statement from the society of abdominal radiology rectal & anal cancer disease-focused panel

Standardized terminology is critical to providing consistent reports to referring clinicians. This lexicon aims to provide a reference for terminology frequently used in rectal cancer and reflects the consensus of the Society of Abdominal Radiology Disease Focused Panel in Rectal cancer. This lexicon divided the terms into the following categories: primary tumor staging, nodal staging, treatment response, anal canal anatomy, general anatomy, and treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Midterm Results after Uterine Artery Embolization Versus MR-Guided High-Intensity Focused Ultrasound Treatment for Symptomatic Uterine Fibroids

Purpose: To compare the rate of reintervention and midterm changes in symptom severity (SS) and Total health-related quality of life (HRQoL) scores after uterine artery embolization (UAE) and magnetic resonance-guided high-intensity focused ultrasound (MR-g HIFU) for symptomatic uterine fibroids. Methods: Eighty women (median age 38.3 years), equally eligible for MR-g HIFU and UAE who underwent one of both treatments between 2002 and 2009 at our institution, were included. The primary end point of the study was defined as the rate of reintervention after both therapies. The secondary outcome was defined as changes in SS and Total HRQoL scores after treatment. SS and Total HRQoL scores before treatment and at midterm follow-up (median 13.3 months) were assessed by the uterine fibroid symptom and quality-of-life questionnaire (UFS-QoL) and compared. Results: The rate of reintervention was significantly lower after UAE than after MR-g HIFU (p = 0.002). After both treatments, SS and Total HRQoL scores improved significantly from baseline to follow-up (UAE: p < 0.001, p < 0.001; MR-g HIFU: p = 0.002, p < 0.001). Total HRQoL scores were significantly higher after UAE than after MR-g HIFU (p = 0.032). Changes in the SS scores did not differ significantly for both treatments (p = 0.061). Conclusion: UAE and MR-g HIFU significantly improved the health-related quality of life of women with symptomatic uterine fibroids. After UAE, the change in Total HRQoL score improvement was significantly better, and a significantly lower rate of reintervention was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Respiratory Motion in Extracorporeal High-Intensity Focused Ultrasound Treatment in Upper Abdominal Organs: Current Status and Perspectives

Extracorporeal high-intensity focused ultrasound (HIFU) is a minimally invasive therapy considered with increased interest for the ablation of small tumors in deeply located organs while sparing surrounding critical tissues. A multitude of preclinical and clinical studies have showed the feasibility of the method; however, concurrently they showed several obstacles, among which the management of respiratory motion of abdominal organs is at the forefront. The aim of this review is to describe the different methods that have been proposed for managing respiratory motion and to identify their advantages and weaknesses. First, we specify the characteristics of respiratory motion for the liver, kidneys, and pancreas and the problems it causes during HIFU planning, treatment, and monitoring. Second, we make an inventory of the preclinical and clinical approaches used to overcome the problem of organ motion. Third, we analyze their respective benefits and drawbacks to identify the remaining physical, technological, and clinical challenges. We thereby consider the outlook of motion compensation techniques and those that would be the most suitable for clinical use, particularly under magnetic resonance thermometry monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility Study on MR-Guided High-Intensity Focused Ultrasound Ablation of Sciatic Nerve in a Swine Model: Preliminary Results

IntroductionSpastic patients often seek neurolysis, the permanent destruction of the sciatic nerve, for better pain management. MRI-guided high-intensity focused ultrasound (MRgHIFU) may serve as a noninvasive alternative to the prevailing, more intrusive techniques. This in vivo acute study is aimed at performing sciatic nerve neurolysis using a clinical MRgHIFU system.MethodsThe HIFU ablation of sciatic nerves was performed in swine (n = 5) using a HIFU system integrated with a 3 T MRI scanner. Acute lesions were confirmed using T1-weighted contrast-enhanced (CE) MRI and histopathology using hematoxylin and eosin staining. The animals were euthanized immediately following post-ablation imaging.ResultsReddening and mild thickening of the nerve and pallor of the adjacent muscle were seen in all animals. The HIFU-treated sections of the nerves displayed nuclear pyknosis of Schwann cells, vascular hyperemia, perineural edema, hyalinization of the collagenous stroma of the nerve, myelin sheet swelling, and loss of axons. Ablations were visible on CE MRI. Non-perfused volume of the lesions (5.8–64.6 cc) linearly correlated with estimated lethal thermal dose volume (4.7–34.2 cc). Skin burn adjacent to the largest ablated zone was observed in the first animal. Bilateral treatment time ranged from 55 to 138 min, and preparation time required 2 h on average.ConclusionThe acute pilot study in swine demonstrated the feasibility of a noninvasive neurolysis of the sciatic nerve using a clinical MRgHIFU system. Results revealed that acute HIFU nerve lesions were detectable on CE MRI, gross pathology, and histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electroforming-Free TaOx Memristors using Focused Ion Beam Irradiations

In this study, we demonstrate creation of electroforming-free TaOx memristive devices using focused ion beam irradiations to locally define conductive filaments in TaOx films. Electrical characterization shows that these irradiations directly create fully functional memristors without the need for electroforming. Finally, ion beam forming of conductive filaments combined with state-of-the-art nano-patterning presents a CMOS compatible approach to wafer level fabrication of fully formed and operational memristors.

36 MATERIALS SCIENCE↗