Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FILM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

Evaporation-driven instability of the precorneal tear film

Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. It was proposed recently that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink.

dry eye↗

SU-E-T-206: Comparison of EBT and EBT3 RadioChromic Films in Radiation Field of Parotid Cancer Radiotherapy

Purpose: The aim of the current study is to compare EBT and EBT3 RadioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. Methods: The calibrations of EBT and EBT3 films were performed with the same setups for doses ranging from 0.2 Gy to 5 Gy using 6 MV photon beam of a Siemens Primus linac. These films were scanned in color mode (RGB) by a Microtek (1000XL) scanner and the red color channel data was extracted. Treatment planning for parotid cancer radiation therapy was performed on a RANDO phantom. Skin dose was measured at different points in the right anterior oblique (RAO) and right posterior oblique (RPO) fields by EBT and EBT3 films. Results: Dosimetry was performed with the same conditions for the two film types for calibration and in-phantom in parotid cancer radiotherapy. The measured net optical density (NOD) in EBT film was in some extent higher than that from EBT3 film. The minimum difference between these two films under calibration conditions was about 2.9% (for 0.2 Gy). However, the maximum difference was 35.5% (for 0.5 Gy). In the therapeutic fields of parotid cancer radiotherapy at different points, the measured dose from EBT film was higher than the EBT3 film. In these fields the minimum and maximum measured dose differences were 16.0% and 25.5%, respectively. Conclusion: With the same irradiation and reading conditions, EBT film demonstrates higher NOD than the EBT3 film. This effect may be related to the higher sensitivity of EBT film over EBT3 film. However, the obtained dose differences between these two films in low dose range can be due to the differences in fitting functions applied following the calibration process.

60 APPLIED LIFE SCIENCES↗

Effects of different annealing atmospheres on the properties of cadmium sulfide thin films

Graphical abstract: The effects of different annealing atmospheres (air and sulfur) on the structural, morphological and optical properties of CdS thin films were studied at three different pH values. - Highlights: • Compactness and smoothness of the films were enhanced after sulfur annealing. • Micro-strain values of some films were improved after sulfur annealing. • Dislocation density values of some films were improved after sulfur annealing. • Band gap values of the films were improved after sulfur annealing. - Abstract: Cadmium sulfide (CdS) thin films were prepared on glass substrates by using chemical bath deposition (CBD) technique. The effects of different annealing atmospheres (air and sulfur) on the structural, morphological and optical properties of CdS thin films were studied at three different pH values. Compactness and smoothness of the films (especially for pH 10.5 and 11) enhanced after sulfur annealing. pH value of the precursor solution remarkably affected the roughness, uniformity and particle sizes of the films. Based on the analysis of X-ray diffraction (XRD) patterns of the films, micro-strain and dislocation density values of the sulfur-annealed films (pH 10.5 and 11) were found to be lower than those of air-annealed films. Air-annealed films (pH 10.5, 11 and 11.5) exhibited higher transmittance than sulfur-annealed films in the wavelength region of 550–800 nm. Optical band gap values of the films were found between 2.31 eV and 2.36 eV.

36 MATERIALS SCIENCE↗

Preliminary study of CdTe and CdTe:Cu thin films nanostructures deposited by using DC magnetron sputtering

Growth and properties of CdTe and CdTe:Cu thin films nanostrucures deposited by using dc magnetron sputtering are reported. Scanning electron microscope (SEM) was used to observe the surface morphologies of the thin films. At growth conditions of 250 °C and 14 W, CdTe films did not yet evenly deposited. However, at growth temperature and plasma power of 325 °C and 43 W, both CdTe and CdTe:Cu(2%) have deposited on the substrates. In this condition, the morphology of the films indicate that the films have a grain-like nanostructures. Grain size diameter of about 200 nm begin to appear on top of the films. Energy Dispersive X-rays spectroscopy (EDX) was used to investigate chemical elements of the Cu doped CdTe film deposited. It was found that the film deposited consist of Cd, Te and Cu elements. XRD was used to investigate the full width at half maximum (FWHM) values of the thin films deposited. The results show that CdTe:Cu(2%) thin film has better crystallographic properties than CdTe thin film. The UV-Vis spectrometer was used to investigate the optical properties of thin films deposited. The transmittance spectra showed that transmittance of CdTe:Cu(2%) film is lower than CdTe film. It was found that the bandgap energy of CdTe and CdTe:Cu(2%) thin films of about 1.48 eV.

36 MATERIALS SCIENCE↗

Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry

Purpose: A known factor affecting the accuracy of radiochromic film dosimetry is the lateral response artifact (LRA) induced by nonuniform response of a flatbed scanner in the direction perpendicular to the scan direction. This work reports a practical solution to eliminate such artifacts for all forms of dose QA. Methods: EBT3 films from a single production lot (02181401) cut into rectangular 4 × 5 cm{sup 2} pieces, with the long dimension parallel to the long dimension of the original 20.3 × 25.4 cm{sup 2} sheets, were exposed at a depth of 5 cm on a Varian Trilogy at the center of a 20 × 20 cm{sup 2} open field at seven doses between 50 and 1600 cGy using 6 MV photons. These films together with an unexposed film from the same production lot were lined one next to the other on an Epson 10000XL or 11000XL scanner in portrait orientation with their long dimension parallel to the scan direction. Scanned images were then obtained with the line of films positioned at seven discrete lateral locations perpendicular to the scan direction. The process was repeated in landscape orientation and on three other Epson scanners. Data were also collected for three additional production lots of EBT3 film (11051302, 03031401, and 03171403). From measurements at the various lateral positions, the scanner response was determined as a function of the lateral position of the scanned film. For a given color channel X, the response at any lateral position L is related to the response at the center, C, of the scanner by Response(C, D, X) = A{sub L,X} + B{sub L,X}⋅Response(L, D, X), where D is dose and the coefficients A{sub L,X} and B{sub L,X} are determined from the film measurements at the center of the scanner and six other discrete lateral positions. The values at intermediate lateral positions were obtained by linear interpolation. The coefficients were determined for the red, green, and blue color channels, preserving the ability to apply triple-channel dosimetry once corrections were applied to compensate for the lateral position response artifact. To validate this method, corrections were applied to several films that were exposed to 15 × 15cm{sup 2} open fields and large IMRT and VMAT fields and scanned at the extreme edges of the scan window in addition to the central location. Calibration and response data were used to generate dose maps and perform gamma analysis using single- or triple-channel dosimetry with FilmQAPro 2014 software. Results: The authors’ study found that calibration curves at the different lateral positions could be correlated by a simple two-point rescaling using the response for unexposed film as well as the response of film exposed at high doses between 800 and 1600 cGy. The coefficients A{sub L,X} and B{sub L,X} for each color channel X were found to be independent of dose at each lateral location L. This made it possible to apply the relationship Response(C, D, X) = A{sub L,X} + B{sub L,X}⋅Response(L, D, X), to the raw film responses, permitting correction of the response values at any lateral position to an equivalent response, as if that part of the film was located at the center of the scanner. This correction method was validated for several films exposed to open as well as large IMRT and VMAT fields. Conclusions: The work reported elaborates on the process using the correction procedures to eliminate the lateral response artifact and demonstrates improvements in the accuracy of radiochromic film dosimetry for the radiation therapy quality assurance applications.

07 ISOTOPE AND RADIATION SOURCES↗

Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a still preclinical tumor therapy approach that uses arrays of a few tens of micrometer wide parallel beams separated by a few 100 μm. The production, measurement, and planning of such radiation fields are a challenge up to now. Here, the authors investigate the feasibility of radiochromic film dosimetry in combination with a microscopic readout as a tool to validate peak and valley doses in MRT, which is an important requirement for a future clinical application of the therapy. Methods: Gafchromic{sup ®} HD-810 and HD-V2 films are exposed to MRT fields at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF) and are afterward scanned with a microscope. The measured dose is compared with Monte Carlo calculations. Image analysis tools and film handling protocols are developed that allow accurate and reproducible dosimetry. The performance of HD-810 and HD-V2 films is compared and a detailed analysis of the resolution, noise, and energy dependence is carried out. Measurement uncertainties are identified and analyzed. Results: The dose was measured with a resolution of 5 × 1000 μm{sup 2} and an accuracy of 5% in the peak and between 10% and 15% in the valley region. As main causes for dosimetry uncertainties, statistical noise, film inhomogeneities, and calibration errors were identified. Calibration errors strongly increase at low doses and exceeded 3% for doses below 50 and 70 Gy for HD-V2 and HD-810 films, respectively. While the grain size of both film types is approximately 2 μm, the statistical noise in HD-V2 is much higher than in HD-810 films. However, HD-810 films show a higher energy dependence at low photon energies. Conclusions: Both film types are appropriate for dosimetry in MRT and the microscope is superior to the microdensitometer used before at the ESRF with respect to resolution and reproducibility. However, a very careful analysis of the image data is required. Dosimetry at low photon energies should be performed with great caution due to the energy sensitivity of the films. In this respect, HD-V2 films showed to have an advantage over HD-810 films. However, HD-810 films have a lower statistical noise level. When a higher resolution is required, e.g., for the dosimetry of pencil beam irradiations, noise may render HD-V2 films inapplicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical and Optical Characteristics of Si-Nanoparticle Films Deposited onto Substrates by High-Voltage Electrospraying from Ethanol Sols

The optical and electrical characteristics of films consisting of nanocrystalline silicon (nc-Si) deposited onto substrates by the high-voltage electrospraying of nc-Si sols in ethanol are investigated. It is found that the interaction of ethanol droplets carrying Si nanoparticles with a corona-discharge electric field leads to the polymerization of ethanol and the formation of a polymer layer on the Si-nanoparticle surface. A high-voltage facility for depositing the films using an additional focusing electrode allows one to change the geometry of the electric field and intensity in the region of the ethanol droplet flow. As a result, nc-Si films with qualitatively different properties of the polymer on the nanoparticle surface are formed, specifically, nc-Si-A and nc-Si-B, obtained without a focusing electrode and with it, respectively. Upon annealing at temperatures of up to 400°С, the optical band gap E{sub g} of the nc-Si-A films increases from ~1.9 to ~2.2 eV, while the E{sub g} value of the nc-Si-B films remains constant and amounts to 1.85 eV. The constant E{sub g} value of the nc-Si-B films is explained by the properties of the polymer on the Si-nanoparticle surface and the more effective blocking of oxygen penetration from the surrounding environment upon annealing at temperatures of up to 400°C than in the case of a polymer in nc-Si-A films. The temperature dependences of the dark and photoinduced conductivity of nc-Si-A films are approximated with good accuracy by two activation-type exponential functions and the dark activation energies are ~0.75 and 0.1 eV, respectively. The conductivity of the nc-Si-A films noticeably decreases under irradiation of the samples at wavelengths of 460–470 nm. The temperature dependences of the conductivity of the nc-Si-B films are approximated with good accuracy by exponential functions with activation energies of 0.73 (in the dark) and 0.59 eV (under photoexcitation). In contrast to the case of nc-Si-A films, the photoconductivity of nc-Si-B films grows more than fourfold relative to the dark conductivity under analogous illumination. The nc-Si-B films are photoactive and sandwich-like Al/nc-Si-B/Al structures can generate a voltage. The dark conductivity and photoconductivity of the nc-Si-A films in the voltage range of V > 2 V are determined by the two-center Poole–Frenkel effect; the concentration of the centers affecting the Poole–Frenkel conductivity is ~3 × 10{sup 17} cm{sup –3}. In nc-Si-B films in the voltage range of 2–5 V, electron transport is determined by space-charge-limited currents and, at high voltages, by the two-center Poole–Frenkel effect. The concentration of traps contributing to the space-charge-limited currents is ~4 × 10{sup 16} cm{sup –3}. The concentration of Poole–Frenkel centers affecting the conductivity decreases according to the activation law with an activation energy of 0.7 eV from 3 × 10{sup 16} to 2 × 10{sup 14} cm{sup –3} with a decrease in temperature from 120°C to 40°C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Continuous polymer films deposited on top of porous substrates using plasma-enhanced atomic layer deposition and molecular layer deposition

Molecular layer deposition (MLD) is able to produce ultrathin polymer films with control over thickness, cross-linking, and chemical composition. With these capabilities, MLD should be useful in the fabrication of novel polymer membranes on porous supports. However, confining a continuous MLD film to the surface of porous substrates is difficult because of MLD film growth in the pores. The deposition in the pores lowers the conductance of the porous support. This paper presents a method to deposit continuous polymer films on top of porous substrates. In this method, Al2O3 plasma-enhanced atomic layer deposition (PE-ALD) using trimethylaluminum and oxygen plasma as the reactants was first used to cap the pores of the substrate. Subsequently, a polyamide MLD film was deposited on the Al2O3 PE-ALD capping layer using m-phenylenediamine and trimesoyl chloride as the reactants. The Al2O3 pore caps were then removed from the porous substrate by etching from the backside using a timed exposure to a dilute sodium hydroxide solution. This method was demonstrated using anodic aluminum oxide (AAO) and polyethersulfone (PES) porous substrates. Al2O3 PE-ALD film growth was limited to the top of the porous substrate, resulting in rapid surface recombination or high sticking coefficients for the reactive plasma species within the pores. Gas permeance measurements confirmed the pore capping of the AAO substrates. The reopening of the pores by dissolving the Al2O3 pore caps with a sodium hydroxide solution was monitored using gas permeance versus etch time. The removal of the Al2O3 pore caps from the PES substrates could also dissolve the Al2O3 layer underneath the MLD film. The loss of this Al2O3 layer led to the detachment of the MLD film from the PES substrate. However, the MLD film could be anchored to the PES support at fractures located in the Al2O3 film prior to the MLD. The Al2O3 film fracture allowed the MLD film to anchor firmly to the PES substrate by MLD in the pores of the PES porous substrate. The distance between the anchor points was a function of fracture density. This distance could be controlled by applying a tensile stress to the Al2O3 PE-ALD film to fracture the film through sample bending. This method produced firmly anchored polymer MLD films on top of the PES porous substrates.

Welch, Brian C. (ORCID:000000029747045X)↗

Metalorganic chemical vapor deposition of ZnGeN 2 films on GaN: effects of cation stoichiometry on surface morphology and crystallinity

Novel optoelectronic device designs based on the heterostructures of III-N and II-IV-N 2 are promising to advance device performance significantly. For example, by utilizing InGaN-ZnGeN 2 quantum well (QW) structures instead of pure InGaN, the band structure engineering in the QW active region can lead to improved electron-hole wavefunction overlap, and thus enhance the radiative efficiency for photon generation. These novel heterostructures have great potential to address the current challenge of low quantum efficiency in InGaN QW based light emitting diodes emitting in green and beyond. The materials development of ZnGeN 2 is still at an early stage as compared to the much matured GaN material system. In an ideal octet rule preserving ordered structure of ZnGeN 2 , every N atom is coordinated by exactly two Zn and two Ge atoms. However, local violation of octet rule can be caused by non-ideal coordination of N by the cations. The disordered structure is thermodynamically less favorable but can still be achieved, for example, in kinetics-limited growth regime. The ordered ZnGeN 2 has a bandgap very close to that of GaN (~3.4 eV) and a lattice mismatch of <0.1% with GaN. Interestingly, the valence band of ZnGeN 2 has been predicted to be ~1 eV above that of GaN, which has inspired novel designs for high efficiency light emitters. In this work, we investigated the metalorganic chemical vapor deposition (MOCVD) of ZnGeN 2 films on GaN/c-sapphire templates. Diethylzinc (DEZn), germane (GeH4) and ammonia were used as the precursors for Zn, Ge and N, respectively. A systematic study was conducted to investigate the cation stoichiometry as a function of growth temperature (TG), total reactor pressure (P) and DEZn/GeH 4 molar flow rate ratio (RII/IV). Under the investigated growth window, the Zn/(Zn+Ge) composition in the films, determined from energy dispersive X-ray spectroscopy, decreased monotonically with increase in TG but increased with increase in P and RII/IV. Atom probe tomography data did not indicate the presence of any secondary phases such as Zn 3 N 2 or Ge 3 N 4 . The surface morphology and crystallinity of the grown films had strong correlation with the Zn/(Zn+Ge) composition. The scanning electron microscopy images showed that the near-stoichiometric films have planar surfaces whereas Zn-rich films had crystallites on their surface and the Zn-poor films had faceted surface. Scanning transmission electron microscopy (STEM) imaging revealed that the Zn-rich and Zn-poor films have columnar and filament-like morphology, respectively, whereas the near-stoichiometric films have continuous film-like cross-sectional morphology. TEM nano-diffraction patterns as well as X-ray diffraction 2θ-ω scan profiles indicate that the near stoichiometric films are single crystalline. Nano-diffraction pattern of the stoichiometric films resembled that of a disordered ZnGeN 2 structure. Room temperature Raman spectra of near-stoichiometric films showed only the phonon density of states like features of a cation disordered ZnGeN 2 . Cathodoluminescence and photoluminescence spectra measured at different temperatures had similar features with peak emission wavelength at ~ 2 eV. In conclusion, the stoichiometry of ZnGeN 2 films can be widely tuned by tuning the MOCVD growth parameters. The surface morphology and the crystallinity of the films were found to have strong correlation with the Zn/(Zn+Ge) composition. The stoichiometric ZnGeN 2 films grown on GaN were demonstrated with uniform surface morphology and high crystalline quality. The results from this work will provide pathway to implement ZnGeN 2 in device structures.

Karim, Md Rezaul↗

Technical Note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV–18 MeV

Purpose: Water is the reference medium for radiation therapy dosimetry, but for film dosimetry it is more practical to use a solid phantom. As the composition of solid phantoms differs from that of water, the energy dependence of film exposed within solid phantoms may also differ. The energy dependence of a radiochromic film for a given beam quality Q (energy for monoenergetic beams) has two components: the intrinsic energy dependence and the absorbed-dose energy dependence f(Q), the latter of which can be calculated through a Monte Carlo simulation of radiation transport. The authors used Monte Carlo simulations to study the influence of the phantom material on the f(Q) of the EBT3 radiochromic film (Ashland Specialty Ingredients, Wayne, NJ) for photon beams with energies between 3 keV and 18 MeV. Methods: All simulations were carried out with the general-purpose Monte Carlo code PENELOPE 2011. The geometrical model consisted of a cylindrical phantom, with the film positioned at different depths depending on the initial photon energy. The authors simulated monoenergetic parallel photon beams and x-ray beams from a superficial therapy system. To validate their choice of simulation parameters, they also calculated f(Q) for older film models, EBT and EBT2, comparing with published results. In addition to water, they calculated f(Q) of the EBT3 film for solid phantom materials commonly used for film dosimetry: RW1 and RW3 (PTW-Freiburg, Freiburg, Germany), Solid Water (Gammex-RMI, Madison, WI), and PMMA. Finally, they combined their calculated f(Q) with published overall energy response data to obtain the intrinsic energy dependence of the EBT3 film in water. Results: The calculated f(Q) for EBT and EBT2 films was statistically compatible with previously published data. Between 10 keV and 18 MeV, the variation found in f(Q) of the EBT3 film for water was within 2.3%, with a standard statistical uncertainty less than 1%. If the quantity dose-to-water in the phantom is considered, which is the common practice in radiation dosimetry, the maximum difference of energy dependence for the solid phantoms with respect to water is about 6%, at an energy of 50 keV. Conclusions: The EBT3 film shows a reasonably constant absorbed-dose energy dependence when irradiated in water. If the dose-to-water in the phantom is considered, the maximum difference of EBT3 film energy dependence with the solid phantoms studied with respect to water is about 6% (at an energy of 50 keV). The reported overall energy dependence of the EBT3 film in water at energies below 100 keV is mainly due to the intrinsic energy dependence.

07 ISOTOPE AND RADIATION SOURCES↗

Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system

Purpose: In radiochromic film dosimetry systems, measurements are usually obtained from film images acquired on a CCD-based flatbed scanner. The authors investigated factors affecting scan-to-scan response variability leading to increased dose measurement uncertainty. Methods: The authors used flatbed document scanners to repetitively scan EBT3 radiochromic films exposed to doses 0–1000 cGy, together with three neutral density filters and three blue optical filters. Scanning was performed under two conditions: scanner lid closed and scanner lid opened/closed between scans. The authors also placed a scanner in a cold room at 9 °C and later in a room at 22 °C and scanned EBT3 films to explore temperature effects. Finally, the authors investigated the effect of altering the distance between the film and the scanner’s light source. Results: Using a measurement protocol to isolate the contribution of the CCD and electronic circuitry of the scanners, the authors found that the standard deviation of response measurements for the EBT3 film model was about 0.17% for one scanner and 0.09% for the second. When the lid of the first scanner was opened and closed between scans, the average scan-to-scan difference of responses increased from 0.12% to 0.27%. Increasing the sample temperature during scanning changed the RGB response values by about −0.17, −0.14, and −0.05%/°C, respectively. Reducing the film-to-light source distance increased the RBG response values about 1.1, 1.3, and 1.4%/mm, respectively. The authors observed that films and film samples were often not flat with some areas up to 8 mm away from the scanner’s glass window. Conclusions: In the absence of measures to deal with the response irregularities, each factor the authors investigated could lead to dose uncertainty >2%. Those factors related to the film-to-light source distance could be particularly impactful since the authors observed many instances where the curl of film samples had the potential to cause dose uncertainty in excess of 5%. Two expedients will eliminate the uncertainties: a transparent sheet (preferably glass) placed over the scanned film keeps the film-to-light source distance constant, and an EBT3 reference film included in all scans provides correction factors for measured response values.

60 APPLIED LIFE SCIENCES↗

Analysis and Design for Sustainable Circularity of Barrier Films Used in Sheet Molding Composites Production

Sheet molding composites (SMC) are thermoset based molding compounds with a global market size of USD 2.1 billion in 2020. SMC is usually processed with multilayer barrier/carrier films to prevent emissions from volatile organic compounds (VOC). The plastic barriers are separated from SMC after the curing process and discarded. To illustrate the high consumption volume of SMC barrier/carrier films, Kohler Co., a company which uses SMC in their bath and showering product lines, alone generates over 1M lb/year of SMC barrier/carrier film waste. Therefore, high amount of SMC barrier/carrier film plastic waste creates a great opportunity for reusing, recycling, or valorization at its end of life. This can be achieved through transition from a linear to a circular supply chain design. However, this transition will not be feasible without overcoming the technical and economic barriers. This project aims to tackle this by making the film circular. Different end of life alternatives will be evaluated experimentally. The reusability of the film will be studied through applying different mechanical and solvent cleaning techniques. The operability concerns regarding the utilization of the cleaned film for long run operations will be addressed by thermally stitching the film. Pelletizing of the cleaned film will also be investigated as a viable technique for recycling or downcycling of the film as molded products. In addition to technical barriers, designing a sustainable circular supply chain for SMC carrier film products requires uncovering the collaboration opportunities between suppliers and users at different stages of the value chain to expand its use to other products. These opportunities will be investigated by finding companies willing to buy or treat the plastic film waste. Finally, the economic viability and environmental impacts of these circular design alternatives will be evaluated through techno-economic assessment (TEA) and life cycle analysis (LCA). Techno-economic and life cycle inventory data for various pathways will also be made available as one of the main outcomes of this project. Preliminary LCA results indicate that the current SMC film supply chain (base case) emits 5.81 tonne CO2 eq. and consumes 104 GJ energy per tonne of SMC film. It is estimated that alternative circular pathways result in 14-20% less CO2 emissions and 34-44% reduction in embodied energy. This project will develop a tool to analyze the circularity and sustainability of hundreds of combinations of alternatives in different life cycle stages. Users of this tool will be able to choose the best combination among these alternatives with respect to the selected economic, environmental and circularity objectives.

circular economy↗

Evidence of Room Temperature Ferromagnetism in Zn{sub 1−x}Sn{sub x}S Thin Films

Tin (Sn)-doped zinc sulfide (Zn{sub 1−x}Sn{sub x}S) thin films at different tin (Sn) concentrations (= 0.00, 0.02, 0.05, and 0.08) were coated onto Corning 7059 glass substrates using the electron beam evaporation technique. The films were subjected to different characterization techniques to study the physical properties of the thin films. The structural properties of the films were studied using a powder X-ray diffractometer (XRD), and it was found that the films were cubic in structure without any impurity phases. The crystallite size increased with an increase of Sn concentration, and the mean crystallite size was 21 nm. The chemical composition and surface morphology of the films were studied using scanning electron microscopy (FE-SEM) with energy-dispersive analysis of X-rays (EDAX). Optical properties such as transmittance and absorbance were recorded using a diffuse reflectance spectroscope (UV–vis–NIR). All the films exhibited high optical transmittance of 85% in the visible region of the solar spectrum. The band gap of the films was calculated using Tauc’s relation, and it was found that it increased from 3.53 to 3.57 eV with an increase in the Sn doping concentration from x = 0.02 to x = 0.08. The room temperature photoluminescence studies of the films were recorded using a fluorescence spectrophotometer, and it was found that the films exhibited a prominent emission peak at 420 nm. The magnetic properties of the films and glass substrates at room temperature were studied using a vibrating sample magnetometer. From this, it was found that the films were weakly ferromagnetic at room temperature and the strength of magnetization increased with an increase of doping concentration from x = 0.02 to x = 0.05 and decreased at higher doping concentrations (x = 0.08). The films showed high magnetization at x = 0.05. The films at x = 0.05 exhibited the magnetization (M{sub s}), retentivity (M{sub r}), and coercive fields (H{sub c}) 18 × 10{sup − 6} emu/cm{sup 3}, 1.6 × 10{sup − 6} emu/cm{sup 3}, and 91.80 Oe, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizations of Binary FeCr (AISI 430) Thin Films Deposited from a Single Magnetron Sputtering Under Easy Controllable Deposition Parameters

A series of 50-nm binary FeCr martensitic thin films were sputtered from a single source made of commercial AISI 430 ferritic stainless steel under the deposition rates gradually increased from 0.03 to 0.11 nm/s with 0.02 nm/s steps at stationary condition. And, under 0.09 nm/s deposition rate, a second series of the films were also deposited under the rotation speed of their substrates which was chosen at 0, 25, and 45 rpm. As far as we are concerned, this study is the first investigation of properties of the thin films produced from AISI 430. The atomic Fe content in the films increased from 79.3 to 98.6% while atomic Cr content decreased from 20.5 to 1.2% with the increase of deposition rate from 0.03 to 0.11 nm/s. According to compositional analysis, the Fe content increased while Cr content decreased with increasing deposition rate. The reason for this may be attributed to the relatively different bond energy/melting point of metals which have different contents sputtered from source material since this physical parameter is very significant for the sputtering process. And, the Fe content in the films decreased from 84.9 to 79.2 at. % while the Cr content increased from 14.9 to 20.6 at. % when the increase of rotation speed of substrate. The crystal structure of all films was observed to have a body-centered tetragonal phase and the intensity of (110) peak varied with the atomic Fe content. The surface observations of films performed by a scanning electron microscope exposed that the number of surface grains increased with the increase of deposition rate and decreased with the increase of rotation speed. According to surface roughness analysis done by an atomic force microscope, the roughness of the film surfaces increased as the deposition rate increased. And, the roughness of the film surfaces decreased as the rotation speed increased. This has been consistent with the grain size and roughness parameters. Thus, increasing deposition rate and decreasing rotation speed of the substrate caused an increase in grain size and roughness parameters. The magnetic measurements of the films achieved, by a vibrating sample magnetometer at room temperature, displayed that the saturation magnetization, M{sub s}, values increased from 820.1 to 1700.4 emu/cm{sup 3}, the remanence magnetization, M{sub r}, values increased from 293 to 817 emu/cm{sup 3}, and the coercivity, H{sub c}, value also increased from 38 to 107 Oe with the increasing of deposition rate. It is also seen that the magnetic easy axis are in the film plane due to the shape anisotropy. With the increase rotation speed, the values of M{sub s} and M{sub r} increased and the H{sub c} decreased. It was seen that variation of Fe content in the films influences the M{sub s} values and the H{sub c} values are consistent with the surface properties. It was concluded that the deposition rate and the rotation speed of the substrate play a considerable role on the structural and related magnetic properties of the sputtered FeCr thin films, and the properties of the films can be easily controlled by changing production parameters.

36 MATERIALS SCIENCE↗

Confinement and Processing Can Alter the Morphology and Periodicity of Bottlebrush Block Copolymers in Thin Films

Bottlebrush block copolymers (BBCPs) are intriguing architectural variations on linear BCPs with highly tunable structure. Confinement can have a significant impact on polymer assembly, giving rise to changes in morphology, assembly kinetics, and properties like the glass transition. Given that confinement leads to significant changes in the persistence length of bottlebrush homopolymers, it is reasonable to expect that BBCPs will see significant changes in their structure and periodicity relative to the bulk morphology. Understanding how confinement influences assembly will be important for designing BBCPs for thin film applications including membranes, integrated photonic structures, and potentially BCP lithography. In this work, in order to study the effects of confinement on BBCP conformation and morphology, a blade coating was used to prepare films with continuous variation in film thickness. Unlike thin films of linear BCPs, islands/holes were not observed, and instead mixtures of parallel and perpendicular morphologies emerge after annealing. The lamellar periodicity ($L_0$) of the morphologies is found to be thickness dependent, increasing $L_0$ with decreasing film thickness for blade coated films. Films coated out of tetrahydrofuran (THF) resulted in a single well-defined lamellar periodicity, verified through atomic force microscopy (AFM) and grazing incidence small-angle X-ray scattering (GISAXS), which increases dramatically from the bulk value (30.6 nm) and continues to increase as the film thickness decreases. The largest observed $L_0$ was 65.5 nm, and this closely approaches the estimated upper limit of 67 nm corresponding to a fully extended backbone in a bilayer arrangement. Films coated out of propylene glycol methyl ether acetate (PGMEA) resulted in a mixture of perpendicular lamellae and a smaller, likely cylindrical morphology. The lamellar portion of the film shows the same thickness dependence as the lamellae observed in the THF coated films. The scaling of the lamellar $L_0$ with respect to film thickness follows predictions for confined semiflexible polymers with weak excluded volume interactions and can be related to models for confinement of DNA. Spin coated films shows the same reduction in periodicity, although at very different film thicknesses. This result suggests that the material has shallow free-energy barriers to transitioning between different $L_0$ and morphologies, a property that could be taken advantage of for patterning diverse structures with a single material.

36 MATERIALS SCIENCE↗

Dual mechanical behaviour of hydrogen in stressed silicon nitride thin films

In the present article, we report a study on the mechanical behaviour displayed by hydrogen atoms and pores in silicon nitride (SiN) films. A simple three-phase model is proposed to relate the physical properties (stiffness, film stress, mass density, etc.) of hydrogenated nanoporous SiN thin films to the volume fractions of hydrogen and pores. This model is then applied to experimental data extracted from films deposited by plasma enhanced chemical vapour deposition, where hydrogen content, stress, and mass densities range widely from 11% to 30%, −2.8 to 1.5 GPa, and 2.0 to 2.8 g/cm{sup 3}, respectively. Starting from the conventional plotting of film's Young's modulus against film porosity, we first propose to correct the conventional calculation of porosity volume fraction with the hydrogen content, thus taking into account both hydrogen mass and concentration. The weight of this hydrogen-correction is found to evolve linearly with hydrogen concentration in tensile films (in accordance with a simple “mass correction” of the film density calculation), but a clear discontinuity is observed toward compressive stresses. Then, the effective volume occupied by hydrogen atoms is calculated taking account of the bond type (N-H or Si-H bonds), thus allowing a precise extraction of the hydrogen volume fraction. These calculations applied to tensile films show that both volume fractions of hydrogen and porosity are similar in magnitude and randomly distributed against Young's modulus. However, the expected linear dependence of the Young's modulus is clearly observed when both volume fractions are added. Finally, we show that the stiffer behaviour of compressive films cannot be only explained on the basis of this (hydrogen + porosity) volume fraction. Indeed this stiffness difference relies on a dual mechanical behaviour displayed by hydrogen atoms against the film stress state: while they participate to the stiffness in compressive films, hydrogen atoms mainly behave like pores in tensile films where they do not participate to the film stiffness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructure of a-C:H films prepared on a microtrench and analysis of ions and radicals behavior

Amorphous carbon films (a-C:H) were prepared on a microtrench (4-μm pitch and 4-μm depth), and the uniformity of film thickness and microstructure of the films on the top, sidewall, and bottom surfaces of the microtrench were evaluated by scanning electron microscopy and Raman spectroscopy. The a-C:H films were prepared by bipolar-type plasma based ion implantation and deposition (bipolar PBII&D), and the negative pulse voltage, which is the main parameter dominating the film structure, was changed from −1.0 to −15 kV. Moreover, the behavior of ions and radicals was analyzed simultaneously by combining the calculation methods of Particle-In-Cell/Monte Carlo Collision (PIC-MCC) and Direct Simulation Monte Carlo (DSMC) to investigate the coating mechanism for the microtrench. The results reveal that the thickness uniformity of a-C:H films improves with decreasing negative pulse voltage due to the decreasing inertia of incoming ions from the trench mouth, although the film thickness on the sidewall tends to be much smaller than that on the top and bottom surfaces of the trench. The normalized flux and the film thickness show similar behavior, i.e., the normalized flux or thickness at the bottom surface increases at low negative pulse voltages and then saturates at a certain value, whereas at the sidewall it monotonically decreases with increasing negative voltage. The microstructure of a-C:H films on the sidewall surface is very different from that on the top and bottom surfaces. The film structure at a low negative pulse voltage shifts to more of a polymer-like carbon (PLC) structure due to the lower incident energy of ions. Although the radical flux on the sidewall increases slightly, the overall film structure is not significantly changed because this film formation at a low negative voltage is originally dominated by radicals. On the other hand, the flux of radicals is dominant on the sidewall in the case of high negative pulse voltage, resulting in a deviation from the Raman behavior of a-C:H films deposited by bipolar PBII&D. This tendency intensifies as the negative voltage becomes greater. Also, the energy of incident ions on the sidewall of the trench increases with increasing negative voltage, which causes a shift in the Raman data of the sidewall to the bottom right corner on the figure depicting the relationship of the FWHM(G) and the G-peak position, indicating increased graphitization of a-C:H film.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗