Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Validation of SPH code Spheral to model interacting solid bodies in a supersonic flow

Contemporary discussions of planetary defense involve analyzing the risks posed by smaller sized, 20 to 200 m diameter, asteroids which are capable of breaking up in the atmosphere and generating a blast wave. Consequence assessments for this size class of asteroids are performed through fast-running analytic or semi-analytic models which are informed by high-fidelity hydrocode simulations of asteroid entry and breakup. However, insufficient historical data necessitates validating the independent physical processes which dominate airburst events. Here, the Fluid Solid Interface Smoothed Particle Hydrodynamics solver was previously used by Pearl et al. in 2023 to model the Chelyabinsk airburst and is used here to perform a series of validation simulations. The first effort involves modeling a cylinder in a hypersonic flow and comparing the bow shock geometry to that predicted by analytic theory. The second effort involves modeling the separation of two spherical bodies in supersonic flow and validating against experimental footage. Combined, these exercises demonstrate the ability of the code to model the flight-path of interacting solid bodies in a hypersonic flow.

Airburst↗

Computational micromechanics of fatigue of microstructures in the HCF–VHCF regimes

Advances in higher resolution experimental techniques have shown that metallic materials can develop fatigue cracks under cyclic loading levels significantly below the yield stress. Indeed, the traditional notion of a fatigue limit can be recast in terms of limits associated with nucleation and arrest of fatigue cracks at the microstructural scale. Though fatigue damage characteristically emerges from irreversible dislocation processes at sub-grain scales, the specific microstructure attributes, environment, and loading conditions can strongly affect the apparent failure mode and surface to subsurface transitions. This paper discusses multiple mechanisms that occur during fatigue loading in the high cycle fatigue (HCF) to very high cycle fatigue (VHCF) regimes. We compare these regimes, focusing on strategies to bridge experimental and modeling approaches exercised at multiple length scales and discussing particular challenges to modeling and simulation regarding microstructure-sensitive fatigue driving forces and thresholds. Finally, we discuss some of the challenges in predicting the transition of failure mechanisms at different stress and strain amplitudes.

36 MATERIALS SCIENCE↗

The effect of CO 2 -induced dissolution on flow properties in Indiana Limestone: An in situ synchrotron X-ray micro-tomography study

The injection of CO 2 -rich fluids in carbonate rocks results in an evolution of the pore space, with consequent changes in the hydraulic properties of the reservoir; how these properties evolve, particularly for parameters relevant to multiphase flow e.g. P c (s), remains a topic of active research despite several decades of study. We have carried out an in situ synchrotron X-ray microtomography experiment to monitor pore structure evolution during dissolution of an Indiana Limestone core; the experiment involved flowing CO 2 -saturated water through the core for 36 h and resulted in 10 volumes corresponding to different temporal stages of the dissolution process. The injection parameters corresponded to the flow velocities expected near the well-bore region of a shallow aqueous CO 2 injection; fast flow rates with high reactant availability. Analysis of the tomographic data shows flow-enhanced dissolution i.e. channeling, and provides a time-resolved map of pore space alteration. Using the resulting 4D pore space volume, we modeled the evolution of capillary-pressure curves; this exercise demonstrates how pore structure evolution could impact the invasion and remobilization of non-wetting fluids, dramatically decreasing the entry pressure and the P C in some parts of the sample. The modeling of permeability, using a Stokes solver approach, quantified the relationship of porosity vs. permeability; we found that a modest increase in porosity, especially when the channeling system is more developed, greatly affects permeability. Furthermore, these results demonstrate how movement of CO 2 saturated brine near injected plumes might alter drainage dynamics near the plume boundary, thus leading to mobilization across subtle capillary barriers.

58 GEOSCIENCES↗

Ignition and flame characteristics of cryogenic hydrogen releases

In this work, under-expanded cryogenic hydrogen jets were investigated experimentally for their ignition and flame characteristics. The test facility described herein, was designed and constructed to release hydrogen at a constant temperature and pressure, to study the dispersion and thermo-physical properties of cryogenic hydrogen releases and flames. In this study, a non-intrusive laser spark focused on the jet axis was used to measure the maximum ignition distance. The radiative power emitted by the corresponding jet flames was also measured for a range of release scenarios from 37 K to 295 K, 2–6 bar abs through nozzles with diameters from 0.75 to 1.25 mm. The maximum ignition distance scales linearly with the effective jet diameter (which scales as the square root of the stagnant fluid density). A 1-dimensional (stream-wise) cryogenic hydrogen release model developed previously at Sandia National Laboratories (although this model is not yet validated for cryogenic hydrogen) was exercised to predict that the mean mole fraction at the maximum ignition distance is approximately 0.14, and is not dependent on the release conditions. The flame length and width were extracted from visible and infra-red flame images for several test cases. The flame length and width both scale as the square root of jet exit Reynolds number, as reported in the literature for flames from atmospheric temperature hydrogen. As shown in previous studies for ignited atmospheric temperature hydrogen, the radiative power from the jet flames of cold hydrogen scales as a logarithmic function of the global flame residence time. The radiative heat flux from jet flames of cold hydrogen is higher than the jet flames of atmospheric temperature hydrogen, for a given mass flow rate, due to the lower choked flow velocity of low-temperature hydrogen. Lastly, this study provides critical information with regard to the development of models to inform the safety codes and standards of hydrogen infrastructure.

08 HYDROGEN↗

Mixing and warming of cryogenic hydrogen releases

Laboratory measurements were made on the concentration and temperature fields of cryogenic hydrogen jets. Images of spontaneous Raman scattering from a pulsed planar laser sheet were used to measure the concentration and temperature fields from varied releases. Jets with up to 5 bar pressure, with near-liquid temperatures at the release point, were characterized in this work. This data is relevant for characterizing unintended leaks from piping connected to cryogenic hydrogen storage tanks, such as might be encountered at a hydrogen fuel cell vehicle fueling station. The average centerline mass fraction was observed to decay at a rate similar to room temperature hydrogen jets, while the half-width of the Gaussian profiles of mass fraction were observed to spread more slowly than for room temperature hydrogen. This suggests that the mixing and models for cryogenic hydrogen may be different than for room temperature hydrogen. Results from this work were also compared to a one-dimensional (streamwise) model. Good agreement was seen in terms of temperature and mass fraction. Furthermore, a validated version of this model will be exercised to quantitatively assess the risk at hydrogen fueling stations with cryogenic hydrogen on-site.

08 HYDROGEN↗

Design tool for estimating metal hydride storage system characteristics for light-duty hydrogen fuel cell vehicles

The U.S. Department of Energy (DOE) has developed the Framework model to simulate fuel cell-based light-duty vehicle operation for various hydrogen storage systems. This transient model simulates the performance of the storage system, fuel cell, and vehicle for comparison to DOE's Technical Targets using four drive cycles. Metal hydride hydrogen storage models have been developed for the Framework model. Despite the utility of this model, it requires that material researchers input system design specifications that cannot be easily estimated. To confront this challenge, a design tool has been developed that allows researchers to directly enter physical and thermodynamic metal hydride properties into a simple sizing module that then estimates the systems parameters required to run the storage system model. This design tool can also be used as a standalone MS Excel model to estimate the storage system mass and volume outside of Framework and compare it to the DOE Technical Targets. This model will be explained and exercised with existing hydrogen storage materials.

33 ADVANCED PROPULSION SYSTEMS↗

The simulation of 3D hypervelocity spallation using a hydrocode PAGOSA with FLIP+MPM

n this work, a hydrocode PAGOSA with FLIP+MPM is presented and exercised to investigate the fracture in ductile material. The merit of PAGOSA with FLIP+MPM to solve the advection problem is first illustrated by a solid piston periodically moving in a sealed tube with air. Furthermore, the ability of PAGOSA with FLIP+MPM to capture the fracture in material is shown by a simple stretching fracture in ductile material. In both of two benchmark problems, the PAGOSA results and analytical solutions are also presented for comparison. Then PAGOSA with FLIP+MPM is used to model complex spall in ductile material, which is a challenging problem in engineering applications. The convergences of PAGOSA with FLIP+MPM—based on both the mesh size and the marker density—are investigated by monitoring free surface velocity. To further show the ability of PAGOSA with FLIP+MPM to predict fracture in ductile material, the numerical results are compared with the experimental results and other published numerical results. Moreover, the effect of the spall parameter in PAGOSA with FLIP+MPM on the numerical simulation is also analyzed by investigating the free surface velocity. Finally, the effects of the peak compressive stress, the tensile strain rate, and the loading rate on the spallation are further investigated. The numerical results show that PAGOSA with FLIP+MPM can improve PAGOSA's performance when applied to predicting fracture in ductile materials, and is robust enough to accurately predict spall fracture in ductile materials.

42 ENGINEERING↗

Accelerated tert -butyloxycarbonyl deprotection of amines in microdroplets produced by a pneumatic spray

Protection and deprotection of organic compounds in multistep reactions using functional groups such as tert-butoxycarbonyl (Boc), is widely performed in synthetic organic chemistry. Reaction rate acceleration studies in spray-based ionization methods (electrosonic spray, paper spray, nanospray) have become increasingly common. In this report, we demonstrate reaction rate acceleration of Boc deprotection using easy ambient sonic-spray ionization (EASI), a pneumatic technique which does not involve an applied voltage, in a teaching laboratory setting. The goal of this laboratory exercise was to explore acceleration in a previously unexplored spray-based reaction, while emphasizing in a pedagogic setting the importance of protecting groups for multistep synthesis. Rate acceleration factors of more than an order of magnitude were observed in the uncharged micron-sized droplets generated by EASI. The effect of reaction conditions on reaction acceleration was examined including changes in the type of acid, reagent concentration ratios and syringe pump flow rates. Student knowledge was assessed by pre-laboratory assignments, post-laboratory reports and oral interviews.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Corrected Distortion model for Lagrangian spray simulation of transcritical fuel injection

In this work, we present a detailed implementation and validation of the droplet modeling framework proposed by Dahms and Oefelein (2016) into the engine commercial CFD software CONVERGE using the User Defined Function (UDF) interface. The model accounts for the nonlinear deformation and oscillation experienced by liquid spray droplet injected into high pressure and temperature. Lagrangian spray simulations of Engine Combustion Network (ECN) Spray A are performed. Model validation against standard experimental measurements of liquid velocity, vapor mixture fraction is conducted. To perform more rigorous model validation, new experimental measurements based on Diffused Back Illumination (DBI) are introduced. The new measurements are processed for Projected Liquid Volume (PLV), which offers as close as possible one-to-one model validation for liquid penetration while offering new insights into the spray physics. Comparison with a One-D model based on adiabatic mixing theory by Siebers (1999) and Desantes et al. (2007) are also conducted. Through these model validation exercises, it is shown that the new framework improves liquid-phase penetration predictions, following a tendency for enhanced evaporation, compared to the standard approach for both Reynolds Average Navier Stokes (RANS) and Large Eddy Simulation (LES). Additionally, at the liquid length, maximum mixture fraction values predicted by the new approach are in good agreement those of an adiabatic mixing model. Qualitative analysis of the spray behaviors during the early stage of the injection process reveals that the proposed framework predicts significant increase in droplet evaporation rate with lower drop drag compared to the current standard approach.

42 ENGINEERING↗

Comparative verification of hydro-mechanical fracture behavior: Task G of international research project DECOVALEX–2023

Numerical simulations become a necessity when experimental approaches cannot cover the required physical and time scale of interest. One of such area is a simulation of long-term host rock behaviors for nuclear waste disposal and simulation tools involved in the assessment must go through rigorous validation tests. The DECOVALEX project (Development of COupled models and their VAlidation against EXperiments) is dedicated to this purpose by international participants. This work is part of the ongoing phase DECOVALEX–2023 (D–2023, Task G) particularly aiming to simulate fracture behaviors under various conditions. Here, in this study, we cross-verified a variety of numerical methods including continuous and discontinuous approaches against four benchmark exercises with emphasis on numerical accuracy and parameterization of the various numerical approaches. The systematic inter-comparisons of test cases highlight advantages and disadvantages of the different numerical models. Numerical details on discretization effects (e.g. mesh density and orientation) and domain size were investigated in detail for practical applications. It became evident that meticulous attention to mesh resolution and domain size is imperative for achieving accurate numerical simulations, even for static cracks. Moreover, when comparing numerical methods to closed-form solutions for static cracks, all models successfully reproduced the maximum crack opening but encountered challenges near the crack tips. Finally, the paper discusses how to convert between and therefore compare parameters of various numerical approaches. Our benchmark studies reveal that each model necessitates a distinct number of parameters, even in simple scenarios like static crack aperture benchmarks. It is generally more practical to employ fewer parameters to mitigate model over-parameterization and enhance experimental feasibility.

58 GEOSCIENCES↗

Factors Associated With Long-Term Dysphagia After Definitive Radiotherapy for Locally Advanced Head-and-Neck Cancer

Purpose: The use of altered fractionation radiotherapy (RT) regimens, as well as concomitant chemotherapy and RT, to intensify therapy for locally advanced head-and-neck cancer can lead to increased rates of long-term dysphagia. Methods and Materials: We identified 122 patients who had undergone definitive RT for locally advanced head-and-neck cancer, after excluding those who had been treated for a second or recurrent head-and-neck primary, had Stage I-II disease, developed locoregional recurrence, had <12 months of follow-up, or had undergone postoperative RT. The patient, tumor, and treatment factors were correlated with a composite of 3 objective endpoints as a surrogate for severe long-term dysphagia: percutaneous endoscopic gastrostomy tube dependence at the last follow-up visit; aspiration on a modified barium swallow study or a clinical diagnosis of aspiration pneumonia; or the presence of a pharyngoesophageal stricture. Results: A composite dysphagia outcome occurred in 38.5% of patients. On univariate analysis, the primary site (p = 0.01), use of concurrent chemotherapy (p = 0.01), RT schedule (p = 0.02), and increasing age (p = 0.04) were significantly associated with development of composite long-term dysphagia. The use of concurrent chemotherapy (p = 0.01), primary site (p = 0.02), and increasing age (p = 0.02) remained significant on multivariate analysis. Conclusion: The addition of concurrent chemotherapy to RT for locally advanced head-and-neck cancer resulted in increased long-term dysphagia. Early intervention using swallowing exercises, avoidance of nothing-by-mouth periods, and the use of intensity-modulated RT to reduce the dose to the uninvolved swallowing structures should be explored further in populations at greater risk of long-term dysphagia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Oncology in Undergraduate Medical Education: A Literature Review

Purpose: To review the published literature pertaining to radiation oncology in undergraduate medical education. Methods and Materials: Ovid MEDLINE, Ovid MEDLINE Daily Update and EMBASE databases were searched for the 11-year period of January 1, 1998, through the last week of March 2009. A medical librarian used an extensive list of indexed subject headings and text words. Results: The search returned 640 article references, but only seven contained significant information pertaining to teaching radiation oncology to medical undergraduates. One article described a comprehensive oncology curriculum including recommended radiation oncology teaching objectives and sample student evaluations, two described integrating radiation oncology teaching into a radiology rotation, two described multidisciplinary anatomy-based courses intended to reinforce principles of tumor biology and radiotherapy planning, one described an exercise designed to test clinical reasoning skills within radiation oncology cases, and one described a Web-based curriculum involving oncologic physics. Conclusions: To the authors' knowledge, this is the first review of the literature pertaining to teaching radiation oncology to medical undergraduates, and it demonstrates the paucity of published work in this area of medical education. Teaching radiation oncology should begin early in the undergraduate process, should be mandatory for all students, and should impart knowledge relevant to future general practitioners rather than detailed information relevant only to oncologists. Educators should make use of available model curricula and should integrate radiation oncology teaching into existing curricula or construct stand-alone oncology rotations where the principles of radiation oncology can be conveyed. Assessments of student knowledge and curriculum effectiveness are critical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Drugs Enhance Hypofractionated Radiotherapy? A Novel Method of Modeling Radiosensitization Using In Vitro Data

Purpose: Hypofractionated radiotherapy (hRT) is being explored for a number of malignancies. The potential benefit of giving concurrent chemotherapy with hRT is not known. We sought to predict the effects of combined modality treatments by using mathematical models derived from laboratory data. Methods and Materials: Data from 26 published clonogenic survival assays for cancer cell lines with and without the use of radiosensitizing chemotherapy were collected. The first three data points of the RT arm of each assay were used to derive parameters for the linear quadratic (LQ) model, the multitarget (MT) model, and the generalized linear quadratic (gLQ) model. For each assay and model, the difference between the predicted and observed surviving fractions at the highest tested RT dose was calculated. The gLQ model was fitted to all the data from each RT cell survival assay, and the biologically equivalent doses in 2-Gy fractions (EQD2s) of clinically relevant hRT regimens were calculated. The increase in cell kill conferred by the addition of chemotherapy was used to estimate the EQD2 of hRT along with a radiosensitizing agent. For comparison, this was repeated using conventionally fractionated RT regimens. Results: At a mean RT dose of 8.0 Gy, the average errors for the LQ, MT, and gLQ models were 1.63, 0.83, and 0.56 log units, respectively, favoring the gLQ model (p < 0.05). Radiosensitizing chemotherapy increased the EQD2 of hRT schedules by an average of 28% to 82%, depending on disease site. This increase was similar to the gains predicted for the addition of chemotherapy to conventionally fractionated RT. Conclusions: Based on published in vitro assays, the gLQ equation is superior to the LQ and MT models in predicting cell kill at high doses of RT. Modeling exercises demonstrate that significant increases in biologically equivalent dose may be achieved with the addition of radiosensitizing agents to hRT. Clinical study of this approach is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Patients' Decision Aid for Older Women With Stage I Breast Cancer Considering Radiotherapy After Lumpectomy

Purpose: To develop a patient decision aid (PtDA) for older women with Stage I, pathologically node negative, estrogen receptor-positive progesterone receptor-positive breast cancer who are considering adjuvant radiotherapy after lumpectomy and to examine its impact on patients' decision making. Methods and Materials: A PtDA was developed and evaluated in three steps according to the Ottawa Decision Support Framework: (1) needs assessment (n = 16); (2) Pilot I to examine PtDA acceptability (n = 12); and (3) Pilot II, a pretest posttest (n = 38) with older women with estrogen receptor-positive progesterone receptor-positive breast cancer after lumpectomy who were receiving adjuvant radiation therapy. Measures included patients' satisfaction with the PtDA, self-reported decisional conflict, level of distress, treatment-related knowledge, and choice predisposition. Results: The PtDA is a booklet that details each adjuvant treatment option's benefits, risks, and side effects tailored to the patient's clinical profile; includes a values clarification exercise; and includes steps to guide patients towards their decision. On the basis of qualitative comments and satisfaction ratings, all women thought that the PtDA was helpful and informative. In comparison with their baseline scores, patients had a statistically significant (p < 0.05) reduction in decisional conflict (adjusted mean difference [AMD], -7.18; 95% confidence interval [CI], -13.50 to 12.59); increased clarity of the benefits and risks (AMD, -10.86; CI, -20.33 to 21.49); and improved general treatment knowledge (AMD, 8.99; CI, 2.88-10.28) after using the PtDA. General trends were also reported in the patients' choice predisposition scores that suggested potential differences in treatment decision after PtDA use. Conclusions: This study provides evidence that this PtDA may be a helpful educational tool for this group of women. The quality of care for older breast cancer patients may be enhanced by the use of a tailored PtDA to help patients be better informed about their treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contouring Variability of the Penile Bulb on CT Images: Quantitative Assessment Using a Generalized Concordance Index

Purpose: Within a multicenter study (DUE-01) focused on the search of predictors of erectile dysfunction and urinary toxicity after radiotherapy for prostate cancer, a dummy run exercise on penile bulb (PB) contouring on computed tomography (CT) images was carried out. The aim of this study was to quantitatively assess interobserver contouring variability by the application of the generalized DICE index. Methods and Materials: Fifteen physicians from different Institutes drew the PB on CT images of 10 patients. The spread of DICE values was used to objectively select those observers who significantly disagreed with the others. The analyses were performed with a dedicated module in the VODCA software package. Results: DICE values were found to significantly change among observers and patients. The mean DICE value was 0.67, ranging between 0.43 and 0.80. The statistics of DICE coefficients identified 4 of 15 observers who systematically showed a value below the average (p value range, 0.013 - 0.059): Mean DICE values were 0.62 for the 4 'bad' observers compared to 0.69 of the 11 'good' observers. For all bad observers, the main cause of the disagreement was identified. Average DICE values were significantly worse from the average in 2 of 10 patients (0.60 vs. 0.70, p < 0.05) because of the limited visibility of the PB. Excluding the bad observers and the 'bad' patients,' the mean DICE value increased from 0.67 to 0.70; interobserver variability, expressed in terms of standard deviation of DICE spread, was also reduced. Conclusions: The obtained values of DICE around 0.7 shows an acceptable agreement, considered the small dimension of the PB. Additional strategies to improve this agreement are under consideration and include an additional tutorial of the so-called bad observers with a recontouring procedure, or the recontouring by a single observer of the PB for all patients included in the DUE-01 study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiation Therapy of Liver Cancer

Purpose: To evaluate the dosimetric impact of rotational setup errors in stereotactic body radiotherapy (SBRT) treatment of liver tumors and to investigate whether translational shifts can compensate for rotation. Methods and Materials: The positioning accuracy in 20 patients with liver malignancies treated with SBRT was reevaluated offline by matching the patients' cone-beam computed tomography (CT) scans (n=75) to the planning CT scans and adjusting the 3 rotational angles (pitch, roll, and yaw). Systematic and random setup errors were calculated. The dosimetric changes caused by rotational setup errors were quantified for both simulated and observed patient rotations. Dose distributions recalculated on the rotated CT scans were compared with the original planned doses. Translational corrections were simulated based on manual translational registration of the rotated images to the original CT scans. The correction efficacy was evaluated by comparing the recalculated plans with the original plans. Results: The systematic rotational setup errors were -0.06 Degree-Sign {+-} 0.68 Degree-Sign , -0.29 Degree-Sign {+-} 0.62 Degree-Sign , and -0.24 Degree-Sign {+-} 0.61 Degree-Sign ; the random setup errors were 0.80 Degree-Sign , 1.05 Degree-Sign , and 0.61 Degree-Sign for pitch, roll, and yaw, respectively. Analysis of CBCT images showed that 56.0%, 14.7%, and 1.3% of treated fractions had rotational errors of >1 Degree-Sign , >2 Degree-Sign , and >3 Degree-Sign , respectively, in any one of the rotational axes. Rotational simulations demonstrated that the reduction of gross tumor volume (GTV) coverage was <2% when rotation was <3 Degree-Sign . Recalculated plans using actual patient roll motions showed similar reduction (<2%) in GTV coverage. Translational corrections improved the GTV coverage to within 3% of the original values. For organs at risk (OAR), the dosimetric impact varied case by case. Conclusion: Actual rotational setup errors in SBRT for liver tumors are relatively small in magnitude and are unlikely to affect GTV coverage significantly. Translational corrections can be optimized to compensate for rotational setup errors. However, caution regarding possible dose increases to OAR needs to be exercised.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable Image Registration for Adaptive Radiation Therapy of Head and Neck Cancer: Accuracy and Precision in the Presence of Tumor Changes

Purpose: To compare deformable image registration (DIR) accuracy and precision for normal and tumor tissues in head and neck cancer patients during the course of radiation therapy (RT). Methods and Materials: Thirteen patients with oropharyngeal tumors, who underwent submucosal implantation of small gold markers (average 6, range 4-10) around the tumor and were treated with RT were retrospectively selected. Two observers identified 15 anatomical features (landmarks) representative of normal tissues in the planning computed tomography (pCT) scan and in weekly cone beam CTs (CBCTs). Gold markers were digitally removed after semiautomatic identification in pCTs and CBCTs. Subsequently, landmarks and gold markers on pCT were propagated to CBCTs, using a b-spline-based DIR and, for comparison, rigid registration (RR). To account for observer variability, the pair-wise difference analysis of variance method was applied. DIR accuracy (systematic error) and precision (random error) for landmarks and gold markers were quantified. Time trend of the precisions for RR and DIR over the weekly CBCTs were evaluated. Results: DIR accuracies were submillimeter and similar for normal and tumor tissue. DIR precision (1 SD) on the other hand was significantly different (P<.01), with 2.2 mm vector length in normal tissue versus 3.3 mm in tumor tissue. No significant time trend in DIR precision was found for normal tissue, whereas in tumor, DIR precision was significantly (P<.009) degraded during the course of treatment by 0.21 mm/week. Conclusions: DIR for tumor registration proved to be less precise than that for normal tissues due to limited contrast and complex non-elastic tumor response. Caution should therefore be exercised when applying DIR for tumor changes in adaptive procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗