Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Operating Characteristics of Metal Hydride-Based Solar Energy Storage Systems

Thermochemical energy storage systems, based on a high-temperature metal hydride coupled with a low-temperature metal hydride, represent a valid option to store thermal energy for concentrating solar power plant applications. The operating characteristics are investigated for a tandem hydride bed energy storage system, using a transient lumped parameter model developed to identify the technical performance of the proposed system. The results show that, without operational control, the system undergoes a thermal ratcheting process, causing the metal hydride concentrations to accumulate hydrogen in the high-temperature bed over time, and deplete hydrogen in the low temperature. This unbalanced system is compared with a ’thermally balanced’ system, where the thermal ratcheting is mitigated by thermally balancing the overall system. The analysis indicates that thermally balanced systems stabilize after the first few cycles and remain so for long-term operation, demonstrating their potential for practical thermal energy storage system applications.

25 ENERGY STORAGE↗

Model, Design, and Control for Power Conversion in Wave Energy Converter System

Wave energy, if all been harvested along the U.S. coastline, can power around 65% of the energy consumption in U.S.. Comparing to other renewable energy sources like solar or wind, ocean wave can provide up to 90% of steady uptime. With the high energy density (2-3 kW/m 2 ), it can produce more energy with the same amount of installation area comparing to the energy density of wind turbine (0.6 kW/m 2 ) and solar panel(0.2 kW/m 2 ). The predictability of wave provides advantages like planning installation, power dispatching, and maintenance activities. Although with all these advantages, wave energy converter system is still in the research stage due to its high system cost per electricity production. One of the challenges that need to be solved is the irregularity from the wave motion that leads to high instantaneous peak power into the wave energy converter, which usually reaches up to 10 - 20 times of the average power. The high peak power will not only bring high mechanical/electrical stress but also result in an overrating design of the components in the system. Another obstacle that prevents the wave energy system from moving forward is the high testing cost from the validations in wave-energy-test sites or tank-test sites. A high-fidelity multi-disciplinary system model, including hydrodynamics, mechanical dynamics, electromagnetics, and power electronics, is needed to predict the behavior of the system and reduce the cost of design validation.

16 TIDAL AND WAVE POWER↗

Renewable Energy at NASA's Johnson Space Center

NASA's Johnson Space Center has implemented a great number of renewable energy systems. Renewable energy systems are necessary to research and implement if we humans are expected to continue to grow and thrive on this planet. These systems generate energy using renewable sources - water, wind, sun - things that we will not run out of. Johnson Space Center is helping to pave the way by installing and studying various renewable energy systems. The objective of this report will be to examine the completed renewable energy projects at NASA's Johnson Space Center for a time span of ten years, beginning in 2003 and ending in early 2014. This report will analyze the success of each project based on actual vs. projected savings and actual vs. projected efficiency. Additionally, both positive and negative experiences are documented so that lessons may be learned from past experiences. NASA is incorporating renewable energy wherever it can, including into buildings. According to the 2012 JSC Annual Sustainability Report, there are 321,660 square feet of green building space on JSC's campus. The two projects discussed here are major contributors to that statistic. These buildings were designed to meet various Leadership in Energy and Environmental Design (LEED) Certification criteria. LEED Certified buildings use 30 to 50 percent less energy and water compared to non-LEED buildings. The objectives of this project were to examine data from the renewable energy systems in two of the green buildings onsite - Building 12 and Building 20. In Building 12, data was examined from the solar photovoltaic arrays. In Building 20, data was examined from the solar water heater system. By examining the data from the two buildings, it could be determined if the renewable energy systems are operating efficiently. Objectives In Building 12, the data from the solar photovoltaic arrays shows that the system is continuously collecting energy from the sun, as shown by the graph below. Building 12 has two solar inverters, located on the second floor, that collected the data from the solar photovoltaic arrays. The data displayed here is the total energy produced by the system. These are cumulative amounts, so the last point on the graph shows all of the energy collected from the system since the start of its operation. The data shown here was manually collected from the solar inverters. However, the data is also automatically recorded through EBI. Through analysis of both sets of data it was determined that the EBI data was faulty. For example, from the manually collected data it can be determined that a total of 73 kWh of energy was collected between the dates of 1/16/2014 – 1/22/2014. The EBI data reports that approximately 17800 kWh of energy was collected during the same time frame. Not only does this exceed the time frame examined, but it also exceeds the total energy collected from the start of collection as recorded from the inverters. This leads to the belief that there is a malfunction with the automatic recording of the energy. In Building 20, data was examined from the solar water heater dating back many months and found that the pump for the solar water heater system was not operating properly, as exhibited in the graph shown below. The pump operates on a solar energy system, meaning that it collects energy throughout the day from the sun. Because of this, the system would stop operating shortly after the sun set because of a lack of sunlight. At that point, the graph should show a zero flow rate, but as exhibited in the graph below, that is not the case. It is clearly shown that the pump is continuously operating, even during the night. It was also observed that the majority of the time the pump would not turn on at all, despite good weather conditions. This led to the conclusion that the pump is malfunctioning, and needs to be examined and fixed.

McDowall, Lindsay↗

Electrochemical energy storage systems

Electrochemical energy storage systems are crucial components for the realization of a carbon-neutral/carbon-negative energy sector globally. Industrial applications require energy storage technologies that cater to a wide range of specifications in terms of form factor, gravimetric and volumetric energy density, charging rates, and safety, among others. The key electrochemical technologies for industrial applications are supercapacitors and batteries. Supercapacitors are high-power devices while batteries typically cater to high energy density requirements. This chapter provides an in-depth understanding of these technologies in terms of materials, processing, working principle, and architecture. Subsequently, state-of-the-art of these technologies is discussed with an emphasis on materials, manufacturing, and end-use systems. Finally, emerging technologies in the electrochemical energy storage field are highlighted.

Dixit, Marm↗

A Novel Framework for Optimizing Ramping Capability of Hybrid Energy Storage Systems

Hybrid Energy Storage System has been widely applied in aerospace, electric vehicle, and microgrid applications. The advantages are that they include complimentary technologies with both high power and energy capabilities. HESS have the potential to be useful to the bulk power systems, for example to increase the value of energy produced by variable generation resource through enabling participation in ancillary service markets. Actualizing the benefits of HESSs requires optimizing the combined ramping capability of aggregated HESS resources. To provide quality ancillary service, source of HESSs locating at multiple sites of variable generation resource must be optimally sized and cohesively controlled. Optimizing aggregated resources can be formulated as an optimization problem. Successfully solving this problem not only requires using effective solution methods but also depends on accurately and rapidly setting the necessary parameters in the problem formula. This article proposes a novel framework with double-layer structure to solve the optimization problem of aggregating ramping capability. Program developed on the upper layer focuses on solving the optimization of aggregating ramping capability among multiple HESSs and is compatible with most existing optimization algorithms. Program on lower layer of the framework targets at optimizing the local control of a single HESS based on a thorough analytics of HESS operation strategy presented in this article. Result of local optimization is also provided to upper layer program for updating the parameters in formula of optimization problem. Real time hardware-in-the-loop test is conducted to verify the performance of the optimization framework developed. The work presented is expected to provide guidance for implementing this framework in practical operation.

Luo, Yushen↗

Design and testing of high-performance mini-channel graphite heat exchangers in thermoelectric energy recovery systems

Recent national energy usage studies by Lawrence Livermore National Laboratory in 2015 [1] show that there is approximately 59 Quads (1015 Btu’s) of waste thermal energy throughout various industrial, residential, power generation, and transportation sectors of the U.S. economy. Thermoelectric energy recovery is one important technology for recovering this waste thermal energy in high-temperature industrial, transportation and military energy systems. Thermoelectric generator (TEG) systems in these applications require high performance hot-side and cold-side heat exchangers to provide the critical temperature differential and transfer the required thermal energy. High performance hot-side heat exchangers in these systems are often metal-based due to requirements for high-temperature operation, strength at temperature, corrosion resistance, and chemical stability. However, the generally selected metal-based hot-side heat exchangers (i.e., Inconels, Stainless Steels) suffer from low thermal conductivity, high thermal expansion, and high density, which degrades their thermal performance, leads to high thermal-expansion-driven stresses, and creates relatively high mass/high volume (i.e., low power density) TEG systems that are then difficult to fabricate and integrate into viable energy recovery systems. This paper describes the design and testing of a new, high-temperature minichannel graphite heat exchanger designed for operation up to 500C that is a critical element of a high-power-density TEG power system for aircraft energy recovery. This high-performance graphite heat exchanger represents a new state-of-the-art standard in high-temperature heat exchangers for TEG systems, which provides higher thermal transport, less thermal expansion at operation, lower system level stresses on TE components, and a lighter weight TEG system. This new heat exchanger creates a new design paradigm in TEG system design for terrestrial energy recovery and potential NASA technology infusion into terrestrial energy system applications. This paper will present and discuss the key heat transfer, pressure drop, pumping power analyses and design tradeoffs that created this unique design. Heat transfer and pressure drop modeling was performed with both empirical models based on known heat transfer and friction factor correlations and COMSOL thermal/fluid dynamic modeling of the graphite heat exchanger structure. We will also discuss resulting thermal transport and heat fluxes predicted at the TEG interface level. Heat exchanger performance testing was performed under simulated operating conditions and correlation with test data at the anticipated operating temperature conditions will be presented and discussed.

Shevade, Abhijit↗

High temperature underground thermal energy storage system for solar energy

The activities feasibility of high temperature underground thermal storage of energy was investigated. Results indicate that salt cavern storage of hot oil is both technically and economically feasible as a method of storing huge quantities of heat at relatively low cost. One particular system identified utilizes a gravel filled cavern leached within a salt dome. Thermal losses are shown to be less than one percent of cyclically transferred heat. A system like this having a 40 MW sub t transfer rate capability and over eight hours of storage capacity is shown to cost about $13.50 per KWh sub t.

Collins, R. E.↗