Accelerated Fuel Qualification of Fast Modular Reactor Fuel in a Thermal Reactor: Modeling and Simulation Paired with Irradiation Testing

The accelerated fuel qualification (AFQ) methodology is applied by simulating accelerated fuel tests of the General Atomics Electromagnetic Systems’ fuel system for its 44-MW(electric) gas-cooled, fast-spectrum fast modular reactor (FMR). This fuel is comprised of UO 2 pellets in SiGA® cladding, a silicon carbide ceramic matrix composite. Fast reactors, like the FMR, offer many benefits, including high fuel utilization and flexibility, but may require a lengthy material design process if tests are performed using fast neutron irradiation alone. A thermal neutron irradiation can instead be used to rapidly test how well key components of the current material models extend to high burnup. Thermal neutrons produce a different radial power distribution within the pin than fast neutrons. However, the temperature and burnup values for the two neutron types are comparable, and the differences between the simulated fuel responses are relatively small, demonstrating the weak sensitivity of the physics-based fuel model calculations on the neutron type and the irradiation rate. Furthermore, the deformation of the SiGA cladding saturates after about 1 displacement per atom for both neutron spectra. In an accelerated fuel test, the irradiation time required to reach the target fuel burnup can be reduced by a factor of 3 by using a small rodlet with a 45% smaller pellet diameter while maintaining the same linear power. Therefore, the time for data collection up to high burnup can be significantly reduced while maintaining the same temperature profile, which largely determines the material response. Tests of fuel rodlets of standard and compact size will be carried out in the Idaho National Laboratory’s Advanced Test Reactor (ATR), including full size and compact rodlets with varying gap sizes. By applying physics-based mechanistic modeling and simulation in accordance with the AFQ methodology, this type of compact rodlet testing in a thermal test reactor captures the necessary phenomena to test fuel material models up to high burnup and to simulate the expected impact of fast neutron radiation on the fuel in FMR operations. Finally, this approach to testing fast reactor fuels in existing thermal test reactors, paired with advanced physics-based mechanistic modeling and simulation, is expected to be applicable to a range of advanced fuels and will decrease the overall fuel qualification timeframe from decades to years.

Advanced test reactor (ATR)

Dynamic Modeling of a Fast Spectrum Molten Salt Reactor Integrated Energy System

Liquid-fueled molten salt fast reactors and nuclear-powered integrated energy systems (IESs) have the potential to play a pivotal role in the green energy transition. However, these systems have little to no operating experience. There is therefore increased interest and value in modeling and simulating these systems. The IES dynamic model developed in this work utilizes a lumped-parameter control volume methodology to investigate the behavior of the IES in a variety of accident scenarios. The results provide initial evidence for the potential inherent safety of the advanced reactor because of temperature-dependent reactivity feedback and the efficiency of hydrogen and electricity production at the high temperatures provided by the advanced reactor.

MCFR

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION

Transportation in net-zero emissions futures: Insights from the EMF-37 model intercomparison study

Transportation is currently the largest source of U.S. anthropogenic CO 2 emissions, at about a third of the total. Achieving net-zero emissions by mid-century will require substantial reductions in transportation emissions across passenger and freight travel. Here we leverage a model intercomparison study to explore the role of transportation in scenarios achieving net-zero economy-wide CO 2 emissions by 2050. We find the transport sector is poised to play the most significant role in reducing demand-side emissions, mostly driven by technology substitution, as modeling results suggest a limited role for mode shifting and for reduced use of personal car travel in the U.S. Among various technology solutions, models show agreement that passenger on-road vehicles will largely transition to electric vehicles (EVs), while solutions to decarbonize heavier travel modes are more diverse and include greater use of liquid biofuels and hydrogen. Research should continue to investigate the evolution of on-road electrification, the role of biofuels and hydrogen across heavier travel modes, and the role of mode shifting and travel behavior change to support personal transportation decarbonization at national and regional scales to temper the rapid growth in clean fuel and electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY

EM-Enhanced HyPOR Loop for Fast Fusion Cycles

Vacuum pumps are the heart of a fusion energy facility – fusion power cannot be generated without them. Nevertheless, the vacuum technology needed to operate a viable fuel cycle for a compact fusion power plant does not exist. Commercial vacuum technology offers the best solution to this challenge, but a pump oil recycling and detritiation system is necessary. Conventional oil detritiation processes have only been developed to deal with legacy waste and are too slow and destructive to the oil. Further, post hoc detritiation strategies are intrinsically inefficient. Our approach is to rethink the challenge holistically by designing the pumping fluid and tritium extraction system in an integrated manner to achieve an innovative solution. By selecting an oil for the specific task of pumping tritium and then designing our catalytic system to selectively target the tritium-bearing functional groups, an effective detritiation system (hydrocarbon pump oil recycling, HyPOR, loop) for fusion power plants can be obtained. The project demonstrated a HyPOR loop process that can selectively remove heavier hydrogen isotopes from pump oil, reaching the target of 99.5 % removal, with an uptake of less than 0.01% of tritium throughput, while also purifying the oil of radiation-induced damage. The recycled oil retained its pumping characteristics over 7 recycles and gamma irradiation over 30 MGy. By meeting these targets, the project enable a reduction in pump operational costs from $\$$14.5M/year to $\$$103k/year (>140× reduction), reducing pump electric power consumption from 2.8 MW to 0.25 MW (>10× reduction), and reducing in-process tritium inventory from 2.03 kg to 0.48 kg (>4× reduction).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Experimental study of airpath electrification in an opposed-piston two stroke (OP2S) engine architecture

The opposed-piston two stroke (OP2S) engine shows potential as an alternative engine architecture to the conventional four stroke engine due to its high-power density, thermal efficiency, and versatile airpath management system. Since the pistons of a two-stroke engine do not pump the air into and out of the cylinder like in a four-stroke engine, the selection of the air induction devices and airpath actuators becomes critical to optimize engine performance. Both the pumping losses and the in-cylinder combustion process can be affected by the scavenging process in a two-stroke engine. Therefore, this study compares two different airpath configurations for the same family of OP2S engines and investigates performance metrics like scavenging control, pumping work, net indicated and brake efficiencies, and engine-out emissions associated with each airpath. Data was collected on a 3.2 L, two-cylinder OP2S engine with an electrically assisted turbocharger (EAT) and a 4.9 L displacement, three-cylinder engine with a variable geometry turbocharger (VGT) and a supercharger. The experiments consisted of speed and load sweeps for both engines at the same operating conditions to compare scavenge control in both architectures. For the three-cylinder layout, the SE sweep range was much higher, and the intake pressure could be independently varied with air flowrate, thus providing more flexibility for scavenging control. The supercharger and the VGT usage was optimized based on its efficiency map and thus, this layout had lower pumping losses compared to the EAT. The two-cylinder engine had a higher overall SE as compared to the three-cylinder engine, but the intake pressure and air flowrate could not be decoupled, leading to over scavenging and increased short circuiting of fresh charge into the exhaust.

Bhatt, Ankur [Clemson University, Clemson, SC, USA

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION

Optimal Control of SOEC-Based Hydrogen Production Systems for Demand Response Using Deep Reinforcement Learning in Smart Grids

Solid oxide electrolysis cell (SOEC) hydrogen production technology can range in size from small, appliance-size equipment to large-scale, central production facilities that can be tied directly to renewable or non-greenhouse-gas-emitting forms of electricity production, making it an ideal resource for demand response (DR). The SOEC hydrogen production system is a complex integrated system that encompasses fluid dynamics, electrical dynamics, and electrochemical and thermal dynamics, all of which involve non-linearity and non-convexity. Proper control of the SOEC hydrogen production system is crucial to enable its participation in the DR program. Here, to overcome the difficulty of designing an explicit control law for such nonlinear systems with nonconvex optimization features in DR applications, deep reinforcement learning (DRL) is explored to achieve the optimal control of the SOEC system for DR participation. Specifically, a twin delayed deterministic policy gradient (TD3) control framework is applied to achieve optimal response performance during DR events by considering power tracking error and hydrogen production efficiency with a suitable reward function. Two case studies with grid connections for tracking different DR commands were investigated. The first case study involved operating conditions reaching the boundaries, while the second involved operating conditions within the boundaries. The results showed that the proposed DRL-based control for SOEC can track the DR signal in a timely manner while maintaining high energy efficiency.

08 HYDROGEN

Sustainable Valorization of CO2 through Nuclear Power-to-X Pathways

Some of the issues concerning energy security and climate change can be addressed by employing nuclear power (NP) to supply the energy required for the conversion of carbon dioxide (CO2) into chemicals, products, and materials. Nuclear energy represents a neutral carbon source that can be generated sustainably, reliably, and consistently. Nuclear power plants (NPPs) could supply energy in the form of heat, electricity, and ionizing radiation to drive CO2 chemical reactions underpinning NP-to-X type of pathways. CO2 conversion processes are either commercially available or emerging technologies at different developmental maturity stages. This work reviews the published literature (articles and patents) that reports R&D results and the understanding and development of chemical reactions and processes, as well as the efforts in integrating NPPs and chemical processes (CPs). As will be made evident, a new industrial era for the manufacturing of decarbonized chemicals, products, and materials will be possible by developing and implementing new (more energy- and carbon-efficient) processes responding to the NP-to-X pathways. This new decarbonizing platform not only contributes to achieving net zero goals but also broadens the NPP product beyond electricity.

08 HYDROGEN

Architecture for Web-Based Visualization of Large-Scale Energy Domains: Preprint

With the growing penetration of inverter-based distributed energy resources and increased loads through electrification, power systems analyses are becoming more important and more complex. Moreover, these analyses increasingly involve the combination of interconnected energy domains with data that are spatially and temporally increasing in scale by orders of magnitude, surpassing the capabilities of many existing analysis and decision-support systems. We present the architectural design, development, and application of a high-resolution web-based visualization environment capable of cross-domain analysis of tens of millions of energy assets, focusing on scalability and performance. Our system supports the exploration, navigation, and analysis of large data from diverse domains such as electrical transmission and distribution systems, mobility and electric vehicle charging networks, communications networks, cyber assets, and other supporting infrastructure. We evaluate this system across multiple use cases, describing the capabilities and limitations of a web-based approach for high-resolution energy system visualizations.

grid modernization

Nuclear Thermal Energy Storage Configurations for Industrial Combined Heat and Power Supply: Conceptual Study and Engineering Designs

The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Smart Adaptive Structures for an Ocean Wave Energy Converter

Ocean wave energy converters face significant challenges including cost-effectiveness, minimizing maintenance requirements, and withstanding extreme conditions. However, by utilizing smart materials, these converters could overcome these challenges. Such energy harvesters could use dielectric elastomer generators to convert ocean wave energy into electricity through their dynamic straining. Conversely, by applying electricity to these generators, they become actuators - dielectric elastomer actuators - thereby enabling them to alter their stiffness and adapt to the ever-changing ocean energy environments. Such active adaptation could enhance the converter's ability to: reach resonance with ocean waves and protect itself from dangerous waves. This study utilizes numerical analyses through the COMSOL software framework to evaluate the potential energy that could be harvested by a conceptual ocean wave energy converter based upon dielectric elastomer generators/actuators. The converter is composed of an external hull (that is a hollow cylinder), an inertial mass (that is a hollow cylinder and concentric with the hull), and 'spokes' - made of dielectric elastomer generators/actuators - that connect the hull to the inertial mass. Results of the numerical analyses include those outcomes arising from the conceptual converter being simulated via a sinusoidal motion analogous to ocean waves. That motion, therefore, causes relative motion between the converter's hull and inertial mass thereby dynamically stretching the corresponding connecting elastomers. The stretching of the elastomers enables them to 'gain elastic strain energy' and is, therefore, considered to be the theoretical limit of possible electrical energy conversion for the dielectric elastomer generator/actuator spokes. Additionally, the elastomer material properties of the spokes were altered to simulate the actuation of those same elastomers; with overall strain energy being subsequently investigated. Ultimately this is a preliminary study exploring the ability of such smart materials - electricity-generating and self-actuating elastomers - to actively adapt an ocean wave energy converter's structure to address and overcome the aforementioned challenges.

active materials

Estimates of the Economic Impacts of Long-Duration, Widespread Power Disruptions in Puerto Rico

A typical electricity customer in Puerto Rico experienced nearly 27 hours of power interruptions in 2023–with many customers experiencing extremely long duration outages during a single event (i.e., greater than one month). This project involved conducting state-of-the-art surveying to assess the direct costs of power outages occurring across Puerto Rico, developing customer-specific models to estimate future costs over varying outage durations, and comparing these estimates to FEMA’s Value of Unit Service for Electricity. We estimate that a territory-wide power outage may cost customers $\$1$, $\$5$ and $\$29$ billion during one-, 14-, and 30-day interruptions, respectively. However, these are lower-bound estimates because our study focused on direct economic costs and, by necessity, did not fully incorporate (1) indirect impacts to the economy; (2) costs to repair or replace damaged utility infrastructure; and (3) the broader societal consequences including increased morbidity- and mortality-related costs. The information contained in this study can be used to estimate the direct economic value of past or proposed investments in power system resilience. We conclude with a discussion of this study’s limitations and suggest additional research to improve stakeholder understanding of the impacts of power outages across Puerto Rico.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION

Evaluation of IEC 62443 Standard Gaps for Electric Grid Substation Model Use Case

This report presents an evaluation of the IEC 62443 standards in the context of electric grid substations, as part of a collaborative effort among Sandia National Laboratories (SNL), Idaho National Laboratory (INL), and the National Renewable Energy Laboratory (NREL). The primary objective is to assess the applicability of these standards to enhance cybersecurity measures for industrial automation and control systems (IACS) within the energy sector. The evaluation identifies strengths, such as the scalability of security levels and the structured lifecycle guidance provided by IEC 62443. However, it also highlights significant gaps, including limited integration of physical security, insufficient guidance for legacy systems, and challenges in addressing emerging threats like supply chain vulnerabilities. Recommendations for refining the standards are proposed, including the need for tailored guidance for securing legacy systems, integrating physical security with cybersecurity frameworks, and enhancing interoperability across multi-vendor environments. By addressing these gaps, the IEC 62443 standards can be strengthened to ensure comprehensive cybersecurity for electric grid substations, thereby supporting the resilience and reliability of critical energy infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION

A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

This paper presents the design of a single-phase, single-stage line impedance stabilization network (LISN) for medium-voltage (MV) applications. More than 1 kV rated widebandgap (WBG) power semiconductor switches are increasingly utilized in new, emerging power electronics energy systems to improve power density and efficiency. However, due to inherently fast-switching speeds, WBG switch modules emit considerable electromagnetic interference (EMI) (e.g., common mode (CM) or differential mode (DM)). State-of-the-art offers standardized LISN solutions to validate and certify the new energy system for electromagnetic compatibility (EMC). However, most are for low voltage applications (i.e., < 1 kV). MV LISNs (i.e., > 1 kV) are rare until recently and literature does not provide sufficient guidelines for designing and characterizing such devices. It has been a critical challenge for many scientists and engineers to reliably certify the emerging MV energy systems (e.g., electric ships and aircraft). This paper addresses such a technology gap. Specifically, a CISPR 16-1-2 compliant 50Ω/50μH LISN with 1.5kV, 75A and 30MHz measurement capability has been proposed. Detailed performance study versus non-linear parasitic parameters variations in MV inductors and capacitors have been done. Based on new understandings, novel techniques to intuitively mitigate unwanted parasitic have been proposed to develop the proposed LISN successfully. Thorough characterization of important LISN parameters are presented and factors influencing them are analyzed. A rigorous analysis, experimental tests, and in-depth comparisons over state-of-the-art have been made to validate the effectiveness. This is done through the state-of-the-art 300kVA MV EMI testbed.