Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Morphological Changes in the Retina Under Conditions of Experimental In Vivo Regional Ischemia/Reperfusion

Two models of retinal ischemia/reperfusion were developed in an experiment on rats and structural changes in eye tissues in the early and late postischemic periods were studied. Ischemia/reperfusion was modeled by elevation of intraocular pressure to 110 mm Hg for 30 min with air injection into the anterior chamber of the eye with a special device or subconjunctival administration of 0.2 ml 4×10{sup –6} M endothelin-1. Morphological studies of the retina of enucleated eyes were performed in 3, 7, and 30 days after ischemia/reperfusion. In 3 days, signs of retinal ischemia were seen (retinal edema and ganglion cell damage). In the late post-ischemic period (30 days), atrophy of the outer nuclear and outer plexiform layer of the retina was observed in animals with retinal ischemia/reperfusion caused by intraocular pressure elevation and complete destruction of neuronal cells was found after administration of endothelin-1.

60 APPLIED LIFE SCIENCES↗

Variable Circular Collimator in Robotic Radiosurgery: A Time-Efficient Alternative to a Mini-Multileaf Collimator?

Purpose: Compared with many small circular beams used in CyberKnife treatments, beam's eye view-shaped fields are generally more time-efficient for dose delivery. However, beam's eye view-shaping devices, such as a mini-multileaf collimator (mMLC), are not presently available for CyberKnife, although a variable-aperture collimator (Iris, 12 field diameters; 5-60 mm) is available. We investigated whether the Iris can mimic noncoplanar mMLC treatments using a limited set of principal beam orientations (nodes) to produce time-efficient treatment plans. Methods and Materials: The data from 10 lung cancer patients and the beam-orientation optimization algorithm 'Cycle' were used to generate stereotactic treatment plans (3 x 20 Gy) for a CyberKnife virtually equipped with a mMLC. Typically, 10-16 favorable beam orientations were selected from 117 available robot node positions using beam's eye view-shaped fields with uniform fluence. Second, intensity-modulated Iris plans were generated by inverse optimization of nonisocentric circular candidate beams targeted from the same nodes selected in the mMLC plans. The plans were evaluated using the mean lung dose, lung volume receiving {>=}20 Gy, conformality index, number of nodes, beams, and monitor units, and estimated treatment time. Results: The mMLC plans contained an average of 12 nodes and 11,690 monitor units. For a comparable mean lung dose, the Iris plans contained 12 nodes, 64 beams, and 21,990 monitor units. The estimated fraction duration was 12.2 min (range, 10.8-13.5) for the mMLC plans and 18.4 min (range, 12.9-28.5) for the Iris plans. In contrast to the mMLC plans, the treatment time for the Iris plans increased with an increasing target volume. The Iris plans were, on average, 40% longer than the corresponding mMLC plans for small targets (<80 cm{sup 3}) and {<=}121% longer for larger targets. For a comparable conformality index, similar results were obtained. Conclusion: For stereotactic lung irradiation, time-efficient and high-quality plans were obtained for robotic-controlled noncoplanar treatments using a mMLC. Iris is a time-efficient alternative for small targets, with similar or better plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrothermal crystal growth, piezoelectricity, and triboluminescence of KNaNbOF{sub 5}

Single crystals of the noncentrosymmetric KNaNbOF{sub 5} polymorph were grown for piezoelectric and triboluminescent measurements. Piezoelectric measurements yielded a d{sub 33} value of ±6.3 pCN{sup −1} and an effective electromechanical coupling coefficient of up to 0.1565 in the frequency range 1960–2080 kHz. Crystals of KNaNbOF{sub 5} were found to exhibit a strong triboluminscence effect visible to the naked eye as blue sparks when crystals are crushed. This triboluminescence effect is uncommon in that it is likely independent from both the piezoelectric effect and atmospheric electrical discharge. Instead, triboluminescence may originate from crystal defects or be related to an electroluminescence effect. - Graphical abstract: An optical emission visible to the naked eye as blue sparks is observed when KNaNbOF{sub 5} single crystals are fractured. - Highlights: • Single crystals of KNaNbOF{sub 5} were grown under hydrothermal conditions. • Piezoelectric and triboluminescent properties were characterized. • Piezoelectric measurements yielded a d{sub 33} value of ±pCN{sup −1}. • KNaNbOF{sub 5} exhibits strong triboluminscence visible to the naked eye as blue sparks.

36 MATERIALS SCIENCE↗

ZIKA virus infection causes persistent chorioretinal lesions

Zika-infected patients can have eye involvement ranging from mild conjunctivitis to severe chorioretinal lesions, however the possible long-term sequelae of infection and timeline to recovery remain unknown. Here we describe the partial recovery of chorioretinal lesions in an immunocompetent patient diagnosed with bilateral posterior uveitis associated with Zika infection and show that some lesions resolved with focal atrophy evident as pigmentary changes on funduscopy. To better understand the progression of the lesions and correlate the changes in fundus imaging with local viral load, immune responses, and retinal damage, we developed a symptomatic mouse model of ocular Zika virus infection. Imaging of the fundus revealed multiple hypopigmentary patches indicative of chorioretinal degeneration as well as thinning of the retina that mirror the lesions in patients. Microscopically, the virus primarily infected the optic nerve, retinal ganglion cells, and inner nuclear layer cells, showing thinning of the outer plexiform layer. During acute infection, the eyes showed retinal layer disorganization, retinitis, vitritis, and focal choroiditis, with mild cellular infiltration and increased expression of tumor necrosis factor, interferon-γ, granzyme B, and perforin. Focal areas of gliosis and retinal degeneration persisted 60 dpi. The model recapitulates features of ZIKA infections in patients and should help elucidate the mechanisms underlying the damage to the eyes and aid in the development of effective therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

Improving optical performance of concentrator cells by means of a deposited nanopattern layer

Multijunction solar cells (MJSC) use anti-reflective coatings (ARC) to minimize Fresnel reflection losses for a family of light incidence angles. These coatings adapt the refractive index of the cell to that of the surrounding medium. Patterns with sizes in the range of the light wavelength can be used to further reduce reflections through diffraction. Transparent nanopatterns with a gradual profile, called moth-eye nanostructures, can adapt the refractive index of the optical interfaces (often with n∼1.5) used to encapsulate concentrator solar cells to that of the air (n{sub air}∼1). Here we show the effect of a nanometric moth-eye ARC with a round motif deposited on commercial MJSC that achieves short-circuit current (I{sub SC}) gains greater than 2% at normal incidence and even higher in the case of tilted illumination. In this work, MJSC with different moth-eye ARC are characterized under quantum efficiency (QE) as well as under concentrated illumination I-V in order to assess their potential. Simulations based on coupled wave analysis (RCWA) are used to fit the experimental results with successful results.

14 SOLAR ENERGY↗

Controlled release of cortisone drugs from block copolymers synthetized by ATRP

Diseases affecting posterior eye segment, like macular edema, infection and neovascularization, may cause visual impairment. Traditional treatments, such as steroidal-drugs intravitreal injections, involve chronic course of therapy usually over a period of years. Moreover, they can require frequent administrations of drug in order to have an adequately disease control. This dramatically reduce patient’s compliance. Efforts have been made to develop implantable devices that offer an alternative therapeutic approach to bypass many challenges of conventional type of therapy. Implantable drug delivery systems (DDS) have been developed to optimize therapeutic properties of drugs and ensure their slow release in the specific site. Polymeric materials can play an essential role in modulating drug delivery and their use in such field has become indispensable. During last decades, acrylic polymers have obtained growing interest. Biocompatibility and chemical properties make them extremely versatile, allowing their use in many field such as biomedical. In particular, block methacrylate copolymer with a balance of hydrophilic and hydrophobic properties can be suitable for prolonged DDS in biomedical devices. In this work, we focused on the realization of a system for controlled and long term release of betamethasone 17,21-dipropionate (BDP), a cortisone drug, from methacrylic block copolymers, to be tested in the treatment of the posterior eye’s diseases. Different series of methyl methacrylate/hydroxyethyl methacrylate (MMA/HEMA) block and random copolymers, with different monomer compositions (10–60% HEMA), were synthetized by Atom Transfer Radical Polymerization (ATRP) to find the best hydrophilic/hydrophobic ratio, able to ensure optimal kinetic release. Copolymer samples were characterized by NMR spectroscopy ({sup 1}H-NMR, {sup 13}C-NMR, CosY), SEC, TGA and DSC. Monitoring of drug release from films loaded with BDP was carried out by HPLC analysis. Evaluation of different kinetic models allowed to deduce that release of BDP is controlled over time from PMMA-b-PHEMA 53/47. In particular, PMMA-b-PHEMA 53/47 showed the best release profile to achieve the therapeutic reference dose of 3 µg/die, employed in treatment of posterior eye disease, up to four months. Accordingly, PMMA-b-PHEMA 53/47 has been tested to prepare ocular inserts. Ocular inserts with different shape and the same area of polymer films have been obtained using silicon moulds made by a 3D printer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SIMULTANEOUS MULTI-BAND DETECTION OF LOW SURFACE BRIGHTNESS GALAXIES WITH MARKOVIAN MODELING

We present to the astronomical community an algorithm for the detection of low surface brightness (LSB) galaxies in images, called MARSIAA (MARkovian Software for Image Analysis in Astronomy), which is based on multi-scale Markovian modeling. MARSIAA can be applied simultaneously to different bands. It segments an image into a user-defined number of classes, according to their surface brightness and surroundings-typically, one or two classes contain the LSB structures. We have developed an algorithm, called DetectLSB, which allows the efficient identification of LSB galaxies from among the candidate sources selected by MARSIAA. The application of the method to two and three bands simultaneously was tested on simulated images. Based on our tests, we are confident that we can detect LSB galaxies down to a central surface brightness level of only 1.5 times the standard deviation from the mean pixel value in the image background. To assess the robustness of our method, the method was applied to a set of 18 B- and I-band images (covering 1.3 deg{sup 2} in total) of the Virgo Cluster to which Sabatini et al. previously applied a matched-filter dwarf LSB galaxy search algorithm. We have detected all 20 objects from the Sabatini et al. catalog which we could classify by eye as bona fide LSB galaxies. Our method has also detected four additional Virgo Cluster LSB galaxy candidates undetected by Sabatini et al. To further assess the completeness of the results of our method, both MARSIAA, SExtractor, and DetectLSB were applied to search for (1) mock Virgo LSB galaxies inserted into a set of deep Next Generation Virgo Survey (NGVS) gri-band subimages and (2) Virgo LSB galaxies identified by eye in a full set of NGVS square degree gri images. MARSIAA/DetectLSB recovered {approx}20% more mock LSB galaxies and {approx}40% more LSB galaxies identified by eye than SExtractor/DetectLSB. With a 90% fraction of false positives from an entirely unsupervised pipeline, a completeness of 90% is reached for sources with r{sub e} > 3'' at a mean surface brightness level of {mu}{sub g} = 27.7 mag arcsec{sup -2} and a central surface brightness of {mu}{sup 0}{sub g} = 26.7 mag arcsec{sup -2}. About 10% of the false positives are artifacts, the rest being background galaxies. We have found our proposed Markovian LSB galaxy detection method to be complementary to the application of matched filters and an optimized use of SExtractor, and to have the following advantages: it is scale free, can be applied simultaneously to several bands, and is well adapted for crowded regions on the sky.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring the potential of context-sensitive CADe in screening mammography

Purpose: Conventional computer-assisted detection (CADe) systems in screening mammography provide the same decision support to all users. The aim of this study was to investigate the potential of a context-sensitive CADe system which provides decision support guided by each user's focus of attention during visual search and reporting patterns for a specific case. Methods: An observer study for the detection of malignant masses in screening mammograms was conducted in which six radiologists evaluated 20 mammograms while wearing an eye-tracking device. Eye-position data and diagnostic decisions were collected for each radiologist and case they reviewed. These cases were subsequently analyzed with an in-house knowledge-based CADe system using two different modes: Conventional mode with a globally fixed decision threshold and context-sensitive mode with a location-variable decision threshold based on the radiologists' eye dwelling data and reporting information. Results: The CADe system operating in conventional mode had 85.7% per-image malignant mass sensitivity at 3.15 false positives per image (FPsI). The same system operating in context-sensitive mode provided personalized decision support at 85.7%-100% sensitivity and 0.35-0.40 FPsI to all six radiologists. Furthermore, context-sensitive CADe system could improve the radiologists' sensitivity and reduce their performance gap more effectively than conventional CADe. Conclusions: Context-sensitive CADe support shows promise in delineating and reducing the radiologists' perceptual and cognitive errors in the diagnostic interpretation of screening mammograms more effectively than conventional CADe.

60 APPLIED LIFE SCIENCES↗

WE-D-204-02: Novel Method for Correcting Degradation of Sharpness of Liquid-Crystal Display Based On Modulation Transfer Function

Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters were computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gut Microbial Alterations Associated With Protection From Autoimmune Uveitis

The bacteria that live normally in our intestinal tract, or the gut microbiota contribute to the pathogenesis of extra intestinal autoimmune disease via their ability to dynamically educate the immune system. For example, in a mouse model of relapsing, remitting multiple sclerosis (MS), experimental autoimmune encephalomyelitis or EAE, several studies demonstrated that commensal microorganisms are essential in causing clinical disease activity. Interestingly, MS patients have a distinct gut microbiota to healthy controls. Several studies have also illustrated the importance of the gut microbiome in the development of other diseases, including Type 1 diabetes, metabolic syndrome, rheumatoid arthritis, and ankylosing spondylitis. Furthermore, HLA=B27 transgenic rats, which develop spontaneous spondyloarthropathy analogous to patients who have ankylosing spondylitis, associated with uveitis in humans, do not develop intestinal or peripheral join inflammation when raised in a germ-free environment. Our group has shown that HLA-B27 transgenic rats have an altered intestinal microbiota compared to healthy control rats. Given the similarities between the central nervous system (CNS) and the retina, as well as co-expression of potentially immunogenic self-antigens from the CNS and joint in the eye, we hypothesized that modulating the gut microbiome can result in amelioration of autoimmune uveitis. Although uveitis is a heterogeneous collection of diseases, in general immune-mediated, non-infectious, uveitis is thought to be due to a combination of genetic and environmental factors. It arises from an imbalance between the regulatory and effector arms of the immune system, result in an inappropriate immune reaction at an otherwise immune-privileged tissue site, the eye. Th1 and Th17 T lymphocytes are examples of effector immune cell subsets that my contribute to inflammatory disease of the eye, whereas regulatory T cells (Tregs) are an example of a regulatory immune cell subset that is typically required to downregulate an immune response to prevent uncontrolled disease. Experimental autoimmune uveitis (EAU) is a very robust, widely use model of T lymphoocyte mediated uveitis that can be induced in a certain strains of mice (e.g. B10.RIII) by immunizing these animals with a specific retinal antigen, interphotoreceptor binding protein (IRBP), but requires co-administration of an adjuvant containing killed Mycobacterium antigen. Lastly, this model of inducible uveitis is analogous to the EAE model of demyelinating disease mentioned above. EAU is a thought to be predominantly Th1 and Th17 mediated.

60 APPLIED LIFE SCIENCES↗

Selective Equatorial Sclera Crosslinking in the Orbit Using a Metal-Coated Polymer Waveguide

Purpose: Photochemical crosslinking of the sclera is an emerging technique that may prevent excessive eye elongation in pathologic myopia by stiffening the scleral tissue. To overcome the challenge of uniform light delivery in an anatomically restricted space, we previously introduced the use of flexible polymer waveguides. We presently demonstrate advanced waveguides that are optimized to deliver light selectively to equatorial sclera in the intact orbit. Methods: Our waveguides consist of a polydimethylsiloxane cladding and a polyurethane core, coupled to an optical fiber. A reflective silver coating deposited on the top and side surfaces of the waveguide prevents light leakage to nontarget, periorbital tissue. Postmortem rabbits were used to test the feasibility of in situ equatorial sclera crosslinking. Tensometry measurements were performed on ex vivo rabbit eyes to confirm a biomechanical stiffening effect. Results: Metal-coated waveguides enabled efficient light delivery to the entire circumference of the equatorial sclera with minimal light leakage to the periorbital tissues. Blue light was delivered to the intact orbit with a coefficient of variation in intensity of 22%, resulting in a 45 ± 11% bleaching of riboflavin fluorescence. A 2-fold increase in the Young's modulus at 5% strain (increase of 92% P < 0.05, at 25 J/cm 2 ) was achieved for ex vivo crosslinked eyes. Conclusions: Flexible polymer waveguides with reflective, biocompatible surfaces are useful for sclera crosslinking to achieve targeted light delivery. We anticipate that our demonstrated procedure will be applicable to sclera crosslinking in live animal models and, potentially, humans in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging

Two-photon excitation fluorescence (2PEF) allows imaging of tissue up to about one millimeter in thickness. Typically, reducing fluorescence excitation exposure reduces the quality of the image. However, using deep learning super resolution techniques, these low-resolution images can be converted to high-resolution images. This work explores improving human tissue imaging by applying deep learning to maximize image quality while reducing fluorescence excitation exposure. We analyze two methods: a method based on U-Net, and a patch-based regression method. Both methods are evaluated on a skin dataset and an eye dataset. The eye dataset includes 1200 paired high power and low power images of retinal organoids. The skin dataset contains multiple frames of each sample of human skin. High-resolution images were formed by averaging 70 frames for each sample and low-resolution images were formed by averaging the first 7 and 15 frames for each sample. The skin dataset includes 550 images for each of the resolution levels. We track two measures of performance for the two methods: mean squared error (MSE) and structural similarity index measure (SSIM). For the eye dataset, the patches method achieves an average MSE of 27,611 compared to 146,855 for the U-Net method, and an average SSIM of 0.636 compared to 0.607 for the U-Net method. For the skin dataset, the patches method achieves an average MSE of 3.768 compared to 4.032 for the U-Net method, and an average SSIM of 0.824 compared to 0.783 for the U-Net method. Despite better performance on image quality, the patches method is worse than the U-Net method when comparing the speed of prediction, taking 303 seconds to predict one image compared to less than one second for the U-Net method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The comparison between effects of Taichi and conventional exercise on functional mobility and balance in healthy older adults: a systematic literature review and meta-analysis

Background Taichi is beneficial for functional mobility and balance in older adults. However, such benefits of Taichi when comparing to conventional exercise (CE) are not well understood due to large variance in study protocols and observations. Methods We reviewed publications in five databases. Eligible studies that examined the effects of Taichi on the outcomes of functional mobility and balance in healthy older adults as compared to CE were included. Subgroup analyses compared the effects of different types of CE (e.g., single and multiple-type exercise) and different intervention designs (e.g., Taichi types) on those outcomes (Registration number: CRD42022331956). Results Twelve studies consisting of 2,901 participants were included. Generally, compared to CE, Taichi induced greater improvements in the performance of Timed-Up-and-Go (SMD = −0.18, [−0.33 to −0.03], p = 0.040, I 2 = 59.57%), 50-foot walking (MD = −1.84 s, [−2.62 to −1.07], p < 0.001, I 2 = 0%), one-leg stance with eyes open (MD = 6.00s, [2.97 to 9.02], p < 0.001, I 2 = 83.19%), one-leg stance with eyes closed (MD = 1.65 s, [1.35 to 1.96], p < 0.001, I 2 = 36.2%), and functional reach (SMD = 0.7, [0.32 to 1.08], p < 0.001, I 2 = 86.79%) tests. Subgroup analyses revealed that Taichi with relatively short duration (<20 weeks), low total time (≤24 h), and/or using Yang-style, can induce significantly greater benefits for functional mobility and balance as compared to CE. Uniquely, Taichi only induced significantly greater improvements in Timed-Up-and-Go compared to single- (SMD = −0.40, [−0.55 to −0.24], p < 0.001, I 2 = 6.14%), but not multiple-type exercise. A significant difference between the effects of Taichi was observed on the performance of one-leg stance with eyes open when compared to CE without balance (MD = 3.63 s, [1.02 to 6.24], p = 0.006, I 2 = 74.93%) and CE with balance (MD = 13.90s, [10.32 to 17.48], p < 0.001, I 2 = 6.1%). No other significant difference was shown between the influences of different CE types on the observations. Conclusion Taichi can induce greater improvement in functional mobility and balance in older adults compared to CE in a more efficient fashion, especially compared to single-type CE. Future studies with more rigorous design are needed to confirm the observations here.

Li, Yiting↗

Ocular counterrolling measured during eight hours of sustained body tilt

Adaptation of otolith organ activity was investigated by monitoring the ocular counterrolling response of four normal individuals and three persons with severe bilateral loss of labyrinthine function. Several eye photographs were recorded every 30 minutes during a period of 8 hours in which the subject was held in a lateral tilt (60 deg) position. The recorded eye roll position varied to an expected small extent within each test session; this variation about a given mean roll position was similar among the test sessions for all subjects. The mean roll position, on the other hand, changed from session to session in substantial amounts, but these changes appeared to be random with respect to time and among subjects. Furthermore, the intersessional variation in the mean torsional eye position of the normal subjects was equivalent to that of the labyrinthine-defective subjects who displayed little or no counterrolling. These results suggest that the human counterrolling response is maintained either by essentially nonadapting macular receptors or by extremely fine movements of the head in the gravitational field, such as may have been allowed by the biteboard/headrest restraint system used in this study, which served as an everchanging accelerative stimulus.

Miller, E. F., II↗

Effect of gravitoinertial force on ocular counterrolling.

The effect of G loading on the magnitude of ocular counterrolling at various angles of tilt up to 63 deg. was measured on normal subjects and compared with the effect on persons with severe or complete loss of vestibular function. The group of six normal subjects manifested a compensatory eye roll which increased as a direct and essentially linear function of the component of the gravitoinertial force acting laterally on the subject. This increase in response was not observed in the five deaf subjects with severe or complete bilateral loss of their vestibular organs. These findings confirmed similar results found by other authors using other measuring techniques which show that the reflex eye movement is dependent on and limited to the magnitude of the gravitoinertial stimulus (within the range used) when the otolithocular system is functioning normally. However when this function is severely impaired or lost, the magnitude of the compensatory eye roll is limited to that manifested at 1 G and possibly to nonotolithic contributions. These findings offer means for differentiation between otolithic-defective and ?normal' persons who exhibit little counterrolling.

Miller, E. F., II↗

Exploration of Marine Resources by Photographic Remote Sensing

The interpretation of photographs in oceanographic remote sensing is discussed. The photographs were made from spacecraft with two exceptions. Two photographs were made from aircraft. There were three types of film used to make the photographs: black-and-white, color, and color IR. Black and white photography is well known; it presents pictures in various shades of gray from black to white. Color film presents pictures in color, very nearly as the human eye sees them. Color IR film presents pictures in color also but not as seen by the human eye. Blue becomes much deeper blue, green is suppressed to some extent, and red is recorded beyond the visual range of the human eye, out in the near infrared. The most noticeable effect of the use of color IR film is that leaf materials which are highly reflective in the infrared part of the spectrum are presented as red.

Duntley, S. Q.↗

Ophthalmic method and apparatus

A method and apparatus for removing material and components such as the lens from an eye is described. High speed rotary cutting members at one end of a rod macerate the lens while an annular tubing disposed around the cutting members vibrates ultrasonically to coact with the cutting members in macerating the lens. At the same time, a liquid is supplied to the chamber behind the cornea of the eye. Spiral grooves extending along the rotating rod from the cutting members evacuate the liquid and the macerated material from the eye. An alternate embodiment of the apparatus includes a tube through which liquid is supplied to the operative site of the ultrasonically vibrating tube and the cutting members in the area of the lens.

Evvard, J. C.↗

Automated nystagmus analysis

Several methods have recently been used for on-line analysis of nystagmus: A digital computer program has been developed to accept sampled records of eye position, detect fast phase components, and output cumulative slow phase position, continuous slow phase velocity, instantaneous fast phase frequency, and other parameters. The slow phase velocity is obtained by differentiation of the calculated cumulative position rather than the original eye movement record. Also, a prototype analog device has been devised which calculates the velocity of the slow phase component during caloric testing. Examples of clinical and research eye movement records analyzed with these devices are shown.

Oman, C. M.↗