Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

(Poster) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Poster submission. This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation, electromagnetic fields and vibration in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Characterization and Evaluation of Scintillating Fiber System Components

Idaho National Laboratory is studying long scintillation fibers (SF) in a project called “TRIPWIRE” which aims to verify containment in inaccessible nuclear waste repositories. This system will continuously monitor ionizing radiation, electromagnetic fields, and seismic activity in the vicinity of nuclear waste. Previous experiments have determined a better alternative to long SF is to couple shorter SF to kilometer scale optical fiber (OF) to reach electronics far outside of the repository. Minor signal attenuation from coupling these fibers has been observed using optical spectrometry. This experiment characterized two photomultiplier tubes (PMT) to reduce this loss by matching their spectral response characteristics to the SF’s emission spectrum. The experiment created a comparison between the two PMTs showing results that suggest other characteristics are playing a major role in improving signal attenuation when the SF is coupled to OF.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Generation of nonthermal continuum radiation in the magnetosphere

Generation of electromagnetic continuum radiation from electrostatic fluctuations near the upper hybrid resonance frequency has been calculated by using cold plasma theory in an inhomogeneous plasma near the plasmapause. It is shown that both the polarization and the amplitude of electromagnetic radiation are in good quantitative agreement with spacecraft observations for nonthermal continuum radiation.

Okuda, H.↗

Solution of electromagnetic scattering and radiation problems using a spectral domain approach - A review

This paper presents a brief review of some recent developments on the use of the spectral-domain approach for deriving high-frequency solutions to electromagnetics scattering and radiation problems. The spectral approach is not only useful for interpreting the well-known Keller formulas based on the geometrical theory of diffraction (GTD), it can also be employed for verifying the accuracy of GTD and other asymptotic solutions and systematically improving the results when such improvements are needed. The problem of plane wave diffraction by a finite screen or a strip is presented as an example of the application of the spectral-domain approach.

Mittra, R.↗

Aperiodic graphene ribbons in MOSFET topology for multi-wavelength terahertz generation

This paper proposes and simulates multi-wavelength terahertz wave generation using MOSFET with aperiodic gate structure. This emitter works at room temperature and spans the whole terahertz spectra. Structure of the emitter is like a MOSFET for which the channel and gate respectively consist of periodic and aperiodic graphene ribbons. By applying a DC voltage to the source and drain contacts, a DC current flows through the periodic channel. Then by applying a gate voltage to aperiodic graphene ribbons, the current is modulated with aperiodic graphene potential of the gate. The gate voltage applies aperiodic potential U(x) to channel’s electrons that subsequently modulates current of the periodic channel. The modulated current radiates coherent electromagnetic waves. By tuning parameters of the emitter, the radiated coherent electromagnetic wave is in THz range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Soft-photon emission effects and radiative corrections for electromagnetic processes at very high energies

Higher-order electromagnetic processes involving particles at ultrahigh energies are discussed, with particular attention given to Compton scattering with the emission of an additional photon (double Compton scattering). Double Compton scattering may have significance in the interaction of a high-energy electron with the cosmic blackbody photon gas. At high energies the cross section for double Compton scattering is large, though this effect is largely canceled by the effects of radiative corrections to ordinary Compton scattering. A similar cancellation takes place for radiative pair production and the associated radiative corrections to the radiationless process. This cancellation is related to the well-known cancellation of the infrared divergence in electrodynamics.

Gould, R. J.↗

Coupled radiation transport and plasma physics for ICF simulations [Slides]

Describing high-temperature plasmas requires inclusion of several nonlinear coupled physics, including ion kinetics - for each isotope species present in the plasma, electron kinetics, thermal radiative transfer (TRT), electromagnetic description, and nuclear reactions (fusion burn). Simulating plasmas in ICF hohlraums aims to solve kinetic ions (particles), fluid electrons, energetic electrons, electromagnetics, kinetic radiation (MG DP solver), and laser-plasma interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic scattering and radiation from microstrip patch antennas and spirals residing in a cavity

A new hybrid method is presented for the analysis of the scattering and radiation by conformal antennas and arrays comprised of circular or rectangular elements. In addition, calculations for cavity-backed spiral antennas are given. The method employs a finite element formulation within the cavity and the boundary integral (exact boundary condition) for terminating the mesh. By virtue of the finite element discretization, the method has no restrictions on the geometry and composition of the cavity or its termination. Furthermore, because of the convolutional nature of the boundary integral and the inherent sparseness of the finite element matrix, the storage requirement is kept very low at O(n). These unique features of the method have already been exploited in other scattering applications and have permitted the analysis of large-size structures with remarkable efficiency. In this report, we describe the method's formulation and implementation for circular and rectangular patch antennas in different superstrate and substrate configurations which may also include the presence of lumped loads and resistive sheets/cards. Also, various modelling approaches are investigated and implemented for characterizing a variety of feed structures to permit the computation of the input impedance and radiation pattern. Many computational examples for rectangular and circular patch configurations are presented which demonstrate the method's versatility, modeling capability and accuracy.

Volakis, J. L.↗

An Exploration of Radiation Physics in Electromagnetics

Contents include the following: NASA's Missions and Aeronautics Research. Today's Air Traffic Control System. Development of Decision-Support Tools. The Center-TRACON Automation System (CTAS). The Traffic Management Advisor (TMA). The Multi-Center Traffic Management Advisor (McTMA). The Surface Management System (SMS). Future Directions: The Joint Planning and Development Office.

Lee, Katherine K.↗

A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter

Purpose: To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter.Methods: This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3 × 6 cm{sup 2} radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study.Results: The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053 ± 0.036, 0.121 ± 0.023, and 0.093 ± 0.013 cm.Conclusions: The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Properties of an ultrarelativistic charged particle radiation in a constant homogeneous crossed electromagnetic field

The properties of radiation created by a classical ultrarelativistic scalar charged particle in a constant homogeneous crossed electromagnetic field are described both analytically and numerically with radiation reaction taken into account in the form of the Landau–Lifshitz equation. The total radiation naturally falls into two parts: the radiation formed at the entrance point of a particle into the crossed field (the synchrotron entrance radiation), and the radiation coming from the late-time asymptotics of a particle motion (the de-excited radiation). The synchrotron entrance radiation resembles, although does not coincide with, the ultrarelativistic limit of the synchrotron radiation: its distribution over energies and angles possesses almost the same properties. The de-excited radiation is soft, not concentrated in the plane of motion of a charged particle, and almost completely circularly polarized. The photon energy delivering the maximum to its spectral angular distribution decreases with increasing the initial energy of a charged particle, while the maximum value of this distribution remains the same at the fixed photon observation angle and entrance angle of a charged particle. The ultraviolet and infrared asymptotics of the total radiation are also described. - Highlights: • Properties of an electron radiation in a crossed electromagnetic field are studied. • Spectral angular distribution of the synchrotron entrance radiation is described. • Spectral angular distribution of the de-excited radiation is described. • De-excited radiation is almost completely circularly polarized. • Photon energy at the maximum of the de-excited radiation decreases with increasing the initial energy of an electron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimating a Large Phased Array Antenna Radiation Pattern by Computer Electromagnetic Simulation

The design of a conformal antenna for use on UAV's (Unmanned Aerial Vehicle) and other aircraft can be enhanced with computational electromagnetic modeling to determine the expected radiation patterns of the antenna when mounted on the aircraft. However, detailed simulation of the antenna structure and the aircraft together requires significant computational resources and time which may not be available. This paper details several methods for estimating the radiation pattern of a 50 by 50-element patch antenna. The Conformal Lightweight Antenna Structures for Aeronautical Communication Technologies (CLASACT) Program aims to build and test a 14.25 gigaherz (Ku-band) conformal antenna on a NASA-owned UAV. The antenna is intended for satellite communications and will enable communication between a ground station and a UAV when the separation distance is too great for line-of-sight communication. It is estimated that a 2 degree beamwidth will be necessary, requiring a 50 by 50 array of patch elements. The narrow beamwidth requirement, together with an element spacing of 0.6 lambda means that the array length will be 30 wavelengths, electrically very large. Three methods of varying complexity are described for estimating the total far-field radiation pattern. The results are shown for each method in the form of a normalized power pattern.

Mackenzie, Anne I.↗