Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Reliability study of opto-coupled semiconductor devices and Light Emitting Diodes (LED)

Opto-coupler and light emitting diode (LED) failure mechanisms and associated activation energies were determind from the results of environmental and accelerated lift tests of over 2,400 devices. The evaluation program included LED phototransistor opto-couplers from three sources, LED photoamplifier opto-couplers from a single source, and discrete infrared emitting LEDs from two sources. Environmental tests to evaluate device mechanical integrity included power cycling (10,000 cycles), temperature cycling (500 cycles) and a sequence of monitored shock, monitored vibration and constant acceleration. Multiple temperature operating life tests were conducted at ambient temperatures between 25 C and 200 C. Opto-couplers were operated in both the 'on' and 'off' states during life testing.

Maurer, R. C.↗

Development of design, qualification, screening, and application requirements for plastic encapsulated solid-state devices for space applications

Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.

Source record↗

Air removal device

The disclosure concerns a device suitable for removing air from water under both zero and one 'g' gravity conditions. The device is comprised of a pair of spaced membranes on being hydrophobic and the other being hydrophilic. The air-water mixture is introduced into the space therebetween, and the selective action of the membranes yields removal of the air from the water.

Booth, F. W.↗

Cervix-to-rectum measuring device in a radiation applicator for use in the treatment of cervical cancer

A cervix-to-rectum measuring device to be used in the treatment of cervical cancer is described. It includes a handle and a probe pivotably connected to the handle for insertion in the rectum. The measuring device further includes means for coupling the handle to an intrauterine radiation applicator when the latter is positioned in the uterine cervix and the probe is inserted in the rectum to pivot the handle about the probe. A gear is provided which is adapted to pivot with the probe. A pinion pivotably connected to the handle meshes with the gear. A pointer fixed to the pinion is displaced in response to the pivoting of the handle about the probe, and this displacement can be read from a scale on the handle, providing an indication of the cervix-to-rectum distance.

Fischell, D. R.↗

Texas Instruments /TI/ 800 x 800 charge-coupled device /CCD/ image sensor

Very-large area high-performance CCD image sensors with 800 x 800 pixel format have been successfully fabricated and operated on the basis of a three-level polysilicon gate technology. They are thinned to 8 microns over the entire 12.2 x 12.2 mm active area, and are used in the rear illumination mode. The light transfer characteristic has a gamma value of 1.000 + or - 0.002 over most of the dynamic range. Analysis of the noise behavior shows that the device SNR is shot-noise-limited over most of the dynamic range. Simple on-chip signal processing can be performed using an integration well to noiselessly collect signal charge from multiple pixels prior to reading out the charge. A UV-sensitive phosphor has been applied to the chip, yielding a device capable of imaging at wavelengths from the vacuum UV to the near IR.

Blouke, M. M.↗

Soft X-ray and XUV imaging with a charge-coupled device /CCD/-based detector

A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.

Loter, N. G.↗

The design integration of wingtip devices for light general aviation aircraft

An investigation was conducted to determine the load carrying capabilities and structural design requirements for wingtip devices on general aviation aircraft. Winglets were designed and analyzed as part of a research program involving a typical agricultural aircraft. This effort involved analytical load prediction for the winglets, structural design for both the winglets and aircraft installation, structural load testing and flight test verification. Conclusions from this program are believed to be applicable to the use of wingtip devices on light-weight general aviation aircraft.

Gifford, R. V.↗

Intensified charge coupled devices for use as a spaceborne spectrographic image-plane detector system

An instrument that has been developed for studies of atmospheric emissions from the Space Shuttle comprises an array of imaging spectrometers to observe features over the 300-12,000-A wavelength range. Each spectrometer has a 2-D image-plane detector system on which spectral information is dispersed in one direction and spatial information is resolved in the other. The detectors consist of CCD arrays which are coupled to proximity focused image intensifiers. The intensifier in each case is selected for the wavelength range covered by the particular spectrometer. The result is a compact low-power spectrographic detector system. In the course of building the five flight detector systems, there was occasion to evaluate a larger number of the charge coupled devices and the proximity focused image intensifiers. Various characteristics, advantages, and shortcomings of these devices and the overall intensified CCD system are reported.

Torr, M. R.↗

The development and applications of charge-coupled devices for space astronomy

The developments in charge-coupled device technology over the past decade are reviewed, with emphasis on the relevance of these developments to astronomical applications. The characteristics and limitations of current commercial devices are described, and the future requirements on CCDs for space astronomy are summarized for the X-ray and near UV, optical, and infrared wavelength ranges. Emphasis is placed on the commonality of technological development which is called for, including the issues of quantum detection efficiency (photon entrance and depletion depth), charge transfer efficiency, modulation transfer function, output noise level, and array size. The system requirements on focal plane instrumentation for space astronomy are summarized, and shown to have much in common for the different wavelength bands. These requirements are discussed in terms of CCD mosaicing, cryogenic cooling, and electronics. The overlap in CCD developments in the defense, astronomical and commercial arenas is summarized.

Griffiths, R. E.↗

An advanced tracker design for pointing and control of space vehicles using the charge injection device

The use of charge transfer devices (CTD) in pointing and control of space vehicles is examined, with emphasis on the use of charge injection devices (CID). The selection of CTD type and CID operation, including CID signal and noise analysis and signal improvement, are discussed. Star tracking operational advantages of the CTD are pointed out, and the tracking optical concept is discussed and graphically depicted. The position interpolation procedure and the effects of rate of stellar motion on position interpolation are considered, and error analysis is examined. Finally, the breadboard and test program are discussed in detail, coarse and fine acquisition, test for star, track pattern, test procedure and results. An overall accuracy performance of approximately 0.02 pixels or approximately 0.8 arcsec for the test equipment and tracker was obtained.

Jones, C.↗

The aerodynamic performance of several flow control devices for internal flow systems

An experimental reseach and development program was undertaken to develop and document new flow-control devices for use in the major modifications to the 40 by 80 Foot wind tunnel at Ames Research Center. These devices, which are applicable to other facilities as well, included grid-type and quasi-two-dimensional flow straighteners, louver panels for valving, and turning-vane cascades with net turning angles from 0 deg to 90 deg. The tests were conducted at model scale over a Reynolds number range from 2 x 100,000 to 17 x 100,000, based on chord. The results showed quantitatively the performance benefits of faired, low-blockage, smooth-surface straightener systems, and the advantages of curved turning-vanes with hinge-line gaps sealed and a preferred chord-to-gap ratio between 2.5 and 3.0 for 45 deg or 90 deg turns.

Eckert, W. T.↗

Experimental study of wing leading-edge devices for improved maneuver performance of a supercritical maneuvering fighter configuration

Wind tunnel tests were conducted to examine the use of wing leading-edge devices for improved subsonic and transonic maneuver performance. These devices were tested on a fighter configuration which utilized supercritical-wing technology. The configuration had a leading-edge sweep of 45 deg and an aspect ratio of 3.28. The tests were conducted at Mach numbers of 0.60 and 0.85 with angles of attack from -0.5 deg to 22 deg. At both Mach numbers, sharp leading-edge flaps produced vortices which greatly altered the flow pattern on the wing and resulted in substantial reductions in drag at high lift. Underwing or pylon-type vortex generators also reduced drag at high lift. The vortex generators worked better at a Mach number of 0.60. The vortex generators gave the best overall results with zero toe-in angle and when mounted on either the outboard part of the wing or at both an outboard location and halfway out the semispan. Both the flaps and the vortex generators had a minor effect on the pitching moment. Fluorescent minitufts were found to be useful for flow visualization at transonic maneuver conditions.

Mann, M. J.↗

GaAs microwave devices and circuits with submicron electron-beam defined features

This paper describes the fabrication and application of GaAs FET's, both as discrete microwave devices and as the key active components in monolithic microwave integrated circuits. The performance of these devices and circuits is discussed for frequencies ranging from 3 to 25 GHz. The crucial fabrication step is the formation of the submicron gate by electron-beam lithography.

Wisseman, W. R.↗

Isolation Mounting for Charge-Coupled Devices

CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.

Goss, W. C.↗

Light-Activated Microwave Device

Laser-activated microwave semiconductor device switches at microwave speeds, generates pulses, or detects optical pulses with fast response. Device consists essentially of back-to-back metal/thin oxide/silicon (MTOS) capacitors on silicon chip.

Maserjian, J.↗

Effect of thrust vectoring and wing maneuver devices on transonic aeropropulsive characteristics of a supersonic fighter

The aeropropulsive characteristics of an advanced fighter designed for supersonic cruise were determined in the Langley 16-Foot Transonic Tunnel. The objectives of this investigation were to evaluate the interactive effects of thrust vectoring and wing maneuver devices on lift and drag and to determine trim characteristics. The wing maneuver devices consisted of a drooped leading edge and a trailing-edge flap. Thrust vectoring was accomplished with two dimensional (nonaxisymmetric) convergent-divergent nozzles located below the wing in two single-engine podded nacelles. A canard was utilized for trim. Thrust vector angles of 0 deg, 15 deg, and 30 deg were tested in combination with a drooped wing leading edge and with wing trailing-edge flap deflections up to 30 deg. This investigation was conducted at Mach numbers from 0.60 to 1.20, at angles of attack from 0 deg to 20 deg, and at nozzle pressure ratios from about 1 (jet off) to 10. Reynolds number based on mean aerodynamic chord varied from 9.24 x 10 to the 6th to 10.56 x 10 to the 6th.

Capone, F. J.↗

Annular Momentum Control Device (AMCD)

The Annular Momentum Control Device (AMCD) concept, applications, and advantages as a momentum storage device are discussed. A laboratory test model AMCD was designed and built. The laboratory model AMCD is described and the results of the laboratory model test phase are presented. The efforts required to complete the AMCD laboratory model test phase are outlined.

Groom, N. J.↗

Clamp-mount device

A clamp-mount device is disclosed for mounting equipment to an associated I-beam and the like structural member of the type having oppositely extending flanges wherein the device comprises a base and a pair of oppositely facing clamping members carried diagonally on the base clamping flanges therebetween and having flange receiving openings facing one another. Lock means are carried diagonally by the base opposite the clamping members locking the flanges in the clamping members. A resilient hub is carried centrally of the base engaging and biasing a back side of the flanges maintaining tightly clamped and facilitating use on vertical as well as horizontal members. The base turns about the hub to receive the flanges within the clamping members. Equipment may be secured to the base by any suitable means such as bolts in openings. Slidable gate latches secure the hinged locks in an upright locking position. The resilient hub includes a recess opening formed in the base and a rubber-like pad carried in this opening being depressably and rotatably carried therein.

Clark, K. H.↗