Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods and materials for determination of distribution coefficients for separation materials

Methods and materials for determining the affinity of separation materials for targeted species are described. A composite separation medium is described that combines a separation material such as an ion exchange material or a sorbent with an SERS substrate. Methods and materials can be utilized to determine the distribution coefficient of a species for a separation material after running a single separation protocol followed by examination of the separation material of the protocol according to SERS. Disclosed methods can be utilized to determine the affinity of existing separation materials for targeted species as well as to determine the affinity of newly engineered separation materials to characterize species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The design and safe operation of experiments in ATR is aided by the operation of the ATR-Critical Facility (ATR-C), a lower-power reactor with the same size and geometry of the ATR. Short, low-power irradiations at the ATR-C are used to study the effects of control devices and test assemblies on the overall power distribution of various core loadings and to compare calculated data for reactor models. A technique was developed at INL to measure fission rates in fuel plate assembly reactors utilizing small, enriched uranium-aluminum (U-Al) alloy monitors, and to support ATR-C irradiations for forty years. Several hundred monitor wires placed throughout the reactor provide fine spatial resolution of the fission rates. A direct correlation exists between the fission rates of the U-Al monitors and the immediately adjacent reactor region. Extensive calibration was previously performed to determine the conversion factor for beta-particle activity of the irradiated U-Al monitors. The fission rate in the U-Al monitors can thus be determined by measuring the beta-particle decay of fission-products following irradiation of the monitors. The American Society for Testing and Materials (ASTM International) has established a standard practice for determining neutron fluence rate by radioactivation of depleted uranium. The ASTM standard practice also measures the concentration of fission-products in the uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of the ASTM standard practice was investigated for ATR-C irradiations and compared to the present method. The need to analyze hundreds of samples for each irradiation posed several challenges. Therefore, practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the expected sources of error for each method were investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Baryon Resonance determination from Lattice QCD

There has been a resurgence of interest in spectroscopy with a new generation of experiments worldwide, for example BES III, COMPASS, GSI/Panda, and Jefferson Lab's GlueX project as well as CLAS12. Spectroscopy reveals fundamental aspects of hadronic physics. However, the excited spectrum of light quark mesons and baryons is not well determined nor understood. Lattice QCD is quite amenable to such non-perturbative studies. Recent calculations have determined a version of the highly excited spectrum of baryons with zero and non-zero strangeness. Current efforts are aimed at determining the resonance structure of such states. I will report on these recent calculatuions and outline methods that are used for resonance parameter determination from the lattice.

Edwards, Robert↗

Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study

Purpose: To determine the cut-off standardized uptake value (SUV) on {sup 18}F fluoro-2-deoxy-glucose (FDG) positron emission tomography/computed tomography (FDG-PET/CT) images that generates the best volumetric match to pathologic gross tumor volume (GTV{sub path}) for non-small-cell lung cancer (NSCLC). Methods and Materials: Fifteen patients with NSCLC who underwent FDG-PET/CT scans followed by lobectomy were enrolled. The surgical specimen was dissected into 5-7-mum sections at approximately 4-mm intervals and stained with hematoxylin and eosin. The tumor-containing area was outlined slice by slice and the GTV{sub path} determined by summing over all the slices, taking into account the interslice thickness and fixation-induced volume reduction. The gross tumor volume from the PET images, GTV{sub PET}, was determined as a function of cut-off SUV. The optimal threshold or optimal absolute SUV was defined as the value at which the GTV{sub PET} was the same as the GTV{sub path}. Results: The fixation process induced a volumetric reduction to 82% +- 10% (range, 62-100%) of the original. The maximal SUV was 10.1 +- 3.6 (range, 4.2-18.7). The optimal threshold and absolute SUV were 31% +- 11% and 3.0 +- 1.6, respectively. The optimal threshold was inversely correlated with GTV{sub path} and tumor diameter (p < 0.05), but the optimal absolute SUV had no significant correlation with GTV{sub path} or tumor diameter (p > 0.05). Conclusion: This study evaluated the use of GTV{sub path} as a criterion for determining the optimal cut-off SUV for NSCLC target volume delineation. Confirmatory studies including more cases are being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WIPP PA Sensitivity Studies in Support of CRA-2014 Completeness Determination and Compliance Decision - 18209

The Waste Isolation Pilot Plant (WIPP) has been developed by the U.S. Department of Energy (DOE) for the geologic (deep underground) disposal of transuranic (TRU) waste. Containment of TRU waste at the WIPP is regulated by the U.S. Environmental Protection Agency (EPA). The DOE demonstrates compliance with the containment requirements by means of performance assessment (PA) calculations. WIPP PA calculations estimate the probability and consequence of potential radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. Since TRU waste was first received at the WIPP in 1999, compliance recertification applications (CRAs) have been required by the EPA on five-year cycle. The latest CRA (CRA-2014) was submitted by the DOE to the EPA in 2014. As part of the application, a formal set of PA calculations (CRA-2014 PA) was performed and results were documented in detail. The CRA-2014 PA incorporated several parameter updates based on new data, as well as the implementation of a different model for panel closures, barriers planned for the opening of each waste panel. The results presented as part of the CRA-2014 showed via the required complementary cumulative distribution function (CCDF) release curves that the estimated releases were within compliance limits. As part of their process for reviewing the completeness of the CRA-2014 [1], the EPA formally requested that the DOE perform sensitivity studies based on EPA-requested changes to model parameters. The DOE performed and documented the results of three sensitivity studies described below: CRA14-SEN2 [2], CRA14-SEN3 [3], and CRA14-SEN4 [4]. In each case, the new analysis results were compared to CRA- 2014 PA (CRA14) results to determine the impact of the EPA-requested changes. CRA14-SEN2: the application of EPA-requested modified parameters in the operations and experimental (non-waste) areas of the repository to simulate an accelerated (instantaneous) creep closure, the inclusion of capillary pressure effects on relative permeability, and an increase in initial/residual brine saturation and residual gas saturation. The modifications to the repository model resulted in increased pressures and decreased brine saturations in waste areas and increased pressures and brine saturations in the operations and experimental areas. However, the overall effects on total high-probability mean releases from the repository were entirely insignificant. It was concluded that the modeling assumptions associated with the operations and experimental areas of the repository have an insignificant effect on the prediction of total releases from the repository and/or adequacy of the current (CRA14) model to demonstrate compliance with the regulatory limits. CRA14-SEN3: the application of EPA-requested modified parameters in the panel closure areas and operations and experimental (non-waste) areas of the repository to simulate an accelerated (instantaneous) creep closure, the inclusion of capillary pressure effects on relative permeability, and an increase in initial/residual brine saturation and residual gas saturation. The modifications to the repository model predominantly result in increased pressures and decreased brine saturations in waste areas, increased pressures and brine saturations in the operations and experimental areas, and decreased brine and gas flows across all panel closures. The pressure increases in repository waste regions yielded slightly decreased brine saturations (on average) in those areas. However, the overall effects on total high-probability mean releases from the repository are entirely insignificant. It was concluded that the modeling assumptions made for this sensitivity study which were associated with the panel closures and north end areas of the repository have only a small effect on the prediction of total releases from the repository and/or adequacy of the current (CRA14) model to demonstrate compliance with the regulatory limits. CRA14-SEN4: the application of several changes to the current WIPP PA model (CRA14), including: parameter changes, use of an updated code, and a revised computational grid for the BRAGFLO code. The modifications to the repository model resulted in increased releases in all primary release mechanisms. The impacts of each EPA-requested change to CRA14 were analyzed with respect to each release mechanism in the CRA14-SEN4 study. Overall, total high-probability predicted mean releases from the repository were increased by about 15%. Total low-probability predicted mean releases were increased by about 107%. It was concluded that the EPA-requested changes to the CRA14 result in increases to the predicted total releases from the repository. However, releases calculated in the CRA14-SEN4 analysis remained below regulatory limits, demonstrating continued compliance of the WIPP. In January 2017, the EPA determined that CRA-2014 was complete and then began a technical evaluation of CRA-2014 to determine whether the WIPP continued to comply with the radiation protection standards for disposal. During their evaluation, the EPA utilized the sensitivity study results to inform their ultimate determination in July 2017 that the WIPP continues to comply with regulatory standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining Physical Parameters of Shielded Uranium using Gamma Spectroscopy and the Differential Evolution Adaptive Metropolis (DREAM) Method

Inverse radiation transport is a well-established method for determining unknown parameters within a system that exhibits particle leakage. Two significant challenges of solving inverse transport problems are (1) to determine multiple unknowns without false convergence on local minima and (2) to be able to quantify uncertainty. It was recently demonstrated that the Differential Evolution Adaptive Metropolis (DREAM) method effectively meets both of these challenges. In Bledsoe's 2014 article, the DREAM method was only applied to numerical test cases in which measured data were simulated using MCNP. This paper provides results of research conducted at Oak Ridge National Laboratory (ORNL) in which DREAM was applied to two-dimensional inverse transport problems using real-world measurements. The DREAM method uses a Markov chain Monte Carlo (MCMC) method to obtain a posterior distribution of unknown parameters. In this application, the posterior distribution is determined by using a uniform prior distribution and a likelihood function. The goal of the inverse problem is to find the regions in which the likelihood function is at or near its maximum. In the traditional MCMC approach, a single Markov chain is employed. In practice, MCMC approaches have a high acceptance rate to solutions that are near the current point of sampling, but they exhibit slow convergence to solutions far from the sampling point. The DREAM algorithm was designed to alleviate this issue by initiating multiple Markov chains and using the differential evolution algorithm to generate trial points for each chain. Solving for the mass of radioactive material within a voluminous source is a challenging problem for gamma-ray spectroscopy. Inverse gamma-ray transport can supply a range of possible material compositions, but reducing the differences between predicted and actual measurements can lead to false results. DREAM is a rapid technique for determining the most likely solution for several unknown parameters in an inverse transport problem. This work applies DREAM to a series of gamma spectroscopy experiments performed at ORNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure Determination of the 1918 H1N1 Neuraminidase From a Crystal With Lattice-Translocation Defects

Few examples of macromolecular crystals containing lattice-translocation defects have been published in the literature. Lattice translocation and twinning are believed to be two common but different crystal-growth anomalies. While the successful use of twinned data for structure determination has become relatively routine in recent years, structure determination of crystals with lattice-translocation defects has not often been reported. To date, only four protein crystal structures containing such a crystal defect have been determined, using corrected, but not uncorrected, intensity data. In this report, the crystallization, structure determination and refinement of N1 neuraminidase derived from the 1918 H1N1 influenza virus (18NA) at 1.65 {angstrom} resolution are described. The crystal was indexed in space group C222{sub 1}, with unit-cell parameters a = 117.7, b = 138.5, c = 117.9 {angstrom}, and the structure was solved by molecular replacement. The lattice-translocation vector in the 18NA crystal was (0, 1/2, 1/2) or its equivalent vector (1/2, 0, 1/2) owing to the C lattice symmetry. Owing to this special lattice-translocation vector in space group C222{sub 1}, structure refinement could be achieved in two different ways: using corrected or uncorrected diffraction data. In the refinement with uncorrected data, a composite model was built to represent the molecules in the translated and untranslated layers, respectively. This composite structure model provided a unique example to examine how the molecules were arranged in the two lattice domains resulting from lattice-translocation defects.

36 MATERIALS SCIENCE↗

A radioactive tracer dilution method to determine the mass of molten salt

A new technique for molten salt mass determination, termed radioactive tracer dilution, that uses 22Na as a tracer was validated. It has been a challenging problem to determine the mass of molten salt in irregularly shaped containers, where a highly radioactive, high-temperature molten salt was used to process nuclear spent/used fuel during electrochemical recycling (pyro-processing) or for coolant/fuel salt from molten salt reactors. A radioactive source with known activity is dissolved into the salt. After a complete mixture, a small amount of the salt is sampled and measured in terms of its mass and radioactivity. By finding the ratio of the mass to radioactivity, the unknown salt mass in the original container can be precisely determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Salt mass determination by 22 Na-based radioactive tracer dilution of a highly radioactive molten salt system for pyroprocessing spent oxide nuclear fuels

To demonstrate the feasibility of the 22 Na-based radioactive tracer dilution (RTD) for determining the total salt mass in a 60-kg oxide reduction (OR) system at Idaho National Laboratory (INL) for pyroprocessing spent oxide nuclear fuels, a LiCl- 22 NaCl tracer salt was prepared and spiked to the OR vessel, and salt samples were analyzed by gamma spectroscopy. Due to the high radioactivity (around 10 mCi/g) of the OR salt, mainly from 137 Cs, traditional gamma spectroscopy methods, which typically involve diluted salt samples, was not effective for analyzing the RTD samples. Since the 22 Na tracer radioactivity was very low, undiluted samples were necessary to detect the small amount of 22 Na tracer. Here, despite the high gamma radioactivity of the OR salt, increasing the detector-sample distance from 20 cm to 40 cm during gamma spectroscopy allowed the detection of radioactivity as low as 0.12 µCi/g 22 Na. The preparation of the 22 NaCl-LiCl tracer salt suitable for spiking into the OR salt was successful, and the mass determined by RTD was consistent with that estimated by salt level measurement. Therefore, the 22 Na-based RTD technique for total mass determination of the 60-kg molten salt system for OR is feasible, though more development work, particularly in the improving the uncertainty, is needed .

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INTERFACES. A Program for Determining the 3D Structures of Surfaces Sites Using NMR Data

Dynamic nuclear polarization surface enhanced NMR spectroscopy has enabled the determination of high-resolution structures from surface-supported molecules, including singlesite heterogeneous catalysts. Structure determinations have largely mimicked the approaches used in biomolecular NMR spectroscopy, namely, using distance measurements to constrain a conformational search. These early demonstrations made use of purpose-built software, which has limited the adoption of the technique. Herein, we describe the open-source program INTERFACES (Interpret NMR to Elucidate or Reconstruct the Full Atomistic Configurations of External Surfaces) which automates the analysis of RE(SP)DOR data as well as the structure determination for surface sites. Distances, angles, dihedral angles, complex orientation, and distance from the support can all be sampled to find all structures that agree with the experimental data. A χ 2 metric is used to define the error ranges of the REDOR fits and produce structures with an arbitrary level of confidence. Structural solutions are then provided as both overlays and ORTEP-like probability ellipsoids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-Dimensional Orientation Determination of Stationary Anisotropic Nanoparticles with Sub-Degree Precision under Total Internal Reflection Scattering Microscopy

Single-particle and single-molecule orientation determination plays a vital role in deciphering nanoscale motion in complex environments. Previous attempts to determine the absolute three-dimensional orientation of anisotropic particles rely on subjective pattern matching and are inherently plagued by high degrees of uncertainty. Herein, we describe a method utilizing total internal reflection scattering microscopy to determine the 3D orientation of gold nanorods with subdegree uncertainty. The method is then applied to the biologically relevant system of microtubule cargo loading. Finally, we demonstrate the method holds potential for identifying single particles versus proximate neighbors within the diffraction limited area.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atomic structures determined from digitally defined nanocrystalline regions

Nanocrystallography has transformed our ability to interrogate the atomic structures of proteins, peptides, organic molecules and materials. By probing atomic level details in ordered sub-10 nm regions of nanocrystals, scanning nanobeam electron diffraction extends the reach of nanocrystallography and in principle obviates the need for diffraction from large portions of one or more crystals. Scanning nanobeam electron diffraction is now applied to determine atomic structures from digitally defined regions of beam-sensitive peptide nanocrystals. Using a direct electron detector, thousands of sparse diffraction patterns over multiple orientations of a given crystal are recorded. Each pattern is assigned to a specific location on a single nanocrystal with axial, lateral and angular coordinates. This approach yields a collection of patterns that represent a tilt series across an angular wedge of reciprocal space: a scanning nanobeam diffraction tomogram. Using this diffraction tomogram, intensities can be digitally extracted from any desired region of a scan in real or diffraction space, exclusive of all other scanned points. Intensities from multiple regions of a crystal or from multiple crystals can be merged to increase data completeness and mitigate missing wedges. It is demonstrated that merged intensities from digitally defined regions of two crystals of a segment from the OsPYL/RCAR5 protein produce fragment-based ab initio solutions that can be refined to atomic resolution, analogous to structures determined by selected-area electron diffraction. In allowing atomic structures to now be determined from digitally outlined regions of a nanocrystal, scanning nanobeam diffraction tomography breaks new ground in nanocrystallography.

36 MATERIALS SCIENCE↗

True molecular conformation and structure determination by three-dimensional electron diffraction of PAH by-products potentially useful for electronic applications

The true mol­ecular conformation and the crystal structure of benzo[e]di­naphtho­[2,3-a;1',2',3',4'-ghi]fluoranthene, 7,14-di­phenyl­naphtho­[1,2,3,4-cde]bis­anthene and 7,16-di­phenyl­naphtho­[1,2,3,4-cde]heli­anthrene were determined ab initio by 3D electron diffraction. All three mol­ecules are remarkable polycyclic aromatic hydro­carbons. The mol­ecular conformation of two of these com­pounds could not be determined via classical spectroscopic methods due to the large size of the mol­ecule and the occurrence of multiple and reciprocally connected aromatic rings. The mol­ecular structure of the third mol­ecule was previously considered provisional. These com­pounds were isolated as by-products in the synthesis of similar products and were at the same time nanocrystalline and available only in very limited amounts. 3D electron diffraction data, taken from submicrometric single crystals, allowed for direct ab initio structure solution and the unbiased determination of the inter­nal mol­ecular conformation. Detailed synthetic routes and spectroscopic analyses are also discussed. Based on many-body perturbation theory simulations, benzo[e]di­naphtho­[2,3-a;1',2',3',4'-ghi]fluoranthene may be a promising candidate for triplet–triplet annihilation and 7,14-di­phenyl­naphtho­[1,2,3,4-cde]bis­anthene may be a promising candidate for inter­molecular singlet fission in the solid state.

36 MATERIALS SCIENCE↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Mars Exploration Rovers orbit determination filter strategy

The successful delivery of the Mars Exploration Rover (MER) landers to well with in the boundaries of their surface target areas in January of 2004 was the culmination of years of orbit determination analysis. The process began with a careful consideration of the filter parameters used for pre-launch covariance studies, and continued with the refinement of the filter after launch based on operational experience. At the same time, tools were developed to run a plethora of variations around the nominal filter and anlyze the results in ways that had never been previously attempted for an interplanetary mission. In addition to the achieved sub-kilometer Mars B plane orbit determination knowledge, the filter strategy and process responded to unexpected error sources by both detecting them and proving robust. All these facets of the MER orbit determination filter strategy are described in this paper.

orbit determination↗

Mars Exploration Rovers orbit determination filter strategy

The successful delivery of the Mars Exploration Rover (MER) landers to well within the boundaries of their surface target areas in January of 2004 was the culmination of years of orbit determination analysis. The process began with a careful consideration of the filter parameters used for pre-launch covariance studies, and continued with the refinement of the filter after launch based on operational experience. At the same time, tools were developed to run a plethora of variations around the nominal filter and analyze the results in ways that had never been previously attempted for an interplanetary mission. In addition to achieving sub-kilometer Mars-relative orbit determination knowledge, the filter strategy and process detected unexpected error sources, while at the same time proving robust by indicating thecorrect solution. Consequently, MER orbit determination set a new standard for interplanetary navigation.

Mars Exploration Rover (MER)↗