Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

RCUT: A Non-Invasive Method for Detection, Location, and Quantification of Radiological Contaminants in Pipes and Ducts - 12514

Radiological Characterization Using Tracers (RCUT) is a minimally invasive method for detection and location of residual radiological contamination in pipes and ducts. The RCUT technology utilizes reactive gaseous tracers that dissociate when exposed to gamma and/or beta radiation emitting from a radiological contaminant in a pipe or duct. Sulfur hexafluoride (SF{sub 6}) was selected as a tracer for this radiological application, because it is a chemically inert gas that is both nonflammable, nontoxic, and breaks down when exposed to gamma radiation. Laboratory tests demonstrated that the tracer pair of SF{sub 6} and O{sub 2} formed SO{sub 2}F{sub 2} when exposed to a gamma or beta radioactive field, which indicated the presence of radiological contamination. Field application of RCUT involves first injecting the reactive tracers into the pipe to fill the pipe being inspected and allowing sufficient time for the tracer to interact with any contaminants present. This is followed by the injection of an inert gas at one end of the pipe to push the reactive tracer at a known or constant flow velocity along the pipe and then out the exit and sampling port at the end of the pipeline where its concentration is measured by a gas chromatograph. If a radiological contaminant is present in the pipe being tested, the presence of SO{sub 2}F{sub 2} will be detected. The time of arrival of the SO{sub 2}F{sub 2} can be used to locate the contaminant. If the pipe is free of radiological contamination, no SO{sub 2}F{sub 2} will be detected. RCUT and PCUT are both effective technologies that can be used to detect contamination within pipelines without the need for mechanical or human inspection. These methods can be used to detect, locate, and/or estimate the volume of a variety of radioactive materials and hazardous chemicals such as chlorinated solvents, petroleum products, and heavy metals. While further optimization is needed for RCUT, the key first step of identification of a tracer compound appropriate for the application of detecting radioactive pipeline contamination through the detection of decomposition products of SF{sub 6} has been demonstrated. Other tracer gases that will also undergo radiolysis will be considered in the future. The next step for the RCUT development process is conducting laboratory scale tests using short pipelines to define analytical requirements, establish performance boundaries, and develop strategies for lower exposure levels. Studies to identify additional analytical techniques using equipment that is more field rugged than a GC/MS would also be beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating Crack Detection and Pipe Shape Optimization for Enhanced Sewage System Durability

Crack detection in underground reinforced concrete pipes has been essential in determining the state of stormwater infrastructure. Detection models have been implemented for detecting cracks and other defects in pipes using CCTV footage for stormwater drainage systems. In addition, Finite element models have been used to determine optimum shapes and pipe thickness for different boundary conditions such as header pipes in power plants. The concept of shape optimization emerges as a crucial factor in power plant design and operation, with the potential to maximize performance while minimizing the use of materials. Shape optimization not only enhances efficiency but also contributes to reducing the environmental footprint. This paper discusses the integration of both topics by using the cracks detected in underground pipes as boundary conditions for shape optimization of the pipes. A machine learning model has been developed which uses limited data for training and outlines the location of detected cracks. A shape optimization methodology is proposed in which ANSYS modules are used to analyze fluid flow and then optimize the shape of the pipe. The crack detection model developed has been applied to a crack detected in lab setting and machine learning model used has an accuracy of 98% using a random forest algorithm.

20 FOSSIL-FUELED POWER PLANTS↗

Localization Leads to Improved Distributed Detection Under Non-Smooth Distributions

We consider a detection network of sensors that measure intensity levels due to a source amidst background inside a two-dimensional monitoring area. The source intensity decays away from it possibly in discrete jumps, and the corresponding sensor measurements could be random due to the nature of source and background, or due to sensor errors, or both. The detection problem is to infer the presence of a source based on sensor measurements. In the conventional decision/detection fusion approach, detection decisions are made at the individual sensors using Sequential Probability Ratio Test (SPRT), and are combined at the fusion center using a Boolean fusion rule. We show that better detection can be achieved by utilizing sensor measurements at the fusion center, by first localizing the source and then utilizing a more effective SPRT. This approach leads to the detection performance superior to any Boolean detection fuser, under fairly general conditions: (i) smooth and non-smooth source intensity functions and probability ratios, and (ii) a minimum packing number of the state-space. We apply this method to improve the detection of (a) low-level point radiation sources amidst background radiation under strong shielding conditions, and (b) the well-studied Gaussian source amidst Gaussian background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Photon Haystack and Emerging Radiation Detection Technology

The resources devoted to interdicting special nuclear materials have increased considerably over the last several years in step with growing efforts to counter nuclear proliferation and nuclear terrorism. This changing landscape has led to a great deal of current research and development that aims to improve the effectiveness of technology now deployed worldwide. The interdiction of special nuclear materials is most commonly addressed by detecting and characterizing emitted gamma rays, but modest signature emissions can be obscured by attenuating material and must be differentiated from large and highly variable environmental background. While this makes gamma-ray detection of special nuclear materials a daunting technical challenge, a host of new detection technologies are now emerging. We thus review special nuclear material signatures, the physics of detection approaches, and detection performance metrics. The use of benchmark materials aids our discussion and comparison of detection methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid Crystal‐Based Detection of Antigens with ELISA Sensitivity

Abstract A highly sensitive label‐free liquid crystal (LC)‐based technique is presented for detecting Immunoglobulin G (IgG) antigens used to uncover viral infections. The effectiveness, sensitivity, and selectivity of this detection method is demonstrated with goat IgG antigen at concentrations as low as 100 pg ml −1 , which is comparable to the sensitivity of the current enzyme‐linked immunosorbent assay (ELISA). The sensor is fabricated by decorating a transmission electron microscopy grid immobilized glass surfaces with antibodies; the target antigen is detected by a liquid crystal suspended onto the grid. This is different from previous methods where the antigen is detected either at the LC‐aqueous interface or in an LC sandwich cell with an antibody/antigen‐decorated substrate. This new approach has advantages such as easy sample preparation, higher sensitivity, and better storage capabilities. Binding the target antigen to the antibody results in a reorientation of the LC director that is detected optically. In addition to demonstrating the sensitivity, the physical principle of the detection is also discussed. This technique may apply to detect virtually any antigen of interest.

36 MATERIALS SCIENCE↗

Serum anti-Ku86 is a potential biomarker for early detection of hepatitis C virus-related hepatocellular carcinoma

Highlights: Black-Right-Pointing-Pointer Overexpression of Ku86 in human liver cancer was shown by immunohistochemistry. Black-Right-Pointing-Pointer Serum anti-Ku86 was significantly elevated in early hepatocellular carcinoma. Black-Right-Pointing-Pointer Anti-Ku86 may be more sensitive than the conventional markers for early detection. Black-Right-Pointing-Pointer Serum anti-Ku86 significantly decreased after surgical resection of liver tumors. Black-Right-Pointing-Pointer Elevation of serum anti-Ku86 in other non-liver solid tumors was minimal. -- Abstract: Hepatocellular carcinoma (HCC), the predominant form of primary liver cancer, is one of the most common cancers worldwide and the third most common cause of cancer-related death. Imaging studies including ultrasound and computed tomography are recommended for early detection of HCC, but they are operator dependent, costly and involve radiation. Therefore, there is a need for simple and sensitive serum markers for the early detection of hepatocellular carcinoma (HCC). In our recent proteomic studies, a number of proteins overexpressed in HCC tissues were identified. We thought if the serum autoantibodies to these overexpressed proteins were detectable in HCC patients. Of these proteins, we focused on Ku86, a nuclear protein involved in multiple biological processes and aimed to assess the diagnostic value of serum anti-Ku86 in the early detection of HCC. Serum samples were obtained prior to treatment from 58 consecutive patients with early or relatively early hepatitis C virus (HCV)-related HCC and 137 patients with HCV-related liver cirrhosis without evidence of HCC. Enzyme immunoassays were used to measure serum levels of autoantibodies. Serum levels of anti-Ku86 antibodies were significantly elevated in HCC patients compared to those in liver cirrhosis patients (0.41 {+-} 0.28 vs. 0.18 {+-} 0.08 Abs at 450 nm, P < 0001). Setting the cut-off level to give 90% specificity, anti-Ku86 was positive in 60.7% of stage I solitary tumor <2 cm in diameter, whereas the sensitivities of alpha-fetoprotein (AFP) and protein induced by vitamin K absence or antagonist II (PIVKA-II) were 17.8% and 21.4%, respectively. The results of ROC analyses indicated the better performance of anti-Ku86 for early detection of HCC. Serum anti-Ku86 levels decreased after surgical resection of the tumors in the 12 HCC cases tested, Elevation of anti-Ku86 in solid tumors other than liver was minimal. Serum anti-Ku86 is a potential biomarker for early detection of HCV-related HCC. Further studies in a larger number of HCC patients with various etiologies are needed to further evaluate the diagnostic and pathophysiological roles of elevation of serum anti-Ku86 in early HCC.

60 APPLIED LIFE SCIENCES↗

Design and expression of a short peptide as an HIV detection probe

Highlights: •We designed a short fusion peptide (FP-50) for in vivo expression. •This peptide is a very promising component for detection of gp120 protein. •The detectable level is about 20–200 times lower than previously published methods. •It is a novel probe to detect HIV-1 gp120 during early stages of HIV infection. -- Abstract: To explore a low-cost novel probe for HIV detection, we designed and prepared a 50-amino acid-length short fusion peptide (FP-50) via Escherichia coli in vivo expression. It was employed as a novel probe to detect HIV-1 gp120 protein. The detectable level of gp120 protein using the FP-50 peptide was approximately 20–200 times lower than previously published methods that used a pair of monoclonal antibodies. Thus, this short peptide is a very promising component for detection of gp120 protein during early stages of HIV infection.

60 APPLIED LIFE SCIENCES↗

In situ multi-tier auto-ignition detection applied to dual-fuel combustion simulations

Here we use an anomaly detection methodology that is centered on analyzing fourth-order joint moments (co-kurtosis), particularly focusing on its application in auto-ignition of combustion problems with large numbers of species. Unsupervised anomaly detection is challenging to generalize across problem types and domains. A recent technique, centered on analyzing information in the fourth-order joint moment co-kurtosis, has shown promise, especially for high-dimensional scientific data. In this work we present developments to the co-kurtosis based anomaly detection method needed to make it effective and scalable for large-scale distributed scientific data, such as those generated by massively parallel simulations. An in situ co-kurtosis algorithm is employed as the anomaly detection method for identifying ignition kernels in simulations of turbulent combustion. Here, we extend an existing methodology which identifies regions of the domain where anomalies are present, and add another tier of anomaly detection where the individual samples contributing to the anomaly are identified. We apply this algorithm on-the-fly to a variety of turbulent reacting flow problems and compare it to the widely used (but significantly more expensive) chemical explosive mode analysis (CEMA). We demonstrate the ability of the method to detect and identify the onset of low and high temperature ignition which can be used for computational steering, as chemical and combustion anomalies occur intermittently at spatio-temporal locations unknown a priori. Finally, we apply our lightweight in situ algorithm to an exascale high-fidelity simulation with a total of 2.4 Trillion degrees of freedom, performed using an adaptive mesh refinement solver. Furthermore, through a scalability analysis, we show that the relative computational cost of this in-situ anomaly detection algorithm compared to an iteration of the reacting flow solver is negligible.

97 MATHEMATICS AND COMPUTING↗

Examining the potential for detecting simultaneous noble gas and aerosol samples in the international monitoring system radionuclide network

The purpose of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) is to establish a legally binding ban on nuclear weapon test explosions or any other nuclear explosions. The Preparatory Commission for the CTBT Organization (CTBTO PrepCom) is developing the International Monitoring System (IMS) that includes a global network of 80 stations to monitor for airborne radionuclides upon entry into force of the CTBT. All 80 radionuclide stations will monitor for particulate radionuclides and at least half of the stations will monitor for radioxenon. The airborne radionuclide monitoring is an important verification technology both for the detection of a radionuclide release and in the determination of whether the release event originates from a nuclear explosion as opposed to an industrial use of nuclear materials. Nuclear power plants and many medical isotope production facilities release radioxenon into the atmosphere. Low levels of a few particulate isotopes, such as iodine, may also be released. Detections of multiple isotopes are useful for screening the radionuclide samples for relevance to the Treaty. This paper examines the anticipated joint detections in the IMS of noble gas and particulate isotopes from underground nuclear explosions where breaches in the underground containment vents from low levels to up to 1% of the radionuclide inventory of the resulting fission products to the atmosphere. Detection probabilities are based on 844 simulated release events spaced out at 17 release locations and one year in time. Six different release (venting) scenarios, including two fractionated scenarios, were analyzed. When ranked by detection probability, 11 particulate isotopes and one noble gas isotope ( 133 Xe) appear in the top 20 isotopes for all six release scenarios. Using the 11 particulate isotopes and the one noble gas isotope, the IMS has nearly the same detection probability as when 45 particulate and 4 noble gas isotopes are used. Thus, a limited list of relevant radionuclides may be sufficient for treaty verification purposes. The probability that at least one particulate and at least one radioxenon isotope would be detected in the IMS from the release events ranged from 0.15 to 0.86 depending on the release scenario.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting drug-induced prolongation of the QRS complex: New insights for cardiac safety assessment

Background: Drugs slowing the conduction of the cardiac action potential and prolonging QRS complex duration by blocking the sodium current (I{sub Na}) may carry pro-arrhythmic risks. Due to the frequency-dependent block of I{sub Na}, this study assesses whether activity-related spontaneous increases in heart rate (HR) occurring during standard dog telemetry studies can be used to optimise the detection of class I antiarrhythmic-induced QRS prolongation. Methods: Telemetered dogs were orally dosed with quinidine (class Ia), mexiletine (class Ib) or flecainide (class Ic). QRS duration was determined standardly (5 beats averaged at rest) but also prior to and at the plateau of each acute increase in HR (3 beats averaged at steady state), and averaged over 1 h period from 1 h pre-dose to 5 h post-dose. Results: Compared to time-matched vehicle, at rest, only quinidine and flecainide induced increases in QRS duration (E{sub max} 13% and 20% respectively, P < 0.01–0.001) whereas mexiletine had no effect. Importantly, the increase in QRS duration was enhanced at peak HR with an additional effect of + 0.7 ± 0.5 ms (quinidine, NS), + 1.8 ± 0.8 ms (mexiletine, P < 0.05) and + 2.8 ± 0.8 ms (flecainide, P < 0.01) (calculated as QRS at basal HR-QRS at high HR). Conclusion: Electrocardiogram recordings during elevated HR, not considered during routine analysis optimised for detecting QT prolongation, can be used to sensitise the detection of QRS prolongation. This could prove useful when borderline QRS effects are detected. Analysing during acute increases in HR could also be useful for detecting drug-induced effects on other aspects of cardiac function. -- Highlights: ► We aimed to improve detection of drug-induced QRS prolongation in safety screening. ► We used telemetered dogs to test class I antiarrhythmics at low and high heart rate. ► At low heart rate only quinidine and flecainide induced an increase in QRS duration. ► At high heart rate the effects of two out of three antiarrhythmics were enhanced. ► Detection of a drug-induced prolongation of QRS was improved at high heart rate.

60 APPLIED LIFE SCIENCES↗

Probabilistic limit of detection for ricin identification using a shotgun proteomics assay

Robust and highly specific methods for the detection of the protein toxin ricin are of interest to the law enforcement community. In previous studies, methods based on liquid chromatography-tandem mass spectrometry shotgun proteomics have been proposed. The successful implementation of this approach relies on specific data evaluation criteria addressing (1) the quality of the mass spectrometric data, (2) the confidence of peptide identifications (peptide-spectrum matches), and (3) the number and sequence specificity of peptides detected. We present such data evaluation criteria, and use a novel approach to establish the limit of detection for this ricin assay. Specifically, we use logistic regression to determine the probability of detection for individual ricin peptides at different concentrations. We then apply basic rules from probability theory, combining these individual peptide probabilities into an overall assay limit of detection. This procedure yields an assay limit of detection for ricin at 42.5 ng on column or 21.25 ng/µL for a 2-µL injection. We also show that, in spite of the conventional wisdom that detergents are deleterious to mass spectrometric analyses, the presence of Tween-20 did not prevent detection of ricin peptides, and indeed assays performed in buffers that included Tween-20 gave better results than assays performed using other buffer formulations with or without detergent removal.

Heller, Natalie C.↗

Detection and Quantification of Biologically Active Botulinum Neurotoxin Serotypes A and B Using a Förster Resonance Energy Transfer-Based Quantum Dot Nanobiosensor

Botulinum neurotoxin (BoNT) is the most potent toxin known. The ingestion of food contaminated with biologically active BoNT causes foodborne botulism, which can lead to respiratory paralysis, coma, and death after ingestion of as little as 70 mu g for a 70 kg human. Because of its lethality and challenges associated with current detection methods, there is an urgent need for highly sensitive rapid screening techniques capable of detecting biologically active BoNT. Here, we describe a Forster resonance energy transfer-based nanobiosensor that uses quantum dots (QDs) and two specific quencher-labeled peptide probes to detect and differentiate two biologically active forms of BoNT, serotypes A and B, which were responsible for 80% of human foodborne botulism cases in the U.S. from 2012 to 2015. Each peptide probe contains an enzymatic cleavage site specific to only one serotype. QDs were selected based on the spectral overlap with the quenchers. In the presence of the target BoNT serotype, the peptide probe is cleaved and the quenching of QD photoluminescence (PL) is reduced, giving a signal that is easily detected by a PL spectrophotometer. This sensor performance was evaluated with light chains of BoNT/A and BoNT/B (LcA and LcB), catalytic domains of the respective serotypes. LcA and LcB were detected in 3 h with limits of detection of 0.2 and 2 ng/mL, respectively. The specificity of the sensor was evaluated, and no cross-reactivity from nontarget serotypes was observed with 2 h of incubation. Because each serotype-specific peptide is conjugated to a QD with a unique emission wavelength, multiple biologically active BoNT serotypes could be detected in one PL spectrum. The sensor was also shown to be responsive to BoNT/A and BoNT/B holotoxins. Good performance of this sensor implies its potential application as a rapid screening method for biologically active BoNT/A and BoNT/B in the laboratory and in the field.

botulinum neurotoxin↗

Laser-Induced Carbon-Based Smart Flexible Sensor Array for Multiflavors Detection

We report a flexible sensor array electronic tongue system that is fabricated on a polymer substrate by the laser direct writing process for multiflavor detection. Electronic tongue is a sensing system that is applied to detect different elements with the same sensor array. By analyzing responses from different measurement units, it enables a cross-sensitivity, namely, the ability of the system to responding to a range of different analytes in solution without specific functionalization of sensors. In this article, a six-unit sensing array system was fabricated by a laser direct writing process. Sensing units were introduced on a flexible polyamide surface. A high surface–volume ratio porous carbon structure was created by a laser-induced carbonization process, which provides stable conductive carbon electrodes with high sensitivity. Different surface treatments, such as gold plating, reduced-graphene oxide coating, and polyaniline coating, were accomplished for different measurement units. By applying principal component analysis, this sensing system shows a promising result for the detection of multiple flavors. The detection limit for each element is about 0.1 mM for NaCl and sugar solutions. Also, it is able to detect 10 –4 times diluted commercial table vinegar solution, which originally contains 5% acetic acid. The detection limit is theoretically lower than the human threshold of 10 mM for NaCl and sugar. Besides, the sensing system shows a high sensitivity and selectivity for mixed elements. Here, by mapping the data points, the sensor system could detect flavor combinations and provide a reliable prediction of analyte concentration ratios.

47 OTHER INSTRUMENTATION↗

Determination of X-ray detection limit and applications in perovskite X-ray detectors

X-ray detection limit and sensitivity are important figure of merits for perovskite X-ray detectors, but literatures lack a valid mathematic expression for determining the lower limit of detection for a perovskite X-ray detector. In this work, we present a thorough analysis and new method for X-ray detection limit determination based on a statistical model that correlates the dark current and the X-ray induced photocurrent with the detection limit. The detection limit can be calculated through the measurement of dark current and sensitivity with an easy-to-follow practice. Alternatively, the detection limit may also be obtained by the measurement of dark current and photocurrent when repeatedly lowering the X-ray dose rate. While the material quality is critical, we show that the device architecture and working mode also have a significant influence on the sensitivity and the detection limit. Our work establishes a fair comparison metrics for material and detector development.

47 OTHER INSTRUMENTATION↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical detection of leukemia oncogenes using enzyme-loaded carbon nanotube labels

Here we describe an ultrasensitive electrochemical nucleic acids assay amplified by carbon nanotubes (CNTs)-based labels for the detection of human acute lymphocytic leukemia (ALL) related p185 BCR-ABL fusion transcript. The carboxylated CNTs were functionalized with horseradish peroxidase (HRP) molecules and target-specific detection probes (DP) via diimide-activated amidation, and used to label and amplify target hybridization signal. The activity of captured HRP was monitored by square-wave voltammetry measuring the electroactive enzymatic product in the presence of 2-aminophenol and hydrogen peroxide substrate solution. The effect of DP and HRP loading of the CNT-based labels on its signal-to-noise ratio of electrochemical detection was studied systematically for the first time. Under optimized conditions, the signal-amplified assay achieved a detection limit of 83 fM targets oligonuecleotides and a 4-order wide dynamic range of target concentration. The resulting assay allowed a robust discrimination between the perfect match and a three-base mismatch sequence. When subjected to full-length (491 bp) DNA oncogene, the approach demonstrated a detection limit of approximately 33 pg of the target gene. The high sensitivity and specificity of assay enabled PCR-free detection of target transcripts in as little as 65 ng of mRNA extracted from positive ALL cell lines SUP-B15, in comparison to those obtained from negative cell lines HL-60. The approach holds promise for simple, low cost and ultrasensitive electrochemical nucleic acids detection in portable devices, point-of-care and early disease diagnostic applications.

Environmental Molecular Sciences Laboratory↗

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗