Diagnostic of fusion neutrons on JET tokamak using diamond detector

In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

Design of detectors at the electron ion collider with artificial intelligence

Abstract Artificial Intelligence (AI) for design is a relatively new but active area of research across many disciplines. Surprisingly when it comes to designing detectors with AI this is an area at its infancy. The electron ion collider is the ultimate machine to study the strong force. The EIC is a large-scale experiment with an integrated detector that extends for about ±35 meters to include the central, far-forward, and far-backward regions. The design of the central detector is made by multiple sub-detectors, each in principle characterized by a multidimensional design space and multiple design criteria also called objectives. Simulations with Geant4 are typically compute intensive, and the optimization of the detector design may include non-differentiable terms as well as noisy objectives. In this context, AI can offer state of the art solutions to solve complex combinatorial problems in an efficient way. In particular, one of the proto-collaborations, ECCE, has explored during the detector proposal the possibility of using multi-objective optimization to design the tracking system of the EIC detector. This document provides an overview of these techniques and recent progress made during the EIC detector proposal. Future high energy nuclear physics experiments can leverage AI-based strategies to design more efficient detectors by optimizing their performance driven by physics criteria and minimizing costs for their realization.

Instruments & Instrumentation↗

Investigation of energy weighting using an energy discriminating photon counting detector for breast CT

Purpose: Breast CT is an emerging imaging technique that can portray the breast in 3D and improve visualization of important diagnostic features. Early clinical studies have suggested that breast CT has sufficient spatial and contrast resolution for accurate detection of masses and microcalcifications in the breast, reducing structural overlap that is often a limiting factor in reading mammographic images. For a number of reasons, image quality in breast CT may be improved by use of an energy resolving photon counting detector. In this study, the authors investigate the improvements in image quality obtained when using energy weighting with an energy resolving photon counting detector as compared to that with a conventional energy integrating detector.Methods: Using computer simulation, realistic CT images of multiple breast phantoms were generated. The simulation modeled a prototype breast CT system using an amorphous silicon (a-Si), CsI based energy integrating detector with different x-ray spectra, and a hypothetical, ideal CZT based photon counting detector with capability of energy discrimination. Three biological signals of interest were modeled as spherical lesions and inserted into breast phantoms; hydroxyapatite (HA) to represent microcalcification, infiltrating ductal carcinoma (IDC), and iodine enhanced infiltrating ductal carcinoma (IIDC). Signal-to-noise ratio (SNR) of these three lesions was measured from the CT reconstructions. In addition, a psychophysical study was conducted to evaluate observer performance in detecting microcalcifications embedded into a realistic anthropomorphic breast phantom.Results: In the energy range tested, improvements in SNR with a photon counting detector using energy weighting was higher (than the energy integrating detector method) by 30%–63% and 4%–34%, for HA and IDC lesions and 12%–30% (with Al filtration) and 32%–38% (with Ce filtration) for the IIDC lesion, respectively. The average area under the receiver operating characteristic curve (AUC) for detection of microcalcifications was higher by greater than 19% (for the different energy weighting methods tested) as compared to the AUC obtained with an energy integrating detector.Conclusions: This study showed that breast CT with a CZT photon counting detector using energy weighting can provide improvements in pixel SNR, and detectability of microcalcifications as compared to that with a conventional energy integrating detector. Since a number of degrading physical factors were not modeled into the photon counting detector, this improvement should be considered as an upper bound on achievable performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams

Purpose: To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams.Methods: The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up/stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated.Results: A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy/min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters.Conclusions: The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

60 APPLIED LIFE SCIENCES↗

Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA

The GERmanium Detector Array (Gerda) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of 76 Ge. Germanium detectors made of material with an enriched 76 Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of theexperiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new 76 Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in Gerda during Phase I. The present article reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the 76 Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. Lastly, the detector performance fulfills the requirements needed for the physics goals of Gerda Phase II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the Effectiveness of Generalized Likelihood Ratio Test Detector Schemes in Seismic Event Detection and the Avoidance of Nontarget Signals

Cross-correlation techniques have played a long-standing and pivotal role in seismic event monitoring. However, the performance of correlation-based detectors is challenged by nuisance seismicity, or nontarget signals. Such detections are a problem when the mission is to automatically map events to the correct source region. Using aftershocks of the 2014 $M_w$ 6.0 South Napa, California, earthquake, we demonstrate the effectiveness of utilizing a dynamic correlation processor framework in a generalized likelihood ratio test (GLRT) detector configuration to minimize nontarget detections. A GLRT maximizes a detection statistic with respect to one or more unknown parameters. In this case, the detection statistic is a template signal match against the waveform in a window sliding over a data stream, and the unknown parameter is an index variable indicating group membership of the template event or events. Detected events are assigned to the event group that yields the largest detection statistic. In this work, our results show that a GLRT detector will outperform a suite of independently operating correlation and subspace detectors in terms of having a lower nontarget detection rate at a given missed detection rate. We also show that a GLRT detector composed of a few high-rank subspace detectors has a slightly higher nontarget detection rate, but a significantly lower missed detection rate, than a GLRT detector composed of many low-rank subspace detectors. The high-rank GLRT configuration produced impressive results even with marginal data (single channel, single station, and very low time bandwidth product), which bodes well for the utility of building efficient aftershock classification systems and global monitoring systems at larger scales. However, future work is required to assess performance at the regional scale and to assess the performance of the system at detecting target events not used in the detector template creation.

58 GEOSCIENCES↗

Development of Large Area Gas Electron Multiplier Detector and Its Application to a Digital Hadron Calorimeter for Future Collider Experiments

The UTA High Energy Physics Group conducted generic detector development based on large area, very thin and high sensitivity gas detector using gas electron multiplier (GEM) technology. This is in preparation for a use as a sensitive medium for sampling calorimeters in future collider experiments at the Energy Frontier as well as part of the tracking detector in Intensity Frontier experiments. We also have been monitoring the long term behavior of one of the prototype detectors (30cmx30cm) read out by the SLAC-developed 13-bit KPiX analog chip over three years and have made presentations of results at various APS meetings. While the important next step was the development of large area (1m x 1m) GEM planes, we also have looked into opportunities of applying this technology to precision tracking detectors to significantly improve the performance of the Range Stack detector for CP violation experiments and to provide an amplification layer for the liquid Argon Time Projection Chamber in the LBNE experiment. We have jointly developed 33cmx100cm large GEM foils with the CERN gas detector development group to construct 33cm x100cm unit chambers. Three of these unit chambers will be put together to form a 1m x 1m detector plane. Following characterization of one 33cmx100cm unit chamber prototype, a total of five 1m x 1m planes will be constructed and inserted into an existing 1m3 RPC DHCAL stack to test the performance of the new GEM DHCAL in particle beams. The large area GEM detector we planned to develop in this proposal not only gives an important option to DHCAL for future collider experiments but also the potential to expand its use to Intensity Frontier and Cosmic Frontier experiments as high efficiency, high amplification anode planes for liquid Argon time projection chambers. Finally, thanks to its sensitivity to X-rays and other neutral radiations and its light-weight characteristics, the large area GEM has a great potential for the use in medical imaging and homeland security, as well as satellite based astronomy experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. Among the different cryogenic detector types, Magnetic Micro-Calorimeters (MMCs) have the potential of faster count rates and better linearity. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. MMC gamma detectors measure the energy of absorbed gamma rays form the resulting change in magnetization of an erbium-doped gold (Au:Er) sensor. The signal is read out with a SQUID preamplifier and processed digitally with room temperature electronics (see inset figure 2). The objective of this project is to develop ultra-high energy resolution γ-detectors based on magnetic micro-calorimeters (MMCs) for accurate non-destructive isotope analysis (NDA). Since MMCs, like other cryogenic γ-detector technologies with operating temperatures <0.1 K, are intrinsically slow and have to be small for high resolution, special emphasis will be placed on questions that determine sensitivity and the potential for scaling to arrays. Objectives for FY14 were therefore to fabricate an improved version of MMC γ-detectors and test their energy resolution, maximum count rate, readout noise, crosstalk between pixels and linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis, FY14 Extended Annual Report

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K or below offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. We are developing cryogenic γ–detectors based on metallic magnetic calorimeters (MMCs), which have the potential of higher resolution, faster count rates and better linearity than other cryogenic detector technologies. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. Here we discuss the fabrication of a new generation of MMC γ–detectors in FY2014, and the resulting improvements in energy resolution and linearity of the new design. As an example of the type of NDA that cryogenic detectors enable, we demonstrate the direct detection of Pu-242 emissions with our MMC γ–detectors in the presence of Pu-240, and show that a quantitative NDA analysis agrees with the mass spectrometry

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization Collection in Detectors of the Cryogenic Dark Matter Search

Determining the composition of dark matter is at the forefront of modern scientific research. There is compelling evidence for the existence of vast quantities of dark matter throughout the universe, however it has so-far eluded all direct detection efforts and its identity remains a mystery. Weakly interacting massive particles (WIMPs) are a favored dark matter candidate and have been the primary focus of direct detection for several decades. The Cryogenic Dark Matter Search (CDMS) has developed the Z-dependent Ionization and Phonon (ZIP) detector to search for such particles. Typically made from germanium, these detectors are capable of distinguishing between electromagnetic background and a putative WIMP signal through the simultaneous measurement of ionization and phonons produced by scattering events. CDMS has operated several arrays of these detectors at the Soudan Underground Laboratory (Soudan, MN, USA) resulting in many competitive (often world-leading) WIMP exclusion limits. This dissertation focuses on ionization collection in these detectors under the sub-Kelvin, low electric field, and high crystal purity conditions unique to CDMS. The design and performance of a fully cryogenic HEMT-based amplifier capable of achieving the SuperCDMS SNOLAB ionization energy resolution goal of 100 eVee is presented. The experimental apparatus which has been used to record electron and hole properties under CDMS conditions is described. Measurements of charge transport, trapping, and impact ionization as a function of electric field in two CDMS detectors are shown, and the ionization collection efficiency is determined. The data is used to predict the error in the nuclear recoil energy scale under both CDMSlite and iZIP operating modes. A two species, two state model is developed to describe how ionization collection and space charge generation in CDMS detectors are controlled by the presence of “overcharged” D- donor and A+ acceptor impurity states. The thermal stability of these states is exclusive to sub-Kelvin operation, explaining why ionization collection in CDMS detectors differs from similar semiconductor detectors operating at higher temperature. This work represents a solid foundation for the understanding ionization collection in CDMS detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating the SuperCDMS Dark Matter Detector Response and Readout

Dark matter is one of the remaining great mysteries of modern physics. Cosmological and astrophysical evidence hints strongly at a new particle, or set of particles, unknown to the Standard Model, comprising some 80% of all of the matter in the universe. SuperCDMS is one of the world-leading direct-detection experiments attempting to directly measure interactions between dark and regular matter. SuperCDMS uses solid state crystalline detectors in a nearly-zero background environment to attempt to measure the particle properties of dark matter. The detectors themselves, however, are quite complex; and a very detailed understanding of the microscopic physics is helpful in analyzing the very rare events that occur within them. Furthermore, better understanding and modeling of the detectors can aid in the design and optimization of future iterations of the experiment. The SuperCDMS detectors are well-understood in ideal cases. However, an accurate understanding of the detector response to outlier events or under non-ideal conditions is important for a low-statistics experiment. This work describes the design and implementation of a low temperature condensed matter physics simulation library built on top of the popular Geant4 particle tracking framework. The library, named \Geant4 Condensed Matter Physics" or G4CMP, introduces several solid state concepts to the Geant4 framework such as crystal lattices, phonon quasiparticles, non-scalar elective masses, and implements several physics processes relevant to cryogenic temperature crystals. In addition to the physics library, which is intended for general use, this work also describes a full Monte Carlo simulation package for the SuperCDMS iZIP detectors which utilizes G4CMP at its core and also fully simulates the detector readout sensors. The document will begin with the canonical motivations for the cold dark matter hypothesis, followed by a description of the SuperCDMS experiment. It will then describe the microscopic physics inside of the SuperCDMS detectors, as well as details on their implementation in G4CMP. The full detector simulation with corresponding sensor readout will follow, along with plans for future work; including both scientific studies and improvements, as well as computational improvements and added efficiencies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗

Empirical Refinement of the GADRAS Detector Response Function

The Gamma Detector Response and Analysis Software (GADRAS) was augmented to enable empirical refinement of the Detector Response Function (DRF) for gamma-ray detectors. This capability is included in GADRAS starting with Version 18.8.2, which was released in February 2019 Empirical refinement enables improved computational accuracy for gamma-ray spectra when detectors exhibit characteristics that are essentially unique to a particular sensor. This report discusses how to perform the empirical refinement, and examples are presented for the following scenarios where empirical refinement is appropriate: Large plastic scintillators, which are generally composed of polyvinyl toluene (PVT), often exhibit low-energy peaks that are not associated with incident gamma rays. Regardless of whether they are artifacts produced by poor light collection or pulse processing methods, accurate spectral synthesis requires replication of these features; Some detectors, particularly those using Silicon Photomultipliers (SiPM), exhibit energy shifts of Compton edges and escape peaks relative to the same scintillator material attached to a photomultiplier tube. Empirical refinement compensates for these effects, which derive from nonlinearities in the detector response; The change in the DRF as a function of displacement of the source relative to the detector axis cannot always be replicated adequately using only the few shielding parameters that are used by the response function. Empirical refinement enables improved accuracy for computation of spectra during linear transits or when the detector is close to a large radiation source. This is a particularly important consideration for collimated detectors; and, Gamma-ray imagers exhibit complex relationships between spectral response and spatial locations. Empirical refinement enables substantial improvement of the DRF accuracy for imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗