Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

National-Tribal Critical Infrastructure Protection: Collaboration for Extraordinary National Security Benefit

This paper examines national and tribal collaborative opportunities to get ahead of the critical infrastructure insecurity problem. Recommendations are viewed through the lens of the Sandia Labs Tribal Cyber-Energy initiative and national security projects. Recommendations include 1) Collaboratively address national priority and shared challenges to gain faster and better solutions to national priority problems on a smaller yet comprehensive American Indian and Alaskan Native sovereign single-point of authority scale 2) Utilize newer standards-based technologies to provide scalable, capable, and manageable solutions for greatly expanded and connected national critical infrastructures 3) Employ Cyber-Physical-Resilient design preliminary analysis to define concept- to-disposition design requirements for preemptive critical infrastructure risk mitigation and baked-in security; 4) Develop data-centric protection to provide increased information asset protection as data shifts from data-owner operated on-premises infrastructure to virtual service provider data-steward owned and operated off-premises infrastructure; and 5) Balance shared solutions with the National Institute of Science and Technology (NIST) Cybersecurity and Risk Management frameworks, and the System Security Engineering Guidelines. As yet unallocated federal funding would support research, development, the timely application of National-Tribal critical infrastructure protection, and critical infrastructure Cyber disruption response and recovery with extraordinary mutual benefits for the foreseeable future. The Critical Infrastructure Insecurity Problem: Rapid modernization and expansive connectivity are due to advances in Information and Communications Technologies that have sweeping cyber impact across all critical infrastructure sectors. Supervisory Control and Data Acquisition and Industrial Control Systems are particularly impacted as systems long separated from the Internet are now being connected and computerized. Virtualization and mobility create a Data Everywhere-User Anywhere paradigm that has evaporated the enterprise network perimeter. There are multi-front technological challenges at play, where long depended on technologies simply don't scale to current needs resulting in a digital dichotomy of competing old and new standards. New standards-based technologies scale but are not as well-known or as widely deployed, which leaves decision makers, stakeholders, and the workforce in a quandary, caught mid-stream between the technological past and the virtual future. Rapid and expansive cyber threat accompanies disruptive change in connectivity and computational dependencies. A lack of action will exacerbate the problem if new technologies roll out without baked-in security design. The Risk: If National-Tribal CIP collaboration to design in security is not done, then an ongoing state of insufficient bolt-on security and elevated threat exposure will remain for years to come.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding How Organizations Handle Cybersecurity

If there is anything we can learn from the media, it is the frequency and severity of cyber-attacks is increasing and there are not enough qualified people to combat the risk organizations are facing. Current estimates say there are 3.5 million available cybersecurity related jobs globally and there has been a 350% growth in cybersecurity jobs since 2013 (Group, 2020). The Idaho Cyber Research Project (ICRP) is focused on finding an implementing solution to the problems in the workforce development pipeline. Our team consists of Cohort 2 of the ICRP, we are tasked with solving issues faced by organizations hiring new cyber personnel. To provide solutions to these issues we focused our research on four components of workforce availability and competency: resume and transcript analysis, apprenticeships, cyber incident response plan development, and adversarial mindset training. From this research we have produced the following focus areas and subsequent steps for each component of workforce capability: transcript and knowledge skills abilities (KSA) focused analysis, cybersecurity apprenticeships programs, the value of an adversarial mindset, and a guide to setting up cyber incident response plans for underprepared organizations. These solutions can be further developed and implemented to reduce the gap in workforce demand and talent.

97 MATHEMATICS AND COMPUTING↗

Advance Reactor Operational Technology Architecture Categorization

Seven generation III+ and generation IV nuclear reactor types, based on twelve reactor concepts surveyed, are examined using functional decomposition to extract relevant operational technology (OT) architecture information. This information is compared to existing nuclear power plants (NPPs) OT architectures to highlight novel and emergent cyber risks associated with next generation NPPs. These insights can help inform operational technology architecture requirements that will be unique to a given reactor type. Next generation NPPs have streamlined OT architectures relative to the current generation II commercial NPP fleet. Overall, without compensatory measures that provide sufficient and efficient cybersecurity controls, next generation NPPs will have increased cyber risk. Verification and validation of cyber-physical testbeds and cyber risk assessment methodologies may be an important next step to reduce cyber risk in the OT architecture design and testing phase. Coordination with safety requirements can result in OT architecture design being an iterative process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state, and to rapidly recover operational capabilities for essential functions after a successful attack. The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.” As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

DRE: Designing for Resilience through Emulation

Threats to cyber- and cyber-physical systems have continued to increase over the past decade. Now more than ever, it is vital that cyber-physical system stakeholders have the tools to deeply understand their systems and the threats they face. High-fidelity modeling capabilities are powerful tools to support system understanding and decision-making, but they currently lack scientifically rigorous experimentation practices and infrastructures. The purpose of the project Designing for Resilience through Emulation (DRE) was to bring together past research and existing tools into a new pipeline to improve our ability to quantitatively evaluate future cyber scenarios. DRE offers new integrated capabilities for large dataset collection, noise studies, sensitivity analysis, uncertainty quantification, and surrogate modeling using a cyber-physical system emulation environment. These new capabilities significantly improve our ability to establish the credibility of the answers derived from emulation environments, ultimately leading to better critical decision support.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Resilience Through Data-Driven, Intelligent Designed Control: A Formal Methods Approach

The PNNL and GTRI team developed a strategy to integrate temporal logic rule specification for detection of cyber-intrusion in the source code and control algorithms of CPS using advanced cyber-data. The GTRI team utilized its capabilities in rule synthesis and temporal logic specifications for software assurance and verification to detect and predict impact of cyber-intrusions and malware in the computational and control algorithms of cyber-physical systems. The team also developed a testing and verification approach that could be used to validate the suggested approach against a realistic use-case CPS showcasing improvements in system impact prediction performance. Temporal logic offers a compact expression of events in absolute and relative time and has a formalized translation to state machines. As such, temporal logic rules can feasibly be synthesized to any system as a rule engine, with the process being formally verified to be correct. The goal here is to utilize temporal logic rules to detect cyber-attacks and manipulations in the computational algorithms and provide real-time software assurance and verification guarantees.

97 MATHEMATICS AND COMPUTING↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BioSecure Digital Twin: Manufacturing Innovation and Cybersecurity Resilience

U.S. national security, prosperity, economy, and well-being require secure, flexible, and resilient Biopharmaceutical Manufacturing. The COVID-19 pandemic reaffirmed that the biomedical production value-chain is vulnerable to disruption and has been under attack from sophisticated nation-state adversaries. Current cyber defenses are inadequate, and the integrity of critical production systems and processes are inherently vulnerable to cyber-attacks, human error, and supply chain disruptions. The following chapter explores how a BioSecure Digital Twin will improve U.S. manufacturing resilience and preparedness to respond to these hazards by significantly improving monitoring, integrity, security, and agility of our manufacturing infrastructure and systems. The BioSecure Digital Twin combines a scalable manufacturing framework with a robust platform for monitoring and control to increase U.S. biopharma manufacturing resilience. Then, the chapter discusses some of the inherent vulnerabilities and challenges at the nexus of health and advanced manufacturing. Next, the chapter highlights that as the Pandemic evolves, we need agility and resilience to overcome significant obstacles. This section highlights an innovative application of Cyber Informed Engineering to developing and deploying a BioSecure Digital Twin to improve the resilience and security of the biopharma industrial supply chain and production processes. Finally, the chapter concludes with a process framework to complement the Digital Twin platform, called the Biopharma (Observe, Orient, Decide, Act) OODA Loop Framework (BOLF), a four-step approach to decision-making outputs from the Digital Twin. The BOLF will help end users leverage twin technology by distilling the available information, focusing the data on context, and rapidly making the best decision while remaining cognizant of changes that can be made as more data becomes available.

99 GENERAL AND MISCELLANEOUS↗

Cybersecurity concerns for the energy sector in the maritime domain

The world has seen a number of high-profile maritime disasters in recent months and years, and has felt the impact of them. At the same time, the world has also seen a number of high-profile cyberattacks. It has felt their impact, as well. And, likely no sector has been more affected by the maritime and cyber incidents than the energy sector, as fuel prices often spike or trough, and access to energy resources can become an instant source of concern, tension, or even conflict. As energy sectors—in all their forms—continue to rely on the maritime domain or even increase that reliance, they must be mindful that traditional maritime threats—like piracy, theft, and weather events—are not the only threats they face today. Maritime cybersecurity concerns are among the most potentially disruptive to energy-sector interests and, yet, are among the least understood and least addressed. This paper identifies nine areas in which the energy sector faces harmful cyber vulnerabilities in the maritime domain, to provide enough insight and examples to allow for action to be taken to reduce the risk of harm from these different vulnerabilities. The paper develops the example of offshore wind energy to model how to assess cyber considerations more fully. Ultimately, it concludes with a series of recommendations that offer policymakers, energy-sector actors, and security and law-enforcement professionals steps to minimize the exposure of the maritime energy sector to harmful cyberattacks.

99 GENERAL AND MISCELLANEOUS↗

Power and Communications Hardware-in-the-Loop CPS Architecture and Platform for DER Monitoring and Control Applications: Preprint

The rapid growth of distributed energy resources (DERs) has prompted increasing interest in the monitoring and control of DERs through hybrid smart grid communications. The deployment of communications and computation has transformed the traditional physical power grid into a smart cyber-physical system (CPS). To fully understand the interdependency between physical grid and cyber netowrks, this study designed a power and communications hardware-in-the-loop (PCommHIL) CPS architecture, which enables the flexible verification of DER monitoring and control with hybrid communications architectures and Internet protocols. Design, development and case study of a PCommHIL testbed for the DER coordination are discussed in detail, and the proposed platform integrates DER devices, Advanced Metering Infrastructures (AMIs), and a suite of hybrid communications networks for distribution automation applications. Case study on DER situational awareness and Volt-Var control validates the efficacy of this proposed PCommHIL platform with hybrid communications designs. Results show that the HAN communication technologies play a critical role in hybrid designs and it is the bottleneck for DER applications. High performance communication technologies are highly recommended to be applied in the HAN for enhanced monitoring and real-time control of DERs.

AMIs↗

Mental Models for Managing Grid Cybersecurity Risk - ARC Industry Forum, Cybersecurity and Energy Transition

A proper mental model of the concepts of cyber risk and its components of threat and exploitability and consequence is necessary to allocate limited resources to different security activities, especially when considered alongside reliability and regulatory and economic risks. Understanding the consequence and frequency different risks are realized also helps align the right mitigations to the right risks. Cyber-informed engineering (CIE) is an emerging method to “engineer out” cyber risk across product and system lifecycles, and INL has a portfolio of programs operationalizing CIE’s principles for the energy sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Idaho National Laboratory Energy Cybersecurity Programs Update

This brief presentation provides a status update on three Idaho National Laboratory energy cybersecurity programs of particular interest to NERC Reliability and Security Technical Committee annual in-person Security Groups summit. Public information on the following three programs is included: Cybersecurity for Operational Technology Environments (CyOTE™) program Cyber-Informed Engineering (CIE) Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, and associated high-level information on the Energy Software Bill of Materials POC, Executive Order 14017, and the Energy Cyber Sense Act

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗