Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned

Historically, regulatory barriers have precluded nuclear plant safety-related (SR) Instrumentation and Control (I&C) system modernizations. These barriers have been largely addressed by industry and United States Nuclear Regulatory Commission (NRC) efforts, including development of the License Amendment Request (LAR) Alternate Review (AR) process for digital I&C upgrades. The U.S. Department of Energy (DOE) and the Idaho National Laboratory (INL) are supporting a SR I&C pilot upgrade at the Limerick Generating Station (LGS) to demonstrate this process and capturing associated lessons learned for the benefit of industry. In 2021, a paper summarizing lessons learned as captured in INL/EXT-20-59809, Safety Related Instrumentation & Control Pilot Upgrade Initial Scoping Phase Implementation Report and Lessons Learned was presented at the 12th NPIC & HMIT conference. It is recommended that readers of this paper review reference 1 or the associated Nuclear Journal paper for context. This paper summarizes activities performed and lessons learned for the conceptual design phase and portions of the detailed design phase as captured in INL/RPT-23-XXXX, “Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned.” The portions of the effort covered by reference 2 include conceptual design phase activities from December 2020, through completion in November 2021, and detailed design activities through September 2022. These efforts and associated detailed documentation in reference 3 are intended to support similar industry upgrades as a foundation stone for a Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant total cost of ownership.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase shifter for antenna beam steering

Wide band Array Antenna operates in Ku-band (10.7-12.7 GHz) frequency composed of N×N radiating elements. This antenna aims at the reception of television satellite signals. The goal of this research is to provide better possibility of electronic beam control instead of manual or mechanical control, and design compact and low cost phase shifters to be inserted in the feeding network of this antenna. The electronic control of the phase shifter will allow the control of beam steering. The emphasis of this project will be done at the beginning on the design of a good phase shifter in Ku band. The aim of this research is to define, simulate, release and measure a continuous phase shifter. Better reflection loss, low transmission loss, low Cost of array antennas, large range of phase-shifter, phase flatness and bandwidth will be achieved by providing better gain.

42 ENGINEERING↗

Operability and control in process intensification and modular design: Challenges and opportunities

Abstract In this article, the importance of considering operability and control criteria in the analysis and design of intensified and modular processes is discussed. We first analyze the impact on operability of key factors including: (i) degrees of freedom, (ii) process constraints, (iii) numbering up vs. scaling up, and (iv) dynamic/periodic operation. Comparative examples are presented to showcase the pros and cons in intensified/modular systems vs. their conventional counterparts from operability and control aspects. Then we look into metrics and tools to address these challenges such as: (i) flexibility analysis, (ii) operability‐based design, and (iii) advanced model‐based control. Considering different conceptual design stages as synthesis intensification, steady‐state design, and dynamic operational optimization, we highlight the need to incorporate different levels of operability considerations. Future research opportunities and perspectives are also identified, particularly emphasizing the importance of a holistic strategy for integrated design, operability, and control of intensified and modular process systems.

Pistikopoulos, Efstratios N.↗

MS/MS-Assisted Design of Sequence-Controlled Synthetic Polymers for Improved Reading of Encoded Information

In order to improve their MS/MS sequencing, structure of sequence-controlled synthetic polymers can be optimized based on considerations regarding their fragmentation behavior in collision-induced dissociation conditions, as demonstrated here for two digitally encoded polymer families. In poly(triazole amide)s, the main dissociation route proceeded via cleavage of the amide bond in each monomer, hence allowing the chains to be safely sequenced. However, a competitive cleavage of an ether bond in a tri(ethylene glycol) spacer placed between each coding moiety complicated MS/MS spectra while not bringing new structural information. Changing the tri(ethylene glycol) spacer to an alkyl group of the same size allowed this unwanted fragmentation pathway to be avoided, hence greatly simplifying the MS/MS reading step for such undecyl-based poly(triazole amide)s. In poly(alkoxyamine phosphodiester)s, a single dissociation pathway was achieved with repeating units containing an alkoxyamine linkage, which, by very low dissociation energy, made any other chemical bonds MS/MS-silent. Structure of these polymers was further tailored to enhance the stability of those precursor ions with a negatively charged phosphate group per monomer in order to improve their MS/MS readability. Increasing the size of both the alkyl coding moiety and the nitroxide spacer allowed sufficient distance between phosphate groups for all of them to be deprotonated simultaneously. Because the charge state of product ions increased with their polymerization degree, MS/MS spectra typically exhibited groups of fragments at one or the other side of the precursor ion depending on the original α or ω end-group they contain, allowing sequence reconstruction in a straightforward manner. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of control strategies for wave energy converters

In this study, we employ a numerical model to compare the performance of a number of wave energy converter control strategies. The controllers selected for evaluation span a wide range in their requirements for implementation. Each control strategy is evaluated using a single numerical model with a set of sea states to represent a deployment site off the coast of Newport, OR. A number of metrics, ranging from power absorption to kinematics, are employed to provide a comparison of each control strategy’s performance that accounts for both relative benefits and costs. The results show a wide range of performances from the different controllers and highlight the need for a holistic design approach which considers control design as a parallel component within the larger process WEC design.

13 HYDRO ENERGY↗

Strain response of stretchable micro-electrodes: Controlling sensitivity with serpentine designs and encapsulation

The functionality of flexible electronics relies on stable performance of thin film micro-electrodes. This letter investigates the behavior of gold thin films on polyimide, a prevalent combination in flexible devices. The dynamic behavior of gold micro-electrodes has been studied by subjecting them to stress while monitoring their resistance in situ. The shape of the electrodes was systematically varied to examine resistive strain sensitivity, while an additional encapsulation was applied to characterize multilayer behavior. The realized designs show remarkable tolerance to repetitive strain, demonstrating that curvature and encapsulation are excellent approaches for minimizing resistive strain sensitivity to enable durable flexible electronics.

36 MATERIALS SCIENCE↗

A fully integrated oven controlled microelectromechanical oscillator -- Part I. Design and fabrication

Our paper reports the design and fabrication of a fully integrated oven controlled microelectromechanical oscillator (OCMO). This paper begins by describing the limits on oscillator frequency stability imposed by the thermal drift and electronic properties (Q, resistance) of both the resonant tank circuit and feedback electronics required to form an electronic oscillator. An OCMO is presented that takes advantage of high thermal isolation and monolithic integration of both micromechanical resonators and electronic circuitry to thermally stabilize or ovenize all the components that comprise an oscillator. This was achieved by developing a processing technique where both silicon-on-insulator complementary metal-oxide-semiconductor (CMOS) circuitry and piezoelectric aluminum nitride, AlN, micromechanical resonators are placed on a suspended platform within a standard CMOS integrated circuit. Operation at microscale sizes achieves high thermal resistances (~10 °C/mW), and hence thermal stabilization of the oscillators at very low-power levels when compared with the state-of-the-art ovenized crystal oscillators, OCXO. This constant resistance feedback circuit is presented that incorporates on platform resistive heaters and temperature sensors to both measure and stabilize the platform temperature. Moreover, the limits on temperature stability of the OCMO platform and oscillator frequency imposed by the gain of the constant resistance feedback loop, placement of the heater and temperature sensing resistors, as well as platform radiative and convective heat losses are investigated.

42 ENGINEERING↗

Autonomous Microgrid Restoration Using Grid-Forming Inverters and Smart Circuit Breakers

The proliferation of distributed inverter-based resources (IBRs) raises the questions if these IBRs can be used to blackstart microgrids and distribution feeders after major outages. In this paper, we propose and evaluate an autonomous microgrid restoration concept using grid-forming (GFM) IBRs and smart circuit creakers (SCBs). The concept is first explored in simulation platform and then a hardware testbed containing actual GFM inverters is developed to demonstrate these functionalities. A combination of dispatchable virtual oscillator control (dVOC) and droop-based control schemes have been designed for GFM inverter controls in the software simulations and hardware testbed. Subsequently, operation of SCBs using two distinct principles have been demonstrated that can restore or connect portions of the network.

black start↗

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Data Lake Design for the Accelerator Control System

In this modern world, the user expects faster processing and real-time response to operate accelerator control devices. The existing framework with its infrastructure does not have the ability to satisfy these future needs. Therefore, modernization is required to reach industry standards and develop a modular framework that can provide flexibility and dynamic scalability. The data lake architecture, comprising three layers, ingestion, processing, and data consumption, provides flexibility and scalability to meet current and future demands for the accelerator control system.

Jaikar, Amol [Fermilab]↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗