At least 811 records · Page 45

Commercial PACE Financing for New Construction

This fact sheet provides an overview for building owners and developers to take advantage of commercial property assessed clean energy (CPACE) financing for new construction, adaptive reuse, or renovation projects.

Commercial PACE, CPACE, Microgrid, Renewables, new↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility Managed Distributed Energy Resources Intelligent Community - UDERMS iCommunity (Final Technical Report)

The Utility Managed Distributed Energy Resources Intelligent Community (UDERMS iCommunity) project, led by PacifiCorp and supported by the U.S. Department of Energy’s Building Technologies Office (Award No. DEEE0009782), aimed to demonstrate an integrated, utility-managed “behind-the-meter” distributed energy resource (DER) program connecting multifamily, commercial, institutional, and industrial buildings to deliver grid services and improve energy efficiency.

14 SOLAR ENERGY↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

A review of select human-building interfaces and their relationship to human behavior, energy use and occupant comfort

In recent years, research has emerged to quantitatively and qualitatively understand occupants' interactions with buildings. However, there has been surprisingly little research on building interfaces and how their design, context (e.g., location), and underlying logic impact their usability and occupants’ perceived control, as well as the resulting comfort and energy performance. This means that research is needed to better understand how occupants interact with building interfaces in both commercial and residential applications; both applications are important to address as there are many differences in interface types, level of control and understanding, and even expectations of engagement. Herein, this paper provides a cursory review and discussion of select common building interfaces: windows, window shades/blinds, thermostats, and lighting controls. The goal of this paper is to review literature related to these human-building interfaces to explore interface characteristics, current design and use challenges, and relationships between building interfaces and occupants. Human-building interface interactions are complex, more research is needed to understand design, use, and characteristics. Common themes emerged throughout the literature review to explain occupant interactions (or lack of interactions) with building interfaces, which included thermal and visual comfort, ease and access of control, interface/control placement, poor interface/control design, lack of understanding, and social-behavioral dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MODELING AND TESTING OF A NOVEL ULTRA-LOW TEMPERATURE SCO2 OPPOSING PISTON EXPANDER

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

01 COAL, LIGNITE, AND PEAT↗

DEVELOPMENT OF A 25 MWTH FLAMELESS PRESSURIZED OXY-COMBUSTION PILOT

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

20 FOSSIL-FUELED POWER PLANTS↗

Safe, Low-Cost, High Energy-Density, Solid-State Li-Ion Batteries

We developed intrinsically safe, robust, low-cost, high-energy-density solid-state Li-ion batteries, by integrating high conductivity garnet-type solid Li ion electrolytes and several different cathodes in tailored microstructures, fabricated by low-cost supported thin-film ceramic techniques, to overcome the primary technological barriers to next generation battery technology. In this ARPA-E project we employed Li-garnet solid-state electrolytes pioneered by one of the co-investigators (Thangadurai) which has room temperature (RT) conductivity of ~10 -3 S cm -1 . The highly stable garnet SSE allowed the use of S, NMC, and other cathodes with Li metal anodes without stability or flammability concerns. We studied the garnet’s stability when exposed to CO 2 and humidity (with or without an ALD coating) and showed that the material can be processed in ambient air for most steps prior to battery assembly, significantly reducing production costs. We extensively studied and scaled up the synthesis of the powder and explored external suppliers of garnet to determine the best pathway for commercial success. We used low-cost and scalable tapecasting fabrication methods to create porous-dense-porous “trilayer” solid electrolyte microstructures with a ~20 μm separating dense layer, and >70% porosity porous layers to host the electrodes. These scalable multilayer ceramic fabrication techniques, without need for dry rooms or vacuum equipment, also provide for dramatically reduced manufacturing costs. The tailored microstructured electrode supports (scaffold) increased interfacial area ~50x, overcoming the high impedance typical of planar geometry SSLiBs, resulting in record-setting 10 mA/cm 2 lithium cycling in a symmetric cell. We expanded our tapecasting ability and showed tapes >25m in length by the end of the project. We demonstrated the ability to sinter garnet without the use of a garnet powderbed, which could have been a major obstacle and waste of material at scale. At the same time, we expanded the size of our trilayers from coin cells (0.7 cm 2 ) to the full format design (30 cm 2 ). To develop full cells, we demonstrated 250 Wh/kg at room temperature with commercial NMC electrode films in a bilayer configuration. Similarly, we demonstrated 280 Wh/kg trilayer Li-S cells at room temperature with >90% capacity retention over 300 cycles. At 90°C we demonstrated 350 Wh/kg with a Li-S trilayer. The high thermal stability of the garnet electrolyte also enabled extended cycling (400 cycles) of a Li-TiS 2 cell at 150 °C, showcasing the exceptional safety and nonflammability of the solid-state trilayer batteries. Ion Storage Systems has taken this technology and knowledge to produce trilayer garnet electrolytes and is building out facilities to commercialize high performance solid state batteries. ISS has hired a strong staff, identified and communicated with a large number of potential partners, and successfully secured follow-on funding.

25 ENERGY STORAGE↗

A Markov framework for generalized post-event systems recovery modeling: From single to multihazards

State-dependent models can be used to represent the system recovery process as a series of stochastic transitions from lower to higher functional states. However, the applications of these models have been limited in scope and there is a lack of a generalized recovery modeling framework. A generalized framework would permit a robust forecasting of systems and system-of-systems recovery under multiple hazards, and more broadly, would contribute to community disaster preparedness. This paper develops a generalized post hazard-event recovery modeling framework based on state-dependent Markov-type processes. We then apply the proposed framework to solve a spectrum of problems that range from hind-casting single-system recovery following a single hazard event to forecasting post-event trajectories under multiple hazards and modeling the recovery of a system-of-systems. First, Markov chains are used to hind-cast the observed recovery for a portfolio of buildings affected by the 2014 South Napa, California, earthquake. Next, Markov processes are used to formulate a parametric post hazard-event recovery model, which can be updated using Bayesian statistics when relevant datasets become available. Semi-Markov processes are then used to develop a more general model of single hazard recovery, which accounts for the intensity of the loading and level of damage caused by the event. Semi-Markov processes with non-renewal features are then used to account for multihazard interactions in a post-event recovery model, and applied to a case study that involves a community in Charleston, South Carolina. Lastly, Markov-type processes are combined with Bayesian networks to model the recovery of residential, commercial, educational, and industrial buildings (system-of-systems) following a hazard event. Overall, these applications demonstrate the versatility of the Markov framework towards handling recovery problems with varying levels of complexity.

42 ENGINEERING↗

Dual-Band Electrochromism in Hydrous Tungsten Oxide

The independent modulation of visible and near-infrared light by a single material, termed dualband electrochromism, is highly desirable for smart windows to enhance the energy efficiency of buildings. Tungsten oxides are commercially important electrochromic materials, exhibiting reversible visible and near-infrared absorption when electrochemically reduced in an electrolyte containing small cations or protons. The presence of structural water in tungsten oxides has been associated with faster electrochromic switching speeds. Here, we find that WO 3 ·H 2 O, a crystalline hydrate, exhibits dual-band electrochromism unlike the anhydrous WO 3 providing a heretofore unexplored route to tune the electrochromic response of tungsten oxides. Absorption of near-infrared light is achieved at low Li + /e - injection, followed by the absorption of visible light at higher Li + /e - injection as a result of an electrochemically-induced phase transition. We propose that this dual-band modulation is possible due to the more open structure of WO 3 ·H 2 O as compared to WO 3 . This facilitates a more extended solid solution Li + insertion regime that benefits the modulation of near-infrared radiation via plasmon absorption. Higher degrees of Li + /e - insertion lead to polaronic absorption associated with localized charge storage. Furthermore, these results inform how structural factors influence the electrochemically induced spectral response of transition metal oxides and the important role of structural water beyond optical switching speed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Coal-Based Commercial Facade Panels and Architectural Components (Phase I Final Report)

Semplastics has developed, tested, and documented the viability for commercialization of a new class of composite architectural panel materials that use coal as the primary constituent. This project produced sample panels using these novel materials that comprise 55% coal by mass (71% carbon by mass) and are comparable in dimensions to commercially available materials, while displaying superior mechanical strength, significant weight savings, and better insulating ability at a competitive cost. Phase I moved this coal-based composite materials technology from a Technology Readiness Level (TRL) of 3 to TRL 5. Semplastics’ new coal-based composite materials display an array of high-performance characteristics, including light weight, mechanical durability, temperature stability, and water resistance. These new materials require less energy to produce than comparable commercial products and could be manufactured on existing conventional plastic resin processing equipment in commercial quantities. The coal particles are completely encapsulated in ceramic from a polymer-derived ceramic (PDC) precursor, then bonded together by another inorganic resin. The material can be molded and cured to produce fireproof components such as ceiling panels, facades, and extruded underlayment, blocking, and backer boards, as well as other architectural design components such as moldings. The project included the production of sample panels for proof of concept, testing of the panels to show their improved characteristics, and development of a scale-up strategy to demonstrate the viability of the coal-based panels as a commercial alternative to existing building materials.

36 MATERIALS SCIENCE↗

U.S. Department of Energy Solar Decathlon Competition Guide 2019-2020

This Solar Decathlon will offer collegiate teams a unique experience to develop critical career skills, learn from both national experts and peers, and gain valuable insights from world-class thought leaders. This document details the Rules for the Design Challenge and Build Challenge.

14 SOLAR ENERGY↗

Effect of rice husk ash-derived activator on the structural build-up of alkali activated materials

Highlights: • Filtered and unfiltered sodium silicate solutions were synthesised from RHA. • The dissolution efficiency of RHA in NaOH solution was 76.3%. • RHA-derived activator showed a structural build-up comparable to the commercial activator in AAM pastes. • The undissolved residues in the unfiltered RHA-derived activator increased the yield stress. • Comparable compressive strength and early age gel formation were observed from both commercial and RHA-derived solutions. Waste-derived sodium silicates (SSs) were synthesised from rice husk ash (RHA) to produce alkali activated materials (AAMs) using fly ash and slag as precursors. The effects of these SSs on the structural build-up were investigated by monitoring the evolution of the viscoelasticity, ultrasonic pulse waves, setting time, and infrared spectra. Two types of RHA derived SSs (filtered SS and unfiltered SS) were prepared to investigate the effect of the undissolved residue on the hardening process. The derived SS contained a large portion of monomer silicate species. The results showed that the structural build-up mechanism was comparable between the AAMs activated by the filtered SS and a commercial SS. The unfiltered SS increased the yield stress of the paste by up to 10 times. However, the residues in the unfiltered SS had insignificant impacts on the gel formation and compressive strength when using identical SiO{sub 2}/Na{sub 2}O and Na{sub 2}O/binder ratios in the mix design.

36 MATERIALS SCIENCE↗