Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Collective flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Overset grid applications on distributed memory MIMD computers

Analysis of modern aerospace vehicles requires the computation of flowfields about complex three dimensional geometries composed of regions with varying spatial resolution requirements. Overset grid methods allow the use of proven structured grid flow solvers to address the twin issues of geometrical complexity and the resolution variation by decomposing the complex physical domain into a collection of overlapping subdomains. This flexibility is accompanied by the need for irregular intergrid boundary communication among the overlapping component grids. This study investigates a strategy for implementing such a static overset grid implicit flow solver on distributed memory, MIMD computers; i.e., the 128 node Intel iPSC/860 and the 208 node Intel Paragon. Performance data for two composite grid configurations characteristic of those encountered in present day aerodynamic analysis are also presented.

Chawla, Kalpana↗

Flow and Heat Transfer Experimental Study for 3D-Printed Solar Receiving Tubes With Helical Fins at Internal Surface

3D-printing technology was applied to fabricate novel solar thermal collection tubes that have internal heat transfer enhancement fins and external surfaces with high solar absorptivity and low emissivity due to the ability to use different materials in one tube. Helical fins were selected to introduce circumferential flow and thus minimize the circumferential temperature difference of the tube that receives sunlight on one side. The structures of the helical fins were previously optimized from computational fluid dynamics (CFD) analysis with the objective of low entropy production rate by looking for high heat transfer coefficient and relatively lower pressure loss. High-temperature alloy, Inconel-718, was used to 3D print the tubes, which can resist corrosion for the potential application of molten chloride salts as heat transfer fluid. Experimental tests were carried out using water as the heat transfer fluid with the high heat flux provided by a tubular furnace heater. The tested Reynolds number ranges from 3.9 × 10 3 to 6.1 × 10 4 . Heat transfer coefficients of up to 2.8 times that of the smooth tube could be obtained with the expense of increased pressure loss compared to that of the smooth tube. The total system entropy generation can be significantly reduced due to the benefit of heat transfer enhancement that is greater than the expenses of the increased pressure loss. The experimental results of the 3D-printed heat transfer tubes confirmed the CFD-based results of fin optimization. Furthermore, the novel heat transfer tube is recommended for application in concentrating solar power systems.

14 SOLAR ENERGY↗

Cl-36 in polar ice, rainwater and seawater

Concentrations of the cosmogenic radioisotope Cl-36 in Antarctic ice, rain, and an upper limit of the seawater value are determined using van de Graaff accelerator high energy mass spectrometry. Cl-36 concentrations in Antarctic ice range between 2.5 to 8.7 x 10 to the 6th atoms Cl-36/kg, while those concentrations in samples collected at the Alan Hills ice field locations where meteorites have been brought to the surface by glacial flow and ablation are found to vary by more than a factor of three. This variation is attributed either to the effects of atmospheric mixing and scavenging or to radioactive decay in old ice. The Cl-36 concentration found in a present sample of rainwater is much lower than that reported in samples collected in the early 1960's, suggesting the occurrence of a decrease in the concentration of atmospheric Cl-36 derived from nuclear weapons tests over this time period.

Finkel, R. C.↗

Validation of the HyRAM+ physics models for use with propane

The Hydrogen Risk Assessment Model Plus (HyRAM+) toolkit combines quantitative risk assessment with simulations of unignited dispersion, ignited turbulent diffusion flames, and indoor accumulation with delayed ignition of fuels. HyRAM+ is differentiated from HyRAM in that it includes models and leak data for other alternate fuels. The models of the physical phenomena need to be validated for each of the fuels in the toolkit. This report shows the validation for propane which is being used as a surrogate for autogas, which is a mixture of propane and butane and used in internal combustion engines in vehicles. For flame length comparisons, five previously published experiments from peer reviewed journals were used to validate our models. The validation looked at flame lengths and flame widths with respect to different leak diameters, mass flow rates, and source pressures. Most of the sources included more than one set of experimental data, which were collected using different methods (CCD cameras, IR visualization etc.). In general, HyRAM+ overpredicts the flame lengths by around 65%. For heat and radiation models, we compared the heat flux and radiation data reported from two different sources to the values calculated by HyRAM+. For higher mass flow rates, the HyRAM+ calculated flame length results gave a better estimate of what is found in the experiments (65% error), but a higher error (85%) is observed between the HyRAM+ calculated lengths and the experimental flame lengthsfor lower mass flows. Some differences can be attributed to outdoor environmental effects (i.e. wind speed) and uncertainties in jet flame shapes. The propane flame trajectory is predicted for a high Reynolds number case with Re = 12,500 and a low Reynolds number case where Re = 2,000. The Re=12,500 case which is momentum dominated matches well with the experimental flame trajectory, but the agreement for the bouancy driven low Reynolds number case is not as good. Dispersion modeling for unignited propane was also analyzed. We compared the mole fraction, mixture fraction, mean velocity, concentration half width, and inverse mass concentration over an axial distance from different credible journals to the values calculated by HyRAM+. The results display good agreement but generally, HyRAM+ predicts a wider profile for mole fraction and mixture fraction experiments. Overall, HyRAM+’s results are reasonable for predicting the flame length, heat flux, flame trajectory, and dispersion for propane and can be used in risk analyses

08 HYDROGEN↗

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics, including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics in weightlessness is limited to the left IJV assessed ~45 and ~150 days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness and therefore a risk for short-duration missions and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we investigated the effects of acute weightlessness during parabolic flight on the right and left IJV in 12 healthy subjects. Baseline ultrasound images were obtained on the ground (1g) in the seated and supine postures and during 0g parabolic flight. Each data collection session included 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the bilateral IJVs. RESULTS There was a similar pattern of response in the left and right IJV area across postures and g-levels. IJV area increased from seated to supine by 0.74 mm2 (95% CI: 0.56 to 0.91 mm2, p<.001) and increased further during weightlessness by 0.29 mm2 (95% CI: 0.11 to 0.47 mm2, p=.0015). IJV Doppler images revealed stagnant flow in the left IJV in one subject during 0g exposure that was not present during any imaging on the ground; the right IJV continued to show pulsatile, nominal flow patterns in both 0g and 1g. CONCLUSIONS This study characterized the immediate effect of the weightlessness-induced headward fluid shift on venous parameters in the left and right IJV. The left IJV appears to be more susceptible to flow alterations, including stagnant flow, during both short and long-duration exposure to weightlessness that may contribute to the risk of thrombosis inflight.

K Marshall-Goebel↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized, preprocessed by a small onboard computer, and then sent wirelessly to a desktop computer, where the collected data are analyzed and displayed. In addition to the raw data on temperature, pressure, flow, and mole fractions of oxygen and carbon dioxide, the display can include volumetric oxygen consumption, volumetric carbon dioxide production, respiratory equivalent ratio, and volumetric flow rate of exhaled gas.

Dietrich, Daniel L.↗

Regional-scale flows in mountainous terrain. Part 1: A numerical and observational comparison

This study uses observed data and a numerical simulation to examine the generation of thermally driven flows across the Colorado mountain barrier on meso-beta to meso-alpha scales. The observations were collected from remote surface observing systems at exposed mountaintop locations throughout the state of Colorado, over the summers of 1984-88, as part of the Rocky Mountain Peaks Experiment (ROMPEX). The data show the development of a recurrent circulation system across the Colorado mountain barrier, operating on a diurnal timescale. From the observations, the basic structure of the flow system appears as a daytime inflow toward the highest terrain, and a nocturnal outflow away from it. However, when examined in detail, the flow system exhibits more unusual behavior, especially west of the barrier crest. Here, winds in the early evening are occasionally observed to onset abruptly from an easterly direction, generally counter to the upper-level winds. Observations from ROMPEX for 26 August 1985 are used to provide comparison data for a numerical simulation with the Regional Atmospheric Modeling System (RAMS). This three-dimensional case study experiment is initialized with data from the National Meteorological Center and incorporates two-way interactive grid nesting. From the observed data and case study simulation, four distinct phases of the regional-scale circulation system have been identified. In the development phase, a deep mountain-plains solenoid is generated through terrain heating along the Front Range. This circulation system transforms in the late afternoon transition phase into a westward-propagating density current (WPDC). The third phase, called the 'density-current propagation phase,' occurs as the WPDC moves westward across the mountains, leaving in its wake strong southeasterly flow at the mountaintop level. This current appears to be the cause of the peculiar easterly component winds found in the ROMPEX mountaintop observations along the western slope. In the final late-night adjustment phase, the WPDC dissipates near the western edge of the Colorado mountains and steady southerly flow evolves over the high mountain terrain. This southerly flow is the steady response to the differential heating that develops between the low-lying plains and the intermountain region.

Bossert, James E.↗

Field and Model Data Associated with the Manuscript “Drivers of Streamflow Intermittency in Humid Regions: 2. Evaluating Controls on Flow Persistence in an Urbanized Catchment”

This package contains field data, modeling files, and scripts supporting the investigation of the drivers of streamflow intermittency in an urbanized catchment. It includes the field data collected from electrical resistivity tomography (ERT) surveys, distributed temperature sensing (DTS), continuous self-potential (SP) monitoring, groundwater and stilling well. In addition, it contains the data and results of the coupled water- and electrical-flow model developed using the COMSOL Multiphysics and Advanced Terrestrial Simulator (ATS), as well as software files and Jupyter notebooks used to process the data and generate figures in the manuscript submitted for peer review. The data archive is organized in the following directories: 1) Climate Includes hourly precipitation and daily evapotranspiration time series (2024 – 2025) provided as CSV files, alongside a text file detailing dataset units. 2) Coupled_model Field_Application subfolder contains the ATS XML input scripts, data files, output data for the SP site. It also contains the Jupyter notebook (Plot_final_calib.ipynb) to visualize the results of the modeled SP, stream-groundwater exchange and moisture content. The flow model simulation is executed using the ATS XML scripts and the included Python script (generate_data_set.py) to convert ATS output to COMSOL-ready input. COMSOL Multiphysics template (.m can only be used with COMSOL with MATLAB) is executed using the ATS output data to simulate the potential field. 3) Discharge Includes the electrical conductivity (EC) time series (provided as CSV files) from salt slug injections. It also includes the Jupyter notebook (Discharge_process.ipynyb) used to estimate discharge. All discharge measurements collated into rating_curve_processed.csv 4) DTS Contains collated DTS data including raw Stokes and anti-Stokes measurement (provided as .h5 file). It also includes DTS processing.ipynb, a Jupyter notebook for calibrating the DTS data using dts_calibration Python package. cooler_calibration.csv is the DTS calibration CSV used in the calibration sequence. 5) ERT Contains raw resistivity data (provided as CSV files), spatial location of each of the electrodes (provided as CSV files), and files used for the resistivity inversion. 6) Slug_test Includes the slug test data at all the groundwater wells provided as CSV files, as well as the Jupyter notebook (Slug_test.ipynb) for calculating hydraulic conductivity. 7) SP Contains the SP data collected in field at the SP sites (provided as CSV files). 8) Well_data Contains two subfolders: 1) Raw, which provides unprocessed pressure, electrical conductivity and temperature timeseries downloaded from the loggers in all the groundwater and stilling wells, and 2) Processed, which contains sorted, QA/QC timeseries data for each well. The data archive also contains data_process.ipynb, a Jupyter notebook used for field data analysis and generating figures (plotting well, SP, climate, and discharge data, as well as calculating head gradient at sites with nested groundwater wells). Note: Code files (.ipynb, .py, .xml) can be opened in any standard code editor, .exo file can be viewed using Paraview, .h5 files can be opened using HDFView software and h5py Python package, and .resipy file can be opened with the open-source ResIPy software.

ATS↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

The application of flow cytometry for kelp meiospore isolation

The goal of this study was to evaluate flow-cytometric techniques for isolating individual kelp meiospores into 96-welled plates. Previously reported low success rates for sorting tens of thousands of meiospores at a time have been improved by technological developments, specifically, the low nozzle pressure of the commercially available, JSAN (Bay Bioscience Co. Ltd) instrument. We monitored growth and gametophyte development post-sorting for 10 months. Our data demonstrate that successful kelp meiospore isolations of up to 76% viability can be achieved with flow-cytometry. This method can save time as compared to traditional, manual isolations using pipettes and improves confidence that self-fertilized individuals will not contaminate specific crosses of resulting gametophytes. Our results highlight a new application for the flow cytometer to produce clonal kelp gametophytes with direct applications for germplasm and culture collection development.

59 BASIC BIOLOGICAL SCIENCES↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Groundwater regulates interannual variations in evapotranspiration in a riparian semiarid ecosystem

Dryland ecosystems are an important component of Earth’s carbon, water, and energy budgets. Changes in hydroclimatic conditions can significantly alter land surface fluxes in these ecosystems. In regions with groundwater-river water exchange, land surface fluxes are strongly modulated by groundwater table fluctuations in response to river stage variations; however, interactions between fluxes and groundwater remain poorly understood in drylands. Here, we use eddy covariance data collected in paired upland and riparian semiarid ecosystems during two years with contrasting river flow conditions to examine interactions among river stage conditions, water table dynamics, meteorological drivers, and ecosystem fluxes. Elevated groundwater availability resulting from groundwater-surface water exchange at the riparian site enhanced the latent heat flux (LE, the energy form of evapotranspiration), which was sustained longer in the growing season during both years. At the upland site, mean LE during the dry season differed by less than 2% between the two years. In contrast, at the riparian site contrasting river flow conditions resulted in a 41% difference in peak monthly LE between the two years. The two-year mean LE in the summer at the riparian site was twice that at the upland site. Carbon uptake (NEP) and LE were well correlated at the upland site during both years, but at the riparian site enhanced summertime LE during the high river flow year did not correspond t enhanced NEP. Our results demonstrate that enhanced groundwater availability modulated by river stage variability is a critical driver of land surface fluxes in semiarid riparian ecosystems.

Missik, Justine E.↗

Experimental Investigation of Gaseous Mixtures of Ethane, Methane, and Carbon Dioxide as an Alternative to Conventional Fuel in Spark Ignition Engines

This study investigates the viability and performance of certain synthetic fuels in spark ignition internal combustion engine based stationary power generation wherein the fuel comprises a mixture of methane and ethane in high dilutions of carbon dioxide (CO 2 ). The fuel of concern is a byproduct of a novel method for producing ethylene from ethane. The byproduct gas mixture has a concentration of approximately 41% CO 2 , 40% ethane, and 5% methane by weight along with other minor compounds. Varying mixtures of ethane and methane combined with between 42% and 46% by weight CO 2 were used to evaluate the viability and efficiency of this fuel to operate in existing internal combustion engines as a means of reducing emissions and increasing industrial process efficiency. A 13 hp gasoline generator was repurposed as a test stand by incorporating a modified fuel induction system and instrumentation for data collection. A gas metering and mixing system was installed to precisely control the mass flow of gases induced into the engine. Various instrumentations were installed to monitor in-cylinder pressure, temperature at various locations, emissions, and fuel and airflow rates. Varying fuel mixtures and loads were tested and compared to gasoline. It was found that under a high load, the mixed gas was able to generate comparable thermal efficiency and power to gasoline. But under no load or a part load condition the indicated thermal efficiency was found to be about 21% lower than that of gasoline. Further, the mixed gas also resulted in up to 50% reduction in CO and NOx emissions when compared to gasoline.

42 ENGINEERING↗

Geochemistry and Strontium Isotopes for Coal Creek Watershed, Colorado, 2021-2022

The geochemistry and strontium isotope data for Coal Creek Watershed, Colorado, consists of cation, anion, and 87Sr/87Sr isotope values from samples collected at 8 stream location along Coal Creek, samples from two groundwater springs within the watershed, and a shallow subsurface piezometer. All stream and spring samples were collected between June and October, 2021, and the shallow, near stream piezometer sample was collected in July of 2022. These data were collected to evaluate how groundwater contributions to Coal Creek originating from shallow vs deep flow paths respond seasonal drying. Understanding of groundwater-surface water interactions in montane systems in critical for the future of water availability in the Western US as groundwater contributions are expected to become more important for sustaining summer stream flows. This data package contains: (1) a csv of all cation samples; (2) a csv of all anion samples; (3) a csv of all 87Sr/87Sr isotope samples; and (4) a csv of locations for each sampling site. The dataset additionally includes a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.

54 ENVIRONMENTAL SCIENCES↗

Particle Size and Density Measurement

This project has developed a miniature gravity settling classifier (flow cell) and flow system that separates slurry particles by settling rate into six different Cuts. The settling rates for particles in each Cut were determined from COMSOL computational fluid dynamics (CFD) modeling of the flow in the flow cell together with particle tracking for particles of differing settling rates. For particles collected in each Cut, the particle concentration and size distribution were measured. The effective particle densities from each Cut are calculated from their respective CFD modeled settling rates using a relationship between the unhindered settling rate, particle size distribution (PSD), and effective density. The particle size and density distribution (PSDD) of the slurry sample is then calculated by combining the size and density distributions determined for the particles collected in each of the settling rate Cuts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ALSEP data management.

Nine million measurements a day are transmitted from each functional ALSEP on the moon and continuously collected on earth for use in long-term scientific analysis. Periodically, this massive flow of intricate data is examined on a real-time basis to evaluate ALSEP performance and to study the need for new commands to any of the ALSEP systems. A worldwide complex of facilities and personnel has the challenging task of efficient and timely data processing and dissemination. This paper describes facility characteristics and support activities and details certain constraints imposed on ALSEP hardware design by data handling requirements. The highlights of the first two years of lunar data management are reviewed.

Murtaugh, C. R.↗

Water vapor diffusion membranes, 2

Transport mechanisms were investigated for the three different types of water vapor diffusion membranes. Membranes representing porous wetting and porous nonwetting structures as well as dense diffusive membrane structures were investigated for water permeation rate as a function of: (1) temperature, (2) solids composition in solution, and (3) such hydrodynamic parameters as sweep gas flow rate, solution flow rate and cell geometry. These properties were measured using nitrogen sweep gas to collect the effluent. In addition, the chemical stability to chromic acid-stabilized urine was measured for several of each type of membrane. A technology based on the mechanism of vapor transport was developed, whereby the vapor diffusion rates and relative susceptibility of membranes to fouling and failure could be projected for long-term vapor recovery trials using natural chromic acid-stabilized urine.

Holland, F. F.↗