Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Certified”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Saltstone third quarter calendar year 2019 (3QCY19) toxicity characteristic leaching procedure (TCLP) results

The aqueous waste from Tank 50 (salt solution) is sampled quarterly for transfers to the Saltstone Production Facility (SPF). Salt solution is treated at SPF and disposed of in the Saltstone Disposal Facility (SDF). Per request of customer, X-TAR-Z-00008, Revision 01, two SDF waste form (saltstone) samples were prepared in the Savannah River National Laboratory (SRNL) from the Tank 50 Waste Acceptance Criteria (WAC) sample and Z-Area premix material for the third quarter of calendar year 2019 (3QCY19). One sample contained a Full Premix which included 10:45:45 (by weight) of cement, slag and fly ash. The second sample contained 60:40 (by weight) of slag and fly ash only referred to as the “Cement-Free grout sample”. Results from this technical report support Task 2: ‘Grout Leaching Analyses’ of the Task Technical Request (TTR) prepared by Savannah River Remediation (SRR). After a 28 day cure, a sample of each of the SDF waste forms was collected and shipped to a certified laboratory for analysis using the Toxicity Characteristic Leaching Procedure (TCLP). The 3QCY19 saltstone (Full Premix) and the Cement-Free grout samples met the South Carolina (SC) Code of Regulations for Hazardous Waste Management Regulations (HWMR) 61-79.261.24 and 61-79-268.48 requirements for a non-hazardous waste form with respect to Resource Conservation and Recovery Act (RCRA) metals and Underlying Hazardous Constituents (UHCs), and also met the SPF WAC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Lawrence Livermore National Laboratory ABSL-3 Tissue Digester Run Data Report

Purpose: Provide data from a water run of the LLNL tissue digestor to confirm operational status for possible extension of Medical Waste permit, since the annual recertification maintenance and testing could not take place due to the shelter-in-place of the tissue digester vendor who is located outside of California. This is a unique medical waste device and the vendor who certifies our other medical waste equipment (permitted autoclaves), does not service the tissue digester.

59 BASIC BIOLOGICAL SCIENCES↗

NA-22 Write for Consortium Efforts

We are asked to look into the improvements for the measurement of Pu of a variety of material types (MT): MT41 (Pu-242, 20 – 60% enriched), MT42 (Pu-242 > 60% enrichment), and MT-82 (Np-237). Many of these are legacy items that were packaged years ago (Fig 1&2), and when the items are re-packaged for long-term storage, they must be re-measured using either NDA (nondestructive analysis methods or radiochemical methods. It is of interest to improve the NDA and radiochemistry to reduce the un-certainty in the measurements, as in the case of larger items (250 g to 2 kg items) the uncertainty in measurements makes it difficult to certify the mass of the material down to the 0.5 g accountability requirement per DOE orders by only doing NDA measurement. It would be of interest to look into methods to improve the detection of these materials, which would not only benefit the weapon manufacturing community, but also has the ability to significantly improve the non-proliferation community.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lawrence Livermore National Laboratory ABSL-3 Tissue Digester 12 June 2020 Run Data Report, Report 2

Purpose: Provide data from a water run of the LLNL tissue digester to confirm operational status for possible extension of Medical Waste permit, since the annual recertification maintenance and testing could not take place due to the shelter-in-place of the tissue digester vendor who is located outside of California. This is a unique medical waste device and the vendor who certifies our other medical waste equipment (permitted autoclaves), does not service the tissue digester.

59 BASIC BIOLOGICAL SCIENCES↗

Lawrence Livermore National Laboratory ABSL-3 Tissue Digester 12 June 2020 Run Data Report

Purpose: Provide data from a water run of the LLNL tissue digester to confirm operational status for possible extension of Medical Waste permit, since the annual recertification maintenance and testing could not take place due to the shelter-in-place of the tissue digester vendor who is located outside of California. This is a unique medical waste device and the vendor who certifies our other medical waste equipment (permitted autoclaves), does not service the tissue digester.

59 BASIC BIOLOGICAL SCIENCES↗

Lawrence Livermore National Laboratory ABSL-3 Tissue Digester (8 July 2020 Run Data Report, Report 3)

Purpose: Provide data from a water run of the LLNL tissue digester to confirm operational status for possible extension of Medical Waste permit, since the annual recertification maintenance and testing could not take place due to the shelter-in-place of the tissue digester vendor who is located outside of California. This is a unique medical waste device and the vendor who certifies our other medical waste equipment (permitted autoclaves), does not service the tissue digester.

42 ENGINEERING↗

Monthly Sewer Monitoring Report for LLNL Livermore Site (Jun 2020)

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyze these compliance samples, and results are used to establish LLNL compliance with the 2019 - 2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L).

54 ENVIRONMENTAL SCIENCES↗

A Parameterization Study of Sew-EZ Materials: Types #6 and #8

Two material types identified by Sew-EZ were tested in various configurations, and under various conditions, by Sandia National Laboratories (SNL). The primary focus of this study was to assess the filtration performance of these two materials and identify if they perform similarly to certified N95 respirators. Testing was conducted on two systems which use distinctly different techniques to characterize the aerosol penetration characteristics of materials: a) R&D Filtration System: A large-scale R&D filtration system was used with testing parameters that mimicked NIOSH guidelines, where possible. Efficiency data as a function of particle size was attained using NaC1 as the test aerosol and a Scanning Mobility Particle Sizer (SMPS) for measurements. A more detailed system description can be found in Omana et al. 2020. b) Automated Tester: A commercial, automated filter tester (100Xs, Air Techniques International) was used to provide penetration/efficiency data for Sew EZ materials. The 100Xs aerosolizes a polydisperse NaC1 aerosol with a consistent concentration and size profile. The 100Xs manual (Air Techniques International 2018) states, "The aerosol particle size and distribution are designed to meet all requirements as defined in the relevant sections of NIOSH 42 CFR, Part 84 (pg. 32)."

36 MATERIALS SCIENCE↗

Evaluation of the Performance of the SAVY Container Subjected to Various Impact Events using Finite Element Methods

The SAVY container is a Safety Class Design Feature utilized both inside engineered features and outside engineered features (e.g. gloveboxes) at TA-55 Plutonium Facility Building 4. These containers were certified as low damage ratio containers by demonstrating their ability to retain material after exposure to impacts and elevated temperatures resulting from a design basis seismic event. Original testing of the SAVY did not evaluate the effects of various facility specific insults to the SAVY while within a DOT Type A Container, caused either by design basis accident or an operational mishap. These insults include: 1. Impact of a structural I-beam (drum upright & drum on side); 2. Impact of a section of Positive Pressure Chilled Water Pipe (PPCWS); 3. Forklift fork tine impact; 4. Fuel truck impact. Abaqus Explicit Dynamics Finite Element Analysis was performed on a nested SAVY/DOT Type 7A container configuration to assess the structural integrity of the SAVY under the accident conditions listed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Behavioral Health/Employee Assistance. Interim Program Report FY 2020

The Sandia National Laboratories' (SNL) Corporate Behavioral Health Program is a workplace- based program that: 1) provides Employee Assistance Program (EAP) services including early identification and resolution of personal concerns which may impact job performance, 2) assists managers and the organization in addressing productivity issues, and 3) supports the SNL commitment to provide a safe and healthful work environment. The program is offered to approximately 13,500 employees in New Mexico. The Behavioral Health Program is a corporate program combining services in NM and CA. It is integrated with other occupational health and clinical services including disability, disease management and preventive health programs. In addition, Sandia's Behavioral Health Program provides critical management consultation and psychological assessment services for external organizations including Human Resources, the Department of Energy and Security through the Clinical Evaluation (CE) process, Human Reliability Program (HRP), Protective Force Program, Workplace Violence/Threat Assessment Team (TAT), and Insider Threat Working Group programs. The program supports Sandia National Laboratories' mission to safeguard national security, the environment, and the public; it is a proactive approach to early identification, intervention and assessment. Importantly, it reduces barriers to accessing mental health services and assists with reducing health care costs attributed to illness or injuries related to unhealthy lifestyles and behaviors. The team is comprised of a professional staff including a licensed Clinical Psychologist, a licensed professional clinical counselor (LPCC) and a licensed Marriage and Family counselor (MFT) who is also a Certified Employee Assistance Professional and who holds a doctorate in counseling psychology.

99 GENERAL AND MISCELLANEOUS↗

A Bezier Curve Informed Melt Pool Geometry to Model Additive Manufacturing Microstructures Using SPPARKS

Additive manufacturing is a transformative technology with the potential to manufacture designs which traditional subtractive machining methods cannot. Additive manufacturing offers fast builds at near final desired geometry; however, material properties and variability from part to part remain a challenge for certification and qualification of metallic components. AM induced metallic microstructures are spatially heterogeneous and highly process dependent. Engineering properties such as strength and toughness are significantly affected by microstructure morphologies resulting from the manufacturing process Linking process parameters to microstructures and ultimately to the dynamic response of AM materials is critical to certifying and qualifying AM built parts and components and improving the performance of AM materials. The AM fabrication process is characterized by building parts layer by layer using a selective laser melt process guided by a computer. A laser selectively scans and melts metal according to a designated geometry. As the laser scans, metal melts, fuses, and solidifies forming the final geometry in a layerwise fashion. As the laser heat source moves away, the metal cools and solidifies forming metallic microstructures. This work describes a microstructure modeling application implemented in the SPPARKS kinetic Monte Carlo computational framework for simulating the resulting microstructures. The application uses Bzier curves and surfaces to model the melt pool surface and spatial temperature profile induced by moving the laser heat source; it simulates the melting and fusing of metal at the laser hot spot and microstructure formation and evolution when the laser moves away. The geometry of the melt pool is quite flexible and we explore effects of variances in model parameters on simulated microstructures.

36 MATERIALS SCIENCE↗

Qualification of Mitutoyo RA-2200 Roundness Tester Measuring Instrument for Clad Vent Set Cup Roundness and Flatness Inspections

Roundness (or circularity) and flatness measurements are made as part of the dimensional inspection process to certify that iridium alloy Clad Vent Set (CVS) cups meet the dimensional requirements of Iridium Alloy Cup Drawing M2D920101A005, Rev. 4 (see Figure 1). A Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester is specified in the cup inspection Procedure GPHS-C-3624/25, Rev. 25 for roundness (dimension 16) and flatness (dimension 17). The Mahr Federal (Providence, RI) MarForm MMQ 400 Formtester stopped functioning in 2019. A new Mitutoyo RA-2200 Roundness Tester was purchased to replace the MMQ 400. Evaluations were conducted to qualify the new RA-2200 for CVS cup dimensional inspection work. The criterion for qualification was to ensure that the new RA-2200 instrument would yield roundness and flatness inspection results equivalent to or better than the predecessor MMQ 400 instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2019 Site Sustainability Plan (Narrative)

Clean energy and sustainability, long at the core of the United States (U.S.) Department of Energy (DOE) mission and championed at Sandia National Laboratories (SNL), are reinforced in Executive Order (EO) 13834, Efficient Federal Operations. Though no longer in effect as of May 2018, EO 13693, Planning for Federal Sustainability in the Next Decade, is referenced throughout this document. DOE's Strategic Sustainability Performance Plan (SSPP) embodies the Department's sustainability commitment and establishes the foundation for DOE to meet the objectives of the EO. The SNL Site Sustainability Plan (SSP) is prepared annually to support DOE's Strategic Sustainability Performance Plan (SSPP) and the National Nuclear Security Administration's (NNSA) sustainability goals and broader sustainability program. Accordingly, the content of this SSP covers the SNL contributions toward meeting the DOE sustainability goals, including the DOE requirement to comply with EO 13834. This SSP fulfills the contractual requirement for National Technology & Engineering Solutions of Sandia, LLC (NTESS), the management and operating (M&O) contractor for SNL, to deliver an annual sustainability plan to the NNSA and Sandia Field Office (SFO). The SNL Environmental Management System (EMS) implements sustainable practices for enhancing environmental, energy, and transportation management performance. SNL's EMS is a quality-based system modeled on the Plan-Do-Check-Act structure for continuous improvement. The EMS is a part of SNL's Integrated Safety Management System and functions within the overall Laboratory Operating System. The SNL EMS is International Organization for Standardization (ISO) 14001 certified and incorporates all relevant federal, state, local, and DOE requirements. The EMS is coordinated and implemented through 20 environmental programs, five of which are included within the scope of this SSP: Air Quality Compliance (AQC); Materials; Sustainability & Pollution Prevention; Energy and Water; Fleet Services; and, Waste Management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Silicon Carbide Multilayer Piping for 900°C Supercritical CO 2 Brayton Cycle: Chemical Compatibility in CO 2

The US Department of Energy's Office of Nuclear Energy is interested in developing supercritical carbon dioxide (sCO 2 ) power cycles that can achieve higher cycle efficiencies and lower costs than the traditional steam Rankine cycles. For the application of an sCO2 energy conversion system with a Very High Temperature Gas Reactor (VHTGR), turbine inlet temperatures over 850°C may be required. Consequently, it is necessary to demonstrate structural materials, including turbine inlet piping, that can be code certified at operating temperatures up to 900°C at sCO 2 pressures up to 42 MPa (6100 psi). There are very few metal alloys that retain their strength at these high temperatures, and that are chemically compatible with sCO 2 .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Draft Electric Rule 21 Test Protocols for Advanced Inverter Functions

Disclaimer: The following document includes draft certification protocols and should not be viewed as a consensus-based performance standard. Distributed energy resources (DERs), such as photovoltaic (PV) systems, when deployed in a large scale, are capable of significantly influencing the operation of bulk and local power systems. Looking to the future, European and American stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. One of the jurisdictions considering modifications to the DER interconnection requirements is California. To determine what changes could improve electric grid reliability and allow greater penetrations of renewable energy, the California Public Utilities Commission (CPUC) and the California Energy Commission (CEC), in conjunction with consultant Frances Cleveland, convened the Smart Inverter Working Group (SIWG) in January 2013. The SIWG--composed of state agencies, utility engineers, national laboratories, manufacturers, trade associations, and advocacy groups--provided the CPUC a set of recommendations in early 2014 1 . The recommendations included specific advanced DER functions and interoperability requirements, along with a proposed timeline, for California to add new capabilities to grid-interconnected DER. On August 18, 2014 the three California Investor-Owned Utilities (IOUs)--Pacific Gas and Electric Company (PG&E), Southern California Edison Company (SCE) and San Diego Gas & Electric Company (SDG&E)--drafted a Advice Letter filing to the CPUC setting forth revisions to Electric Tariff Rule 21 to conform to the seven recommendations made by the Working Group 2 . After a comment period, the CPUC issued an update to the IOU recommendations 3 . At the time of this publication, there was no final legal ruling on the CPUC Rulemaking (R.) 11-09-011 ("Order Instituting Rulemaking on the Commission's Own Motion to improve distribution level interconnection rules and regulations for certain classes of electric generators and electric storage resources"). In the U.S., Nationally Recognized Test Laboratories (NRTLs) independently verify products to safety and functional standards. PV inverters are certified to Underwriters Laboratories (UL) Standard 1741 4 . However, new advanced inverter functions described in the SIWG and IOU proposals are not included in this standard, so there is a critical need to develop test protocols for these functions in preparation of a positive ruling by the CPUC. Through a California Solar Initiative Grant, Sandia National Laboratories (Sandia or SNL), Underwriters Laboratories (UL), Electric Power Research Institute, Inc. (EPRI), Xanthus Consulting, SunSpec Alliance, Loggerware, and utility and PV inverter manufacturers have collaborated to draft this certification protocol for the Rule 21 SIWG Phase 1 advanced inverter functions. This report also includes test procedures for Phase 2 and Phase 3 functions that will be demonstrated later in the CSI4 project. This collaborative effort was performed in close junction with the UL 1741 Standards Technical Panel (STP) working group. This document represents a snapshot of the draft testing protocols at the time of publication and not a consensus certification protocol for advanced inverters. 1 California Public Utilities Commission, "Recommendations for Updating the Technical Requirements for Inverters in Distributed Energy Resources, Smart Inverter Working Group Recommendations," Filed 7 Feb 2014. 2 J.J. Newlander, R.G. Litteneker, S.W. Walter, M. Dwyer, Joint motion of Pacific Gas and Electric Company (U 39 E), Southern California Edison Company (U 338 E) and San Diego Gas & Electric Company (U 902 E) regarding implementation of smart inverter functionalities, Rulemaking 11-09-011 Advice Letter, 18 July, 2014. 3 J.T. Sullivan, CPUC Rulemaking 11-09-011 Agenda ID #13460, 13 Nov, 2014. 4 Underwriters Laboratories Std. 1741 Ed. 2, "Inverters, Converters, Controllers and Interconnection System Equipment for use with Distributed Energy Resources," 2010.

42 ENGINEERING↗

Waste stream knowledge assessment memorandum

To ensure that the Acceptable Knowledge (AK) documentation relating to the management of potentially reactive, corrosive, ignitable, and incompatible transuranic (TRU) waste materials is adequate, current, and accurately described in existing AK Summary Reports (AKSR), an Acceptable Knowledge Assessment (AKA) will be performed for each waste stream with unshipped containers or containers that are not emplaced. The primary focus of the AKA will be to review and verify the AK documentation associated with the historic and current use of absorbents, immobilization products, and neutralization agents used in the management of potentially corrosive, ignitable, or reactive liquids. In addition, the AKA will assess the specific management of other potentially incompatible or reactive materials generated at the Building 6580 Hot Cell Facility (HCF) and repackaged at the Auxiliary Hot Cell Facility (AHCF) at the Sandia National Laboratory (SNL). The AKA is performed in accordance with Section 4.13 of the Central Characterization Procedure (CCP) CCPTP- 005, CCP Acceptable Knowledge Documentation. This AKA specifically addresses the subpopulation of containers previously certified by CCP for waste stream SNL-HCF-S5400-RH during AHCF repackaging campaigns 11, 12, 14, and 17 and primarily consists of fuel examination waste (FEW). This subpopulation of containers was generated primarily at the HCF from the late 1970s to mid-1990s, and repackaging history as well as historical information are listed in Attachment 1, Waste Stream SNL-HCF-S5400-RH (FEW lnventory) Containers List. Attachment 2, Waste Stream SNL-HCF-S5400-RH (FEW lnventory) Container Evaluations, presents a summary review of site container documentation and the descriptions from the CCP visual examination (VE) during repackaging at the AHCF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗