Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Rydberg-atom-based single-photon detection for haloscope axion searches

We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 μ eV and 200 μ eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear amplifiers is limited by quantum measurement noise, which can be avoided by using a single-photon detector. Our single-photon detection scheme can offer scan rate enhancements up to a factor of 10 4 over traditional linear amplifier readout, and is compatible with many different haloscope cavities. We identify multiple haloscope designs that could use our Rydberg-atom-based single-photon detector to search for QCD axions with masses above 40 μ eV (10 GHz), currently a minimally explored parameter space. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral dependence of the linewidth enhancement factor in quantum dot lasers

The spectral analysis of amplified spontaneous emission is used to determine the linewidth enhancement factor (α-factor) in lasers based on InAs/InGaAs quantum dots (QDs) in a wide spectral range near the ground-state optical transition energy. The effect of the pump current and number of QDs on the spectral dependences of the α-factor is examined. The temperature dependence of the spectra of the α-factor is experimentally determined for the first time for lasers with InAs/InGaAs QDs. An explanation is suggested for the observed anomalous decrease in the α-factor with increasing temperature.

36 MATERIALS SCIENCE↗

Characterization of a 30-GHz IMPATT solid state amplifier

Described are the characterization and testing of a 20 W solid state amplifier operating in the Ka band to be used in low cost experimental ground terminals. The amplifier was developed by the TRW Electronic Systems Group under NASA Contract NAS3-23266 as a proof-of-concept (POC) device in support of the Advanced Communications Technology Satellite (ACTS) program. Additional goals were development of high-power IMPATT devices and circulators, and multistage diode circuits, which are an integral part of the amplifier. The amplifier underwent acceptance testing at the NASA Lewis Research Center, Cleveland, Ohio. Characteristics measured include the output power of 42 dB m, gain of 30 dB, an injection-locking RF bandwidth of 260 MHz, and an overall direct current-to-radiofrequency (dc-to-RF) efficiency of 6.7 percent.

Wald, Lawrence W.↗

Design of a near-IR coherent lidar for high spatial and velocity resolution wind measurement

A coherent Doppler lidar based on a CW diode-pumped, injection seeded, Th:YAG laser operating at approx. 2.02 microns is currently under development. This system is optimized for measurements of boundary layer winds with high spatial, temporal, and velocity resolution. Initially, the system will run alongside a new high repetition rate (5-10 kHz) CO2 mini-Master Oscillator Power Amplifier (mini-MOPA) Doppler lidar, which will provide simultaneous range-resolved Differential Absorption Lidar (DIAL) water vapor measurements. Water vapor DIAL operation of the 2 micron system is being considered as a future option. The anticipated specifications and the preliminary design are discussed.

Grund, Christian J.↗

High-Voltage, Asymmetric-Waveform Generator

The shapes of waveforms generated by commercially available analytical separation devices, such as some types of mass spectrometers and differential mobility spectrometers are, in general, inadequate and result in resolution degradation in output spectra. A waveform generator was designed that would be able to circumvent these shortcomings. It is capable of generating an asymmetric waveform, having a peak amplitude as large as 2 kV and frequency of several megahertz, which can be applied to a capacitive load. In the original intended application, the capacitive load would consist of the drift plates in a differential-mobility spectrometer. The main advantage to be gained by developing the proposed generator is that the shape of the waveform is made nearly optimum for various analytical devices requiring asymmetric-waveform such as differential-mobility spectrometers. In addition, this waveform generator could easily be adjusted to modify the waveform in accordance with changed operational requirements for differential-mobility spectrometers. The capacitive nature of the load is an important consideration in the design of the proposed waveform generator. For example, the design provision for shaping the output waveform is based partly on the principle that (1) the potential (V) on a capacitor is given by V=q/C, where C is the capacitance and q is the charge stored in the capacitor; and, hence (2) the rate of increase or decrease of the potential is similarly proportional to the charging or discharging current. The proposed waveform generator would comprise four functional blocks: a sine-wave generator, a buffer, a voltage shifter, and a high-voltage switch (see Figure 1). The sine-wave generator would include a pair of operational amplifiers in a feedback configuration, the parameters of which would be chosen to obtain a sinusoidal timing signal of the desired frequency. The buffer would introduce a slight delay (approximately equal to 20 ns) but would otherwise leave the fundamental timing signal unchanged. The buffered timing signal would be fed as input to the level shifter. The output of the level shifter would serve as a timing and control signal for the high-voltage switch, causing the switch to alternately be (1) opened, allowing the capacitive load to be charged from a high-voltage DC power supply; then (2) closed to discharge the capacitive load to ground. Hence, the output waveform would closely approximate a series of exponential charging and discharging curves (see Figure 2).

Beegle, Luther W.↗

DEVELOPMENT OF SOLID-STATE DRIVERS FOR THE NIF PLASMA ELECTRODE POCKELS CELL

Large aperture Plasma Electrode Pockels Cells (PEPC) are an enabling technology in the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory. The Pockels cell allows the NIF laser to take advantage of multipass amplifier architecture, thus reducing costs and physical size of the facility. Each Pockels cell comprises four 40-cm x 40-cm apertures arranged in a 4 x 1 array. The combination of the Pockels cell and a thin-film polarizer, configured in a 4 x 1 array, form an optical switch that is key to achieving multi-pass operation. Solid-state Plasma Pulse Generators (PPGs) and high current high voltage solid-state Switch Pulse Generators (SPGs) have been developed for use in the PEPC. The solid-state plasma pulse generators initiate and maintain plasma within the cells; each pulser is capable of delivering 60J of energy to each plasma channel. Deployment of the solid-state PPGs has been completed in NIF. The MOSFET-switched SPG is capable of delivering a requisite fast rise time, 17kV flattop pulse to the cells nonlinear crystals. A complete software and hardware control system has been developed and is currently being tested for use on the solid-state SPGs. Also a transmission line modeling, development, and testing effort is in process, in support of NIFs Advanced Radiographic Capabilities (ARC). Work is scheduled for completion by the end of the calendar year.

42 ENGINEERING↗

The PTPN2/PTPN1 inhibitor ABBV-CLS-484 unleashes potent anti-tumour immunity

Immune checkpoint blockade is effective for some patients with cancer, but most are refractory to current immunotherapies and new approaches are needed to overcome resistance. The protein tyrosine phosphatases PTPN2 and PTPN1 are central regulators of inflammation, and their genetic deletion in either tumour cells or immune cells promotes anti-tumour immunity. However, phosphatases are challenging drug targets; in particular, the active site has been considered undruggable. Here we present the discovery and characterization of ABBV-CLS-484 (AC484), a first-in-class, orally bioavailable, potent PTPN2 and PTPN1 active-site inhibitor. AC484 treatment in vitro amplifies the response to interferon and promotes the activation and function of several immune cell subsets. In mouse models of cancer resistant to PD-1 blockade, AC484 monotherapy generates potent anti-tumour immunity. We show that AC484 inflames the tumour microenvironment and promotes natural killer cell and CD8 + T cell function by enhancing JAK–STAT signalling and reducing T cell dysfunction. Inhibitors of PTPN2 and PTPN1 offer a promising new strategy for cancer immunotherapy and are currently being evaluated in patients with advanced solid tumours (ClinicalTrials.gov identifier NCT04777994). More broadly, our study shows that small-molecule inhibitors of key intracellular immune regulators can achieve efficacy comparable to or exceeding that of antibody-based immune checkpoint blockade in preclinical models. Finally, to our knowledge, AC484 represents the first active-site phosphatase inhibitor to enter clinical evaluation for cancer immunotherapy and may pave the way for additional therapeutics that target this important class of enzymes.

60 APPLIED LIFE SCIENCES↗

WATER MASERS IN THE ANDROMEDA GALAXY: THE FIRST STEP TOWARD PROPER MOTION

We have detected and confirmed five water maser complexes in the Andromeda Galaxy (M31) using the Green Bank Telescope. These masers will provide the high brightness temperature point sources needed for proper motion studies of M31, enabling measurement of its full three-dimensional velocity vector and its geometric distance via proper rotation. The motion of M31 is the keystone of Local Group dynamics and a gateway to the dark matter profiles of galaxies in general. Our survey for water masers selected 206 luminous compact 24 {mu}m emitting regions in M31 and was sensitive enough to detect any maser useful for {approx}10 {mu}as yr{sup -1} astrometry. The newly discovered masers span the isotropic luminosity range (0.3-1.9) x 10{sup -3} L{sub sun} in single spectral components and are analogous to luminous Galactic masers. The masers are distributed around the molecular ring, including locations close to the major and minor axes, which is nearly ideal for proper motion studies. We find no correlation between 24 {mu}m luminosity and water maser luminosity, suggesting that while water masers arise in star-forming regions, the nonlinear amplification pathways and beamed nature of the water masers means that they are not predictable based on IR luminosity alone. This suggests that there are additional bright masers to be found in M31. We predict that the geometric distance and systemic proper motion of M31 can be measured in 2-3 years with current facilities. A 'moving cluster' observation of diverging masers as M31 approaches the Galaxy may be possible in the long term.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting the sensitivity and specificity of published real-time PCR assays

Background: In recent years real-time PCR has become a leading technique for nucleic acid detection and quantification. These assays have the potential to greatly enhance efficiency in the clinical laboratory. Choice of primer and probe sequences is critical for accurate diagnosis in the clinic, yet current primer/probe signature design strategies are limited, and signature evaluation methods are lacking. Methods: We assessed the quality of a signature by predicting the number of true positive, false positive and false negative hits against all available public sequence data. We found real-time PCR signatures described in recent literature and used a BLAST search based approach to collect all hits to the primer-probe combinations that should be amplified by real-time PCR chemistry. We then compared our hits with the sequences in the NCBI taxonomy tree that the signature was designed to detect. Results: We found that many published signatures have high specificity (almost no false positives) but low sensitivity (high false negative rate). Where high sensitivity is needed, we offer a revised methodology for signature design which may designate that multiple signatures are required to detect all sequenced strains. We use this methodology to produce new signatures that are predicted to have higher sensitivity and specificity. Conclusion: We show that current methods for real-time PCR assay design have unacceptably low sensitivities for most clinical applications. Additionally, as new sequence data becomes available, old assays must be reassessed and redesigned. A standard protocol for both generating and assessing the quality of these assays is therefore of great value. Real-time PCR has the capacity to greatly improve clinical diagnostics. The improved assay design and evaluation methods presented herein will expedite adoption of this technique in the clinical lab.

59 BASIC BIOLOGICAL SCIENCES↗

Active control of Alfvén eigenmodes by external magnetic perturbations with different spatial spectra

Alfvén eigenmodes have been suppressed and excited in tokamak plasmas by (just) modifying the poloidal spectra of externally applied static magnetic perturbations. This effect is observed experimentally when toroidal spectra of n = 2, n = 4 as well as a mixed spectrum of n = 2 and n = 4 is applied. Under the n = 2 magnetic perturbations, the modes are excited or suppressed by modifying the coil phasing between the upper and the lower set of coils. Regardless of the absolute rotation, an even parity for the n = 4 perturbation is observed to reduce the amplitude of the Alfvénic instabilities, while an odd parity amplifies it. To combine the stabilizing (and destabilizing) effect of n = 2 and n = 4, a mixed spectrum is applied, finding similar reduction (and amplification) trends. However, the impact on the mode amplitude is more subtle, due to the reduced coil current required for a mixed spectrum. The signal level on the fast-ion loss detector is sensitive to the applied poloidal spectrum, which is consistent with Hamiltonian full-orbit modelling of an edge resonant transport layer activated by the 3D perturbative fields. An internal redistribution of the fast-ion population is induced, modifying the phase-space gradients driving the Alfvénic instabilities, and ultimately determining their existence. The calculated edge resonant layers for both n = 2 and n = 4 toroidal spectra are consistent with the observed suppressed and excited phases. Moreover, hybrid kinetic-magnetohydrodynamic (MHD) simulations reveal that this edge resonant transport layer overlaps in phase-space with the population responsible for the fast-ion drive. The results presented here may help to control fast-ion driven Alfvénic instabilities in future burning plasmas with a significant fusion born alpha particle population.

Alfvén waves↗

Weakly Magnetized, Hall Dominated Plasma Couette Flow

A novel plasma equilibrium in the high-β, Hall regime that produces centrally peaked, high Mach number Couette flow is described. Flow is driven using a weak, uniform magnetic field and large, cross field currents. Large magnetic field amplification (factor 20) due to the Hall effect is observed when electrons are flowing radially inward, and near perfect field expulsion is observed when the flow is reversed. In conclusion, a dynamic equilibrium is reached between the amplified (removed) field and extended density gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, construction and evaluation of a 12.2 GHz, 4.0 kW-CW high efficiency klystron amplifier

An analytical and experimental program is described, for studying design techniques for optimizing the conversion efficiency of klystron amplifiers, and to utilize these techniques in the development and fabrication of an X-band 4 kW cw klystron, for use in satellite-borne television broadcast transmitters. The design is based on a technique for increasing the RF beam current by using the second harmonic space charge forces in the bunched beam. Experimental analysis was also made of a method to enhance circuit efficiency in the klystron cavities. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments employing an axisymmetric, electrostatic collector for linear beam microwave tubes.

Vishida, J. M.↗

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles. COLLIDE retains granular material under vacuum in a shallow tray behind a metal door, which then opens and releases the particles into a larger open volume when microgravity is achieved. The experiment is observed with a high-speed camera, such that the motions of these particles can then be tracked so the kinematics of each grain may be analyzed. The original application for this apparatus was to study cratering events into granular beds, but electrostatic repulsion was detected in the early frames of the video data returned from completed experiments, so a re-flight with a focus on these events was proposed. Agitation of the grains during launch combined with the frictional charge transfer between the grains and the door as it slides open provides an opportunity to use this setup to observe material tribocharging and charged particle behaviors in microgravity. In this updated version, the charged particles released into the chamber will traverse through an electric field produced by high voltage parallel plates and their resulting trajectories will be determined by their net charges. WES was originally developed to characterize the triboelectric properties of the Martian regolith through the contact of a rover wheel with the surface as it rotates. Improvements were made upon this legacy system to develop a sensor suite that will be installed within the COLLIDE door to measure charge transferred between the granular material and insulating disks protruding through the door. These insulator disks span the triboelectric series so, as they slide across the particulate matter when the door opens, each will accumulate a charge consistent with its relative position to the grains within the series. This charge on each insulator is distributed between two capacitances in series with an electrometer amplifier returning an analog voltage proportional to the charge accumulated. Calibration of this system has been performed using applications of known charge to the inputs and characterization of the frictional charge transfer between various regolith simulants and the sensor insulators is currently being examined in the lab.

Electrostatics↗

Spontaneous electromagnetic fluctuations in unmagnetized plasmas. III. Generalized Kappa distributions

In the first two papers of this series, the general expressions for the spontaneous fluctuations spectra (electric and magnetic field, charge and current densities) from uncorrelated plasma particles are derived and illustrated for a Maxwellian (relativistic or nonrelativistic) plasma close to thermal equilibrium. In this paper, the results are illustrated for the nonideal case of a plasma out of thermal equilibrium and described by the generalized Kappa (power-law) particle distribution function in the nonrelativistic limit. The suprathermal fluctuations of weakly amplified modes and aperiodic modes are provided. Thus, it is shown for the first time the existing finite level of noncollective fluctuations, which are particularly important in the context of plasma fluctuations (collective or noncollective) as the best agent in the energy dissipation and transfer to suprathermal populations. The results obtained in the first paper for an equilibrium plasma are recovered only in the limit of a very large power index {kappa}{yields}{infinity}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards new functional nanostructures for medical imaging

Nanostructures represent a promising new type of contrast agent for clinical medical imaging modalities, including magnetic resonance imaging, x-ray computed tomography, ultrasound, and nuclear imaging. Currently, most nanostructures are simple, single-purpose imaging agents based on spherical constructs (e.g., liposomes, micelles, nanoemulsions, macromolecules, dendrimers, and solid nanoparticle structures). In the next decade, new clinical imaging nanostructures will be designed as multi-functional constructs, to both amplify imaging signals at disease sites and deliver localized therapy. Proposals for nanostructures to fulfill these new functions will be outlined. New functional nanostructures are expected to develop in five main directions: Modular nanostructures with additive functionality; cooperative nanostructures with synergistic functionality; nanostructures activated by their in vivo environment; nanostructures activated by sources outside the patient; and novel, nonspherical nanostructures and components. The development and clinical translation of next-generation nanostructures will be facilitated by a combination of improved clarity of the in vivo imaging and biological challenges and the requirements to successfully overcome them; development of standardized characterization and validation systems tailored for the preclinical assessment of nanostructure agents; and development of streamlined commercialization strategies and pipelines tailored for nanostructure-based agents for their efficient translation to the clinic.

60 APPLIED LIFE SCIENCES↗

Mechanisms for suppressing the transverse mode coupling instability in a circular accelerator

The chromatic and nonlinear suppression of the transverse mode coupling instability in a circular accelerator is analyzed. Analytical estimates are compared with the results of experiments and numerical simulations. The transverse mode coupling (or fast head-tail) instability is a significant factor that limits the beam intensity in circular accelerators. This instability arises when the bunch current exceeds a threshold value determined by the broadband impedance of the vacuum chamber. Feedback systems are traditionally used to suppress the instability. The experience of working with such systems shows that their efficiency depends strongly on the operating parameters of the amplifier, particularly on the chromaticity and nonlinearity of the magnetic lattice. Thus, both chromatic and nonlinear effects should be taken into account to better understand the physical processes and to increase the feedback efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ENSO Dynamics in the E3SM-1-0, CESM2, and GFDL-CM4 Climate Models

We report that this study examines historical simulations of ENSO in the E3SM-1-0, CESM2, and GFDL-CM4 climate models, provided by three leading U.S. modeling centers as part of the Coupled Model Intercomparison Project phase 6 (CMIP6). These new models have made substantial progress in simulating ENSO’s key features, including: amplitude; timescale; spatial patterns; phase-locking; spring persistence barrier; and recharge oscillator dynamics. However, some important features of ENSO are still a challenge to simulate. In the central and eastern equatorial Pacific, the models’ weaker-than-observed subsurface zonal current anomalies and zonal temperature gradient anomalies serve to weaken the nonlinear zonal advection of subsurface temperatures, leading to insufficient warm/cold asymmetry of ENSO’s sea surface temperature anomalies (SSTA). In the western equatorial Pacific, the models’ excessive simulated zonal SST gradients amplify their zonal temperature advection, causing their SSTA to extend farther west than observed. The models underestimate both ENSO’s positive dynamic feedbacks (due to insufficient zonal wind stress responses to SSTA) and its thermodynamic damping (due to insufficient convective cloud shading of eastern Pacific SSTA during warm events); compensation between these biases leads to realistic linear growth rates for ENSO, but for somewhat unrealistic reasons. The models also exhibit stronger-than-observed feedbacks onto eastern equatorial Pacific SSTAs from thermocline depth anomalies, which accelerates the transitions between events and shortens the simulated ENSO period relative to observations. Implications for diagnosing and simulating ENSO in climate models are discussed.

54 ENVIRONMENTAL SCIENCES↗

Telecommunications technology development for the Deep Space Network

The telecommunications technology that is currently being developed for the Deep Space Network (DSN), a system providing communications and navigation support for NASA's deep space missions, is discussed. The major areas of development include Ka-band (32 GHz) technology, beam waveguide antennas, low-noise amplifiers, coding, navigation techniques, high-power transmitters, and optical technology. The expected payoffs of the new technology during the mid-1990's and later are examined.

Yuen, J. H.↗