Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

AAV-mediated conversion of human pluripotent stem cell-derived pacemaker

Malfunction of nodal pacemaker (Pm) cardiomyocytes (CMs) due to diseases or aging leads to rhythm generation disorders, necessitating electronic Pm implantation. We functionally reprogrammed human pluripotent stem cell (hPSC) derived-ventricular (V) CMs into -PmCMs via recombinant adeno-associated virus serotype 9 (rAAV9)-mediated overexpression of engineered HCN1 channel (HCN1ΔΔΔ) whose S3-S4 linker has been strategically deleted by design to promote cardiac pacemaking. rAAV9-HCN1ΔΔΔ-reprogrammed hPSC-PmCMs converted from -VCMs showed automaticity and action potential parameters typical of native nodal PmCMs. Implantation of rAAV9-HCN1ΔΔΔ-based BPm in a preclinical porcine model of complete heart block significantly reduced the dependence on device-supported pacing and generated spontaneous heart rhythms from the BPm. Collectively, these results have further laid the groundwork on BPm for future translation.

60 APPLIED LIFE SCIENCES↗

Isolation and characterization of ventricular-like cells derived from NKX2-5 eGFP/w and MLC2v mCherry/w double knock-in human pluripotent stem cells

Highlights: • NKX2-5{sup eGFP/w} and MLC2v{sup mCherry/w} hPSC double knock-ins were established. • Culture conditions mimic in vivo cardiac developmental process. • Subtype-specific cardiac development and functional analysis were possible. Human pluripotent stem cell (hPSC)-derived cardiomyocytes (CMs) are a promising source for cell transplantation into the damaged heart, which has limited regenerative ability. Many methods have been developed to obtain large amounts of functional CMs from hPSCs for therapeutic applications. However, during the differentiation process, a mixed population of various cardiac cells, including ventricular, atrial, and pacemaker cells, is generated, which hampers the proper functional analysis and evaluation of cell properties. Here, we established NKX2-5{sup eGFP/w} and MLC2v{sup mCherry/w} hPSC double knock-ins that allow for labeling, tracing, purification, and analysis of the development of ventricular cells from early to late stages. As with the endogenous transcriptional activities of these genes, MLC2v-mCherry expression following NKX2-5-eGFP expression was observed under previously established culture conditions, which mimic the in vivo cardiac developmental process. Patch-clamp and microelectrode array electrophysiological analyses showed that the NKX2-5 and MLC2v double-positive cells possess ventricular-like properties. The results demonstrate that the NKX2-5{sup eGFP/w} and MLC2v{sup mCherry/w} hPSCs provide a powerful model system to capture region-specific cardiac differentiation from early to late stages. Our study would facilitate subtype-specific cardiac development and functional analysis using the hPSC-derived sources.

60 APPLIED LIFE SCIENCES↗

Layered oxide cathode-inspired secondary hard carbon microsphere anode material for high-power and long-life rechargeable batteries

A new anode material that will provide lithium ion (Li-ion) batteries with high energy and power density is urgently needed. In this work, a layered oxide cathode-inspired secondary hard carbon microsphere (CMS) anode material was designed, and exhibited excellent rate performance and long cyclability. Polyacrylonitrile/poly(styrene-co-acrylonitrile) (PAN/SAN) compositions displaying the meatball-like shape of the PAN precursor were carbonized into CMSs having turbostratic microstructures. The CMS carbonized at 1,000°C (CMS1000) displayed high specific capacity at the highest current density of 1,000mAg -1 , i.e., 77.6 % of its average charge capacity at 100 mA g -1 , and considerable cycling retention after 500 cycles, i.e., 83.8 % of the specific capacity at cycle 25. In conclusion, our work demonstrates that the design of new anode materials is a fruitful route to improve commercial Li-ion batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of permeability and Biot coefficient at high mean stresses in high porosity sandstone

A series of constant mean stress (CMS) and constant shear stress (CSS) tests were performed to investigate the evolution of permeability and Biot coefficient at high mean stresses in a high porosity reservoir analog (Castlegate sandstone). Permeability decreases as expected with increasing mean stress, from about 20 Darcy at the beginning of the tests to between 1.5 and 0.3 Darcy at the end of the tests (mean stresses up to 275 MPa). The application of shear stress causes permeability to drop below that of a hydrostatic test at the same mean stress. Results show a nearly constant rate decrease in the Biot coefficient as the mean stress increases during hydrostatic loading, and as the shear stress increases during CMS loading. In conclusion, CSS tests show a stabilization of the Biot coefficient after the application of shear stress.

58 GEOSCIENCES↗

Ion-gated carbon molecular sieve gas separation membranes

Membrane technology lies at the heart of many industrial gas separation processes and applications. Molecular sieving membranes that break the Robeson limit are desirable for energy-efficient gas separation. In this paper, we report a facile strategy of directly integrating ionic liquids (ILs) into porous membranes. Particularly, the ILs form an ultra-thin layer on the carbon molecular sieve (CMS) membranes rather than penetrating into the pores, acting as a smart gate for gas entry to boost the selectivity. The hybrid membrane exhibits CO 2 permeability >600 barrer and enhanced CO 2 /N 2 selectivity >50, which surpasses the Robeson limit and shows potential in CO 2 /N 2 separation process. Molecular dynamics simulations confirm the gating effect of the IL layer of molecular thickness. In conclusion, this work demonstrates a universal strategy to improve CMS membrane performance by creating an IL-membrane interface and tuning the ion-pore interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The pixel tracking telescope at the Fermilab Test Beam Facility

An all silicon pixel telescope has been assembled and used at the Fermilab Test Beam Facility (FTBF) since 2009 to provide precise tracking information for different test beam experiments with a wide range of Detectors Under Test (DUTs) requiring high resolution measurement of the track impact point. The telescope is based on CMS pixel modules left over from the CMS forward pixel production. Eight planes are arranged to achieve a resolution of less than 8 μm on the 120 GeV proton beam transverse coordinate at the DUT position. In order to achieve such resolution with 100 × 150 μm 2 pixel cells, the planes were tilted to 25 degrees to maximize charge sharing between pixels. Crucial for obtaining this performance is the alignment software, called Monicelli, specifically designed and optimized for this system. This paper will describe the telescope hardware, the data acquisition system and the alignment software constituting this particle tracking system for test beam users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultraperipheral Collisions at RHIC and the LHC

The current status of ultraperipheral measurements in heavy ion collisions is discussed, with an emphasis on what is learned from one photon (photonuclear) and two photon (γ+γ) processes. Furthermore, the interpretation of recent data on “nonUPC” events, in which electromagnetic processes occur simultaneously with hadronic ones, is also discussed. Results from the LHC (ALICE, ATLAS, CMS, and LHCb) and the STAR experiment at RHIC are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Importance of non-flow in mixed-harmonic multi-particle correlations in small collision systems

Recently CMS Collaboration measured mixed-harmonic four-particle azimuthal correlations, known as symmetric cumulants SC(n, m), in pp and p+Pb collisions, and interpreted the non-zero SC(n, m) as evidence for long-range collectivity in these small collision systems. Using the PYTHIA and HIJING models which do not have genuine long-range collectivity, we show that the CMS results, obtained with standard cumulant method, could be dominated by non-flow effects associated with jet and dijets, especially in pp collisions. We show that the non-flow effects are largely suppressed using the recently proposed subevent cumulant methods by requiring azimuthal correlation between two or more pseudorapidity ranges. As a result, we argue that the reanalysis of SC(n, m) using the subevent method in experiments is necessary before they can used to provide further evidences for a long-range multi-particle collectivity and constraints on theoretical models in small collision systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of azimuthal anisotropies at forward and backward rapidity with muons in high-multiplicity p–Pb collisions at $\sqrt{s_{NN}} = 8.16$ TeV

The study of the azimuthal anisotropy of inclusive muons produced in p–Pb collisions at $\sqrt{s_{NN}}$ = 8.16 TeV, using the ALICE detector at the LHC is reported. The measurement of the second-order Fourier coefficient of the particle azimuthal distribution, v 2 , is performed as a function of transverse momentum p T in the 0–20% high-multiplicity interval at both forward (2.03 < y CMS < 3.53) and backward (-4.46 < y CMS < -2.96) rapidities over a wide pT range, 0.5 < p T < 10 GeV/c, in which a dominant contribution of muons from heavy-flavour hadron decays is expected at p T > 2 GeV/c. The v 2 coefficient of inclusive muons is extracted using two different techniques, namely two-particle cumulants, used for the first time for heavy-flavour measurements, and forward–central two-particle correlations. Both techniques give compatible results. A positive v 2 is measured at both forward and backward rapidities with a significance larger than 4.7σ and 7.6σ, respectively, in the interval 2 < p T < 6 GeV/c. Comparisons with previous measurements in p–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV, and with AMPT and CGC-based theoretical calculations are discussed. The findings impose new constraints on the theoretical interpretations of the origin of the collective behaviour in small collision systems

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of detector simulation in particle physics collider experiments

Through the last three decades, precise simulation of the interactions of particles with matter and modeling of detector geometries has proven to be of critical importance to the success of the international high-energy physics experimental programs. For example, the detailed detector modeling and accurate physics of the Geant4-based simulation software of the CMS and ATLAS particle physics experiments at the European Center of Nuclear Research (CERN) Large Hadron Collider (LHC) was a determinant factor for these collaborations to deliver physics results of outstanding quality faster than any hadron collider experiment ever before. This review article highlights the impact of detector simulation on particle physics collider experiments. It presents numerous examples of the use of simulation, from detector design and optimization, through software and computing development and testing, to cases where the use of simulation samples made a difference in the accuracy of the physics results and publication turnaround, from data-taking to submission. It also presents the economic impact and cost of simulation in the CMS experiment. Future experiments will collect orders of magnitude more data, taxing heavily the performance of simulation and reconstruction software for increasingly complex detectors. Consequently, it becomes urgent to find solutions to speed up simulation software in order to cope with the increased demand in a time of flat budgets. The study ends with a short discussion on the potential solutions that are being explored, by leveraging core count growth in multicore machines, using new generation coprocessors, and re-engineering of HEP code for concurrency and parallel computing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

Interaction between amiodarone and hepatitis-C virus nucleotide inhibitors in human induced pluripotent stem cell-derived cardiomyocytes and HEK-293 Cav{sub 1.2} over-expressing cells

Several clinical cases of severe bradyarrhythmias have been reported upon co-administration of the Hepatitis-C NS5B Nucleotide Polymerase Inhibitor (HCV-NI) direct-acting antiviral agent, sofosbuvir (SOF), and the Class-III anti-arrhythmic amiodarone (AMIO). We model the cardiac drug-drug interaction (DDI) between AMIO and SOF, and between AMIO and a closely-related SOF analog, MNI-1 (Merck Nucleotide Inhibitor #1), in functional assays of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), to provide mechanistic insights into recently reported clinical cases. AMIO co-applied with SOF or MNI-1 increased beating rate or field potential (FP) rate and decreased impedance (IMP) and Ca{sup 2+} transient amplitudes in hiPSC-CM syncytia. This action resembled that of Ca{sup 2+} channel blockers (CCBs) in the model, but CCBs did not substitute for AMIO in the DDI. AMIO analog dronedarone (DRON) did not substitute for, but competed with AMIO in the DDI. Ryanodine and thapsigargin, decreasing intracellular Ca{sup 2+} stores, and SEA-0400, a Na{sup +}/Ca{sup 2+} exchanger-1 (NCX1) inhibitor, partially antagonized or suppressed DDI effects. Other agents affecting FP rate only exerted additive or subtractive effects, commensurate with their individual effects. We also describe an interaction between AMIO and MNI-1 on Cav{sub 1.2} ion channels in an over-expressing HEK-293 cell line. MNI-1 enhanced Cav{sub 1.2} channel inhibition by AMIO, but did not affect inhibition of Cav{sub 1.2} by DRON, verapamil, nifedipine, or diltiazem. Our data in hiPSC-CMs indicate that HCV-NI agents such as SOF and MNI-1 interact with key intracellular Ca{sup 2+}-handling mechanisms. Additional study in a Cav{sub 1.2} HEK-293 cell-line suggests that HCV-NIs potentiate the inhibitory action of AMIO on L-type Ca{sup 2+} channels. - Highlights: • Adverse clinical interaction between amiodarone and HCV-NI drugs is captured by in vitro models. • Human iPSC-derived cardiomyocyte beating syncytial model points to Ca{sup 2+} handling effects. • Overexpressing human Ca{sup 2+} channel line model points to shifts in Ca{sup 2+} influx. • Shifts in Ca{sup 2+} current voltage-dependent inactivation play a role in the AER interaction.

60 APPLIED LIFE SCIENCES↗

Critical material content in modern conventional U.S. vehicle electronics

Critical materials (CM) are vital to modern technology. Components of modern vehicles can be recycled to recover and reuse the CMs to help ensure a supply of these materials. Electronic components from a 2015 GMC Sierra truck (21 components) and 2016 Toyota Camry sedan (10 components) were analyzed for CMs. The components were processed via size reduction, aqua regia leaching and dissolution, and final solutions were analyzed for metal content. It was found that most electronic components of both vehicles contain CM. The most concentrated CM in the components were Sn, Nb, and Tb. Nd and Co were found in several of the magnetic components. CM economic value was found to be low compared to the overall value of the components, and the CM content would not allow for a viable pathway for recycling. Remanufacturing of components may be a more economic option of reuse in the future.

2015 GMC Sierra↗

Flux Equations for Osmotically Moderated Sorption–Diffusion Transport in Rigid Microporous Membranes

The development of non-aqueous reverse osmosis separations via the use of rigid microporous membrane materials suggests that flux equations originally developed for swellable polymeric membranes should be revisited. This paper demonstrates that the gradient of fractional occupancy of penetrant molecules within the micropores of the membrane is the driving force for permeation without requiring assumptions about pressure within the membrane. Flux equations are derived using both Fickian and Maxwell-Stefan approaches, and different behavior in the permeate flux versus upstream hydraulic pressure relationship is shown to arise as a result of differences in the loading dependence of the single component Maxwell-Stefan diffusivity. Molecular modeling results available in the literature and experimental data obtained from carbon molecular sieve (CMS) membranes showcase that these loading-dependent changes in the Maxwell-Stefan diffusivity are possible. This loading dependence is separated into three regimes: so-called “weak confinement” diffusion and “strong confinement” diffusion, both of which have been discussed at length in the literature, and a new “hybrid confinement” diffusion, which is introduced here. Furthermore, the separation mechanism of solvent molecules through a rigid bimodally microporous membrane is studied using xylene molecules passing through CMS membranes fabricated under different conditions as examples. Altogether, this study provides fundamental insight and guidance into osmotically-moderated sorption-diffusion transport of solvent molecules through rigid microporous membranes.

36 MATERIALS SCIENCE↗

Unexpectedly Strong Size-Sieving Ability in Carbonized Polybenzimidazole for Membrane H 2 /CO 2 Separation

Polymers with high permeability and strong size-sieving ability are needed for H 2 /CO 2 separation at temperatures ranging from 100 to 300 °C to enable an energy-efficient precombustion CO 2 capture process. However, such polymers usually suffer from a permeability/selectivity tradeoff, that is, polymers with high permeability tend to exhibit a weak size-sieving ability and thus low selectivity. In this work, we demonstrate that carbonization of a suitable polymer precursor (i.e., polybenzimidazole or PBI) generates microcavities (leading to high H 2 permeability) and ultramicroporous channels (leading to strong size-sieving ability and thus high H 2 /CO 2 selectivity). Specifically, carbonization of PBI at 900 °C (CMS@900) doubles H 2 permeability and increases H 2 /CO 2 selectivity from 14 to 80 at 150 °C. When tested with simulated syngas-containing equimolar H 2 and CO 2 in the presence of water vapor for 120 h, CMS@900 exhibits stable H 2 permeability of ≈36 barrer and H 2 /CO 2 selectivity of ≈53 at 150 °C, above Robeson’s 2008 upper bound and demonstrating robustness against physical aging and CO 2 plasticization.

36 MATERIALS SCIENCE↗

Making metals linear super-elastic with ultralow modulus and nearly zero hysteresis

We demonstrate a novel materials design approach to achieve unprecedented properties by utilizing nanoscale chemo-mechanical coupling. In particular, by using computer simulations we demonstrate how to engineer ultralow modulus (12 GPa), nearly hysteresisfree, and linear super-elastic metals with a giant elastic strain limit (2.7%) by creating appropriate concentration modulations (CMs) at the nanoscale in the parent phase and by pre-straining to regulate the stress-induced martensitic transformation (MT). The nanoscale CMs created via spinodal decomposition produce corresponding phase stability modulations, suppress autocatalysis in nucleation, impose nano-confinements on growth, and hinder long-range ordering of transformation strain during the MT, which changes the otherwise sharp first-order transition into a smeared, macroscopically continuous transition over a large stress range. The pre-straining generates retained martensitic particles that are stable at the test temperature after unloading and act as operational nuclei in subsequent load cycles, eliminating the stress–strain hysteresis and offering an ultralow apparent Young’s modulus. Materials with a high strength and an ultralow apparent Young’s modulus have great potential for application in orthopaedic implants.

36 MATERIALS SCIENCE↗

Impact of Detector Simulation in Particle Physics Collider Experiments - Highlights

Detector simulation has become fundamental to the success of modern high-energy physics (HEP) experiments. For example, the Geant4-based simulation applications developed by the ATLAS and CMS experiments played a major role for them to produce physics measurements of unprecedented quality and precision with faster turnaround, from data taking to journal submission, than any previous hadron collider experiment. The material presented here contains highlights of a recent review on the impact of detector simulation in particle physics collider experiments published in Ref. [1]. It includes examples of applications to detector design and optimization, software development and testing of computing infrastructure, and modeling of physics objects and their kinematics. The cost and economic impact of simulation in the CMS experiment is also presented. A discussion on future detector simulation needs, challenges and potential solutions to address them is included at the end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗